A R EVIEW OF P OWER C ONVERTER T OPOLOGIES FOR W IND G ENERATORS

J. A. Baroudi, Student Member, IEEE , V. Dinavahi, Member, IEEE and

A. M. Knight, Member, IEEE ,

Dept. of Electrical and Computer Engineering

University of Alberta

Edmonton, AB, T6G 2V4, Canada

Abstract - Wind energy conversion systems have become a focal point in the research of renewable energy sources. This is in no small part due to the rapid advances in the size of wind generators as well as the development of power electronics and their applicability in wind energy extraction. This paper provides a comprehensive review of past and present converter topologies applicable to permanent magnet generators, induction generators, synchronous generators and doubly fed induction generators. The many different generator-converter combinations are compared on the basis of topology, cost, efficiency, power consumption and control complexity. The features of each generator-converter configuration are considered in the context of wind turbine systems.

I. I NTRODUCTION

Power extracted from wind energy contributes a significant proportion of consumers’ electrical power demands. For example, 20% of the entire electricity consumption in Denmark is provided by wind energy [1]. In recent years, many power converter techniques have been developed for integrating with the electrical grid. The use of power electronic converters allows for variable speed operation of the wind turbine, and enhanced power extraction. In variable speed operation, a control method designed to extract maximum power from the turbine and provide constant grid voltage and frequency is required. A wide range of control schemes, varying in cost and complexity, have been investigated for all the previously considered conversion systems. All control schemes integrated with the power electronic converter are designed to maximize power output at all possible wind speeds. The wind speeds range from the cut-in speed to the rated wind speed, both of which are specific to the size and type of generator used in the wind energy conversion system (WECS).

In this paper, the possible combinations of converter and generator topology for permanent magnet generators, caged rotor induction generators, synchronous generators and doubly fed induction generators including more specifically wound rotor induction machines are discussed and some of the possible control strategies are touched upon. This paper serves as a concise summary and comparison of the state of art regarding power electronic topologies and wind energy conversion systems.

0.0

0.1

0.2

0.3

0.4

2

4

6

8

Tip-Speed to Wind Ratio

C o e f f i c i e n t o f P o w e r

10

Fig. 1. Typical Coefficient of Power Curve

II. W IND E NERGY B ACKGROUND

The amount of power captured from a wind turbine is specific to each turbine and is governed by:

3

12

t p P AC v ρ=w A , (1)

where P t is the turbine power, ρ is the air density, A is the swept turbine area, C P is the coefficient of performance and v w is the wind speed. The coefficient of performance of a wind turbine is influenced by the tip-speed to wind ratio or TSR given by

w

r TSR v ω=, (2) where ω is the turbine rotational speed and r is the turbine

radius. A typical relationship, as shown in Fig. 1, indicates that there is one specific TSR at which the turbine is most efficient [2]. In order to achieve maximum power the TSR should be kept at the optimal operating point for all wind speeds. The turbine power output can be plotted versus the turbine rotational speed for different wind speeds, an example of which is shown in Fig. 2. The curves indicate that the maximum power point increases and decreases as wind speed rises and falls. In the following sections, the various generator-converter combinations that are able to obtain maximum power output for varying wind speeds are discussed.

_______________________________________________

The funding for this work, from the Natural Sciences and Engineering Research Council (NSERC) of Canada is gratefully appreciated. 0-7803-8987-5/05/$20.00 ?2005 IEEE.458

0500100015002000250030000

200

400

600

800

1000

1200

1400

Generator Speed (rpm)

T u r b i n e P o w e r (k W )6m/s

8m/s

10m/s

12m/s 16m/s

14m/s

Fig. 2. Turbine Output Power Characteristic

III. P ERMANENT M AGNET S YNCHRONOUS G ENERATORS

Permanent magnet excitation is generally favored in newer smaller scale turbine designs, since it allows for higher efficiency and smaller wind turbine blade diameter. Whilst recent research has considered larger scale designs, the economics of large volumes of permanent magnet material has limited their practical application. The primary advantage of permanent magnet synchronous generators (PMSG) is that they do not require any external excitation current. A major cost benefit in using the PMSG is the fact that a diode bridge rectifier may be used at the generator terminals since no external excitation current is needed. Much research has been performed using the diode rectifier [3-10,13-15]; however, this leaves many options for the remainder of the power converter and its control, some of which are shown in Fig. 3.

