Determination of Formaldehyde from Vehicle Interior with Modified Flask Method VDA 275

Moulded composites and fleeces for vehicles

Determination of formaldehyde release

Test procedure called modified flask method

1.Purpose and application

The present test method describes a necessary procedure to the method of the formaldehyde release from the vehicle interior.

The procedure is applied to the check of the equability of the production of form parts.

It can be applied restrictedly for the material development and to the receiving control.

2.Reference to other testing methods

VDA 276- Measuring procedure of formaldehyde, ammonia and phenols release form the vehicle interior with the use of 1 m2 chamber.

https://www.sodocs.net/doc/268746859.html,

Name of the procedure of the formaldehyde release method. VDA 275.

4.Principle

In the test, samples of certain masses and dimension are fastened in a closed 1 litred Polyethylene flask with distilled water and are stored in steady temperature for a defined time. The bottles are then cooled and the dissolved formaldehyde in the distilled water is determined. The result is expressed in weight (mg/kg).

5.Reagents

For the analysis, reagents of analytic grade and distilled or demineralized water must be used. The formaldehyde content is determined photometry after the Acetylaceton method. Nevertheless, other procedures should be allowed if they correspond in specifications to the reference procedure for the analysis

5.1Acetylaceton p.a.

5.2 Ammonium acetate p.a.

Remark: Commercially pre-prepared solutions can be used when the identical result is achieved.

6.Test equipment

6.1 Balance with range + 1 mg

6.2 Well ventilated warm chamber which is able to hold a temperature from

103+2oC.

6.3 Circulating air warm chamber which is able to hold a temperature from

60+2oC

6.4 Spectrophotometer

6.5 Test apparatus

---1 litred Polyethylene flask with a lid (see appendix picture 1)

---Hooks from high-grade steel with poetries, used in the lid of the test bottle

6.6 Lab. Device

--Precision burette 50ml, calibrated at 20oC

--2 Measuring cylinder, 1000ml, calibrated at 20oC

--6 Measuring cylinder, 100ml, calibrated at 20oC

--Pipette, 5ml, calibrated at 20oC

--Pipette, 10ml, calibrated at 20oC

--Pipette, 15ml, calibrated at 20oC

--Pipette, 20ml, calibrated at 20oC

--Pipette, 25ml, calibrated at 20oC

--Pipette, 50ml, calibrated at 20oC

--Pipette, 100ml, calibrated at 20oC

--Conical

250ml

flask,

--Bottle, 50ml with stop

--Watch glass with diameter of 120mm

--Desiccator

--Cuvette with suitable thickness for the spectrophotometer

watch

--Stop

7.Specimen

7.1.1 Specimen: The test bodies should be taken from suitable and representative

places of the vehicle interior parts

7.1.2 The size of the test bodies in each case should be 40 mms x 100 mms x

thickness. At least 6 test bodies are taken, of it 5 parts for the test and 1 for

the moisture content test

8.Realization of the check

8.1Number of the check: These are professional method to be carried out

8.2 Determination of the moisture content

The moisture content is determined with DIN EN 322

8.3 Regulation of the formaldehyde release

The test bodies become precise-weighed out before the beginning of the analysis on the analysis scales on 0.01 g. In each of the Polyethylene flask become 50 ml distilled water is pipetted.

For the connection, the test bodies will provide 10 mms of the upper edge concentric with 1 to 2 mms of drilling for the purpose of connection in the hanging hook.

After fixing of the test bodies in the hook (see appendix: picture 1) the vessel is closed and is kept more than 3 hours in the warm chamber (6.3) with a steady temperature at 60oC.

At the end of the test time the vessels from the warm chamber are taken. After 60 minute stabilizing time at ambient temperature the test bodies from the test bottle are removed.

8.4 The control test

The attempt is carried out without test body in parallel.

8.5 Regulation of the formaldehyde concentration in the absorbent solution

The formaldehyde content of the absorbent solution is detected by photometry after the Acetylaceton method.

