搜档网
当前位置:搜档网 › 观音岩电站增效扩容改造工程

观音岩电站增效扩容改造工程

观音岩电站增效扩容改造工程
观音岩电站增效扩容改造工程

观音岩电站增效扩容改造工程

工程调度运行方案

编制

审核

黔东南州地方电力总公司施秉分公司

二O一六年一月二十八日

目录

一、工程慨况———————————————————————3

二、水文条件———————————————————————4

三、调度运用原则—————————————————————5

(一)防洪调度原则————————————————————5

(二)洪水调度原则————————————————————6

四、联合调度方案—————————————————————7

五、各级洪水操作方式———————————————————8

六、调度运用权限—————————————————————9

七、运用条件———————————————————————9

八、运用要求———————————————————————9

观音岩电站增效扩容改造工程

工程调度运行方案

为科学、合理调度运用本工程,确保工程安全,充分发挥工程效益,逐步实现管理的规范化、制度化,根据《大中型水电站水库调度规范》(GB17621-1998)、《综合利用水库调度通则》(水利部水管[1994]106号)、《水库调度设计规范》(GB/T 50587-2010)相关规定,特制订本方案。

一、工程概况

观音岩电站位于施秉县城西北9km舞阳河干流上,属黔东南州境内舞阳河流域梯级开发的第4级电站,该电站水库下游有施秉县城、施秉诸葛洞电站、湘黔铁路、镇远红旗电站和镇远、岑巩、玉屏等县城,工程地理位置及其重要。观音岩电站以发电为主,主要的枢纽建筑物有拱坝水库、左岸发电隧洞、地面式发电厂房和变电站等组成。

观音岩水电站坝址以上流域面积941km2,电站水库正常蓄水位599.0m,死水位577.0m,已批复的主汛期汛限水位596.0m,电站水库总库容12300万m3,正常蓄水位以下库容11670万m3,死库容4040万m3,

调节库容为7630万m3,具有不完全年调节性能,电站原总装机

2×6300kw,经扩容后装机为2×8000kw,该电站是舞阳河梯级的龙头电站之一。

大坝为砼砌块石双曲拱坝,坝高82.1m,坝顶宽5m,底宽13.9m,坝顶弧长135.96m,坝顶设有8×6m弧形钢闸门5扇,大坝左岸挡水坝段内设有放空兼冲砂底孔,孔身断面2.5×2.5m2。为了监测大坝的运行情况,确保大坝安全,还作了大坝内部观测和外部观测设计,埋设安装了应力、温度、渗压水平和垂直位移等观测设备。

引水隧洞位于大坝左岸,其进水口采用岸塔式。隧洞长270m,洞径4.4m,采用混凝土喷锚衬砌。

建筑物最低处为发电厂房,位于大坝下游左岸,发电机高程为541.00m,,现装有2台8000kw水轮发电机组。水轮机型号为HLA835C-LJ-140,发电机型号为SF8000-16/3250,发电厂房为地面式厂房,靠山布置。分主副厂房,主厂房长32.58m,宽14.6m,高24.56m;副厂房长35.98m,宽8.8m,高15.61m。该电站升压站采用内式开关站,位于副厂房中控室左侧。

二、水文条件

舞阳河流域属中亚热带温暖湿润季风气候区,年平均气温15.3℃,变化范围在14.2~16.4℃。月平均最高气温多发生在7月,干流中下游在26~28℃之间,干流上游及支流上游在24~26℃之间,1月气温最低,平均在4~6℃之间。全年无霜期在290天左右,年均日照时数1174h。年平均相对湿度,施秉~镇远一带76%~80%之间,其余地区80~84%之间。年平均风速,上游发源地2~3m/s,其余大坝分地区1~2m/s。

舞阳河流域年平均降水量1149.8mm,变化范围900~1300mm之间,南少北多。降水量年内分配,一年中4~7月连续最大4个月降水量占年降水量的56.2%左右,降水的年际变化,以岑巩县凯本站最大,1967年(1732.7mm)是1979年(708.2mm)的2.4倍;施秉皂角屯站1976年(1314.1mm)是1966年(762.4mm)的1.7倍。

本流域的暴雨主要是由冷锋低槽型暴雨和两高切变线天气系统造

成,每次暴雨历时多在24h以内,且12h降雨占85%以上。舞阳河流域位于背风坡谷槽地带,暴雨的频率和强度都比南面清水江、都柳江流域要小,是我省低暴雨区之一。上游旧州亦常出现暴雨,但量级和强度都比邻近流域暴雨小。

三、调度运用原则

(一)防洪调度原则

(1)遭遇一般洪水时,在保证大坝安全前提下,按下游防洪需要对洪水进行调蓄,减少下游洪水损失。

(2)遭遇超过下游防护对象防洪标准的洪水时,在保证大坝安全的前提下,水库尽可能进行调蓄削峰,尽量减轻下游的洪水灾害。

(3)遭遇超过水库校核标准洪水时,应启动非常泄洪措施,力保大坝安全。

(4)水库与下游河道堤防防洪体系联合运用,充分发挥水库的调洪作用。

(5)在实时调度中对各种可能影响泄洪的因素要有足够的估计。

(6)汛期限制水位以上的防洪库容调度运用,按各级防汛指挥部门的调度权限,实行分级调度。

坚持以人为本、安全至上、生命至上的原则。各水位控泄流量应遵循逐渐增大,避免泄量突变的原则。

(二)洪水调度原则

根据下游防洪要求和水库自身条件,防洪调度方式为:观音岩电站水库调度兼顾大坝安全与下游防洪需要。在库水位低于防洪高水位时按下游防洪要求调度;当水位高于防洪高水位时,按保证大坝安全要求调度。

一)、主汛期(5月1日~7月31日)

溢洪道开启:

当上游旧州水文站流域观测到水位增加到20年一遇洪水位时,或有持续暴雨情况时,可能发生洪水,观音岩水电站水库按水库水位控制闸门开度及孔数,确保水位不上升,入、出库流量相等,当水位有抬高趋

势时,可加开闸门,按照2#、4#、1#、5#的顺序逐孔开启,直至全开所有闸门。

底孔开启:

水位超过598.00m,且溢洪道闸门全开,参照原预案安排,前一时段水位上涨超过0.60m时加开底孔,泄量132 m3/s,按最大下泄能力调洪。水位低于598.00m时可关闭底孔。

二)、后汛期(8月1日~9月30日)

溢洪道开启:

当水库水位超过598.00m时,按水库水位控制闸门开度及孔数,确保水位不上升,入、出库流量相等,当水位有抬高趋势时,可加开闸门,逐孔开启,直至全开所有闸门。

底孔开启:

