SPECIFICATION

MODEL

RID-65A RID-65B

DC VOLTAGE RATED CURRENT CURRENT RANGE Note.6RATED POWER

Note.6OUTPUT

VOLTAGE ADJ. RANGE

SETUP, RISE TIME HOLD TIME (Typ.)VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY(Typ.)AC CURRENT (Typ.)

INPUT

INRUSH CURRENT (Typ.)LEAKAGE CURRENT SAFETY STANDARDS HARMONIC CURRENT EMS IMMUNITY WORKING TEMP.

WORKING HUMIDITY

STORAGE TEMP., HUMIDITY

TEMP. COEFFICIENT VIBRATION

MTBF

DIMENSION OTHERS NOTE

PACKING

OVER LOAD

OVER VOLTAGE 5V 12V CH25V CH124V CH26A

3A 4A 2A 0.3 ~ 8A 0.2 ~ 4A 0.3 ~ 8A 0.2 ~ 3A

66W

68W 80mVp-p 120mVp-p 80mVp-p 150mVp-p CH1:4.75 ~ 5.5V

CH1:4.75 ~ 5.5V 2.0%8.0% 2.0%10%0.5%0.5%

1.5%0.5%0.5%

2.0%5.0%

5.0%500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load 50ms/230VAC 12ms/115VAC at full load

88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)47 ~ 63Hz 81%

82%

CH1: 5.75 ~ 6.75V

2A/115VAC 1.2A/230VAC COLD START 40A/230VAC <2mA / 240VAC

110 ~ 150%rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed UL60950-1,TUV EN60950-1Approved

Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A -25 ~ +70

(Refer to output load derating curve)

20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH

0.03%/(0 ~ 50)on +5V output

10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X,Y, Z axes 265.9Khrs min. MIL-HDBK-217F (25)

129*98*38mm (L*W*H)

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.

6. Each output can work within current range. But total output power can't exceed rated output power.

7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

0.44Kg; 30pcs/14.2Kg/0.72CUFT

Protection type :Hiccup mode, recovers automatically after fault condition is removed Features :

RIPPLE & NOISE (max.)Note.2VOLTAGE TOLERANCE Note.3LINE REGULATION Note.4LOAD REGULATION Note.5

WITHSTAND VOLTAGE

ISOLATION RESISTANCE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

ENVIRONMENT PROTECTION

EMI CONDUCTION & RADIATION SAFETY &EMC

(Note 7)

Isolated output & GND for CH1,CH2Universal AC input / Full range

Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105

Withstand 300VAC surge input for 5 second High operating temperature up to 70Withstand 5G vibration test

High efficiency, long life and high reliability 3 years warranty

long life electrolytic capacitors

CH1OUTPUT NUMBER

Mechanical Specification

Derating Curve Case No. 903 Unit:mm

Output Derating VS Input Voltage

INPUT VOLTAGE (VAC) 60Hz

8810095120115160

140

200

180

240220264

L O A D (%)

Ta=25

901008070

605040

4.5

73.5

9

3.5

3331

122.5

98

129

2-

M

3

7

85.5

18

3-M

3

18.5

9.5

120

6.5

77

323.5

3.53.5

4.5

7

65

4321

9.5

8.2

AMBIENT TEMPERATURE ()

L O A D (%)

-25

-2500

2010304020

408060

100605070(VERTICAL)

3828.5Terminal Pin. No Assignment

Pin No.Pin No.12634

57Assignment Assignment DC OUTPUT G1DC OUTPUT G2

DC OUTPUT +V2DC OUTPUT +V1

FG

AC/L AC/N