A. T HYRISTOR S UPPLY -S IDE I NVERTER

Using a thyristor based grid-side inverter allows continuous control of the inverter firing angle, regulating turbine speed through the DC-link voltage; hence, obtaining optimum energy capture [3]. Advantages of this scheme include lower device cost and higher available power rating than hard-switched inverters. A major drawback to this inverter is the need for an active compensator for the reactive power demand and harmonic distortion created, as shown in Fig. 3a. A voltage source converter (VSC) is used for the compensator and the error signal between the reference and actual compensator current is used to drive the pulse width modulated (PWM) control [3].

B. H ARD -S WITCHED S UPPLY -S IDE I NVERTER

Various control strategies that can be applied to the converter in Fig. 3b have been discussed [4]. A proposed control involves the manipulation of the modulation index of the reference sinusoidal signal applied to the PWM generator. This is achieved by determining the DC-link voltage by a power mapping technique that contains the maximum power versus DC voltage characteristic. The control system is

further improved by using a derivative control on the stator

frequency, since it also changes with change in DC-link voltage [4]. This control is compared with Maximum Power Point Tracking (MPPT), which includes an anemometer, wind prediction control scheme and a fixed-voltage scheme. The anemometer measures the wind speed and aids in providing the wind power reference to the MPPT controller. The reference power is compared to the actual DC power extracted in which the result is used to determine the new operating DC voltage. The current control loop of the inverter receives the new operating DC voltage and outputs an instantaneous driving signal for the PWM [4]. In wind prediction methods, autoregressive statistical models are commonly used. The system considers energy captured in the previous time frame to predict the wind speed value for the next time frame set. Under fixed-voltage control, the voltage of the inverter is fixed at a targeted optimum wind speed. In comparing the four control methods, the fixed voltage scheme was used as the reference since it was the least efficient. The MPPT with anemometer setup proved to be superior, obtaining 56-63% of energy available. However, the proposed method using sensor-less control was not far behind, obtaining 55-61% of the total energy available from the wind.

C. I NTERMEDIATE DC/DC C ONVERTER S TAGE

The use of a voltage source inverter (VSI) accompanied by a DC/DC converter is investigated [5,6], depicted in Fig. 3c. This setup is also compared to the converter shown in Fig. 3b [7]. Incorporating an extra DC/DC converter gives the following advantages:

459

1. Control of generator-side DC-voltage through

variation of the switching ratio

2. Maintains appropriate inverter-side DC-voltage

3. Allows for Selective Harmonic Elimination (SHE)

switching, giving reduced losses

4. Inverter no longer needs to control DC-voltage, and

has more flexible control

The inverter power control can be achieved by regulating the magnitude of the fundamental line current and the phase angle between the line current and line voltage [5]. The controller is configured such that the VSI is switched at the frequency of the triangular carrier signal and its output harmonics are well defined. In [6], for every shaft speed, optimum values of DC voltage and current can be identified corresponding to the maximum available turbine power. The DC/AC voltage ratio and power angle are used as control

variables that are tuned to control the power, and ultimately the speed of the generator. The inverter control can also be implemented to keep the DC-link constant and vary the reactive power in a manner that attains maximum real power transfer to the grid [6]. Results show that the thyristor based inverter with active compensator is best suited for strong AC systems since it relies on the system to ensure commutation [6]. However, both the VSI and DC/DC-VSI systems are capable of integrating with both strong and weak ac systems. Other control strategies have been discovered for this converter [8,9]. The DC/AC inverter can control the active and reactive power delivered to the grid via control of the q-axis and d-axis current respectively [8]. The q-axis reference current is determined by the error in the DC-link voltage, and is then compared with the actual current. The phase angle of the utility, used in power factor control, is detected using software phase lock loop (PLL) in a d-q synchronous reference frame. Power factor control creates the d-axis reference current allowing it to be compared to the actual d-axis current. The error in both reference frame currents are used to create the d-q axis reference voltages used in space vector PWM control. Using the voltage equation governing a boost-up DC/DC chopper and a proportional-integral (PI) controller, the duty ratio of the chopper switch may be determined for any particular optimum point [8]. The inverter-side DC voltage remains constant set by the grid voltage giving the advantage of flexible transfer of active and reactive power to the grid. A slight modification to the DC-link shown in Fig. 3c is made by including a battery. The battery allows charging during night time when load demand is usually lower. An immediate advantage is a constant DC-link voltage; therefore controlling the chopper output current to its maximum value giving maximum output power [9]. To perform the control a relationship between the output power and duty cycle of the chopper is used. Starting from an arbitrary point, the duty cycle can be continuously and slowly adjusted between a

specific range searching for the maximum power point. It is

found that the control system began losing efficiency at high speeds; this was due to the phase lag between the DC current and duty ratio [9]. A faster sampling rate would help correct this problem.