水位超过598.00m,溢洪道闸门全开,前一时段水位上涨超过0.60m 时加开底孔,泄量132 m3/s,按最大下泄能力调洪。水位低于598.00m时关闭底孔。

四、联合调度方案

观音岩水电站水库汛期调度运用与《舞阳河流域(贵州段)自动化防洪调度方案》相协调,参照《近期舞阳河防洪调度方案》调度方式进行,充分利用上游两岔河水库防洪库容,减轻下游防洪压力。

(一)前汛期(4月1日~4月30日),两岔河水库要将水位逐步降至汛限水位720.00m,预留1420万m3的防洪库容,准备度汛。观音岩水电站水库要控制水位由正常蓄水位599.00m降至运行控制水位597.00m以下运行。

(二)主汛期(5月1日~7月31日),两岔河水库运行在汛限水位720.00m以下,准备迎接强降水导致的洪水,观音岩水电站水库维持运行在运行控制水位597.00m以下,随时和上游两岔河水库、旧州水文站及黄平气象站保持通讯畅通,当上游发生强降水,水库、水文站水位监测到可能发生较大洪水时,观音岩水电站水库应及时预泄库容,将水位

降至596.00m,预泄洪水要控制泄量不超过400m3/s,并在4h以内完成。

(三)后汛期(8月1日~9月30日),两岔河水库可逐步提升水位至正常蓄水位724.00m、观音岩水库可提升至598.00m运行,同时做好后汛期防洪工作,遇到洪水合理安排预泄,两岔河水库可通过泄洪洞将水库水位降至720.00m,观音岩水库可开闸下泄,根据实际情况,决定是否需要预泄至597.00m以下。

五、各级洪水操作方式

(一)无论底孔或是溢洪道,以控制水位不上涨为原则,采取逐渐开启控制下泄的方式,观音岩水电站水库闸门采用电机启闭,人工控制开度,遇小洪水只开启中间的3#闸门,当下泄不能有效控制水位上涨时对称开启2#、4#闸门,根据实际来水情况,逐步开启,直至打开1#、5#闸门,进入自由溢流阶段;

(二)对于50年一遇及以下的中小洪水,以保下游安全为主,开启3#、2#、4#闸门预泄,控制泄量不超过400m3/s,4小时内降至

596.00m,水位上涨至598.00m不开启底孔情况下,5扇闸门全开的最大下泄流量为875m3/s,小于安全泄量885 m3/s;

(三)当水位达到设计洪水位598.82m,发生百年一遇洪水时,以保大坝安全为主,所有泄洪设施均开启;

(四)当水库水位达到600.50m,底孔、溢洪道已全开,说明已达到千年一遇洪水,需要密切关注,必要时采取非常措施。

六、调度运用权限

(一)正常生产调度由镇远分公司调度室统一调度。

(二)设计洪水标准以下的由施秉分公司防汛领导小组或生技科负责调度,同时报告黔东南州防汛办、施秉县防汛办、施秉县海事处、镇远分公司调度室。超过设计洪水标准时应立即通知工程责任人(分管该工程的副州长),由州人民政府防汛机构安排调度。

七、运用条件

水库管理单位应当根据批准的计划和水库主管部门的指令进行水库的调度运用。在汛期,水库调度运用必须服从防汛指挥机构的统一指挥。

水库调度运用要采用先进技术和设备,研究优化调度方案,依靠科

学进步,不断提高水库调度运用工作的技术水平。

八、运用要求(水库调度运用的基本资料及其要求)

基本资料是水库调度运用的基础,必须可靠。对水库调度运用关系重要的几项资料要求如下:

(1)库容曲线。应使用近期合格的1/5000~1/25000地形图量制的库容曲线成果。在多沙河流上的水库,要求三至五年施测一次库区地形图(包括水下部分),如发生大洪水应在当年汛后施测,并绘制新库容曲线。一般河流上的水库,当泥沙淤积对有效库容影响较大时,亦应施测库区地形图,修正原库容曲线,并按程序核定后公布使用。

(2)设计洪水。运行多年的水库应对原设计洪水进行复核,使用最新审批的成果。

(3)泄水、输水建筑物的泄流曲线,应经过实测资料率定。

(4)下河道的安全泄流量。要采用流域防洪规划所规定的水库下游河道控制断面的安全泄流量。

水库管理单位,应将水库的基本资料汇编成册,并根据资料的积累和变化情况及时予以补充和修正。

从观音岩水电站水库多年运行情况来看,水库库容曲线成果合理可靠。故观音岩水电站坝址的库容曲线采用观音岩水电站原设计成果,库容曲线见表2-3-1.

表2-3-1 观音岩水库水位~面积~库容曲线

高程(m)面积(万m2)库容(万m3)

53000

54043.672.7

54547.0222

55050.5457

5601011280

5651401880

5701732660

5752083610 5802614780 5852956170 5903707830 5953989750 60052912060 60560814900 61060817940 61586321600 62086325820 625101130500 630114635890 635121841800 640155748720 645163556700 650197865720

黔东南州地方电力总公司施秉分公司二O一六年一月十四

平安山一级电站增效扩容改造项目可行性研究报告

1综合说明 1.1绪言 平安山水库位于博罗县柏塘镇白芒洞水,距柏塘镇约8km。水库集雨面积为4.6km2,水库总库容为38.5万m3,正常库容为30万m3。大坝设计洪水标准为:20年一遇洪水设计,200年一遇洪水校核。平安山水库捍卫下游800人民群众的生命安全,保护土地面积350亩,是一座以防洪、供水、发电等综合利用的小(2)型水利工程。 工程等别为Ⅴ等,主要建筑物为5级,次要建筑物为5级。 水库于2011年1月竣工蓄水,主要枢纽建筑物由大坝、开敞式溢洪道、压力输水涵管和平安山一级电站组成,水库下游依次分别建有平安山二级电站(装机?)、平安山三级电站(装机?)。平安山一级电站原装机1台,总容量为100kw,设计年年发电量70.14万kwh。目前由博罗县平安山林场负责管理。 平安山一级电站为坝后式电站,直接由平安山水库大坝坝压力输水涵管引水,本电站始建于1986年8月,于1987年8月投产发电,安装了1台蜗壳式水轮发电机组,水轮机型号为HL260-WJ-50,额定出力为160kw,最大水头33m,额定水头30.8m,最小水头5m,额定流量为0.67m3/S;配套1台型号为TSWN74/36-10的发电机,额定功率160kw,额定电压0.4kv,额定电流288A,额定转速500r/min,额定励磁电压31.3V,额定励磁电流141.5A。经过二十多年的运行,机电设备不断老化,机组的效率逐年下降,在额定工况下,机组出力达不到额定出力。近三年实际平均发电量9.42万kwh,小于设计年发电量70.14万kwh,因下游供水及发电需求增大,从焦木村及狗底窝上游的河道引水至水库,引水集雨面积2.98km2。 平安山一级站运行多年,为缓解博罗县电力供需矛盾,促进工农业生产发展发挥了极其重要的作用。 为贯彻落实《中共中央国务院关于加快水利改革发展的决定》(中发【2011】1号)和《中华人民共和国可再生能源法》精神,提高水能资源利用效率,保障农村用电需要,促进农村水电持续有序发展,中央财政从可再生能源发展专项资金中安排资金,支持开展农村水电增效扩容改造试点工作。 我设计单位受博罗县平安山林场的委托,2013年11月开始实施初步设计工作,2013

