SPECIFICATION

MODEL

DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER

OUTPUT

VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE

Note.5EFFICIENCY (Typ.)INPUT

FUNCTION

INRUSH CURRENT (Typ.)OVER TEMPERATURE WORKING TEMP.

OUTPUT OK SIGNAL

REMOTE ON/OFF CONTROL WORKING HUMIDITY

STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION

MTBF DIMENSION OTHERS

NOTE

PACKING

OVERLOAD OVER VOLTAGE

DC CURRENT (Typ.)CURRENT (AT NO LOAD)500ms, 50ms at full load 19 ~ 72VDC

24.2A/19VDC 24.8A/24VDC 12A/48VDC Max. 0.2A/48VDC 60A/48VDC

105 ~ 125%rated output power

Protection type :Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover 16 ~ 19V

805(L-48V,H-24V,H-48V), 855(L-24V), 905(L-12V), 955(H-12V) (TSW2 : detect on heatsink of o/p diode)30.8 ~ 35.2V 62 ~ 68V 16 ~ 19V

30.8 ~ 35.2V

62 ~ 68V

Protection type : Shut down o/p voltage, re-power on to recover 805(TSW1 )detect on heatsink of power transistor

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

-20 ~ +60(Refer to output load derating curve)Please refer to function manual

Open collector signal low when PSU turns on, max. sink current :10mA 20 ~ 90% RH non-condensing

-40 ~ +85

, 10 ~ 95% RH

0.02%/(0 ~ 50)

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes 196.3K hrs min. MIL-HDBK-217F (25)215*115*50mm (L*W*H)

1.15Kg; 12pcs/14.8Kg/0.92CUFT

86%

88%

89%

87%

8A/72VDC 6A/96VDC

60A/96VDC

Max. 0.1A/96VDC 89%

90%

0.5%

0.5%

0.5%

0.5%72 ~ 144VDC

0.5%

0.5%

0.5%0.5%0.5%0.5%0.5%0.5%1.0% 1.0% 1.0% 1.0% 1.0% 1.0%150mVp-p

11 ~ 15V 150mVp-p 23 ~ 30V 150mVp-p 46 ~ 60V 150mVp-p 11 ~ 15V 150mVp-p 150mVp-p 23 ~ 30V 46 ~ 60V 12V 40A 0 ~ 40A 480W 24V 21A 0 ~ 21A 504W 48V 10.5A 0 ~ 10.5A 504W 12V 40A 0 ~ 40A 480W 24V 48V 21A 10.5A 0 ~ 21A 0 ~ 10.5A 504W 504W SD-500L-12SD-500L-24SD-500L-48SD-500H-12SD-500H-24SD-500H-481. All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

SAFETY STANDARDS

EMS IMMUNITY IEC60950-1 CB approved by TUV

Compliance to EN55022 (CISPR22)Class B Compliance to EN61000-4-2,3,4,6,8; ENV50204, light industry level, criteria A RIPPLE & NOISE (max.)Note.2VOLTAGE TOLERANCE Note.3EMI CONDUCTION & RADIATION WITHSTAND VOLTAGE

ISOLATION RESISTANCE I/P-O/P:2KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 2570%RH

ENVIRONMENT SAFETY &EMC

(Note 4)

PROTECTION

DC input active surge current limiting

Protections: Short circuit / Overload / Over voltage / Over temperature

/ Input polarity(by fuse)

2000VAC I/O Isolation

Forced air cooling by built-in DC fan with fan speed control function Output OK Signal

Built-in remote ON-OFF control Built-in remote sense function 3 years warranty

Wide 4:1~2:1 DC input range (24V: 19~72VDC, 96V:72~144VDC)Features :

Mechanical Specification

Derating Curve

Static Characteristics

Case No. 912A

Unit:mm

L O A D (%)

INPUT VOLTAGE (VDC)

192436487296144

90for SD-500L for SD-500H

100807570

605040

Block Diagram

AMBIENT TEMPERATURE ()

L O A D (%)

20

4060

80100-2001020304045506070Ta=25

BOOST fosc : 65KHz PWM fosc : 110KHz

FAN

O.V.P.-V +V RECTIFIERS

&FILTER

-S

+S

CIRCUIT DETECTION POWER

AUX REMOTE CONTROL

ON/OFF

OUTPUT LIMITING

ACTIVE CURRENT INRUSH CONTROL

ING I/P

SWITCH-POWER FILTER

EMI PWM BOOST

BOOST CONTROL O.T.P.

O.L.P.

Control P (CN3) : JST B6B-PHDSS or equivalent

in No.Assignment Pin No.Pin No.15423

6

Assignment

Assignment +S -S

OUTPUT OK

RCG

RC GND Mating Housing JST PHDR-06VS or equivalent

Terminal JST SPHD-002T-P0.5

or equivalent

DC Input Terminal Pin No.Assignment

Pin No.Pin No.

14,5326,7

Assignment Assignment

FG

DC INPUT V-+V

DC INPUT V+-V 16

15C L

4-M4 L=5mm 5-M3 L=3mm

27.5

177.5

32.5150117.5

10

95

50

32.5

50.5

115

47.7

38.95

32.5

150

2156-M4 L=5mm

25

50

Air flow

direction

14 max.

135

LED

+V ADJ.

CN32 16 5

54

67

1

238.610

only for SD-500L-12

(HORIZONTAL)

1.Remote ON/OFF

(1)Remote ON/OFF control becomes available by applying voltage in CN3(2)Table 1.1 shows the specification of Remote ON/OFF function

(3)Fig.1.2 shows the example to connect Remote ON/OFF control function

Table 1.1 Specification of Remote ON/OFF Fig.1.2 Examples of connecting remote ON/OFF

Connection Method Output on SW Open Fig. 1.2(A)

Output off SW Close 1K

RCG

RC

SW

5V

1K

RC

V

RCG

(A)Using external voltage source

(B)Using external voltage source

2.Output OK signal

"Output OK" is an open collector signal.

It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external signal ;the other is sending out a voltage signal.The maximum sink current is 10mA and the maximum external voltage is 13V.2-1 Sink current :

2-2 Voltage signal :

Between O/P OK(pin3) and GND(pin4)0 ~ 0.5V 12 ~ 13V

Output Status

ON OFF

V=0~0.8Vdc V=4~10Vdc

Fig. 1.2(B)

Function Description of CN3

Function Manual

Pin No.Function Description

1356

42+S O/P OK RC RCG

GND -S

Open collector signal, reference to pin4(GND). Low when PSU turns on.The maximum sink current is 10mA and the maximum

external voltage is 13V.Remote ON/OFF

Remote ON/OFF ground

These pins connect to the negative terminal (-V).Negative sensing.The -S signal should be connected to the negative terminal of the load.The -S and +S leads should be twisted in pair to minimize noise pick-up effect.The maximum line drop compensation is 0.5V.

Positive sensing.The +S signal should be connected to the positive terminal of the load.The +S and -S leads should be twisted in pair to

minimize noise pick-up effect.The maximum line drop compensation is 0.5V.+S 1-S 2

O/P OK RC GND

RCG CN356

+V ADJ.+Vo +Vo -Vo -Vo TB1

CN3

1 5

2 6

The remote sensing compensates voltage drop on the load wiring up to 0.5V.

3.Remote Sense

+S 1-S 2

O/P OK RC GND

RCG CN356

+V ADJ.+Vo +Vo -Vo -Vo TB1

CN3

1 5

2 6

-

+

LOAD -S (pin2)

Sense lines should be twisted in pairs

+S (pin1)