概要:正在起草中IEC 60598-1 第8 版首次以LED 为关注焦点对标准进行修订,其中蓝光危害的要求引用了IEC/TR 62778 的要求。本文以修订中的IEC 60598-1 第8 版CDV 文件考虑的灯具蓝光危害的标记和结构要求为切入点,介绍了IEC 62471 和IEC/TR 62778 标准的相关要求,以及灯具产品进行蓝光评价的一般方法。

关键词:风险分类;整体式LED 或L ED 模块;LED 蓝光危害

Abstract: The 8TH edition of IEC 60598-1 being drafted now will be revised version focused on LED, and the requirement for blue light hazards refers to IEC 62778. considering the requirements of mark and structure of CDV of IEC 60598-1 8TH edition as a start point, this article introduces the related requirements of IEC 62471 and IEC/TR 62778 and the general requirements for evaluate the blue hazards of luminaires.

Key words: risk group integrated LED

LED module LED blue light harzards

IEC 60598-1 第8 版首次以LED 为关注焦点对标准进行修订,标准的修订以LED 灯具的光学、电气和结构特点为考虑要素,补充了对LED 灯具的蓝光危害的标记和结构要求,针对较多LED 灯具中光源工作电压为特低电压的特点,规定了LED 灯具的绝缘要求。同时由于光源不可替换、灯具电路中可能使用过电压保护装置的情况,对灯具的结构和电气强度试验的规定进行了修订。

目前IEC 标准体系中涉及照明产品光生物危害的基础标准是IEC 62471 系列标准,由于LED 照明产品涉及LED 芯片、LED 封装、LED 模组和LED 灯具等产品链,如果在各个产品阶段都对LED 照明产品进行视网膜蓝光危害评价将带来很多重复性的工作,就此,IEC/TC34 出版了技术报告IEC/TR 62778,其目的是应用IEC 62471 对LED 光源和灯具的蓝光危害进行评价。正在制定过程中的LED 光源类产品和LED 灯具产品安全的IEC 标准中,都引用了IEC 62778 的评价方法,对LED 产品的标记、结构提出安全要求。

本文以修订中的IEC 60598-1 第8 版CDV 文件考虑的灯具蓝光危害的标记和结构要求为切入点,介绍了IEC 61471 和IEC/TR 62778 标准的

相关要求,以及灯具产品进行蓝光危害的一般方法。

一、IEC 60598-1 第8 版CDV 文件相关要求介绍

在IEC 60598-1 第8 版中规定对灯具产品的视网膜蓝光危害的限制,通过规定灯具产品的标记和结构要求,使灯具产生的蓝光危害不会达到危害安全的程度。

(一)标记(3.2.23)

在标准的第 3 章标记中的规定包括:

1.对可移式和手提LED 灯具

根据IEC/TR62778 分类为具有RG1/RG2(E thr)极限条件的可移式和手提式灯具,要有建议“不要朝光源盯着看”的符号(见图1)。这个标记应标在灯具上,而且在灯具安装完成后能看得见,标记的高度应不低于5mm。

图 1 “不要朝光

源盯着看”的符号

2. 维护期间能直接看见光源的灯具

灯具含有根据IEC/TR 62778 具有RG1/2(Ethr)极限条件LED 光源,而且在灯具维护期间可以直接看到的,应标记“不要朝光源盯着看”的符号(见图1)。这个标记应标在灯具维护时可以看得见的灯具外表面、或更换光源时移动的罩子的反面位置上,标记的高度不低于5mm。

3.对固定式灯具

根据IEC/TR 62778 分类为具有RG1/RG2(E thr)极限条件的固定式灯具,当Xm 是出现RG1/RG2(E thr)极限条件的距离,随灯具一起提供的制造商的说明书应提供“应将灯具放在预期不会在近于X m 的距离持续朝灯具盯着看的位置。”文字。这个要求只适用于当达到E thr 时离灯具的距离

比200mm 远的情况。

根据IEC TR62778 的 6.1,Xm 是光源与观察者眼睛之间的距离,它来自于灯具照明分布测量的计算。

(二)结构(4.24.2)

针对IEC62471 给出的蓝光危害组别,在IEC 60598-1 第4 章中规定了各种类别光源在灯具中使用规定。

1.不使用超过RG2 的LED 光源

带有整体式LED或LED模块的灯具应根据IEC/TR 62778“应用IEC 62471评估光源和灯具的蓝光危害”进行评估。

希望不使用蓝光危害的大于RG2 的LED 光源。对这种类型光源的要使用更多繁重管理要求。

同时标准提示,因为这种产品在市场还没有使用RG3 的LED 光源的灯具,所以还没有对此提出,如有需要将来会开发。

2.对分类为RG0 或RG1 的情况

使用按IEC/TR 62778 具有RG0 或RG1(基于200mm,0.011 弧度测量)光源的灯具,或在相同条件下按使用完整装配被评估为RG0 或RG1 的灯具,没有附加的要求。

3.具有RG1/RG2(E thr)边界条件的情况对按照IEC/TR 62778 具有RG1/RG2(E thr)边界条件的灯具,应满足下述要求:

a)对固定式灯具,要按IEC/TR 62778 进行附加的评估,目的是找到灯具与RG2 和RG1

边界的距离Xm,并应按本标准要求进行标记。

b)对于在200mm(0.011 弧度测量)超过RG1 可移式和手提灯具,要求按照IEC60598-1

的规定进行标

记。标准同时

提示:

-通常风险组别的分类应可以从LED 光源制造商处得到;

-对于一些设计成使用整体式LED 光源的灯具,需要对灯具整体进行试验;

-在建筑物中经过周到考虑的延展的LED阵列,或使用更多的光学器件不会增加基本LED

光源的危险组类别;