二龙山水电站增效扩容改造项目监理规划范本

二龙山水电站增效扩容改造项目 监理规划 编制: 校核: 批准: 陕西江龙工程项目管理有限公司 二 0 一二年四月

目录 第一章:工程概况 第二章:监理工作依据、围、方式及容第三章:监理工作目标 第四章:监理组织机构及人员岗位职责第五章:工程质量控制及措施 第六章:工程进度控制及措施 第七章:工程投资控制及措施 第八章:工程安全控制及措施 第九章:合同管理及其他事项 第十章: 工程信息管理

二龙山水电站增效扩容改造项目 监理规划 一.工程概况 二龙山水库位于长江二级支流的丹江上游,距离商州城西约5公里,水库流域面积956km2,总库容8100万m3,正常库容5700万m3,其中有效库容3800万m3,死库容1900万m3.坝高63.7m,溢流坝顶高程765.0m非溢流坝段高程771.2m校核洪水位770.46m,正常蓄水位765.0m,死水位751m。 该工程主要由大坝、冲沙底孔、引水隧洞、电站、灌溉管涵等组成,为三级建筑物。坝址以上拦截丹江干流及其主要支流板桥河,控制流域面积966km2,为土石山区。坝址处河床宽80m,平均比降8.7%. 拦河大坝为浆砌石重力坝,迎水面现浇混凝土防渗面板,厚1.5-2m。坝高68.7m,坝顶总长153m,其中溢流坝段总长60m,净长57m,坝顶高程765m,底宽55m。非溢流坝段总长92m,左岸长48m,右岸长44m,底宽50m,坝顶高程771.7m,宽7m,上置防浪墙高1.2m。为排沙及便于调节水位,在靠近溢流坝右设泄水底孔,进口高程728.75m,断面2×2.8m,置钢制平板闸门控制,以12.5吨启闭机启闭,最大泄水流量188m3/s。2008年为加大泄洪能力,在坝左岸又开凿一条泄水底孔,断面尺寸,高程与原右岸泄水底孔同。 坝左岸开凿长152m的发电引水隧洞,直径4m,用混凝土初衬,下接钢叉管。引水入坝后水电站,设计安装3×1250kw的水轮发电机组。 主厂房长32m,宽10m,高17.3m。副厂房布置在主厂房上游侧,

变电站综自设备改造工程施工方案

忠路35kV变电站综自设备改造及主变增容 工程施工方案 工程概况 忠路35kV变电站于2002年10月建成投运,变电容量1×2000kVA,变电站综自采用深圳振华CDD-2000B系统。经过近十年连续运行,变电站多套微机保护装置损坏,监控系统、远动系统基本瘫痪,安全隐患突出,加之近期主变严重过载,影响忠路供区安全可靠供电。为保证该站安全稳定运行,公司决定改造变电站综合自动化系统1套,更换S11-4000/35型变压器1台,为优化改造施工作业方案,减少停电施工作业时间,确保改造施工作业安全、施工进度和作业质量,现根据3月26日根据现场勘察情况,制定本方案。 二、施工任务 (一)变电站综自设备改造 (1)35/10kV双卷变压器微机保护装置1套。 (2)10-35kV线路微机保护及测控装置11套(35kV线路保护装置3套,10kV线路保护装置8套),集中组屏。 (3)综合测控装置1套 (4)24路小电流选线装置1套 (5)变电站后台监控系统1套 (6)远动系统1套 (7)更换蓄电池18只12V100AH 2、主变增容规模 退出目前运行主变,将建南变电站S9-4000/35主变安装至忠路变电站现有主变位置。 3、全站一次设备防腐及水泥杆架加固补强 4、微机防误系统改造 全站增加网络微机防误系统一套。 (三)工程安装范围 1、35kV出线间隔3个(35KV户外真空开关3台)、35kV母线TV间隔1个及相应间隔保护自动装置。 2、10kV出线间隔6个(10KV户外真空开关6台)、10kV母线TV间隔1个(10kV母线TV 一台)及相应间隔保护自动装置。 3、35kV主变间隔1个(主变1台、35kV户外真空开关1台、10kV户外真空开关1台)及主变保护自动装置。 (四)工程特点 1、本工程属改造工程,时间紧、任务重,点多面广,涉及部门多,人员复杂,必须合理安排,紧密配合。 2、施工现场与出线构架带电部位隔离,所有35kV线路继续运行,10kV忠后线、忠镇线继续运行,确保文斗、玉河变电站及忠路集镇供电。 3、35kV、10kV线路改线必须停电才能完成,应办理好停电申请经调度批准,停电计划必须统筹安排。 三、工作任务 (一)设备安装、调整 1、拆除原2000kVA主变一台,新安装调整4000kVA主变一台。 2、拆除原主变保护屏一面,原35kV、10kV线路保护屏各一面。

电站增效扩容改造工程完工验收鉴定书

湖北省狮子岩电站增效扩容改造工程 项目完工验收 鉴定书 房县狮子岩电站增效扩容改造工程 完工验收委员会

2015年7月 主持单位:湖北省水利厅、财政厅 项目法人:房县农村小水电增效扩容改造项目领导小组设计单位:房县水利水电勘测设计院 监理单位:十堰市大禹水利水电工程建设咨询有限公司主要施工单位:房县万顺园林开发有限公司 主要设备供应单位:河南瑞发水电设备有限责任公司质量监督单位:房水利水电工程质量安全监督管理站运行管理单位:房县狮子岩电站 验收时间:2015年7月 验收地点:房县狮子岩电站