8.5.1 The principle

The chemical reaction (see appendix on the so-called Hantzschen: picture 2) with which dissolved formaldehyde reacts in solution react with Ammonia and Acetylaceton to form Diacetyldihydrolutidin (DDL). The absorption maximum of DDL is 412 nm. The reaction is specific for formaldehyde.

8.5.2 Reagent

8.5.2.1 Acetylaceton solution

4ml of Acetylaceton are dispensed in a 1000 ml to measuring cylinder and is made up to 1000 ml with distilled water. The solution air-tighted and can be used for 4 weeks if kept away from light.

8.5.2.2 Ammonium acetate solution

200 g of ammonium acetate is dispensed in a 1000ml measuring cylinder and make up to 1000ml with distilled water.

8.5.3 Reaction

10ml of the absorbent solution (8.3) are taken with a pipette and are moved in a 50ml bottle with 10 ml Acetylaceton solution (8.5.2.1) and 10 ml ammonium acetate-solution (8.5.2.2). The bottle is closed, shaken and warmed up for 15 minutes in a waterbath at 40oC. The greenish-yellow solution is then cooled at ambient temperature, protected from the sunlight (about one hour). The optical density of this solution is determined with a wavelength of 412 nm by distilled water with a Spectrophotometer (6.4). A control is determined in parallel with distilled water and is taken into consideration with the calculation of the bottles value (9.2).

Remark: After every test, the PE flasks are cleaned in a lab washer. Should this not be sufficient, it is advisable that the flasks are kept at 70oC openly in a circulating air warm chamber for approximately 16 h.

8.5.4 Calibration curve

The calibration curve (see appendix: pictures 3 and 4) is constructed by means of a formaldehyde standard solution whose concentration was determined by titration with iodine. The calibration curve must be checked at least once per week.

8.5.4.1 Formaldehyde-standard solutions reagent solutions

Iodine c(I2 )=0.05 mol/l

Sodium thiosulfate c(Na2S2O3 )=0.1 mol/l

Sodium hydroxide c(NaOH) = 1mol/l

Sulfuric acid c(H2SO4 )= 1 mol/l

Indicator solution 1% m/m

The Titer of the solutions must be checked before use.

About 1 g of formaldehyde solution (concentration of 35 to 40%) are solved in a 1000 ml measuring cylinder with distilled water and are filled in up to mark. The exact formaldehyde concentration is determined as follows:

20ml of the formaldehyde-standard solution are mixed with 25ml iodine solution and 10ml mixed sodium hydroxide solution. After 15 minute stabilizing time under light, 15ml sulfuric acid is added to the mixture. The excess iodine reacts with the thiosulfate solution. At the end of the titration some drops of indicator

solution are added. The control is carried out with 20ml to distilled water in parallel.

The formaldehyde content is calculated with the following formula:

c (HCHO) = (Vo-V)x15 [ c(Na2S2O3)] x 1000/20

Where:

c (HCHO): Formaldehyde concentration in mg/l

Vo: Volumes of the thiosulfate solution for the control in ml

V: Volumes in thiosulfate solution in ml

c(Na2S2O3): Concentration of the thiosulfate solution in mol/l

Remark: 1ml 0.1 mol/l thiosulfate solution corresponds to 1 ml 0.05 mol/l of iodine solution and 1.5 mg of formaldehyde

8.5.4.2 Formaldehyde calibration solution (with thickness of the cuvette: 1 cm)

From the formaldehyde standard solution, determined in 8.5.4.1, becomes a volume which contains 15 mg of formaldehyde from a microburette in a 1000ml measuring cylinder and filled with distilled water up to mark filled in. 1 ml of this solution contains 15 μg formaldehyde.

8.5.4.3 Calibration curve

0, 5, 10, 20, 50 or 100 ml are filled in by the formaldehyde calibration solution

(8.5.4.2) in a 100ml measuring cylinder and with distilled water up to mark. 10ml

of solution are photometrically analyzed with the same procedure, as that of 8.5.3.

The optical densities are applied against the formaldehyde concentration (between

0 and 15 μg/ml) on standard curve. The upward gradient is determined

graphically or is calculated.