-制造商声称的灯具光度数据可以用于”a”项所要求的评估。

4. 对儿童用可移式灯具和电源插座安装的夜灯

对IEC60598-2-10覆盖的儿童用可移式灯具,以及IEC60598-2-12覆盖的电源插座安装的夜灯,在200mm(0.011 弧度测量)不应超过RG1。

二、IEC/TR 62778 的内容概要

在IEC 60598-1 第8 版CDV 文件中标记和结构要求中增加的蓝光危害的相关要求中,在引出一些新的概念,如蓝光危害、危险组别(RG),E thr 等的同时,也规定了灯具蓝光危害的评价要按照IEC TR 62778 的规定。

(一)定义

1.蓝光危害blue light hazard,BLH

由波长主要介于400nm 和500nm 的辐射照射后引起的光化学作用,导致视网膜损伤的潜能。此伤害机理主要是超过10s 的热损伤生理反应。

2.风险组别risk group,RG

λ λ λ 按照 IEC 62471 的定义, 当产品在相关评价位置产生上升到表 1 的某一 t max 值时的危险 分类。

表 1 暴露时间与危险组别的关系 危险组危险组相应的 t max 的RG0 免除 >10000 RG1 低危险 100~10000 RG2 中等危0.25~100 RG3

高危险 <0.25 3. 照度阈 threshold illuminance ,E

thr 照度值的阈,不考虑光源的 L B

值,低于这个阈的光源,不会引起 t max

<100s 。 注 1:可以通过 t max =100s 时 E B 值进行计算,其中 E B =1W/m 2

, 并将其除以光源光谱相应的 K B,v 值。 注 2:照度阈用 lm/m 2 = lx 表达。 4.

蓝光加权辐照度 blue light weighted irradiance ,E B 用 IEC 62471 定义的蓝光光谱加权函数进行光谱加权的辐照度。 5. 光辐射的蓝光危害效能 blue light hazard efficacy of luminous radiation ,K

B,v

蓝光危害量与相应光度量的商。 其中:K m =

683 lm/W 。

注 1:光辐射的蓝光危害效能用 W/lm 表达。

φ (λ) L (λ) E (λ) 注 2:下述公式中的 可以用 或 代替。

K B,v =

?φλ (λ) ? B (λ) ? d λ K m

?φλ (λ) ?V (λ) ? d λ 注 3: K B,v = L B /L = E B /E 。

6. 蓝光加权亮度 blue light weighted radiance ,L B

以IEC 62471规定的蓝光光谱函数加权的亮度。

7.集光率 etendue

在一个光学系统中收集光束的几何特性,其构成包括这些光线所经过平面的所有位置和它们传导的所有方向。

8. 整体式部件integral component

构成灯具的一个不可替换部分的元件,它不能与灯具分开进行试验。

(二)从IEC 62471 到IEC/TR 62778

IEC 62471 是一个综合性的平行标准,描述了所有潜在的健康危害,从光谱的紫外、可见光和红外波段。IEC/TR 62778是一个仅针对IEC 62471:2006标准的第4.3.3条和第4.3.4 条所描述的视网膜蓝光危害的技术报告。

1. IEC 62471 规定使用的评价参数

-辐亮度

视网膜蓝光危害主要由可见光中的蓝光波段引起的,对视网膜有潜在的危害作用。它在视网膜上的作用不仅在于到达眼睛的光的数量,而且关乎发光光源的尺寸。相同数量的光,大的光源在视网膜上的成像区域较大,所以在视网膜上产生的辐亮度低于小光源。IEC 62471:2006 第 4.3.3 条将此描述为光源辐亮度的最大允许曝光时间t max。

辐亮度L(单位: W/(m2.s r) )是一个描述辐射强度的量,是射入某方向的辐射功率除以从相

同方向看到的光源的表面积。在成像系统里,例如眼睛,成像平面(对眼睛来说是视网膜)上的局部照度与光源的亮度成比例。

-辐照度

当光源太小以至于不会强烈成像,或者它是如此的小以至于它远不能在视网膜上的相同区域固定而产生危害,那辐亮度不是一个适当的值。在这种情况下,要应用IEC 62471:2006 第 4.3.4 条,这时在瞳孔上的辐照度作为一个与在视网膜上的辐亮度成比例的值。

“大”光源使用 4.3.3,或“小”光源的使用4.3.4,取决于光源的尺寸以及观察距离。光源的包络角是一个识别量。当产生危险的时间大于10s 时,IEC 62471 规定光源大或小的包络角限值是0.011rad。当处于大或小的边缘时,可以用 4.3.3 或 4.3.4 二者选一的方法计算t max,将得到5%以内的相同的结果。5%的偏离是由于辐射量转换到t max 的转换因数的取整。

2. IEC 62471 规定的评价蓝光危害的标准条件

IEC 62471 陈述了产品的危害类别。因为根据IEC 62471:2006 第4.3 条计算的t max 值由产品本身和其被观察的距离确定,不能将它们本身用于确定产品特有的危害类别,因此IEC 62471 第 6 章陈述了确定危害类别的评价光生物安全的标准条件,即对于要用于普通照明

(GLS)的灯,应在不小于200mm 的产生500 lx 照度的距离报告危害值。对其他光源,包括脉冲灯,应在200mm 报告危害值。在评价距离上确定t max,而且当其不到100s 时,产品分类为危险组

别2(RG2),并要求有警告标贴。

重要的是要仔细评定这两种不同评估条件可以提供的信息,它们与实际应用中的危害评价相关。虽然500 lx 是照明应用中大量使用的一个典型照度值,但也不能否认存在一些应用,即在观察者位置的距离照度高于500 lx。那500 lx 的危害等级告诉我们什么呢?另外,对用于人们不会处于工作光源近处的高功率光源,在200mm 评价又将导致夸大的危害评估,例如道路照明和体育馆照明,而近距离测量这样的光源的又一个问题是对标准光度测量设备的损害。