前言 根据水利部《关于印发<农村水电增效扩容改造试点项目验收指导意见>的通知》(水电[2012]329号)和《小型水电站建设工程验收规程》(SL168)的有关规定,2015年7月15 日,由湖北省水利厅、财政厅在狮子岩电站共同主持召开了房县狮子岩电站电站增效扩容改造项目完工验收会议。参加会议单位有:湖北省水利厅、财政厅、十堰市水利电力局、十堰市财政局、房水利水电工程质量安全监督管理站、河南瑞发水电设备有限责任公司、房县水利水电勘测设计院、房县水利电力局、房县农村小水电增效扩容改造项目领导小组、房县狮子岩电站。会议成立了验收委员会,委员会由省水利厅、财政厅、房水利水电工程质量安全监督管理站、房县狮子岩电站等单位的领导和专家组成。 验收委员会委员查看了工程现场,听取了参建各方的工作报告,认真查阅了有关资料,并进行了充分讨论,形成了《房县狮子岩电站电站增效扩容改造项目完工验收鉴定书》。 一、项目设计情况 (一)项目名称及位置 工程名称:房县狮子岩电站增效扩容改造工程

一级水电站增效扩容改造工程初步设计报告

一级水电站增效扩容改造工程初步设计报告

目录 工程特性表 (1) 1 前言 (5) 1.1基本情况 (5) 1.2工程建设过程 (6) 1.3工程现状存在的主要问题 (7) 1.4增效扩容改造初步设计工作开展过程 (7) 2 现状分析及改造必要性评价 (9) 2.1水资源概况 (9) 2.2工程现状及存在的问题 (10) 2.3增效扩容改造的必要性 (16) 3 水文分析 (18) 3.1流域概况 (18) 3.2气象特征 (18) 3.3水文基本资料 (18) 3.4径流 (20) 3.5洪水 (25) 3.6泥沙 (30) 3.7上、下游水位 (31) 4 工程地质 (32) 4.1区域地质概况 (32) 4.2库区工程地质条件 (34) 4.3主体工程地质条件 (35) 4.4副坝工程地质条件 (38)

4.5泄洪洞、发电输水隧洞工程地质条件 (40) 4.6厂区工程地质条件 (40) 4.7天然建筑材料 (41) 4.8结论 (41) 5 工程任务和规模 (43) 5.1地方社会经济发展概况 (43) 5.2工程建设的必要性 (43) 5.3工程任务复核 (44) 5.4工程等级与洪水标准复核 (44) 5.5特征水位复核 (44) 5.6水能计算 (44) 5.7装机容量选择 (53) 5.8装机容量复核 (53) 5.9能量指标及特征水头 (55) 6 改造设计 (56) 6.1设计总体方案 (56) 6.2设计依据 (56) 6.3水工建筑物改造设计 (59) 6.4机电设备改造 (63) 6.5控制设备改造 (82) 6.6金属结构设备改造 (82) 7 消防设计 (83) 7.1消防设计标准与原则 (83) 7.2工程消防设计 (84) 7.3消防给水设计 (85)

35KV某变电站综合自动化改造工程施工组织设计

35kV金熊变电站综合自动化改造工程施工设计方案

说明 一、本施工方案一式六份,分别送潜江供电公司生技部、安监部、调度、输变电工区,另一份放在施工现场,一份本单位存档。 二、施工方案经过上级审批通过后,必须严格按计划执行,各类施工必须按计划时间开工及在计划工期内完成。 三、施工方案中的各类施工,如涉及到需要办理停电第一种工作票时必须按规定报票。 四、较大型的施工项目,如需有关部门人员到施工现场的,应事先告知。 五、在施工过程中如需申请中间验收的应及时通知相关部门人员组织中间验收,并妥善保管中间验收结论。 六、工程完工后申请竣工验收,经验收合格后,办理竣工报告及移交相关资料等。

编制/日期:审核/日期:会审/日期:

批准/日期: 1 概况:为了进一步保护证电网的安全运行,提高供电可靠性,根据上级的工作安排,我们对35kV金熊变电站进行综自改造。具体内容为: 1.1 新增屏位基础及屏底电缆沟施工,室外电缆沟改造。 1.2 后台安装调试。 1.3 更换35KV主变保护测控屏、公用柜屏、直流屏、交流屏。1.4 新增35KV线路保护测控屏、远动屏、不间断电源柜。 1.5 更换10KV所属馈线保护装置8套及CT 9组,更换10VPT。

1.6 更换室外端子箱为不锈钢端子箱,新增检修端子箱。 1.7 更换相应的二次电缆。 1.8 室外电缆沟改造。 1.9更换站变为S11-100/35型。 1.10执行反措:屏柜接地铜排环状连接接地、CT二次N级在端子箱接地、PT二次N级引至保护屏接地、等等。 为了安全、优质、按时地完成此项工程,特编制本方案。 2组织措施: 2.1 工作负责人:xxx。 负责该项工程施工的组织、协调,根据工程进度调整工作计划和组织验收施工质量,保证工程进度和工程质量。督促全体工作人员认真执行安全措施,确保安全生产。 2.2 现场负责人:别必举。 负责该项工程施工的组织、协调。工作负责人不在现场的时候,履行工作负责人职责。 2.3 现场安全负责人:王卫华。 职责:督促全体施工人员认真贯彻执行国家颁布的安全法规,及企业制定的安全规章制度;深入现场每道工序,掌握安全重点部位的情况,检查各种防护措施,纠正违章指挥,违章作业,并建立违章作业登记;参加项目经理组织的定期安全检查,查出的问题要督促在限期内整改完成;发现危险及危害职工生命安全的重大安全隐患,有权力制止作业,并组织施工人员撤离危险区域;负责检查现场所做的安全措施是否符合实际,并做好危险点的分析与控制。 2.4 一次工作负责人:田刚。

当格田一二级水电站增效扩容改造工程施工自检报告DOC

普安县当格田一、二级水电站增效扩容改造35kV线路工程施工管理工作报告 贵州江河水利电力建设工程有限公司 二0一六年十二月

普安县当格田一、二级水电站增效扩容改造35kV线路工程施工管理工作报告 批准: 校核: 编制: 贵州江河水利电力建设工程有限公司 二0一六年十二月

目录 一、工程概况 1、改造前的情况 2、工程建设规模及任务 3、35kV线路改造工程施工设计情况 三、主要施工工艺及完成情况 1、施工工艺 2、工程实施完成情况 三、施工组织及安全管理 1、施工组织机构设置及管理体系 2、施工安全管理 五、施工质量管理 1、施工实施阶段的质量控制主要方法和措施 2、工程的项目划分 3、工程质量评定 六、工程结算 1、合同价款与实际结算价款 2、工程结算价超工程承包价的主要原因 七、自检自评结论 附件:工程施工管理大事记