D. B ACK -TO -B ACK PWM C ONVERTERS The use of two, 6-switch, hard-switched converters, with a DC-link capacitor, Fig. 4a, has been explored [10]. The generator side rectifier is controlled through a PI controller such that the d-axis current is held to zero to obtain maximum electrical torque with minimum current. A MPPT is used in determining the optimum rotor speed for each wind speed to obtain maximum rotor power. In contrast, the grid side inverter controls the line current to be sinusoidal through a hysteresis controller. The DC-link voltage is also controlled by a PI controller, via the grid side inverter [10]. More recently a converter using two B-4 converters and two DC-link capacitors has been developed, shown in Fig. 4b [11]. Again a MPPT calculates the output power of the generator by measuring the DC-link current and voltage, and then alters the operating point by increasing or decreasing the reference current magnitude. The MPPT control is performed on the generator side rectifier. The grid-side control sets the inverter current through a PI controller and the DC-voltage error. The current error is used to drive the inverter switching signals. A PLL is used on each side to ensure unity power factor is maintained throughout the entire system [11].

E. U NCONVENTIONAL S CHEMES A rather unconventional scheme using a PMSG has been discussed [12]. The system uses a rotary phase shifter (RPS) as a frequency converter. The RPS can adjust the angular velocity of the generator at a low cost in comparison to a power electronic device. A flywheel is also used as power stabilizer; it has a lifetime that is not limited unlike the use of a battery. As this is an uncommon method, more details can be found by reading [12].

460

Recently research has been performed to solve DC-link shortage problems under low wind speed conditions. By placing three switches between the diode rectifier legs and middle point of the DC-link capacitor, the voltage at low winds can be increased. During low wind speeds, the switches are turned on and off alternately, keeping the system symmetrical while increasing the voltage. The switches are not used during high winds to avoid frequent over-voltages. This is not a common practice but one worth noting, and further details can be found in [13]. Another modification to the converter system in Fig. 3b can be made to ensure energy flow is unidirectional; from generator to grid. By placing a simple diode in between the capacitive DC-link and the inverter, energy flow is restricted due to the reverse blocking capabilities of the diode [14].

IV. D OUBLY F ED I NDUCTION G ENERATORS

As the PMSG has received much attention in wind energy conversion, the doubly fed induction generator (DFIG) has received just as much consideration if not more. If a wound rotor induction machine is used, it is possible to control the generator by accessing the rotor circuits. A significant advantage in using doubly fed induction generators (DFIG) is the ability to output more than its rated power without becoming overheated. It is able to transfer maximum power over a wide speed range in both sub- and super-synchronous

modes. The DFIG along with induction generators are excellent for high power applications in the MW range. More importantly, converter power rating is reduced since it is connected to the rotor, whilst the majority of the power flows through the stator. A. S TATIC K RAMER D RIVE AND SCR C ONVERTER M ETHODS The Static Kramer Drive consists of a diode rectifier on the rotor side and a line commutated inverter connected to the supply-side [15], Fig. 5. With this converter, a sliding mode control is developed which provides a suitable compromise between conversion efficiency and torque oscillation smoothing. The controller regulates the thyristor inverter firing angle to attain the ideal compromise. The sliding mode control law forces the generator torque to be a linear function of the generator speed around the operating point of maximum power transfer [15]. This converter is only able to provide power from both stator and rotor circuits, under super-synchronous operation. To solve this problem, other methods replace the diode rectifier with another thyristor rectifier (SCR) [16,17]. The inclusion of a second SCR allows the generator reactive power demand to be satisfied by the rotor-side converter system. When connected to the wind turbine, it is show that optimum performance is obtained by adjusting the gear ratio, of the gear box, to its optimum value [16]. In comparison to the Kramer Drive, this system produces more power output due to the lack of reactive power available with

a diode rectifier. More detailed control of the two rectifiers is

given in [17]. A range of both firing angles for each mode of operation (sub- and super-synchronous modes) is given as a plot showing the optimum firing angle at different wind speeds giving greatest power transfer. It is discovered that between 7.5 and 8.5m/s, maximum power can be generated in both sub- and super-synchronous modes [17]. Major drawbacks of this approach include firing and commutation problems with the rotor-side converter and harmonic distortion to the grid, created by the supply-side thyristor converter.