3. IEC/TR 62778 的考虑

虽然IEC 62471 引导GLS 情景下的500lx 测量,而实际上照明水平通常会高于或低于500lx,500lx并不必然代表适宜的光辐射情景。因此IEC/TR 62778推荐在200mm、0.011rad 测量来确定适宜的RG1/2 的边界条件。

IEC/TR 62778 将调查下述两个事项(a)基于光源元件将其转换成一个较高水准照明产品的光生物安全的信息;(b)推荐测量距离和危害组分类。经过光谱计算和光度考虑,这些推荐建立在分析与蓝光危害相关量的基础上。

三、IEC/TR 62778 评价方法的基础

IEC/TR 62778 给出了LED 照明产品应用存在的几个水平,提出初级光源的危害分类可以传递到其之后水平产品。

(一)LED 封装、LED 模块、灯和灯具是LED 照明产品的几个应用水平

在照明商业中,基于组合的水平存在产品层次。不同组合水平的产品由不同的制造商制造。为了尽可能避免每次在下个水平的重复评价,有必要将光生物安全的信息通过链往下传。由于每下个水平一般都伴随着产品变化的急剧增加,所以这非常需要。

在LED 之前,所有照明技术存在两个水平:灯和灯具。灯是初级光源,利用开放的机械和电气接口的行业标准,灯置入灯具内。灯具设计时是考虑某一类型的灯泡,但由于灯具中的接口标准是开放的,最终用户具有用另一种类型的灯泡替代这个灯的可能性。

对LED 技术,情况更多样化了。存在产品水

平链,工业界对它们进行下述的编号:水平

0:LED 芯片。

水平1:LED 封装,允许焊接和清洁的室内环境以外的处理。对白光LED 封装,内部含有将芯片的蓝色光转换成其他波长产生白光的荧光粉材料。

水平2:基本LED 模块,包括在印刷线路板上的一个多个LED 封装。

水平3:有扩展功能的LED 模块,通常包括一个带有允许机械安装,电气连接或光度作用的附加特性的水平2的板。呈现的附加特性取决于产品类型,而且可能包括一些或全部LED 模块工作所需的电子控制装置。

水平4:灯具,应用中使用的LED 产品。

通常,水平 4 产品中的低水平LED 模块和LED 封装未设计成最终用户容易替换的。不同水平的接口很少以开放的工业标准为基础。

LED 替换灯是一个特例。它们是公开销售的LED 产品,为开放的之前存在的灯技术的标准接口设计。他们将作为灯具原设计的灯的替代,由最终使用者装入灯具。

(二)蓝光危害信息传递链

IEC TR62778 提出,初级光源的蓝光危害信息可以往下传递,蓝光危害信息传递到下一水平产品的基础是:亮度守恒定律和IEC/TR 62778 第5 章的说明。

1.亮度守恒定律介绍

如果初级光源的亮度(或辐亮度)已知,也就提供了含有这些光源所有照明产品的上限值。它包括光通量守恒和集光率守恒两个基础守恒定律。增加辐亮度就意味着要提高光通量或降低集光率,而这都是基础守恒定律禁止的。对于一个被动的光度系统,光通量不增加是容易解释的,但不可能降低集光率就不那么容易理解了。但不管怎样,降低集光率是集光率守恒定律禁止的,如再进行深入调查,其根本原因类似于“热力学第二定律”。

注:热力学第二定律的定义是不可能把热从低温物体传到高温物体而不产生其他影响;不可能从单一热源取热使之完全转换为有用的功而不产生其他影响;不可逆热力过程中熵的微增量总是大于

零。

2.亮度守恒定律的应用

使用亮度守恒定律时,信息流的最佳始点是辐亮度测量。辐亮度值传递链从初级光源到灯具,如果光源在灯具内的工作条件与进行元件测量时的条件相似,不要求附加的测量。

当要对灯具进行减少的辐亮度的光度测量(如一个漫反射罩和(或)在较低电流下工作)时,可以用附加的测量来验证减小的亮度值。如果没有进行该测量,初始亮度值保持了始终安全的最差估计。

如果在初始光源的亮度测量得到的L B 值在RG0(0 W/(m2sr)到100 W/(m2sr))或RG1(100 W/(m2sr)到10000W/(m2sr))区域。它不可能到RG2,不考虑光度系统的类型(包括产生方向性光输出的光束修改光度系统)和应用时的观察距离,该信息可以传递到基于该初级光源的所有产品。

如果在初始光源的亮度测量得到的L B 值在RG2(10000 W/(m2sr)到4000000 W/

(m2sr)),根据应用的情况,其最终产品可能在RG2 内。为了找出这种情况,要使用IE C/TR 62778 的判定。在应用中,当在观察位置的照度高于由RG1 上限值的E B 和K B,v 值计算的阈值E thr,才可能出现RG2 的情况。

3. 测量结果

初级光源辐亮度测量可能提供 3 个可能的结果:

a) RG0 无限制:在所有灯具中的所有距

离,初级光源最高产生了RG0; b) RG1

无限制:在所有灯具中的所有距离,初级

光源最高产生了RG1;

c) RG2 的E thr:在某距离时初级光源产生了RG2,此处含有初级光源的灯具产生的照度高于E thr;在某距离时初级光源产生了RG1,在此处含有初级光源的灯具产生的照度低于E thr。注:蓝光危害达到RG3 是不太可能的,所以IEC/TR 62778 不涉及这部分内容。

如果产生了第 3 种结果,危险组别取决于使用

条件。在人很可能注视灯具的最小距离, 照度是否高于或低于 E thr

值。这个距离取决于灯具的光度并可能因此不来自于灯具的初级光 源。如果来自灯具光学器件的光分布的峰值角度已知,大小和方向的值是可以计算的。对于 很多光束造型光度系统,光分布是已知的,因为光分布是专业照明设计需要的。

