General Specifications
Outline
Material
Casing : Aluminum
Impeller : Polybuthylene terephthalate (Glass Fiber-Containing)Bearing : Ball Bearings
Lead Wire : Faston #110 or Equivalent
Expected Life
Failure Rate: 10%
25°C 100,000 Hours
Motor Structure: Shaded Pole Induction Motor
Motor Protection: Impedance Protection Insulation Resistance:
10M ? or over with a DC500V Megger
Dielectric Withstand Voltage: AC 700V 1s Allowable Ambient T emperature Range:
-10°C ~ +65°C (Operating) -40°C ~ +70°C (Storage)
(non-condensing environment)
35
70
106
141INLET SIDE / OUTLET SIDE
ROTATION
Rotation: Counterclockwise Airflow Outlet: Air Out Over Struts *1: Maximum Values in Free Air
** Contact NMB for Availability *2: Average Values in Free Air
*3: Minimum Values in Free Air
分销商库存信息:
NMB
4715HS-23T-B50-AM04715HS-12T-B50-AM04715HS-22T-B50-BM0 4715HS-10T-B50-BM04715HS-20T-B50-BM04715HS-24T-B50-AM0