一、工程概况 1、改造前的情况 由于当格田一、二级水电站建成运行了40多年,当格田一级水电站改造前总容量为1140kw, 当格田二级水电站改造前总容量为总容量为4440kw,电站设备老化严重,问题多多,存在诸多安全隐患,严重地危及到电站的安全运行。为了消除安全隐患,必须对当格田二级水电站进行更新改造,并根据实际情况适当扩容,增加电站的经济效益。特别是当格田二级水电站的35KV联网线路采用LGJ-50导线,电线杆基本上为8~12m的拔稍杆,对地距离低,事故率相对高。对原35KV线路进行改造是很有必要性的。 2、工程建设规模及任务 2012年8月黔西南州水务局,以州水务字【2012】79号文,对《普安县当格田一、二级水电站增效扩容改造工程初步设计报告》进行了批复。当格田一级水电站本次增效扩容装机为2230KW,多年平均发电量将达到804万kw.h,年平均利用小时3605 h。当格田二级水电站本次增效扩容装机为4790KW,多年平均发电量将达到1897万kw.h,年平均利用小时3960 h。 电站至铅矿变35kV线路改造工程是当格田一、二级水电站增效扩容改造项目的建设任务之一。初设阶段选用导线截面为120mm2型号为LGJ-120/20型钢芯铝绞线,进线段地线选配GJ-35型镀锌钢绞线,并按12.8km进行估算投资,估算投资为

XXX水电站增效扩容改造工程概算

X X X水电站增效扩容改造工 程概算 -标准化文件发布号:(9456-EUATWK-MWUB-WUNN-INNUL-DDQTY-KII

A9湖南省XXX市XXX水力发电站增效扩容改造工程概算 (送审稿) XXX市水利水电勘测设计院 二○一二年六月

项目名称:XXX市XXX水力发电站增效扩容改造工程审定: 审查: 校核: 编写: 设计人员:

目录 1. ··································································································································一 、概算正件......................................................................错误!未定义书签。2. . (1) 、编制说明······································································错误!未定义书签。3. ·································································································································· 工程概况··········································································错误!未定义书签。4. ·································································································································· 主要工程指标··································································错误!未定义书签。5. ·································································································································· 编制原则和依据······························································错误!未定义书签。6. ·································································································································· 定额依据··········································································错误!未定义书签。7. ·································································································································· 编制办法及费用标准 ······················································错误!未定义书签。8. ·································································································································· 其他说明··········································································错误!未定义书签。9. ·································································································································· 基础单价··········································································错误!未定义书签。10.································································································································· 取费 ·················································································错误!未定义书签。11.································································································································· 其他费用··········································································错误!未定义书签。

水电站增效扩容改造初步设计报告

水电站增效扩容改造初步设计报告

目录 1 工程概况 (1) 1.1 工程所在区域自然、社会、经济概况.. 1 1.3 改造方案综述 (2) 2 现状分析及改造必要性评价 (7) 2.1 现状分析 (7) 2.2 增效扩容改造的必要性 (10) 3 水文分析及水能复核 (14) 3.1 水文资料分析在整理 (14) 3.2 水能复核计算 (14) 4 工程地质 (15) 4.1自然地理、地形地貌、区域地质简况 . 15 4.2 工程地质条件及评价 (15) 5 工程任务及规模 (17) 5.1 等级划分及洪水标准 (17) 5.2 复核工程任务 (17) 5.3 特征水位复核 (18) 5.4 装机容量选择 (18) 6 增效扩容改造设计 (19)

6.1 水工建筑物改造 (19) 6.2 机电设备改造 (21) 6.3 金属结构改造 (30) 6.4 送出工程改造 (30) 6.5 其他工程 (30) 7 工程管理 (31) 7.1 工程管理机构 (31) 7.2 运行管理方案 (34) 8 施工组织 (39) 8.1 施工条件 (39) 8.2 施工导流 (40) 8.3 主体工程施工 (40) 8.4 施工总布置 (40) 8.5 施工总进度 (40) 9 工程概算和经济评价 (43) 9.1 工程概算 (43) 9.2 经济评价 (49) 附件一初步设计概算 附件二初步设计图纸

附件三检验测试报告

1 工程概况 1.1 工程所在区域自然、社会、经济概况 1.1.1 自然地理概况 XX地处XX北部,沂沭泗水下游,属鲁南丘陵与江淮平原过渡带。县域介于北纬33°53′至34°25′,东经118°30′至119°10′之间,东西60公里,南北55公里。东与XX接壤,南与淮安市毗邻,西倚XX,北接徐州,是徐、连、淮、宿四市结合部。全县地形呈不规则方形,地势西高东低,大部分地面高程在7-4.5米。县内最高峰韩山海拔70米,除潼阳、茆圩、刘集、悦来等乡镇有些岗岭外,土地平衍,河网密布,有新沂河、淮沭XX等29条河流纵横境内。 XX属于暖温带季风气候,全境气候温和,四季分明,日照充足,雨量丰沛。年平均气温13.8℃,年平均最高气温14.3℃,最低13.3℃。历年最高气温一般在35℃~38℃之间,最低气温在-4℃~-5℃左右。年平均日照时数2363.7小时,年平均相对湿度为75%,年平均风速为2.8米/秒,年平均降水量937.6毫米。 1.1.2 社会经济概况 XX县地处XX北部,隶属地级XX市,辖35个乡镇(场),县域面积2298平方公里,耕地204万亩,人口176万,是全省人口最多、陆域面积最大的县。 XX是中国花木之乡、全国十大商品粮基地县、全国农副产品生产大县、平原绿化先进县,全国著名的蔬菜生产基地、新兴食用菌生产基地、木材加工基地和著名的图书集散中心。。“十一五”末,全县实现地区生产总值288亿元,城镇居民人均可支配收入、农民人均纯收入分别达12900元、6875元。 1.2 工程现状及历年运行情况 1.2.1 工程现状 XX水电站位于XX市XX县XX镇蔷薇河村与XX市XX县XX镇交界,地处沭XX尾,下游为XX河,主要利用灌溉水发电,工程于1986年5月竣工,7月并网发电,减轻地方电网供电压力,另兼顾灌、排水,设计流量为25m3/s。2010年对1#-3#机组拆除更换新机组、2011年4月并网发电。 水电站现装有5台发电机组,1#、2#、3#机组单机装机容量为125kw,发电

范本1:变电站综自改造类“三措一案”