为了找到灯具最大光强所在的方向,应用分布光度计测量。

E thr = I ? cos α d 2

I 是评价 E thr 位置所在方向的光强

d 是光源到该位置的距离 α是光源的方向和评价 E thr

所在平面法线的夹角(见图 2)

图2 照度 E 、距离d 和光强I 的

关系

四、IEC 62778 规定的评价流程和测量方法

1. 辐亮度测量条件

在进行实际操作时,必须确定

什么是初级光源的辐亮度标准测量条件。这些条件中应至少规定

平均辐亮度的测量距离和视场。与IEC 62471给出的实际测量条件一致,200mm距离和0.011rad视角是一个好的开始点。如果视场孔未充满光源的发光面积,那这些条件给出了一个正确的辐亮度值。由于这个等于2.2mm直径,这是很多光源的情况。

要注意的是,只有当初级光源的试验条件等同于灯具的试验条件,结果才能转换。因为初级光源制造商一般不了解灯具的试验条件,至少应报告最差试验条件的结果(例如,对LED封装至少在最大额定电流),可能的附加报告,其他规定试验条件(例如,LED封装低于最大额定电流的规定电流水平)的结果。

当0.011rad视场孔在仅200mm距离溢出光源面积时,测量没有给出正确的亮度值。在这种情况下,有两个办法:

a) 可以减小测量视场孔,使之未充满光源。在这种条件下确定辐亮度值L B,这样就可确定光源的危害组别。

b) 完成辐照度测量。这可以给出数据计算E thr。因为没有进行辐亮度测量,要假定最差的情况,而且只能产生一种结果:RG2的E thr值。

有些光源可产生大量的光,从技术上说在 200mm 距离测量是不可能的,因为这会使测量设备过热或饱和。这种情况下,测量距离可以增加到可能测量的最小值。此外,还必须估计视场孔充满光源与否。如果视场孔未充满光源,测量产生的正确的辐亮度值。如果视场孔充满了光源,再次选择降低视场孔或进行辐亮度测量,并假设最差的情况:RG2 的E thr 值。图3 是概述所要求测量的流程图,信息需要下溯到初级光源,以对灯具应用进行正确的危害组别分类。

1) 从<10000 cd/m2 条件得出的RG0 结论仅对白光光源有效。

图 3 从初级光源(兰色)到使用该光源的灯具(琥珀色)的信息流流程描述图

五、按蓝光低危险发射限估计的不同色温光源RG1/RG2 亮度或照度边界

1. K B,v 与光谱的相关色温(CCT)有牢固关系

IEC TR62778 报告了确定不同光源光谱的K B,v 时的一个有趣的观察数据,见图4。对所有白光光源,不论它是白炽灯、高强度放电灯或LED 技术,在K B,v 与光谱的相关色温(CCT)有牢固的关系。甚至在白天也有相同的趋势,虽然严格地说这不是只关注人工光源的IEC 62471 的主题。

GBT 22907-2008 灯具的光度测试和分布光度学

GB/T22907-2008 灯具的光度测试和分布光度学 1 介绍 1.1 范围 本标准包含了大部分类型灯具光度测试的通用要求。 本标准规定了光度测试的标准条件,并推荐了测试程序,使所确定的灯具光度特性及其陈述报告有足够的准确度和复现性,这些规定为统一国家标准提供基础,并为光度实验室的试验和灯具性能数据的表达提供指导。对于实际测试条件不同于标准测试条件的灯具,标准给出了修正系数的测量要求。 对手实验室人员和工程师来说,光度测量方法的详细描述是最重要的,对于数据使用者来说这同样重要。对数据的适当解释通常依赖于对所涉及测量过程的充分了解,同时,本标准也提供给使用者理解光度测量程序和表达的数据。 为极其专业的设施设计的特殊灯具类型,对测量和数据表达要求相关的特殊推荐有需求时,此类通用标准不能覆盖其特性,应以许多补充标准来满足这种需要,这些补充标准将本标准适当章节内引用,并在必要时定义特殊要求和测量条件。 对于没有特定标准覆盖的灯具,可以使用最适合的标准和本通用标准的要求来指导实际的测量程序。 1.2光度特性 光度特性可以被分为测量到的特性,即那些用实验设备直接测量到的,以及推导出的特性,即由测量数据计算得到的。推导的特性更接近相关的照明应用。本标准主要涉及被测量的光度特性。 2术语 仅包含了直接相关的定义。本标准中列出的一些术语可能会在其他标准中以不同的名称(在方括号内给出)出现。 其他的相关定义见CIE/IEC 17. 4-1987 [1]。 2.1 灯具的术语 2.1.1 灯具 luminaire

凡是能分配、透出或转变一个或多个光源发出光线一种器具,并包括支承、固定和保护光源必需的所有部件(但不包括光源本身),以及必需的电路辅助装置和将它们与电源连接的装置。 2.1.2 (灯具)设计姿态[通常应用中也可以倾斜]design attitude (of luminaire) [also.tilt normal in application] 灯具设计的工作姿态(参考制造商的使用说明或常用方式来确定)。 2.1.3 (灯具)测试姿态[测量中也可以倾斜]measurement attitude (of lummaire) [also tilt normal in measurement] 灯具被测试时的姿态。 注:如果没有特别指出,采取与设计一致的姿态。 2.1.4 (光源)光中心 light center (of a source) 用作光度测试和计算的原点。

面板灯 600x600 36W 6000K暗房测试报告

室 内灯具光度数据 C角度范围: 0度 - 360度C角度间隔: 5.0度γ角度范围: 0度 - 90度γ角度间隔: 0.5度 测试速度: 快速测试系统: 远方(EVERFINE)GO-2000A_V1系统 V2.0.281环境温度:25.3℃环境湿度:65.0% 测试距离:5.581米 [K=1.0000] 测试人员:HE 测试日期:2014-08-27备注:6000K