8.5.4.4 Formaldehyde calibration solution (with thickness of the cuvette: 5 cm)

From the formaldehyde-standard solution, determines under 8.5.4.1, becomes a volume which contains 3 mg of formaldehyde with a microburette in a 1000ml measuring cylinder and make up to mark with distilled water. 1ml of this solution contains 3 μg of formaldehyde.

8.5.4.5 Calibration curve

0, 5, 10, 20, 50 or 100 are filled in by the formaldehyde calibration solution

(8.5.4.4) ml in a 100ml measuring cylinder and with distilled water up to mark.

10ml of solution is photometrically analyzed with the same procedure, as that of

8.5.3. The optical densities are applied against the formaldehyde concentrations

(between 0 and 3 μg/ml) on standard curve. The upward gradient is determined graphically or is calculated.

9.Calculation of the results

9.1Moist content

The moist content H (in masses % m/m) of the form part arises from the following formula:

H = m1-m0 x 100

m0

Besides, is:

m1: the masses of the test bodies before the drying in gram

m0: the masses of the test bodies after the drying in gram

9.2 Formaldehyde release with flask method

The whole amount of dissolved formaldehyde becomes from the upward gradient factor of the photo-metrical regulation and the whole volume of the absorbent liquid (here: 10ml) investigates. This Formaldehyde is calculated with the weight corrected on dry weight of the test body in mg / kg.

Calculation of the formaldehyde delivery in mg / kg:

(As –A B)x f x Vx (100+H) x F =mg HCHO / kg dry test material

m x 1000

As: the optical density of the analyzed solution

A B: the optical density of the analysis with distilled water

f: the upward gradient factor of the calibration function (in μg/ml)

m: the masses of the test body in g

H: the moisture content of the test material in percent

V: the volume of the absorbent solution (50 ml)

atro: absolutely dry test material

F: Factor to the calculation of the result of analysis in kg [mg / kg]; F=10

10.Test report

In the test report the following information should be given with reference to this test method, if necessary:

- Origin of the test material

- Place, position and state of the material at the time of the sampling, in particular the humidity

-date and production of the material

-date of the sampling

-date of the test performed

-moisture content (%) at the time of the check (according to 8.2)

-formaldehyde release after the flask method (mg of formaldehyde / kg dry test

material)

-description of other details 1)

1) Report on all occurrences which are not according to this test regulation

(withdrawal of the test bodies, conditioning etc.)

甲醛方法验证报告

方法验证报告 项目名称:甲醛 方法名称:乙酰丙酮分光光度法 标准名称:《水质甲醛的测定乙酰丙酮分光光度法》(HJ 601-2011)检测机构: 报告日期:

甲醛方法验证报告 一、目的: 验证实验室是否有能力及资源达到标准《水质甲醛的测定乙酰丙酮分光光度法》(HJ 601-2011)的要求,以确保该实验室能够公正准确得到实验结果并出具报告,以满足检验要求。 二、职责: 本检测项目负责人依据《水质甲醛的测定乙酰丙酮分光光度法》(HJ 601-2011),对该项目的各方法验证参数进行验证,根据实验室数据填写相关检测原始记录,并形成方法验证报告。 三、依据标准及检测方法: 1、依据标准 《水质甲醛的测定乙酰丙酮分光光度法》(HJ 601-2011) 2、检测方法 乙酰丙酮分光光度法 3、适用范围 本标准适用于地表水、地下水中甲醛的测定 四、试验主要仪器及试剂: 1、紫外分光光度计; 2、甲醛标准贮备液 3、硫代硫酸钠标准溶液、乙酰丙酮溶液、氢氧化钠溶液、甲醛标准使用液等(按检测标准配制)。 4、25ml具塞比色管、500ml全玻璃蒸馏器 五、人员

