description :
Geh?use / case: SH
A 23,3 max.mm
B 18,5 max.mm
C 11,5 max.mm
D 10,0 ± 0,2mm
E 5,0 ± 0,2mm
F 19,6 ± 0,3mm
G 2,1 ± 0,1mm H
0,4 typ.
mm
Eigenschaften / properties
Wert / value
Einheit / unit
tol.
Leerlauf-Induktivit?t /inductance
DC-Widerstand /DC-resistance Nennstrom /rated current Nennspannung /rated voltage
33%+20°C
Prüfspannung / testing voltage
1500 V, 50 Hz 5mA, 2 sec.
SBa
Version 22010-05-17BKo Version 1
2009-02-17
Name
?nderung / modification
Datum / date
übertemperatur / temperature rise: < 55 K
Klimabest?ndigkeit/ climatic class: 40/125/21.............................................................
Datum / date
CURRENT-COMPENSATED CHOKE WE-LF SMD
mH R DC WAYNE KERR WK3260B/WK3265
für/for L 0 und/and R DC U N
I N Luftfeuchtigkeit / humidity:
Class F Betriebstemp. / operating temperature: -40°C - +125°C HP 34401 A für/for I N
...............................................................................
0,40max.
1,20±30%
B Elektrische Eigenschaften / electrical properties:
250
50 Hz
Unterschrift / signature
Kontrolliert / approved
Würth Elektronik
..................................................................................
...............................................................................DATUM / DATE : 2010-05-17
max.A Testbedingungen / test
conditions
V
?A Mechanische Abmessungen / dimensions :
10 kHz / 0,1 mA / 20°C
C L?tpad / land pattern.:
Umgebungstemperatur / temperature:L O 27,00D Prüfger?te / test equipment:
E Testbedingungen / test conditions:
@ 20 °C @ 70 °C UL94 HB It is recommended that the temperature of the part does not exceed 125°C under worst case operating conditions.
G Eigenschaften / general specifications:
Sockel / base:Draht / wire:UL94 V-0F Werkstoffe & Zulassungen / material & approvals:
Kleber / glue:
Freigabe erteilt / general release:
Kunde / customer
Abstandhalter / spacer:
UL94 V-0
Würth Elektronik eiSos GmbH & Co. KG
Geprüft / checked This electronic component is designed and developed with the intention for use in general electronics equipments. Before incorporating the components into any equipments in the field such as aerospace, aviation, nuclear control, submarine, transportation, (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc. where higher safety and reliability are especially required or if there is possibility of direct damage or injury to human body.In addition, even electronic component in general electronic equipments, when used in electrical circuits that require high safety, reliability functions or performance, the sufficient reliability evaluation-check for the safety must be performed before use. It is essential to give consideration when to install a protective circuit at the design stage.
[mm]
description :
SBa
Version 22010-05-17
BKo
Version 1
2009-02-17
Name
?nderung / modification
Datum / date
H Einfügungsd?mpfung / insertion loss:
Freigabe erteilt / general release:
Geprüft / checked Kontrolliert / approved
Datum / date
Würth Elektronik
Würth Elektronik eiSos GmbH & Co. KG
.................................................................................................................................................................
CURRENT-COMPENSATED CHOKE WE-LF SMD
DATUM / DATE : 2010-05-17
Unterschrift / signature ...............................................................................
.............................................................
Kunde / customer
010
20
30
40
50
60
0,01
0,1
1
10
E i n f üg u n g s d ?m p f u n g / i n s e r t i o n l o s s [d B ]
Frequenz / frequency [MHz]
typischer D?mpfungsverlauf / typical attenuation curve
This electronic component is designed and developed with the intention for use in general electronics equipments. Before incorporating the components into any equipments in the field such as aerospace, aviation, nuclear control, submarine, transportation, (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc. where higher safety and reliability are especially required or if there is possibility of direct damage or injury to human body.In addition, even electronic component in general electronic equipments, when used in electrical circuits that require high safety, reliability functions or performance, the sufficient reliability evaluation-check for the safety must be performed before use. It is essential to give consideration when to install a protective circuit at the design stage.
description :
Gurtspezifikation / Tape specification:
A24mm
B4mm
C44mm
a330 ± 2,0mm
b21 ± 0,8mm
c
13 ± 0,5mm
d
150 ±1,0mm
e
48,4mm
f44mm
165 to 180°
SBa Version 22010-05-17
BKo Version 12009-02-17
Name?nderung / modification Datum / date Datum / date Unterschrift / signature
Würth Elektronik
.............................................................
Geprüft / checked Kontrolliert / approved
Würth Elektronik eiSos GmbH & Co. KG
I Rollenspezifikation / tape and reel specification:
Rollenspezifikation / Reel specification: Freigabe erteilt / general release:
Kunde / customer
..................................................................................
CURRENT-COMPENSATED CHOKE WE-LF SMD
DATUM / DATE : 2010-05-17
............................................................................... ...............................................................................
The force for tearing off cover tape is
10 to 130 grams in arrow direction
feeding direction
? c
a b d
A B
e
f
C
This electronic component is designed and developed with the intention for use in general electronics equipments. Before incorporating the components into any equipments in the field such as aerospace, aviation, nuclear control, submarine, transportation, (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc. where higher safety and reliability are especially required or if there is possibility of direct damage or injury to human body.In addition, even electronic component in general electronic equipments, when used in electrical circuits that require high safety, reliability functions or performance, the sufficient reliability evaluation-check for the safety must be performed before use. It is essential to give consideration when to install a protective circuit at the design stage.
分销商库存信息: WURTH-ELECTRONICS 7446630027