灯具环带光通量 环带光通量: γ 5 0- 5 10 5- 10 15 10- 15 20 15- 20 25 20- 25 30 25- 30 35 30- 35 40 35- 40 45 40- 45 50 45- 50 55 50- 55 60 55- 60 65 60- 65 70 65- 70 75 70- 75 80 75- 80 85 80- 85 90 85- 90 95 90- 95 100 95-100 105100-105 110105-110 115110-115 120115-120 125120-125 130125-130 135130-135 140135-140 145140-145 150145-150 155150-155 160155-160 165160-165 170165-170 175170-175 180175-180 C0C45C90C135C180C225C270C315γ(°)Φ环Φ总%lum,lamp 单位:° 光强:cd 单位:lm 1404139113881391140413921389139233.4733.470.89,0.891384136513651365138413661366136698.74132.2 3.52,3.5213501332134313341350133413441334160.5292.77.78,7.7813051293128012971303129812811296216.5509.213.5,13.512481226121812311244123012181228263.8773.020.6,20.611781151115511551174115411561153301.8107528.6,28.610981074106510761094107510641076329.1140437.3,37.31009991.2973.8992.71005990.9971.9992.8344.1174846.5,46.5912.2889.1882.9890.8908.7888.2880.1889.6347.5209655.7,55.7809.2787.6778.1789.5806.3786.1772.9786.7339.5243564.8,64.8700.6686.7673.2688.8698.2684.5665.7684.3319.8275573.3,73.3587.9573.4568.3574.9585.1568.8558.5568.6289.9304581,81471.6462.4459.1463.1471.9455.2444.7455.1250.9329687.7,87.7352.7351.6349.8352.1353.5341.8330.9341.5203.9350093.1,93.1235.3241.0240.6242.0236.5228.3217.2227.2151.1365197.1,97.1126.5118.50119.6127.4106.50105.186.38373799.4,99.438.9900040.7700021.163758100,1000.9198000 2.727000 1.5753760100,100 C 角度范围: 0度 - 360度C 角度间隔: 5.0度γ角度范围: 0度 - 90度γ角度间隔: 0.5度 测试速度: 快速测试系统: 远方(EVERFINE)GO-2000A_V1系统 V2.0.281环境温度:25.3℃环境湿度:65.0% 测试距离:5.581米 [K=1.0000]测试人员:HE 测试日期:2014-08-27备注:6000K

积分球灯具测试报告解读

灯具测试报告解读 培训目的:能看懂灯具测试报告。 一、使用积分球测试灯具报告 色度参数 色品坐标X、Y、U、V:CIE1931 根据色品坐标计算出相关色温。 相关色温:用绝对温度“K”表示,当光源所发出的光的颜色与黑体在某一温度下辐射的颜色相同时,黑体的温度就称为该光源(灯具)的色温. 色温在2500-3300K的光源,颜色偏红,给人一种温暖的感觉。色温超过时,颜色偏兰,给人 一种清冷的感觉。

色度图中,色品坐标以X、Y表示,在CIE1976色度图中则以U、V表示,

暖白:2500-4000K 中性白:4000-5500K 正白光:5500-7000K 冷白光:7000以上 注:色温只对白光有意义,对于单色光,就要看它的主波长了。 主波长:用某一光谱色,按一定比例与一个确定的标准照明体相混合而匹配出的样 长就是样品色,该光谱色的波长就是样品色的主波长。 色比:光源的红、绿、蓝的三色比例。 峰值波长:光谱发光强度或辐射功率最大处所对应的波长。通常你所看到的一束光,它并非是单一波长的光,它是由很多波长的光组合而成的。其中,某一波长的 光的能量相对其它波长的光能量都大,则这一波长就是该束光的峰值波长。 半宽度:对于一个LED器件,其所发的光会在峰值λP处有所展开,其波长半宽度通常为10—30nm。对于单色光,半宽度越小,说明LED器件的材料越纯,性能越 均匀,晶体的完整性也越好。 色纯度:单色光是色纯度最高的颜色,当单色光掺入白光的成分越多时,色纯度就越低。显色指数:光源对物体真实颜色的呈现程度称为光源的显色性。显色指数用Ra表示,Ra值越大,光源的显色性越好。显色指数中R1至R8的平均值就是Ra值。R9至R15的含义:R9浓红色;R10浓黄色;R11浓绿色;R12浓蓝色;R13 亮的浅黄-粉红色;R14中等程度的橄榄绿色;R15东方女性肤色。 光度参数 光通量:光是电磁波辐射到人的眼睛,经过视觉神经转换为光线。光源发射并被人的眼睛接收的能量之和即为光通量。单位:流明(Lm)

积分球灯具测试报告解读

色度图中,色品坐标以X、Y表示,在CIE1976色度图中则以U、V表示, 灯具测试报告解读 培训目的:能看懂灯具测试报告。 一、使用积分球测试灯具报告 色度参数 色品坐标X、Y、U、V:CIE1931 根据色品坐标计算出相关色温。 相关色温:用绝对温度“K”表示,当光源所发出的光的颜色与黑体在某一温度下辐射的颜色相同时,黑体的温度就称为该光源(灯具)的色温. 色温在2500-3300K的光源,颜色偏红,给人一种温暖的感觉。色温超过时,颜色偏兰, 一种清冷的感觉。