范本1:变电站综自改造类“三措一案” 南京***变电站综自系统改造工程 施工方案及施工组织、技术、安全措施 批准: 审核: 编制: ******安装有限公司 二○一五年三月

目录 一、工程概况 (3) 二、工作任务及内容 (3) 三、编制依据 (3) 四、施工方案 (4) (一)施工前工作要求 (4) (二)施工总计划 (4) (三)第N阶段:220kV大雨2561间隔改造 (5) 五、施工三措 (6) 1、组织措施 (6) 2、技术措施 (7) 3、安全措施 (9) 六、应急预案 (11) 附件1:现场施工通道平面图

一、工程概况 工程名称:…………………… 工程地点:…………………… 建设单位:…………………… 监理单位:…………………… 设计单位:…………………… 施工单位:…………………… 项目简介:本工程一次设备更换220kV旁路间隔电流互感器共3台,型号AGU-252,变比为2*800/5,六次级,为特变电工康佳(沈阳)互感器有限责任公司产品…………… 二、工作任务及内容 (注意:若工程内容相对简单,则可将本部分并入工程概况) 2.1公用系统: (1)保护室前排新增盘位28个,含两个备用房间改造为电缆半层(土建专业)…………………… 2.2主变系统: (1)新增1号、2号主变保护、测控及辅助柜8面,分别为:主变保护A柜2面;主变保护B柜2面……………… 三、编制依据 (注意:根据具体工程应用相关标准,勿简单罗列) GB50169-2006《电气装置安装工程接地装置施工及验收规范》 ………………………………

四、施工方案 (一)本工程施工技术及安全要求 4.1.1技术交底 1.需交底安全注意事项: (1)在现场发生或发现的危及施工安全、设备安全时,任何人有权及时制止并上报,对施工过程中造成的设备细小损伤任何人不得隐瞒不报或延时汇报……………… 2.结合以往施工中存在问题,特别强调几点: (1)所有设备拆除前须将其二次接线解开,拆线前须对电缆铭牌(规格、型号、起讫端等)进行核对与确认。 ……………………………………… 4.1.2专项技术措施 1.由于在运行中变电站进行查线工作,只允许打开各屏柜后门,不得接触装置本体,尽量避免触动屏后接线,不得拆接二次回路接线,不得大力拉扯二次回路接线……… 4.1.3通用技术措施 1.必须按设计图纸和厂家安装说明书进行施工,禁止擅自修改图纸,如有改动,必须征得有关部门同意,并且改动图纸做好记录…………………… 4.1.4配合要求 1.本工程工作绝大多数均在运行设备上工作,工作量及工作周期较长,与运行设备搭接前电缆均要排放到位,同时要求运行及检修单位全力配合并检查确认接线位置。 2.要求后台监控厂家于停电改造前1个星期进驻现场,进行后台信息改造及配合调试…………………

220kV变电站综自改造问题及对策研究

220kV变电站综自改造问题及对策研究 发表时间:2016-07-04T14:28:41.523Z 来源:《电力设备》2016年第7期作者:刘宝 [导读] 变电站综自改造工作始自上世纪90年代,发展至今已经有了比较成熟的经验。 刘宝 (宁夏回族自治区电力设计院 750002) 摘要:随着计算机、通信、监控技术的飞速发展,新建的110kV及以上变电站均实现综合自动化,原有的常规站也将实施综合自动化改造,本文主要研究220kv变电站综自改造问题和解决对策,分析了220kv变电站综自改造工作中存在的主要问题,并对其解决措施进行了分析。 关键词:变电站;综自改造;对策 变电站综自改造工作始自上世纪90年代,发展至今已经有了比较成熟的经验,变电站综合自动化系统随着计算机技术、调度通信技术以及继电保护技术的不断发展,在软硬件以及系统控制方面有取得了较大的进步,无人值守变电站成为可能,减少了电力系统变电站的人力劳动,为现代化智能电网远程集控变电站建设提供了技术支持。电力系统运行实际情况证明,变电站综合自动化技术的广泛应用显著提高了变电运行的可靠性,能够为集控中心提供变电站实时、全面、准确的运行状态信息,为电力调度提供更加详实的基础数据。 一、220kv变电站综自改造过程中出现的问题 现阶段,220kv变电站综自改造过程中存在的问题主要集中在五防、同期电压、数据通讯、停电时间协调等方面。 (一)五防系统问题 传统的变电站采用主机、电脑钥匙、机械编码锁、电气编码锁、模拟显示屏组成的传统微机五防系统,这种传统的变电站控制系统无法和现代化的智能化设备进行有效的数据通信,无法向监控系统发出明确的遥控指令实现防误触闭锁功能,在要求改造为综合自动化变电站控制系统之后,设置了遥控功能,因此防误触保护系统也需要进行适当的改造,形成一体化后台监控模式,将五防系统作为监控系统的一部分嵌入监控系统中,使用测控网络防误触闭锁功能,实现间隔连锁以及调度端遥控操作防误闭锁。 (二)综自系统同期电压 传统变电站同期合闸使用控制屏同期表判定是否同期,比较母线电压互感器试验电压和线路电压压差、频差、角差,综合自动化改造之后,将不能使用这种判断方法,需要将同期功能分解在各条线路的测控装置上,比较A相母线以及线路电压的比较确定是否同期。 (三)智能保护装置和监控中心的通信 变电站的保护装置可能有多种型号,由多个厂家生产,通信接口形式不一,传统变电站上的很多保护设备都不能接入新的监控系统,无法提供和新建综自系统相匹配的IEC61850规约接口,因此在变电站综自改造过程中,需要及时更换原有设备的通信插件,或者增设通信管理机,提供标准规约接口接入集控系统。 (四)停电时间协调 停电难是所有变电站综自改造都面临的问题,为了进一步优化停电计划,负荷高峰季节,优先选择一些非单供电线路如TV、电容器开展停电改造,将单供电线路如10kv线路的停电改造工作安排在负荷较小的季节开展。与此同时,在设备停电之前,需要做好必要的准备工作,尽量缩短停电时间,可以在停电之前预先安装好辅助设备,敷设好二次线缆,并提前打印出电缆号牌和标签,做好停电安装的准备,停电之后立即开始改造接线,确保每天线缆都能够在1天内完成设备安装和调试工作,尽快恢复供电,减少对用户的影响。 二、220kv变电站综自改造问题解决策略 (一)整体思路 为了避免综自改造对系统的稳定性造成影响,在增加综自系统的同时保留原有管理机,选择其中一台管理机作为从站接入新综自系统的数据通信处理单元,维持后台系统、保护系统、运行监测系统现状,逐步接入新系统,并将原有系统有序退出。新增综自系统使用主控层和间隔层的双以太网结构,增强系统的传输能力,同时采用双机双主配置的CSM320E远动管理机,获得适应性更强的功能接口,程序版本升级安全稳定,通过改造形成主站原有管理机和综自系统之间有效的数据通信,合并信息,并将处理后的信息根据不同规约发送给不同级别调度。 (二)管理机 1、连接方式 选择以太网RS232、RS485/422接口连接,选择RS485时因为需要增加CSM320E侧的转换头,会导致运行维护共工作量增加,所以不建议选择这种接口。以太网连接方式应该升级DF1710A管理机,避免后续升级对系统运行造成影响。 2、管理机选型 变电站原有的管理机一般都能够和CSM320E建立稳定的通信,但是为了进一步提高连接稳定性,降低连接难度,需要从原有管理机中选择一套合适的进行配置。 图1 管理机逻辑接线 (1)双机配置 管理机应该采用双机热备的工作形式,两组机器互为备用,保证过渡期综自系统运行稳定,不能够实现双机热备的管理机不能留用。 (2)管理机组态配置 分析远动管理机以及运行控制器组态配置,如果远动管理机作为CSM320E的连接枢纽,应该在管理机上加装连接链路,重建全信息组态,造成了很多重复劳动,工作量很大,而且因为信息点中没有中文标识,可能会在编辑数据库时出现错误。而管理机如果使用以太网汇集原有综自系统信息,就能够获得比较完整的信息量,使用终端维护软件直接查看管理机组态信息即可,能够获得基本完整的信息数据库,其他串口可以采用数据库复制的方式获得转发表,适当调整接入协议,接入难度得到了显著降低。