B. B ACK -TO -B ACK PWM C ONVERTERS

A more technologically advanced method using back-to-back converters has been developed, Fig. 6. Much work has been presented using this type of converter [18-22]. Although the converter used in these works are extremely similar, great differences lie within the control strategy and complexity. One option is to apply vector control to the supply-side converter, with a reference frame orientated with the d-axis along the stator voltage vector [18,19]. The supply-side converter is controlled to keep the DC-link voltage constant through regulation of the d-axis current. It is also responsible for reactive power control through alteration of the q-axis current [18,19]. As for the rotor side, the choice of decoupled control of the electrical torque and the rotor excitation current is presented [18]. The machine is controlled in a synchronously rotating reference frame with the d-axis orientated along the stator-flux vector, providing maximum

461

energy transfer. Conversely, in [19], the rotor current was decomposed into d-q components, where the d-axis current is used to control the electromagnetic torque and the q-axis current controls the power factor. Both types of rotor-side converter control employ the use of PI controllers. PWM switching techniques can be used [18], or alternatively space vector modulation (SVM) used in order to achieve a better modulation index in [19].

Often control schemes aided by a rotor speed encoder obtain excellent tracking results. However these encoders are expensive and the cost due to lost accuracy without the encoder may not be as large. The use of speed sensors has been described [20,21]. To accompany the capacitor in the DC-link, a battery may be used as a storage device. With the extra storage device, the supply-side converter now controls the transfer of real power between the grid and the battery, as the DC voltage is now fixed [20]. The supply side controller is made up of three PI controllers, one for outer loop power control, and the other two for the d-q axis inner current control loop. Energy is stored during high winds and is exported to the grid during calm conditions to compensate for the drop in stator power. During long periods of high or low wind speeds, the control algorithm is modified to regulate the bus voltage until the conditions change. In this case the rotor-side converter is gated in order to control the real and reactive power of the machine. Another different option for rotor control has been identified [21]. The algorithm searches for the peak power by varying the rotor speed, and the peak power points are recognized as zero slopes on the power-speed curves. The control works continuously, as a significant shift in power causes the controller to shift the speed which in turn causes the power to shift once again. Once the change in power no longer exceeds the minimum set value, the controller takes no further action. Once again, d-q axis control is used to control the real and reactive power of the machine. It is important to ensure the dynamics of the speed controller are not extremely fast, else large transients in generator torque may occur [21].

The typical control objectives described above can be attained through control theory based on voltage space vectors (VSV). The application of certain voltage vectors may accelerate the rotor flux, and increase the active power generated by the stator. Other voltage vectors may also increase or decrease the rotor flux magnitude, resulting in a reduction in the reactive power drawn by the stator and an improved power factor. This direct power control method requires a series of tables to determine which of the six sectors the controller is operating in. From the choice of sector the applied voltage vectors can be determined from another table. The controller tables and details are provided in [22].

A final control scheme, for the back-to-back PWM converter scheme, uses information on shaft speed and turbine output power to estimate the wind speed [23]. The turbine output power is described as a function of TSR. The

roots of the equation are solved to determine the optimum

TSR within a specific range. With the estimated wind speed and optimal TSR, the new reference of the generator output power and shaft speed is obtained. The system is commanded to the desired shaft speed and the output power is again measured, regurgitating the control. This control is applied to a brushless DFIG, which gives reduced cost in comparison to machines with brushes and slip-rings [23].

C. M ATRIX C ONVERTER

The matrix converter is capable of converting the variable AC from the generator into constant AC to the grid in one stage, Fig. 7. Two distinct advantages arise from this topology, the converter requires no bulky energy storage or DC-link and control is performed on just one converter. The utilization of a matrix converter with a DFIG has been explored [24,25]. The use of a stator-flux oriented control was employed on the rotor matrix converter. The d-axis current was aligned with the stator-flux linkage vector. Simple PI controllers can be employed to control the d-q axis currents. The regulation of the d-axis current allows for control of the stator-side reactive power flow, where as the q-axis current helps regulate the stator-side active power [24]. Another option is to control the rotor winding voltage, which consequently manipulates the power factor of the DFIG [25]. The matrix converter consists of nine bi-directional switches (18 total), arranged in a manner such that any input phase may be connected to any output phase at any time. Each individual switch is capable of rectification and inversion. The matrix converter is controlled using double space vector PWM, employing the use of input current and output voltage SVM. The details of this method exceed the scope of this paper and can be further examined in [25]. One of the major drawbacks of a matrix converter is that 18 total switches are required, causing an increase in converter semiconductor cost.