暖白:2500-4000K 中性白:4000-5500K 正白光:5500-7000K 冷白光:7000以上 注:色温只对白光有意义,对于单色光,就要看它的主波长了。 主波长:用某一光谱色,按一定比例与一个确定的标准照明体相混合而匹配出的样 长就是样品色,该光谱色的波长就是样品色的主波长。 色比:光源的红、绿、蓝的三色比例。 峰值波长:光谱发光强度或辐射功率最大处所对应的波长。通常你所看到的一束光,它 并非是单一波长的光,它是由很多波长的光组合而成的。其中,某一波长的 光的能量相对其它波长的光能量都大,则这一波长就是该束光的峰值波长。 半宽度:对于一个LED器件,其所发的光会在峰值λP处有所展开,其波长半宽度通常

为10—30nm。对于单色光,半宽度越小,说明LED器件的材料越纯,性能越 均匀,晶体的完整性也越好。 色纯度:单色光是色纯度最高的颜色,当单色光掺入白光的成分越多时,色纯度就越低。 显色指数:光源对物体真实颜色的呈现程度称为光源的显色性。显色指数用Ra表示, Ra值越大,光源的显色性越好。显色指数中R1至R8的平均值就是Ra值。 R9至R15的含义:R9浓红色;R10浓黄色;R11浓绿色;R12浓蓝色;R13 亮的浅黄-粉红色;R14中等程度的橄榄绿色;R15东方女性肤色。 光度参数 光通量:光是电磁波辐射到人的眼睛,经过视觉神经转换为光线。光源发射并被人的眼睛接收的能量之和即为光通量。单位:流明(Lm) 光效:光源所发出的总光通量与该光源所消耗的电功率(瓦)的比值,称为该光源的光效。单位:流明/瓦(Lm/瓦)。 光辐射功率:单位时间内,发射的所有波长成份的辐射能量。单位是W。 1、Duv说明:

积分球灯具检验测试报告解读

色度图中,色 品坐标以X、Y表示,在CIE1976色度图中则以U、V表示, 灯具测试报告解读 培训目的:能看懂灯具测试报告。 一、使用积分球测试灯具报告 色度参数 色品坐标X、Y、U、V:CIE1931 根据色品坐标计算出相关色温。 相关色温:用绝对温度“K”表示,当光源所发出的光的颜色与黑体在某一温度下辐射的颜色相同时, 黑体的温度就称为该光源(灯具)的色温. 色温在2500-3300K的光源,颜色偏红,给人一种温暖的感觉。色温超过时,颜色偏兰,给人一种清冷的感觉。

暖白:2500-4000K 中性白:4000-5500K 正白光:5500-7000K 冷白光:7000以上 注:色温只对白光有意义,对于单色光,就要看它的主波长了。 主波长:用某一光谱色,按一定比例与一个确定的标准照明体相混合而匹配出的样 长就是样品色,该光谱色的波长就是样品色的主波长。 色比:光源的红、绿、蓝的三色比例。 峰值波长:光谱发光强度或辐射功率最大处所对应的波长。通常你所看到的一束光,它并非是单一波长的光,它是由很多波长的光组合而成的。其中,某一波长的 光的能量相对其它波长的光能量都大,则这一波长就是该束光的峰值波长。 半宽度:对于一个LED器件,其所发的光会在峰值λP处有所展开,其波长半宽度通常为10—30nm。对于单色光,半宽度越小,说明LED器件的材料越纯,性能越 均匀,晶体的完整性也越好。 色纯度:单色光是色纯度最高的颜色,当单色光掺入白光的成分越多时,色纯度就越低。显色指数:光源对物体真实颜色的呈现程度称为光源的显色性。显色指数用Ra表示,Ra值越大,光源的显色性越好。显色指数中R1至R8的平均值就是Ra值。R9至R15的含义:R9浓红色;R10浓黄色;R11浓绿色;R12浓蓝色;R13 亮的浅黄-粉红色;R14中等程度的橄榄绿色;R15东方女性肤色。 光度参数 光通量:光是电磁波辐射到人的眼睛,经过视觉神经转换为光线。光源发射并被人的眼睛接收的能量之和即为光通量。单位:流明(Lm)

LED灯具成品检验标准

成品检验规范 文件编号:版本号: 编制:日期: 审核:日期: 批准:日期: 生效日期:受控状态:

文件变更记录

1、目的 规范成品入库及出货检验流程,确保出货产品满足客户的需求,不断的提升品质,提高客户的满意度,模拟客户对产品的验证。 2、适用范围 适用于所有LED 灯具产品入库及出货检验。 3、定义 3.2 检验面的定义 A 面:直接看到的区域如:玻璃面,铝基板,LED,透镜面。 B 面:不在直视范围,但暴露在外的面,如:灯具两侧面、散热片、铝型材、外壳,电源等。 C 面:正常使用时看不到的面。须拆卸的面。 4、检验条件 4.1 检验光源:普通日光灯灯源500lux. 4.2 检验角度:如图一所示,产品与水平视线成30°,并在检验时±15°旋转产品。 4.3 外观检验距离:未点亮距眼睛30cm±10cm,与眼睛成一条直线,点亮后距离 100cm±10cm. 4.4 外观检验时间:10s/每个面。 4.5 测试设备:见测试项目内仪器。 5、引用标准 5.1 GB/T 2828.1-2003 Ⅱ级按接受质量限(AQL)检索的逐批检验抽样计划。 5.2 AQL 允收质量水平:MIN=1.5 MAJ=0.65 CRI=0(抽样方案主要以0.65 抽取数量)。 5.3 样本数小于或者等于20PCS 时全检处理。 5.4 样本的抽取原则:抽取为上中下抽取力求均匀/每板,随机性。

