ISDDQAEE0006---Machine Hi-Pot&Ground Bond Test SOP

ISDDQAEE0006---整机高压测试与接地电阻测试作业规范

1. Test Purpose

[测试目的]

The purpose of this test is to check the machine's electrical strength and resistance of grounding path. [本测试的目的是确定机器的抗电强度和接地阻抗]

2. Test Sample Size

[测试抽样大小]

 The test quantity is 1-2pcs.

[测试数量为1-2台]

3. Test Implement/Equipemnt

[测试工具/测试设备]

Extech 7440 dielectric strength tester

[Extech 7440 安规介电分析仪, AIO样机一台 ]

4.Hi-Pot Block Diagram

AIO samples x 1

Printe r

Extech

7440 Lin

H.V.

Retur

Extech

7440

Curre

Retur

Fram

Power

neutral

Groun

5. Test Location and Environment Control

[测试场所和测试环境]

22±5℃ , 55±5%RH

[温度范围:22.0±5℃,湿度范围:55±5% R.H.]

6. Test Procedure

[测试步骤]

step1.Check the base function of test machine,specially define the Fax function.

[步骤1. 检查整机的功能,特别是Fax 功能的确定.]step 2.Connect the machine to Extech 7440 dielectric strength tester,as P1 show.

[步骤2. 按右图P1示的接线方法将被测物和7440测试仪连接.]

P1step 3. Turn on the 7440 tester,press AC-W key ,enter the offset setting.Connect the 7440 Return

line to the Current H.V.line,then press Test key ,the result show the tester's own offset.

[步骤3. 7440 offset: 打开7440电源开关,按AC-W 键进入offset 设定.将7440 Return 线和H.V.线

接成环路,按Test 键测试,结果即为仪器本身的漏电流.

step 4.Set the parameter on the 7440 tester include: test Voltage,HI-Limit,LO-Limit,Ramp time,Dwell time.

[步骤4. 设定7440参数:测试电压、电流上限、 电流下限、缓升时间、测试时间.]

step 5.Press the Tset key to test.

[步骤5.按下Test 键进行测试.]

step 6. The test pass will have a "du" sound,the LCD will show Pass and the green light will turn on.If the test fail, the red light will turn on and the alarm will on until you turn off.

[步骤6.测试通过,将会响一声短暂的“嘟”声,同时显示屏显示Pass,Test 键绿色指示灯也将会亮.如果测试失败, 则红色指示灯亮起,并响起警报音直到你关闭为止.]

step7. Store test result pictures and record the test data.

[步骤7. 保存测试结果图片并记录下测试数据.]

step8.Check test machine function again.

[步骤8.再次检查整机的功能.]

Line&Neutr a l Ground

step 9.Connect the machine to Extech 7440 dielectric strength tester,as P2 at bottom show.

[步骤9. 按页底P2所示的接线方法将被测物和7440测试仪连接.]

step 10. Turn on the 7440 tester,press Grounding key ,enter the offset setting.Connect the 7440 Return line

to the Current line,then press Test key,the result show the tester's offset.

[步骤10. 7440 offset: 打开7440电源开关,按Grounding键进入offset设定.将7440 Return线和Current线接成环路按Test键测试 ,结果为仪器本身的漏电流.

step 11.Set the parameter on the 7440 tester include: Test Current,Test Voltage,HI-Limit,LO-Limit,Dwell time. [步骤11. 设定7440测试参数包括:输出电流、输出电压、接地阻抗上限、接地阻抗下限、测试时间.

step 12.Press the Tset key to test.

[步骤12.按下Test键进行测试.]

step13. The test pass will have a "du" sound,the LCD will show Pass and the green light will turn on.If the test fail, the red light will turn on and the alarm will on until you turn off.

[步骤13.测试通过,将会响一声短暂的“嘟”声,同时显示屏显示Pass,Test键绿色指示灯也将会亮.如果测试失败,则红色指示灯亮起,并响起警报音直到你关闭为止.]

step14.Check test machine function.

[步骤14.检查整机的功能.]

step15. Store test result pictures and record the test data.

[步骤15. 保存测试结果图片并记录下测试数据.]

7. Test Record Table

[测试记录表]

Test Item Machine NO.

Ramp

Time

Test

Time

Hi-limit

Test

Result

Remark

Dielectri

c

1Sec60Sec10mA

Test Item Machine NO.Hi-limit

Test

Result

Remark Output Voltage

AC 3000V

Output Current Test Time

Ground Bond 100mΩ

P2

30A 120Sec Power Cord

Ground