浅析小水电站增效扩容改造——以南宁市武鸣区西江水电站增效扩容

浅析小水电站增效扩容改造——以南宁市武鸣区西江水电站增效扩容改造工程为例 发表时间:2017-07-19T16:48:31.387Z 来源:《基层建设》2017年第9期作者:杨琳 [导读] 摘要:为确保小水电站增效扩容改造项目实施的管理,加快水电站改造项目的建设速度,国家对小水电站进行增效扩容方面做了大量的工作,出台了一系列水电站改造资金补助的政策。 南宁市武鸣区西江引水工程管理所广西南宁 530199 摘要:为确保小水电站增效扩容改造项目实施的管理,加快水电站改造项目的建设速度,国家对小水电站进行增效扩容方面做了大量的工作,出台了一系列水电站改造资金补助的政策。这些政策的实施极大地改善了投产早、效率低、技术落后、安全程度低的水电站,并且使得有限的水资源得到了有效的利用与发展,有效的保证了水电发展的需求。本文主要就是根据实践工作经验了解水电站增效扩容改造的相关内容。 关键词:小水电站;增效;扩容;改造 1工程概况 武鸣县西江水电站位于南宁市武鸣县城厢镇共和村,距离武鸣县城11km,电站于1975年12月兴建,1977年3月投入运行,西江水电站是一座坝后式水电站,装有4台立式水轮发电机,机组发电是与大网联网运行,总装机容量为1640kw(2台×320+2台×500),多年平均发电量为661万kW.h,设计年利用小时4020小时,设计水头10m,设计引用流量为21.04 m3/s,本次增效扩容将电站装机容量1640(2×320+2×500)kW增至(2×400+2×650)kW,总装机容量达到2100 kW,多年平均发电量为746.4万kW.h,年利用小时3560小时,多年平均发电量比改造前增加85.4万kW.h,设计水头10m,设计引用流量为25.12m3/s。 2水电站存在的主要问题 2.1设备老化,发电效率降低 武鸣县西江水电站机电设备经过30多年运行电设备功能效率一般,自动化程度很低。机组及其附属和公用辅助设备性能大幅下降、效率低下、水能利用率降低、故障频发。电气设备老化严重,相当一部分自动控制功能已丧失,继电保护的速动性、灵敏性、可靠性明显降低,在很大程度上影响了主设备的安全、稳定运行。另外,由于电站建设投产较早,电站水轮机调速器、发电机励磁系统、各种基础自动化元件、电气设备、监控设备、继电保护设备等受当时制造工艺和技术水平的限制,电站综合自动化水平很低。 2.2水轮机的运行效率较低,参数性能十分落后 武鸣县西江水电站于1975年12月兴建,在技术以及设备方面依然十分落后,特别是对水轮机的水力模型的开发依然处于落后的水平,还依赖于国外的先进技术,早期的水电站所采用的水轮机型号均为苏联或者美国等发达国家所研制的机型,这些机型在某些地方的小型水电站中依然在使用,但是与现代化的技术水平相比,传统的水轮机在转速以及容量方面效率依然很低,而且水轮机的水力稳定性与安全性能较差。 2.3水工建筑物破损失修,安全隐患增多 水工部分建筑物已经比较陈旧,钢门窗锈蚀,木门窗霉烂变形,面层剥离。水轮发电机组、变压器、户外断路器、低压配电设备、电力电缆、监控系统、励磁系统等机电设备已超使用年限,机组出力不能达到额定出力、机电设备老化、运行不稳定、故障率高,自动化程度低等问题,曾出现过一些影响电站正常安全运行的问题和隐患。 3水电站开展增效扩容的必要性 由于明秀水电站现状已影响了安全经济运行和水力资源的充分利用,因此开展小水电站增效扩容改造工程十分有必要。 3.1恢复发电能力 开展农村水电增效扩容改造工程,可在相当大程度上恢复电站生机活力,重新发挥应有的经济效益。电站虽然存在着很多的问题,尤其在设备上,但运行基础条件还在,对主要水轮发电机组设备进行更换,相对来说,以较少的投入达到水电站增效的目的,提高了发电效益。 3.2发挥环境和社会效益 增效扩容改造后,在充分利用清洁能源,解决农村电力供应的同时,对改善农村基础设施和生产生活条件,促进本地农村经济可持续发展以及减少污染物排放等方面发挥了重要作用,得到了本地老百姓的普遍认同。 3.3改善小水电站安全现状 开展小水电站增效扩容改造工程,也有利于改善小水电站的安全现状。小水电站普遍超期服役,主要设备老化、运行不稳定,存在着诸多安全隐患,给小水电站的安全运行和管理带来较大压力。对小水电站的主要设备进行更新改造,彻底消除安全隐患,能大大改善小水电站安全现状,保障小水电站安全运行。 4工程主要任务 本次增效扩容工程主要建设内容为:对厂房内外墙及门窗进行维修更新约1800m2。更换水轮机转轮4台。更新发电机定子、转子线圈4套。更换调速器、励磁装置各4台。新装计算机监控系统1套。更换直流系统2面。更换保护屏、控制屏15面。更换主变压器2台。更换高压屏11面。更换控制电缆3000m;更换电力电缆2100m。 5设计变更情况 5.1一般变更 变更2台主变压器型号。根据变压器生产厂家说明,10kV变压器型号“/”后标的电压等级应为10,且目前国内变压器生产厂家对6300kVA以下户外变压器一般不需增设风扇强制降温,故1#主变压器型号由SF11-1250/11更改为S11-1250/10, 2#主变压器型号由SF11-2000/11更改为S11-2000/10。已由设计单位核定; 取消厂房工程的厂房外墙除料项目,增加厂房屋顶防水工程施工; 取消厂房工程的9扇门,增加厂房大门密封处理; 取消厂房工程的发电机房隔热门及厂区内铺种草皮施工项目,增加厂房厨房窗户封闭处理;取消厂区水泥道路施工项目,增加高压室户外平整硬化;