6、作业内容 6.1 成品送检 6.1.1 生产作业完成包装成品,移交待检区,开出【送检单】通知OQC 进行检验。 6.1.2 送检原则:生产按4H 的产量或者4H 内生产完的订单进行送检。 6.1.3 产线送检验时须经过IPQC 在【送检单】签字确认,确认是否完成所有生产工序。 6.2 OQC 检验 6.2.1 OQC 抽样按5.1-5.4 执行。 6.2.2 OQC 核对订单要求、工程技术测试要求、检验规范、检验作业指导、图纸、客户要 求进行检验。 6.2.3 检验项目与判定标准按7检验内容执行,检验完毕在【送检单】备注后知会生产入 库。 6.3 检验标识记录 6.3.1 检验后如实填写【出货检验报告】 6.3.2 检验不合格在送验批上标识不合格标签,并开出【返工通知单】性能/结构问题给工程 给出返工方案生产执行,外观问题直接返工重检,若对品质判定有疑义则由工程,品质进行评估会签,达成一致放行,若达不成一致则由事业部负责人裁决,【返工通知单】一式三联,第一联品质部保留,第二联PMC 保留,第三联责任部门。 6.3.3 生产返工完毕在【送检单】备注复检OK 经IPQC 确认后送OQC 重新抽验,连续出现 3 批检验不合格在开出【品质异常报告】给相关部门/人员责任到人,并给出处理意见。 6.3.4 检验合格每箱盖OQC PASS 印章,若订单上有要求中性包装的盖无公司LOGO 标志的 印章。 6.3.5 若急需出货,因检验,老化,测试,时间不够则由PMC 提出特采申请,技术,品质进 行评估会签,达成一致放行,若达不成一致则由生产部负责人裁决。 6.3.6 样品检验以工程部工程师的要求的测试项目为准,标准或特殊要求以工程师的签名为准。 6.4 仓库复检 6.4.1 库存超过1 个月的出货须PMC 安排仓库送OQC 检验,检验按6.1-6.3 执行。 6.4.2 库存超过半年的出货须PMC 安排生产线,重新老化,包装,OQC 检验流程。 6.5 入库 6.5.1 生产入库仓库收货,核对数量的同事须核对是否有OQC PASS 印章,若无则不允许入库。 6.5.2 仓库对库存品须做到先进先出,产品防潮,防水,防撞同一批次,型号,不可混放等。 6.5.3 仓库在出货装车时通知OQC 去现场确认,并拍照装车状况记录存入电脑。 6.6 抽样检验转移规则(加严、正常、放宽) 6.6.1 从正常检验到放宽检验:必须同时满足以下两个条件,缺一不可: A. 生产稳定,连续一周检验无异常。 B. 品质部门认为放宽检验可取。 6.6.2 从放宽检验到正常检验:进行放宽检验时,如果出现下面任何一种情况,就必须转回 正常检验: A、有一批检验不被接收。 B、生产不稳定或延迟。 C、品质部门认为有必要恢复正常检验。 6.6.3 加严检验以下有其中一条则进行加严检验。 A. 有客户投诉。

灯具IES测试报告.IES中文

第1页 灯具参数 灯具名称: 8095-S 报告编号: 2017112902测试编号: 光源规格型号: 2835 总光源光通量: 1574.63 lm 光源个数: 260发光面直径: mm 发光面长度: 900mm 测量模式: Type C 电压: 121.1 V 电流: 0.364 A 功率: 44.0 W 功率因数: 0.996镇流器型号: 发光面宽度: 70mm 发光面高度: 1500mm 光学部件描述: 2835-0.2W 光度结果 灯具光通量: 1574.63 lm 发光效率: 35.787 lm/W 中心光强: 491.17cd 最大光强: 510.224cd 光束宽度(10%Imax): Left: -104.3 Right:59.1 最大光强角度: C:0.0 G:15.0 半峰边角(50%Imax): Left: -74.1 Right:51.3灯具效率: 100.00%上射光通比: 0.0%下射光通比: 100.0% C0/C18090°°45° 60°510.2 408.2306.1204.1102.0-180°180°0°cd 102.0 204.1306.1408.2510.2cd C90/270 90°° 45° 60°510.2 408.2306.1204.1102.0-180°180° 0°cd 102.0 204.1306.1408.2510.2cd

C\G0.0 1.0 2.0 3.0 4.0 5.0 6.07.08.09.0 0.0491.2480.9479.8489.9501.7507.5479.8483.3482.9495.0 45.0491.2479.7471.9489.8486.2495.1498.0488.7495.7468.9 90.0491.2479.7471.9489.8486.2495.1498.0488.7495.7468.9 135.0491.2503.1505.4498.9487.5481.9484.8499.3502.2503.3 180.0491.2503.1505.4498.9487.5481.9484.8499.3502.2503.3 225.0491.2474.2471.6481.9489.0493.3489.3476.8466.7462.6 270.0491.2474.2471.6481.9489.0493.3489.3476.8466.7462.6 315.0491.2480.9479.8489.9501.7507.5479.8483.3482.9495.0 360.0491.2480.9479.8489.9501.7507.5479.8483.3482.9495.0 C\G10.011.012.013.014.015.016.017.018.019.0 0.0492.8486.1502.2489.9506.8510.2502.6505.8479.3481.9 45.0472.0481.2477.7487.3476.2464.5457.8461.6469.2473.6 90.0472.0481.2477.7487.3476.2464.5457.8461.6469.2473.6 135.0494.6488.3496.8475.4485.9491.9464.6475.9460.9453.9 180.0494.6488.3496.8475.4485.9491.9464.6475.9460.9453.9 225.0468.7477.8480.2473.0460.8449.4446.8453.3460.4434.8 270.0468.7477.8480.2473.0460.8449.4446.8453.3460.4434.8 315.0492.8486.1502.2489.9506.8510.2502.6505.8479.3481.9 360.0492.8486.1502.2489.9506.8510.2502.6505.8479.3481.9 C\G20.021.022.023.024.025.026.027.028.029.0 0.0490.9499.2498.4486.4472.1464.2465.4471.7476.3472.8 45.0469.0449.2443.1437.4442.3442.1428.5442.2428.4414.7 90.0469.0449.2443.1437.4442.3442.1428.5442.2428.4414.7 135.0473.0460.3447.0438.0440.2445.1447.5440.8426.6413.5 180.0473.0460.3447.0438.0440.2445.1447.5440.8426.6413.5 225.0448.2438.3443.6421.9428.1431.4406.5405.2401.6391.9 270.0448.2438.3443.6421.9428.1431.4406.5405.2401.6391.9 315.0490.9499.2498.4486.4472.1464.2465.4471.7476.3472.8 360.0490.9499.2498.4486.4472.1464.2465.4471.7476.3472.8 C\G30.031.032.033.034.035.036.037.038.039.0 0.0459.8456.6437.2454.9444.5427.9440.3426.9411.7425.9 45.0409.8423.9419.0416.7391.3393.3396.0393.9384.0371.0 90.0409.8423.9419.0416.7391.3393.3396.0393.9384.0371.0 135.0406.0407.7411.0412.0402.9388.8390.0370.9372.1376.0 180.0406.0407.7411.0412.0402.9388.8390.0370.9372.1376.0 225.0407.7397.0381.3391.6370.6371.9373.7368.3354.8340.5 270.0407.7397.0381.3391.6370.6371.9373.7368.3354.8340.5 315.0459.8456.6437.2454.9444.5427.9440.3426.9411.7425.9 360.0459.8456.6437.2454.9444.5427.9440.3426.9411.7425.9