六、符合性指标: 1、线性相关:标准曲线相关系数r≥0.9990 2、方法检出限:MDL:0.05mg/L 3、精密度:RSD≤1.3%-5.4% 4、准确度:加标回收率为80%~120% 七、确认方式: ?线性相关;?方法检出限;?重复性测试;?加标回收试验 八、检测要点简述: 取6支25ml具塞比色管,分别加0ml、0.50ml、1.00ml、3.00ml、5.00ml、8.00ml甲醛标准溶液(5.00ug/ml),用水稀释定容至25.0ml,加乙酰丙酮溶液2.5ml,混匀,置于(60±2)℃水浴加热15min,取出冷却至室温,在414nm波长下,用1cm比色皿,以水作参比,测定各管溶液的吸光度,以甲醛含量为横坐标,校正吸光度为纵坐标,绘制标准曲线,用标准曲线定量。 九、试验数据: 1、标准曲线的测定 (1)试验过程: 按标准方法配制标准系列并按标准方法处理,并绘制标准曲线。 (2)试验数据: 标准曲线(扣除空白吸光度绘制) (3) 标准曲线测定结果 表9-1 标准曲线的制作结果

甲醛含量指标

甲醛含量、放射性等各项指标 导语:装修污染,指装饰材料、家具等含有的对人体有害的物质,释放到家居、办公环境中造成的污染。国家颁布实施的《民用建筑工程室内环境污染控制规范》列出五种主要污染物:甲醛、苯、氨气、挥发性有机物、放射性氡。北极光环保认为装修的目的是安居,怎么防范污染以最大程度地减少对人的危害? 1.装修污染的危害有哪些? 装修污染物的释放长达3-15年,它们的危害包括: 1)造成人体免疫功能异常、肝损伤、肝损伤及神经中枢受影响; 2)对眼、鼻、喉、上呼吸道和皮肤造成伤害; 3)引起慢性健康伤害,减少人的寿命; 4)严重的可引起致癌、胎儿畸形、妇女不孕症等; 5)对小孩的正常生长发育影响很大,可导致白血病、记忆力下降、生长迟缓等; 6)对女性容颜肌肤的侵害,更是不在话下。由于甲醛对皮肤粘膜有强烈的刺激作用,接触后会出现皮肤变皱、汗液分泌减少等症状。汗液分泌减少会阻碍毛孔内脏物和人体新陈代谢。 2.怎样判断室内污染?

1)新装修的房间或购买的新家具有刺眼、刺鼻等刺激性异味,而且超过一年仍然气味不散。 2)每天清晨起床时,感到憋闷、恶心、甚至头晕目眩。 3)家里人经常容易患感冒。 4)虽然不吸烟,也很少接触吸烟环境,但是经常感觉嗓子不舒服,有异物感,呼吸不畅。 5)家人常有皮肤过敏等毛病,而且是群发性的。 6)家里小孩常咳嗽、打喷嚏、免疫力下降,新装修的房子孩子不愿意回家。 7)家人共有一种疾病,而且离开这个环境后,症状就有明显变化和好转。 8)新婚夫妇长时间不怀孕,查不出原因。 9)孕妇在正常怀孕情况下发现胎儿畸形。 10)新搬家或者新装修后,室内植物不易成活,叶子容易发黄、枯萎,特别是一些生命力很强的植物也难以正常生长。 11)搬家后,家养的宠物猫、狗甚至热带鱼莫名其妙的死掉,而且邻居家也是这样。

空气质量甲醛方法确认报告

乙酰丙酮分光光度法测定 空气质量甲醛的方法验证报告 1.目的 通过乙酰丙酮分光光度法测空气质量中甲醛的检出限、精密度、盲样的分析,判断本实验室的检测方法是否合格。 2.职责 2.1 检测人员负责按操作规程操作,确保测量过程正常进行,削除各种可能影响试验结果的意外因素,掌握检出限、精密度的计算方法,。 2.2 技术负责人负责审核检测结果和方法验证报告。 3.方法依据及适用范围 本方法依据:GB/T 15516-1995。适用于树脂制造、涂料、人造纤维、塑料、橡胶、染料、制药、油漆、制革等行业的排放废气以及作医药消毒、防腐、熏蒸时产生的甲醛蒸气测定。 4.方法原理 甲醛气体经水吸收后,在pH = 6的乙酸-乙酸铵缓冲溶液中,与乙酰丙酮作用,在沸水浴条件下,迅速生成稳定的黄色化合物,在波长413nm处测定。 5. 仪器与试剂 5.1 仪器 5.1.1分光光度计(1cm比色皿) 5.1.2一般试验室仪器 5.2试剂 甲醛标准溶液:5.00μg/ml 乙酰丙酮溶液:25g乙酸铵,加少量水溶解,加3ml冰乙酸及0.25ml乙酰丙酮,混匀再加水至100ml,调节pH=6.0 。 6.操作步骤 6.1 绘制校准曲线 6.1.1配制甲醛溶液标准系列 取25ml具塞比色管,用甲醛标准溶液按下表制备标准系列。

