过 程 能 力 研 究
(CPK分析报告)
UCL16.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.1816.18 X15.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.9915.99 LCL15.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.8015.80 UCL0.693285710.69328570.69328570.69328570.69328570.69328570.69328570.6932860.6930.693285710.69328570.693285710.693285710.693285710.69328570.69328570.69328570.69328570.69328570.69329 R0.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.3290.329 LCL00000000000000000000研究评定: 由以上计算结果可知CPK=1.365>1.33,性能指数能够满足.若批准,开始生产并按照已批准的控制计划进行.
16.1815.9915.800.693285714
0.329
* 连续7点全在中心线之上或之下。* 连续7点上升或下降。
* 任何其它明显非随机的图形。
* 任何超出控制限的点。
分析报告)