V. I NDUCTION G ENERATORS

The use of induction generators (IG) is advantageous since they are relatively inexpensive, robust and they require low maintenance. The nature of IG is unlike that of PMSG, they need bi-directional power flow in the generator-side

462

converter since the induction generator requires external reactive power support from the grid. The use of back-to-back PWM converters, Fig. 8, along with the implementation of one or more fuzzy logic controllers is a consistent converter-control combination [26-28]. The advantages of fuzzy logic control are parameter insensitivity, fast convergence and acceptance of noisy and inaccurate signals. In [26], a PI type fuzzy logic controller takes in the DC voltage error and the change in DC voltage error. The controller outputs the d-axis reference current used in real power flow control. In a similar manner the q-axis current is kept zero to maintain unity power factor.

A control scheme using three fuzzy logic controllers has also been investigated in [27]. The first controller tracks the generator speed with the wind velocity to extract maximum power. The second controller programs the machine flux for light load efficiency improvement. More specifically the machine rotor flux can be reduced from the rated value to reduce the core loss and thereby improve the efficiency. The rotor flux may be reduced by continually decreasing the magnetizing current until the maximum power increase is obtained. The third controller gives robust speed control against wind gust and turbine oscillatory torque. Unlike the second controller, the third fuzzy logic controller is always active.

In other work a PI fuzzy controller is also used [28]; however, rotor slot harmonics (RSH) are used for speed estimation. The rotor slots interact with the magnetizing component of the air-gap magneto-motive force (MMF), generating harmonics that are dependant on the machine rotational speed [28]. Once the algorithm locates the frequency of the RSH through a look-up table, the rotational speed is found through a series of calculations. Along with the use of RSH, the control system also utilizes sensor-less control through a model reference adaptive system (MRAS) observer to estimate the rotational speed. More information on this system is located in [28], as the details will not be discussed here. A control option for the supply-side converter includes real and reactive power control. A reference frame orientated along the supply voltage rotating vector allows for real power control through d-axis current control and q-axis manipulation controls the reactive power [28].

An atypical WECS converter setup has been explored [29]. Instead of the usual back-to-back PWM converter scheme, the authors use a fixed-capacitor thyristor-controlled reactor static VAR compensator at the generator terminals to regulate its voltage. The mechanical input power is controlled using the blade pitch angle. The design techniques used for the control systems are based on the state space linearized model of the system. Two controllers, a state feedback controller and output feedback controller were designed. The output feedback control is preferred since all the output signals are available for measurement and an observer is not needed as in the state feedback control [29].

A comparison between the use of a wound rotor induction

machine and a caged rotor induction machine, both

of identical size, has been performed [30]. The comparison ensures validity with the use of identical converter types in each of the systems. It is shown, under the same wind conditions, that the wound rotor induction machine outputs 35kWh of energy over ten minutes, where as the caged induction machine only outputs 28.5kWh in ten minutes. The higher cost of the wound rotor induction machine, due to possible need of slip rings, is compensated by the reduction in the sizing of the power converters and the increase in energy output. The DFIG is superior to the caged induction machine, due to its ability to produce above rated power.

VI. S YNCHRONOUS G ENERATORS

Finally, the application of synchronous generators (SG) in wind power generation has also been researched. A brief description of one possible converter-control scheme is given for a small wind energy conversion system. The use of a diode rectifier along with a DC/DC boost stage and inverter as a power electronic interface for grid connection has been discussed [31]. The converter is similar to Fig. 3c, except a SG replaces the PMSG. In this scheme the DC-link voltage is controlled by using the amplitude of the three-phase inverter voltages and the phase displacement angle of the inverter. The linearized currents and DC-link voltage of the inverter can be obtained by means of state equations [31]. Controller performance improvements are achieved over the traditional power angle control. For low power systems, the existence of a winding circuit in the rotor may be a drawback as compared with PMSG. Although PMSG are commonly used for low power application, the more recent larger systems use SG. In large systems the energy from the SG are most commonly converted through back-to-back PWM voltage source inverters, similar to Fig. 8. The supply side PWM inverter allows for control of real and reactive power transferred to the grid. The generator side converter is used for electromagnetic torque regulation [32,33]. The controllers used in these systems are designed to achieve maximum power transfer to the grid. These generators have a high efficiency since the whole of the stator current is employed during electromagnetic torque production. Another advantage is the minimization of stator current through the direct control of generator power factor, In comparison to IG, the use of SG is advantageous since they are self excited machines and the pole pitch of the machine can be smaller. As a result both DFIG and SG are preferred for high power applications.