管号 0 1 2 3 4 5 6 甲醛标准溶液(ml ) 0 0.20 0.80 2.00 4.00 6.00 7.00 蒸馏水(ml) 10.00 9.80 9.20 8.00 6.00 4.00 3.00 甲醛含量μg 1.0 4.0 10.0 20.0 30.0 35.0 各管中,加入乙酰丙酮溶液2.0ml ,混匀。置于沸水浴中3min ,取出冷却至室温,1cm 吸收池,以水作参比,于波长413nm 处测吸光度。将上述系列标准溶液测得吸光度扣除空白吸光度值,绘制标准工作曲线。 6.1.2开启752型可见分光光度计,待仪器自检完后,设定有关参数,将去离子水放入比色槽中调零,测量得到回归曲线。 6.2 样品的测定: 采样后,将样品全部转入50ml 或10ml 比色管中,用水稀释定容。取少于10ml 试样于25ml 比色管中,加水定容至10.0标线,以下步骤同绘制标准工作曲线测吸光度。 空白试验:用现场未采样吸收管的吸收液按绘制标准工作曲线步骤测空白吸光度。 7. 计算公式 试样中甲醛浓度c (mg/m 3): nd 21 m c V V V ??= 式中:m--根据校准曲线计算甲醛含量,μg V 1--定容体积,mL V 2--测定取样体积,mL V nd --所采气体标准状态体积,L 8.方法验证试验 8.1 检出限测定: 8.1.1按第6步骤绘制标准曲线,计算回归方程,结果如下:

甲醛测试实验报告模板

甲醛测量实验报告 一、实验目的: 1、了解电化学甲醛测试仪的测试原理。 2、学习电化学甲醛测试仪的测试方法。 二、测试原理: 电化学甲醛测试仪应用的传感器为电化学甲醛传感器。这类传感器以电化学半电池为基础,由一对贵金属电极组成的电极系统,充以特定的电解液(与被测气体有关)并经全密封封装组成(图1)。传感器中另一个重要部件是半通透膜,它可选择性地让被测气体分子通过扩散方式进入传感器电解液,将大部分干扰物质的分子阻隔掉,因而有效减少干扰。透过的气体在工作电极上,在水分子上参与下,发生氧化还原反应,引起电子转移而形成与被测气体浓度有关的电极电流或电势。甲醛的电化学反应如下: 三、测试过程:(见使用说明书)

1、校验调整 (1)使用标配温度计测试温度数值为℃,在校正源的温度/浓度对算表中推论出浓度数值为ppm。 (2)出去校正源两端的黄色盖子。 (3)放置校正源及温度计在一个工作台上。 (4)依照校正源箭头的方向,把它插入检测器仪的采样抽气头 (5)按下cal两侧的键,检测仪抽取样本,当采样泵停止工作后,移除校正管及小心的塞回两端的塞子。 (6)约60秒后,屏幕出现175ppm,此时输入校准值ppm。(7)按下采样键保存校准值,机器关闭。 2、采样测试 (1)再次启动仪器。 (2)按下采样键,测试室内甲醛浓度。 四、实验结果分析: 测试甲醛浓度为ppm。 五、思考题: 结合所学内容和实验结果,分析如何降低室内甲醛浓度。 1.尽量采用低甲醛含量和不含甲醛的室内装饰和装修材料, 这是降低室内空气中甲醛含量的根本。 2.在选购家具时,应选择刺激性气味较小的产品。 3.保持室内空气流通。

