SPECIFICATION
MODEL
RID-65A RID-65B
DC VOLTAGE RATED CURRENT CURRENT RANGE Note.6RATED POWER
Note.6OUTPUT
VOLTAGE ADJ. RANGE
SETUP, RISE TIME HOLD TIME (Typ.)VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY(Typ.)AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)LEAKAGE CURRENT SAFETY STANDARDS HARMONIC CURRENT EMS IMMUNITY WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT VIBRATION
MTBF
DIMENSION OTHERS NOTE
PACKING
OVER LOAD
OVER VOLTAGE 5V 12V CH25V CH124V CH26A
3A 4A 2A 0.3 ~ 8A 0.2 ~ 4A 0.3 ~ 8A 0.2 ~ 3A
66W
68W 80mVp-p 120mVp-p 80mVp-p 150mVp-p CH1:4.75 ~ 5.5V
CH1:4.75 ~ 5.5V 2.0%8.0% 2.0%10%0.5%0.5%
1.5%0.5%0.5%
2.0%5.0%
5.0%500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load 50ms/230VAC 12ms/115VAC at full load
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)47 ~ 63Hz 81%
82%
CH1: 5.75 ~ 6.75V
2A/115VAC 1.2A/230VAC COLD START 40A/230VAC <2mA / 240VAC
110 ~ 150%rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed UL60950-1,TUV EN60950-1Approved
Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A -25 ~ +70
(Refer to output load derating curve)
20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH
0.03%/(0 ~ 50)on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X,Y, Z axes 265.9Khrs min. MIL-HDBK-217F (25)
129*98*38mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
0.44Kg; 30pcs/14.2Kg/0.72CUFT
Protection type :Hiccup mode, recovers automatically after fault condition is removed Features :
RIPPLE & NOISE (max.)Note.2VOLTAGE TOLERANCE Note.3LINE REGULATION Note.4LOAD REGULATION Note.5
WITHSTAND VOLTAGE
ISOLATION RESISTANCE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
ENVIRONMENT PROTECTION
EMI CONDUCTION & RADIATION SAFETY &EMC
(Note 7)
Isolated output & GND for CH1,CH2Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105
Withstand 300VAC surge input for 5 second High operating temperature up to 70Withstand 5G vibration test
High efficiency, long life and high reliability 3 years warranty
long life electrolytic capacitors
CH1OUTPUT NUMBER
Mechanical Specification
Derating Curve Case No. 903 Unit:mm
Output Derating VS Input Voltage
INPUT VOLTAGE (VAC) 60Hz
8810095120115160
140
200
180
240220264
L O A D (%)
Ta=25
901008070
605040
4.5
73.5
9
3.5
3331
122.5
98
129
2-
M
3
7
85.5
18
3-M
3
18.5
9.5
120
6.5
77
323.5
3.53.5
4.5
7
65
4321
9.5
8.2
AMBIENT TEMPERATURE ()
L O A D (%)
-25
-2500
2010304020
408060
100605070(VERTICAL)
3828.5Terminal Pin. No Assignment
Pin No.Pin No.12634
57Assignment Assignment DC OUTPUT G1DC OUTPUT G2
DC OUTPUT +V2DC OUTPUT +V1
FG
AC/L AC/N