463

VII.S UMMARY OF W IND E NERGY C ONVERSION S YSTEMS

A summary of the different generator-converter topologies available for wind energy conversion is shown in Table 1. The cost of the overall system increases as the complexity of the power electronic converter increases. The intricacy of the controller design also affects cost; for example the use of MPPT techniques would cost more than a simple look-up table method. However higher order control and converter designs may increase efficiency of the overall system. The inclusion of a DC-boost stage helps reduce the control complexity of the grid inverter at a small increase in cost. Likewise, replacing the diode rectifier with a controlled rectifier allows for a wider range of control of both the generator and grid real and reactive power transfer. In order to maximize the benefits of the wind energy conversion system, a compromise between efficiency and cost must be obtained.

T ABLE 1: S UMMARY OF W IND E NERGY C ONVERSION S YSTEMS

Generator (Power Range)

Converter Options

Device Count

(Semiconductor Cost)

Control Schemes

Diode Bridge/SCR Inverter/Compensator

DC-Link Cap.

12 Controllable Switches

(Moderate)

Simple Firing Angle Control of One Converter SCR Rectifier/SCR Inverter

DC-Link Cap.

12 Controllable Switches

(Moderate)

Simple Firing Angle Control of Both

Converters

Diode Bridge/Hard-Switching Inverter

DC-Link Cap.

6 Controllable Switches

(Low)

Power mapping technique including stator

frequency derivative control

MPPT, wind prediction control Diode Bridge/DC Boost/Hard-Switching

Inverter

DC-Link Cap.

7 Controllable Switches

(Low)

Vector control of supply side inverter

DC Voltage control via chopper duty ratio Back-to-Back Hard-Switching Inverters

DC-Link Cap.

12 Controllable Switches

(Moderate)

MPPT, Vector control of both converters

PMSG (kW)

Back-to-Back Hard-Switching Inverters

(Reduced Switch)

2 DC-Link Caps.

8 Controllable Switches

(Low)

Generator controlled through MPPT

Inverter current controlled through PI

controllers

Diode Bridge/SCR Inverter

DC-Link Cap.

6 Controllable Switches

(Low)

Sliding Mode Control

SCR Rectifier/SCR Inverter

DC-Link Cap.

12 Controllable Switches

(Moderate)

Dual thyristor firing angle control

Back-to-Back Hard-Switching Inverters

DC-Link Cap.

12 Controllable Switches

(Moderate)

Vector control of rotor and supply side

Space Vector Modulation or PWM

MPPT, Space Vector Control

DFIG (kW-MW)

Matrix Converter 18 Controllable Switches

(High)

Vector control of rotor and supply side

Double Space Vector PWM switching

IG (kW-MW) Back-to-Back Hard-Switching Inverters

DC-Link Cap.

12 Controllable Switches

(Moderate)

Vector Control, Use Fuzzy Logic Controllers

Use rotor slot harmonics and model reference

adaptive system

Diode Bridge/DC Boost/Hard-Switching

Inverter

DC-Link Cap.

7 Controllable Switches

(Low)

Phase angle displacement control

Supply voltage control

SG

(kW-MW)

Back-to-Back Hard-Switching Inverters

DC-Link Cap.

12 Controllable Switches

(Moderate)

Supply real and reactive power control

Generator electromagnetic torque control

VIII.C ONCLUSION

Wind energy generation has become a highly researched area. A concise review of various WECS has been achieved through this paper. Converter topologies used in combination with PMSG, DFIG, IG and SG, along with different control schemes has been described in detail. All control methods described, attempt to obtain maximum energy transfer from the wind turbine to the grid. There is a continuing effort to make converter and control schemes more efficient and cost effective in hopes of an economically viable solution to

464

increasing environmental issues. Wind power generation has grown at an alarming rate in the past decade and will continue to do so as power electronic technology continues to advance.