有关甲醛检测相关标准

有关甲醛检测相关标准 甲醛是一种原浆毒物,能与蛋白质结合,吸入高浓度甲醛后,会出现呼吸道的严重刺激和水肿、眼刺痛、头痛,也可发生支气管哮喘。皮肤直接接触甲醛,可引起皮炎、色斑、坏死等。经常吸入少量甲醛,能引起慢性中毒,出现粘膜充血、皮肤刺激症、过敏性皮炎、指甲角化和脆弱、甲床指端疼痛等。表现头痛、乏力、胃纳差、心悸、失眠、体重减轻以及植物神经紊乱等各种症。 甲醛作为反应剂被广泛用于各种纺织整理助剂中,如树脂整理剂、固色剂、柔软剂、黏合剂等都有游离甲醛释放。我们日常生活中所使用的合成纺织品、服装、皮革、床上用品、窗帘等都含有甲醛。科标检测中心,专业提供甲醛检测服务,专业的第三方检测机构,出具权威甲醛检测报告。 检测标准: 目前欧盟没有单一针对甲醛物质的管理法规,有关甲醛的控制要求都包含在相关具体产品法规管理要求中。目前甲醛限制涉及到的法规、标准、指令,部分如下:玩具安全要求EN71,生态化纺织品要求Oko-Tex100,德国食品卫生法LFGB,食品接触物质2004/1935/EC 指令等。 DB13/T 2143-2014 玻璃纤维增强共聚甲醛工程塑料 DB34/T 2081-2014 胶合板(无甲醛胶粘剂型) DB37/T 1247-2009 化妆品中甲醛的测定液相色谱法 DB43/ 517-2010 竹、木胶合砧板甲醛释放限量 DB43/T 444-2009 缩醛类胶粘剂中游离甲醛的测定 DB44/T 519-2008 食品中甲醛的快速检测方法 DB44/T 575-2008 龙头鱼中甲醛来源的判定方法 DB44/T 629-2009 化妆品中甲醛含量的测定乙酰丙酮分光光度法 DB51/T 1691-2013 日化产品中甲醛含量的测定柱前衍生高效液相色谱法 DB51/T 1789.2-2014 竹席类竹制件化学试验甲醛释放量和甲醛可萃取量的测定DB51/T 1918-2014 化妆品中甲醛含量的测定柱前衍生高效液相色谱法 FZ/T 64027-2012 低甲醛机织粘合衬 GB/T 13454.1-2013 塑料粉状三聚氰胺-甲醛模塑料(MF-PMCs)第1部分:命名系统和分类基础

品牌漆甲醛含量测试结果(包括测试全过程)

华润漆、多乐士、立邦漆甲醛含量测试结果(包括测试全过程)和九龙产品GB国家标准质检报告 工程师正在配置各浓度的标准甲醛溶液以便于绘制标准工作曲线。待曲线图绘制好、取样好的涂料溶液配比好,甲醛测试项目的测算工作也就要开始了 一、关键步骤测试依据——标准工作曲线的绘制 这也是用仪器测试甲醛含量的一个原理,分别吸取5ml按B.5.13配置的甲醛标准溶液,各加1ml乙酰丙酮溶液在100°C沸水中加热,保持3min,冷却至室温后用10mm池(以水为参比)在分光光度计412nm波长处测定吸光度。以5ml甲醛标准溶液中甲醛含量为横坐标,吸光度为纵坐标,绘制工作曲线。计算回归线的斜率,以斜率的倒数作为样品测定的计算因子。

第一格内溶液为清水(不含甲醛溶液),仪表显示为0,则表示吸光度为零。 第二格为一定浓度比的甲醛溶液,仪表仪表显示一定的数值,则表示一定的吸光度。 将记录的不同浓度比的甲醛溶液的吸光度数值记录下来,输入计算机的专业软件,便绘制出了标准的工作曲线。 二、待测样品按标准取样 第一个测试的是高级组的立邦醛净全效,我们开看下整个测试过程是怎么样的。