XXX水电站增效扩容改造工程概算

A243004369 湖南省XXX市XXX水力发电站增效扩容改造工程概算 (送审稿) XXX市水利水电勘测设计院 二○一二年六月

项目名称:XXX市XXX水力发电站增效扩容改造工程审定: 审查: 校核: 编写: 设计人员:

目录 1.一、概算正件 (3) 2.1、编制说明 (3) 3. 1.1 工程概况 (3) 4. 1.2 主要工程指标 (3) 5. 1.3 编制原则和依据 (4) 6. 1.3.1 定额依据 (4) 7. 1.3.2 编制办法及费用标准 (4) 8. 1.4 其他说明 (4) 9. 1.4.1 基础单价 (4) 10.1.4.2 取费 (6) 11.1.5 其他费用 (8) 12.1.5.1 设备及安装工程 (8) 13.1.5.2 独立费用 (8) 14.1.5.3 预备费及其他 (9) 15.1.6 资金筹措方案 (9) 16.1.7 主要工程指标表 (9) 17.1.8 工程概算总表 (10) 18.2.工程部分概算表 (12) 19.2.1 概算表 (12) 20.(1)总概算表 (12) 21.(2)建筑工程概算表 (13) 1 XXX市水利水电勘测设计院

22.(3)机电设备及安装工程概算表 (14) 23.(4)金属结构设备及安装工程概算表 (15) 24.(5)施工临时工程概算表 (15) 25.(6)独立费用概算表 (16) 26.2.2 概算附表 (17) 27.(1)建筑工程单价汇总表(附表一) (17) 28.(2)安装工程单价汇总表(附表二) (19) 29.(3)主要材料预算价格汇总表(附表三) (20) 30.(4)次要材料价格汇总表(附表四) (21) 31.(5)施工机械台时费汇总表(附表五) (23) 32.(6)主要工程量汇总表 (25) 33.(7)主要材料量汇总表 (26) 34.二、概算附件 (27) 35.1、主要材料预算价格计算表 (27) 36.2、施工用电价格计算表 (28) 37.3、施工用水价格计算表 (28) 38.4、施工用风价格计算表 (28) 39.5、混凝土和砂浆材料单价计算表(附件六) (29) 40.6、施工机械台时费计算表 (30) 41.7、建筑工程单价表 (34) 42.8、安装工程单价表 (44) 2 XXX市水利水电勘测设计院

水电站增效扩容改造施工管理报告

XXXXX 水电站增效扩容改造工程土建施工管理报告

XX水利水电工程有限公司XXXXX 水电站增效扩容改造工程 二O—四年九月 批准: 审核: 编写:

XX水利水电工程有限公司XXXXX 水电站增效扩容改造工程 二O—四年九月 目录 第一章工程概况 (1) 1.1 工程简介. (1) 1.2 参建单位. (3) 第二章施工总布置、总进度和完成的主要工程量 (4) 一、施工总布置 (4) 四、完成主要工程量 (5) 第三章主要施工方法 (7) 一、主要施工参照标准 (7) 第四章施工质量管理 (9) 一、施工组织和质量保证体系 (9) 二、现场质量控制情况 (10) 三、工程施工质量综述 (10) 四、质量事故与质量缺陷 (10) 第五章文明施工与安全生产 (11) 一、安全体系 (11) 二、安全生产责任制 (11) 2、安全管理工作职责 (11) 3、安全技术管理 (12) 第六章结语 (13) 附件1:工程施工管理大事记. (14)

附件2:施工管理机构及主要工作人员 (15) 附件3:质量保证体系机构图. (16)

第一章工程概况 1.1 工程简介 XXX位于福建省中部,戴云山脉西侧;地处北纬25028’ 53〃? 26o09‘ 42〃,东经117028’ 58〃?118o03‘ 13〃;东邻德化,西靠永安,南连永春、漳平,北与三元、沙县、尤溪接壤;东西最宽57公里, 南北最长75公里,总面积2294平方公里,占福建省总面积的1.89%。 本县地形属山区丘陵地带,境内山峦蜿蜒,高峰竣立,沟涧密布。地势大致由西南向东北倾斜,主要地貌形态有中山、低山、高丘、低丘、河谷平原和山间盆谷六大类。山岭、谷地颁有明显的方向性,与境内构造基本一致。海拔千米以上的山峰有99座,最高山峰是南部屏山乡内的大仙峰,海拔1553米,西部的琴山海拔1212米,中部的高峰山海拔1282米,构成了以中、低山为主体的地貌类型。东北部较低,最低点为梅山乡的沧州村,海拔仅210 米,县城海拔350 米。 自然资源十分丰富。矿产资源品种多、储量大,位居福建省前列,是全国首批百个重点产煤县、福建省十大重点矿区和五大重点铁矿区之一,也是福建省水泥生产第二大县。XXX属于中亚热带季风气候,多年平均气温在15.3-19.6 C,多年平均降雨量1492-1810毫米,径流深度为853毫米左右,水能资源较为丰富,汇水面积30 平方公里以上河流24 条,全县水能资源理论蕴藏量为20.76 万千瓦,可开发小水电装机容量为17.6 万千瓦,已开发14.663 万千瓦,占可开发量的83.3%,年发电量已达5亿千瓦时。境内地下水资源总量为3.54 亿吨/年,地热热能资源储藏较丰富, 温泉流量较大,水温高。全县森林覆盖率77%,森林蓄积量637.92 万立方米,县内胜迹景观遍布。

相关主题