R EFERENCES

[1]Danish Wind Industry Association, Information Available at:

https://www.sodocs.net/doc/4f9602369.html,/en/news050214.htm

[2]G.L. Johnson, Wind Energy Systems, Prentice Hall Inc., Englewood

Cliffs, N.J. (1985)

[3]Chen, Z., Spooner, E., “Current Source Thyristor Inverter and its

Active Compensation System,” IEE Proc. Generation, Transmission

and Distribution, Vol. 150, No. 4, pp. 447-454, July 2003.

[4]Tan, K., Islam, S., “Optimum Control Strategies in Energy

Conversion of PMSG Wind Turbine System without Mechanical

Sensors,” IEEE Trans. On Energy Conversion, Vol. 19, No. 2, pp.

392-399, June 2004.

[5]Chen, Z., Spooner, E., “Grid Power Quality with Variable Speed

Wind Turbines,” IEEE Trans. on Energy Conversion, Vol. 16, No.

2, pp. 148-154, June 2001.

[6]Chen, Z., Spooner, E., “Grid Interface Options for Variable-Speed

Permanent-Magnet Generators,” IEE Proc. Electric Power

Applications, Vol. 145, No. 4, July 1998.

[7]Chen, Z., Spooner, E., “Wind Turbine Power Converters: A

Comparative Study,” 7th International Conference on Power

Electronics and Variable Speed Drives, No. 456, pp. 471-476, Sept.

1998.

[8]Song, S.H., Kang, S., Hahm, N., “Implementation and Control of

Grid Connected AC-DC-AC Power Converter for Variable Speed

Wind Energy Conversion System,” 18th Annual IEEE Applied Power

Electronics Conference and Exposition, Vol. 1, pp. 154-158, Feb.

2003.

[9]Higuchi, Y., Yamamura, N., Ishida, M., Hori, T., “An Improvement

of Performance for Small-Scaled Wind Power Generating System

with Permanent Magnet Type Synchronous Generator,” 26th Annual

Conference of the IEEE Industrial Electronics Society, Vol. 2, pp.

1037-1043, Oct. 2000.

[10]Schiemenz, I., Stiebler, M., “Control of a Permanent Magnet

Synchronous Generator Used in a Variable Speed Wind Energy

System,” IEEE International Electric Machines and Drives

Conference, pp. 872-877, 2001.

[11]Raju, A.B., Chatterjee, K., Fernandes, B.G., “A Simple Maximum

Power Point Tracker for Grid Connected Variable Speed Wind

Energy Conversion System with Reduced Switch Count Power

Converters,” IEEE 34th Annual Power Electronics Specialist

Conference, Vol. 2, pp. 748-753, June 2003.

[12]Koyanagi, A., Nakamura, H., Kobayashi, M., Suzuki, Y., Shimada,

R., “Study on Maximum Power Point Tracking of Wind Turbine

Generator Using A Flywheel,” Proc. of the Power Conversion

Conference, Vol. 1, pp. 322-327, April 2002.

[13]Huang H., Chang, L., “A New DC Link Voltage Boost Scheme of

IGBT Inverters for Wind Energy Extraction,” Canadian Conference

on Electrical and Computer Engineering, Vol. 1, pp. 540-544,

March 2000.

[14]Huang, H., Chang, L., “Energy-Flow Direction Control of Grid-

Connected IGBT Inverters for Wind Energy Extraction,” Canadian

Conference on Electrical and Computer Engineering, Vol. 1, pp.

535-539, March 2000.

[15]De Battista, H., Puleston, P.F., Mantz, R.J., Christiansen, C.F.,

“Sliding Mode Control of Wind Energy Systems with DOIG-Power

Efficiency and Torsional Dynamics Optimization,” IEEE Trans. On

Power Systems, Vol. 15, No. 2, pp. 728-734, May 2000.

[16]Cadirci, I., Ermis, M., “Double-Output Induction Generator

Operating at Sub-synchronous and Super-Synchronous Speeds:

Steady-State Optimization and Wind-Energy Recovery,” IEE Proc.

B Electric Power Applications, Vol. 139, No. 5, pp. 429-442, Sept.

1992. [17]Uctug, M.Y., Eskandarzadeh, I., Ince, H., “Modeling and Output

Power Optimization of a Wind Turbine Driven Double Output

Induction Generator,” IEE Proc. Electric Power Applications, Vol.

141, No. 2, pp. 33-38, March 1994.