将事先蒸馏的挥发冷凝液体倒入三角烧杯,分类标上标签以示区分。 将分类好的各个样品待测液体按一定的标准,混合一定量的乙酰丙酮溶液。

将配比好乙酰丙酮溶液的待测样品加热,然后冷却,过程如同甲醛标准溶液配置过程。三、待测样品入仪器测试 随后,将预制好冷凝后的待测样品按同样的测试方式,加入仪器的容器格中,仪器则显示出该溶液的吸光度,逐步将每个品牌的涂料蒸馏预制样品溶液一一测试,若仪器的显示均为数值零,那么参考制作的标准工作曲线,我们发现吸光度与甲醛的含量成正比例关系,因此我们判断测试的品牌涂料的甲醛含量均为零。依照此方式,我们记录出每个品牌涂料产品的显示数值即吸光度。 测试结果所有涂料甲醛合格

职业卫生检测报告(甲醛 NO 粉尘等)

检测任务编号:(职)检(2020)0005号检测报告 用人单位:***有限公司 委托单位:***有限公司 检测类别:定期检测 2020年10月17日

说明 一本检测报告书涂改、部分复制、无公章和无签发人签字无效。二对报告书有异议者,请于收到报告书之日起15日内向本中心提出书面意见。 三对委托送检样品,本中心仅对来样检测数据负责。 四本报告书不得用于广告宣传。 地址: 邮编: 电话: 传真: E-mail:

声明 遵守国家有关法律法规和标准规范,在为***有限公司提供职业病危害因素检测服务过程中,坚持客观、真实、公正的原则,并对出具的《检测报告》承担法律责任。 (加盖公章) 2012年10月17日 资质证书编号签名 编写人: 审核人: 签发人:

目录 检测报告 (1) 1.检测依据 (1) 2.用人单位情况介绍 (1) 3.检测类别及范围 (1) 4.现场采样和测量情况 (5) 5.检测结果 (10) 6.结论 (11) 7.建议 (13) 附件:检测结果报告单

检测报告 1.检测依据 1.1《工业企业设计卫生标准》GBZ 1-2010; 1.2《工作场所有害因素职业接触限值第1部分:化学有害因素》GBZ 2.1-2007; 1.3《工作场所有害因素职业接触限值第2部分:物理因素》GBZ 2.2-2007; 1.4《工作场所空气中有害物质监测的采样规范》GBZ159-2004; 1.5《工作场所空气有毒物质测定第17部分:锰及其化合物》GBZ/T300.17-2017; 1.6《工作场所空气有毒物质测定第37部分:一氧化碳和二氧化碳》GBZ/T 300.37-2017; 1.7《工作场所空气有毒物质测定第99 部分:甲醛、乙醛和丁醛》300.99-2017; 1.8《工作场所空气中粉尘测定第1部分:总粉尘浓度》GBZ/T19 2.1-2007; 1.9《工作场所空气中粉尘测定第4部分:游离二氧化硅含量》GBZ/T19 2.4-2007; 1.10《工作场所物理因素测量第8部分:噪声》GBZ/T189.8-2007; 1.11《工作场所物理因素测量第9部分:手传振动》GBZ/T189.9-2007; 1.12《公共场所卫生检验方法第1部分:物理因素》GB/T 18204.1-2013; 1.13《照明测量方法》GB/T 5700-2008; 1.14《水力发电厂照明设计规范》NB/T 35008-2013; 1.15《职业卫生技术服务机构检测工作规范》安监总厅安健〔2016〕9号; 1.16《用人单位职业病危害因素定期检测管理规范》安监总厅安健〔2015〕16号。 2.用人单位情况介绍 单位名称:***有限公司 单位地址: 单位性质:国有企业 行业类型:电力(建设期) 3.检测类别及范围 3.1任务来源、检测类别、检测范围。

实验室中甲醛含量的测定

污染物分析专用实验 -------校园水环境污染物监测设计方案 学号:B13070728 姓名:蒋浩博 指导老师:葛晓燕、苏艳

目录 一、监测背景 (1) 二、基础资料的收集 (2) 三采样点的设置 (3) 四、检测项目的确定 (4) 五、采样时间和采样频率的确定 (4) 六、实验仪器 (4) 七、样品的预处理 (5) 八、结果表达、质量保证和实施计划 (6)