飞利浦830-2000LM LED光源配光曲线测试报告

室内灯具光度数据 C角度范围: 0度 - 360度C角度间隔: 10.0度γ角度范围: 0度 - 180度γ角度间隔: 1.0度 测试速度: 快速测试系统: 远方(EVERFINE)GO-2000B_V1系统 V2.0.270环境温度:24.7℃环境湿度:53.0% 测试距离:10.000米 [K=0.9475] 测试人员:RD001 测试日期:2012-4-11备注:

灯 具 等 光 强 曲 线 -90-80-70-60-50-40-30-20-100 102030405060708090 水 平 角 度(DEG) 垂 直 角 度(D E G ) Imax:4166(H-0.5,V-1.0) (At:C=120.0,Gamma=1.0)单位: cd 10% 416.620% 833.230% 125040% 166650% 208360% 250070% 291680% 333390% 3750 C 角度范围: 0度 - 360度C 角度间隔: 10.0度γ角度范围: 0度 - 180度γ角度间隔: 1.0度 测试速度: 快速测试系统: 远方(EVERFINE)GO-2000B_V1系统 V2.0.270环境温度:24.7℃环境湿度:53.0% 测试距离:10.000米 [K=0.9475]测试人员:RD001 测试日期:2012-4-11备注:

灯 具 有 效 平 均 照 度 图 1m 3.281ft 48.52cm 1.592ft 2854,4172lx 265.1,387.6fc 2m 6.562ft 97.04cm 3.184ft 713.4,1043lx 66.28,96.89fc 3m 9.843ft 145.57cm 4.776ft 317.1,463.5lx 29.46,43.06fc 4m 13.12ft 194.09cm 6.368ft 178.4,260.7lx 16.57,24.22fc 5m 16.4ft 242.61cm 7.96ft 114.2,166.9lx 10.61,15.50fc 高度 Eavg,Emax 直径 光束角:27.27度 光通输出:557.3 lm 注:曲线为灯具在不同投射距离下的照射区域及区域内平均照度. C 角度范围: 0度 - 360度C 角度间隔: 10.0度γ角度范围: 0度 - 180度γ角度间隔: 1.0度 测试速度: 快速测试系统: 远方(EVERFINE)GO-2000B_V1系统 V2.0.270环境温度:24.7℃环境湿度:53.0% 测试距离:10.000米 [K=0.9475]测试人员:RD001 测试日期:2012-4-11备注:

室内灯具光度数据

室内灯具 光度数据 C角度范围: 0度 - 360度C角度间隔: 90.0度γ角度范围: 0度 - 180度γ角度间隔: 1.0度 测试速度: 快速测试系统: 远方(EVERFINE)GO-2000B_V1系统 V2.0.295环境温度:25.3℃环境湿度:65.0% 测试距离:10.106米 [K=1.0000] 测试人员:DAMIN 测试日期:2017-10-26备注:品质部:稳态

灯具环带光通量 环带光通量: γ 10 0- 10 20 10- 20 30 20- 30 40 30- 40 50 40- 50 60 50- 60 70 60- 70 80 70- 80 90 80- 90 100 90-100 110100-110 120110-120 130120-130 140130-140 150140-150 160150-160 170160-170 180 170-180 C0C90C180C270γ(°)Φ环Φ总%lum,lamp 单位:°光强:cd 单位:lm 38.9538.5037.5937.84 3.664 3.664 5.26,5.2638.3838.2436.7736.9010.7614.4320.7,20.735.1835.6032.5932.3516.6531.0844.6,44.629.0129.1323.2122.6218.9950.0671.8,71.817.3918.079.561 6.81515.3365.3993.9,93.90.55060.55430.26590.2615 3.84469.2499.4,99.40.22540.18920.13060.12620.254869.4999.7,99.70.12620.0901 0.0541 0.0676 0.128869.6299.9,99.90.0496 0000.053669.67100,10000000.0024 69.68100,1000000069.68100,1000000069.68100,1000000069.68100,1000000069.68100,1000000069.68100,1000000069.68100,1000000069.68100,1000 69.68 100,100 C 角度范围: 0度 - 360度C 角度间隔: 90.0度γ角度范围: 0度 - 180度γ角度间隔: 1.0度 测试速度: 快速测试系统: 远方(EVERFINE)GO-2000B_V1系统 V2.0.295环境温度:25.3℃环境湿度:65.0% 测试距离:10.106米 [K=1.0000]测试人员:DAMIN 测试日期:2017-10-26备注:品质部:稳态