[18]Pena, R., Clare, J.C., Asher, G.M., “Doubly Fed Induction Generator

Using Back-to-Back PWM Converters and its Application to

Variable-Speed Wind-Energy Generation,” IEE Proc. Electric

Power Applications, Vol. 143, No. 3, pp. 231-241, May 1996. [19]Rabelo, B., Hofmann, W., “Optimal Active and Reactive Power

Control with the Doubly-Fed Induction Generator in the MW-Class

Wind-Turbines,” 4th IEEE International Conference on Power

Electronics and Drive Systems, Vol. 1, pp. 53-58, Oct. 2001.

[20]Abbey, C., Joos, G., “A Doubly-Fed Induction Machine and Energy

Storage System for Wind Power Generation,” Canadian Conference

on Electrical and Computer Engineering, Vol. 2, pp. 1059-1062,

May 2004.

[21]Datta, R., Ranganathan, V.T., “A Method of Tracking the Peak

Power Points for a Variable Speed Wind Energy Conversion

System,” IEEE Transactions on Energy Conversion, Vol. 18, No. 1,

pp. 163-168, March 2003.

[22]Datta, R., Ranganathan, V.T., “Direct Power Control of Grid-

Connected Wound Rotor Induction Machine Without Rotor Position

Sensors,” IEEE Trans. on Power Electronics, Vol. 16, No. 3, pp.

390-399, May 2001.

[23]Bhowmik, S., Spee, R., “Wind Speed Estimation Based Variable

Speed Wind Power Generation,” Proc. of the 24th Annual

Conference of the IEEE Industrial Electronics Society, Vol. 2, pp.

596-601, Sept. 1998.

[24]Zhang, L., Watthanasarn, C., Shepherd, W., “Application of a

Matrix Converter for the Power Control of a Variable-Speed Wind-

Turbine Driving a Doubly-Fed Induction Generator,” 23rd

International Conference on Industrial Electronics, Control and

Instrumentation, Vol. 2, pp. 906-911, Nov. 1997.

[25]Keyuan, H., Yikang, H., “Investigation of a Matrix Converter-

Excited Brushless Doubly-Fed Machine Wind-Power Generation

System,” The 5th International Conference on Power Electronics

and Drive Systems, Vol. 1, pp. 743-748, Nov. 2003.

[26]Pena, R.S., Cardenas, R.J., Clare, J.C., Asher, G.M., “Control

Strategies for Voltage Control of a Boost Type PWM Converter,”

IEEE 32nd Annual Power Electronics Specialists Conference, Vol. 2,

pp. 730-735, June 2001.

[27]Simoes, M.G., Bose, B.K., Spiegel, R.J., “Fuzzy Logic Based

Intelligent Control of a Variable Speed Cage Machine Wind

Generation System,” IEEE Trans. On Power Electronics, Vol. 12,

No. 1, pp. 87-95, Jan. 1997.

[28]Cardenas, R., Pena, R., “Sensorless Vector Control of Induction

Machines for Variable-Speed Wind Energy Applications,” IEEE

Trans. On Energy Conversion, Vol. 19, No. 1, pp. 196-205, March

2004.

[29]Abdin, E.S., Xu, W., “Control Design and Dynamic Performance

Analysis of a Wind Turbine-Induction Generator Unit,” IEEE Trans.

On Energy Conversion, Vol. 15, No. 1, pp. 91-96, March 2000. [30]Datta, R., Ranganathan, V.T., “Variable-Speed Wind Power

Generation Using Doubly Fed Wound Rotor Induction Machine – A

Comparison with Alternative Scheme,” IEEE Trans. On Energy

Conversion, Vol. 17, No. 3, pp. 414-421, Sept. 2002.

[31]Svensson, J., “Simulation of Power Angle Controlled Voltage

Source Converter Using A Linear Quadratic Method in a Wind

Energy Application,” IEEE Workshop on Computers in Power

Electronics, pp. 157-163, Aug. 1996.

[32]Marques, J., Pinheiro, H., Grundling, H., Pinheiro, J., Hey, H., “A

Survey on Variable-Speed Wind Turbine System,” Brazilian

Conference of Electronics of Power, Vol. 1, pp. 732-738, 2003. [33]Nicolas, C., Lafoz, M., Iglesias, J., “Guidelines for the Design and

Control of Electrical Generator Systems for New Grid Connected

Wind Turbine Generators,” IEEE 28th Annual Conference of the

Industrial Electronics Society, Vol. 4, pp. 3317-3325, Nov. 2002.

465

相关主题