实验室甲醛含量测定设计方案 一、监测背景 实验室安全非常重要,为了学生的实验安全需要测量一下实验室的甲醛浓度。 二、基础资料的收集 甲醛的危害:刺眼流泪,粘膜发炎、喉部疼痛、肺部水肿、恶心呕吐等呼吸道疾病,而甲醛超标严重的导致女性月经紊乱、妊娠综合症、生育力下降及新生儿染色体异常、白血病。青少年智力下降。长期接触低剂量甲醛污染而导致鼻咽癌、脑癌、结肠癌,高浓度甲醛还破坏免疫系统、肝脏系统等。 室内甲醛含量标准:根据国家强制性标准,关闭门窗1小时后,每立方米室内空气中,甲醛释放量不得大于0.08毫克;如达到0.1-2.0毫克,50%的正常人能闻到臭气;达到2.0-5.0毫克,眼睛、气管将受到强烈刺激,出现打喷嚏、咳嗽等症状;达到10毫克以上,呼吸困难;达到50毫克以上,会引发肺炎等危重疾病,甚至导致死亡。 三、采样点的设置 在两个实验室中分别放置两个空气采样器,分别测量两次。 四、监测项目的确定 实验室甲醛含量测定 五、采样时间和采样频率的确定 分别在同学们做完实验前一个和后一个小时采样。检测实验室空气中的甲醛含量。 六、实验仪器 6.1 空气采样器; 6.2 皂膜流量计; 6.3 气泡吸收管:10mL;采工业废气时,用多孔玻板吸收管50mL或125mL,采样流量0.5mL/min时,阻力为6.7kPa±0.7 kPa,当管吸收率大于99%; 6.4 具塞比色管: 10mL。带5mL刻度,经校正;浓度高时,浓度高时,改用26mL,带10mL、250mL刻度。 6.5 分光光度计;

新装修房屋内甲醛含量检测报告

新装修房屋内甲醛含量检测报告 由于春季潮湿,不适合房屋装修。进入夏季后,也进入了房屋的装修季。趁着合适的夏季气候,房屋装修市场也开始火热起来。不过,专家提醒大家,房屋装修后,不能忽略装修后的室内空气净化处理,建议在家里可以放置西兰除味炭产品以及西兰清新剂,有助于空气净化。 目前装修中出现的污染主要是甲醛,主要来源于装修材料,家具、塑料壁纸、地毯等。甲醛是无色刺激性气体,能引起流泪、喉部不适。可引起恶心、呕吐、咳嗽、胸闷哮喘甚至肺气肿。长期接触低剂量甲醛,可引起慢性呼吸道疾病、女性月经紊乱、妊娠综合症,引起青少年儿童智力下降致癌促癌,因而对人体的危害十分严重。业内人士就建议,装修后的房屋一定要做好空气净化,消除甲醛等污染。为此,可以搭配使用西兰清新剂和除味炭,有助于空气净化。 据介绍,西兰是立白集团旗下中高端的专业清香品牌,以“给空气做减法”为研发的核心指导,不断推出一系列环保型、科技型清香产品。产品包括除了固体清香剂、气雾剂清香剂外,还包含环保型水基液体清新剂、凝胶清新剂、除味除湿的天然竹炭产品。据西兰研发人员介绍,装修后的房屋空气净化处理,可把西兰除味炭与西兰清新剂搭配使用。 西兰除味炭的原料选择的是行业内高品质的成年高山毛竹,这种竹子经过高温煅烧使竹炭炭质致密,孔隙多,无毒、无味、无副作用,这种炭质的气孔能更有效吸收空气中的甲醛、苯等有毒气体,从而能起到净化空气的功效。在使用西兰家居除味炭进行空气净化后,再配合使用西兰清新剂做进一步的空气净化处理。西兰清新剂有淡雅百合、茉莉等六款香型,采用去离子水为溶剂,配以高档香精,使用更安全,能有效消除室内各种难闻或残留异味。

相关主题