搜档网
当前位置:搜档网 › CATIA-V5-6R2013-GA-P3-Win64安装方法

CATIA-V5-6R2013-GA-P3-Win64安装方法

CATIA-V5-6R2013-GA-P3-Win64安装方法
CATIA-V5-6R2013-GA-P3-Win64安装方法

HOW TO GET THE TARGET ID OF YOUR MACHINE

========================================

If you want to run the software with a nodelock license, you need to

provide the target ID of your machine when ordering the license key.

The following explains how to obtain this ID.

1. IF USING NEW DSLS LICENSING MODE

-----------------------------------

The target ID is a character string composed of 3 letters, followed by a dash, followed by 16 hexadecimal characters.

ex: GTF-E502DD633AF579A0

1/ Open a Command Prompt window and go to the CDROM drive root folder.

2/ Run "DSLicTarget.exe -t"

This will display the target ID of the machine.

The target ID is also displayed:

- in the Tools/Options/Licensing panel when running the application.

- in the Nodelock Key Management (DSLS) tool, from Start/Programs/CATIA/Tools.

2. IF USING LEGACY LICENSING MODE (LUM)

---------------------------------------

From an Explorer window, go to the CDROM drive root folder and

double-click on i4tgtid.exe.

A message box containing the win32mac target ID of the machine is displayed.

The target ID is a character string composed of 8 hexadecimal characters.

Make sure that the string "win32mac" is also displayed alongside the target ID.

ex: 1C39FA57 win32mac

Depending on the network configuration of your machine, the win32mac target ID might not be available or might be equal to 00000000.

In this case, you have to use another tool, i4target.exe, in command-line mode:

1/ Open a Command Prompt window and go to the CDROM drive root folder.

2/ Run "i4target.exe -z"

This will list enabled network adapter GUIDs that can be used for the target ID.

2/ Run "i4target -v"

This will help to map GUIDs to more friendly names.

3/ Run "i4target.exe -d {12345678-90AB-CDEF-1234-567890ABCDEF}"

where {12345678-90AB-CDEF-1234-567890ABCDEF} matches the desired network adapter GUIDs.

4/ Run i4target.exe or i4tgtid.exe

You should obtain a win32mac target ID.

Note: Do not repeat step 2 once you have a valid win32mac target ID.

The target ID is also displayed:

- in the Tools/Options/Licensing panel when running the application.

- in the Nodelock Key Management tool (LUM), from Start/Programs/CATIA/Tools.

此教程是安装_Win64后总结的安装方法,是否适用于其他版本亦未可知。

步骤:CATIA_V5-6R2013_GA_P3

一、安装前确认安装程序完整。

二、运行setup.exe进行安装,安装位置自选,环境变量位置自选。

安装orbix配置使用默认设置,服务器超时使用默认设置。

不需要安装电子仓客户机,不需要安装联机文档,开始安装。

DSLS_17022013_64bit_SSQ.msi

注意勾选这里。

安装完成时会弹出License Administration Tool 四、右击空白处,选Add new server

以在计算机属性里复制到。

右键刚创建的服务器名,选connect

继续右键,选Display properties,复制其中的Server id

运行DSLS_LicGen_SSQ_v1.1.exe,输入本机名和Server id,点下方Generate!,保存在任意位置。

刚才保存的文件进行加载。

机名,确定所有许可证加载成功。

五、复制Licenses文件夹到C:\ProgramData\DassaultSystemes

六、选择“开始”-“所有程序”-“CATIA P3”-“Tools”

-“Settings Management V5-6R2013”-许可证发放

选择至少一项带EDUCATIONAL或者ACADEMIC的选项。

注意,千万不要选I3D-CATIA-3D INSIGHT 2 Configuration那个选项。

若出现Settings Management V5-6R2013打开后假死或者无内容的情

况,运行DSLS_17022013_64bit_SSQ.msi,卸载服务,再次运行DSLS_17022013_64bit_SSQ.msi,再次安装许可证服务,重复前面过程即可。

七、破解完成

板式家具制作入门

板式家具制作入门(原创连载中,已完成《工具篇》、《材料篇》) 板式家具制作入门 水浸街 前言 一个偶然机会,我今年从百度来到中国木工爱好者论坛,在这个论坛里潜水几个礼拜,拜读了老李、老万、 老崔、小贝以及其他人的大作,自觉获益非浅,使得我下决心购买了一些木工工具,并且也在木友们的帮助之下做出了衣顶柜、书架还有两个练手的板凳。在感谢木友们的帮助同时,也觉得需要为论坛做点贡献, 于是写下了这篇文章,希望对那些想要做家具但不知道怎么入手的朋友有点帮助。 论坛里的木工爱好者,按使用材料偏好大致可以分成两种,一种是实木家具爱好者,追求融入现代美感的实木家具作品,关键技术是榫卯接合、刨、边缘雕刻以及表面油漆处理,一般都使用现代的工具加工而非传统工艺,需要雕刻机、开榫机、电刨压刨、带锯台锯等,这一种爱好者占大多数;另一种是板式家具爱好者,喜欢类似市场上比较普遍的现代板式家具,这类家具的关键技术是设计、开料、五金件接合、封边以及表面粘贴防火板,也有使用油漆作表面处理的,设计、开料对尺寸要求很高,需要的工具有电锯、电钻、雕刻机或修边机等。本文适合板式家具爱好者。 工具篇 锯 台锯、电圆锯、云石机(使用木工锯片)至少要有一种,同时需要一个靠山; 手锯不是必需但最好备上。 板式家具使用工业化生产的标准板制作,一般不需要刨削,锯是保证尺寸准确性最重要的工具。 钻 电钻是必需的。 必备钻头:3 4 5 6 7 8 10 ,可以是麻花钻或者三尖钻,三尖钻开孔不易走位、边缘比较整齐; 必备开孔器:14或或15,用户三合一凸轮开孔,具体大小要看使用的三合一凸轮尺寸而定,当然如果不使用三合一连接可以不用;35,用于安装暗铰链开孔; 沉头钻或砂拉钻不是必需的,但如果备上的话可以提高安装沉头螺丝的效率。 开槽工具 如果安装金属封边条,则开槽工具是必需的,目前我没找到完美的解决方案。论坛里有老万使用云石机开 槽的文章,具体搜索一下就有,操作难度很高。我使用修边机+ T形刀开槽,难题是能买到的T形刀最薄也有1/10英寸(大约),开出的槽有3mm宽不大合用。

CAD制图 油浸式变压器装配图

课程名称电气工程制图 课题名称油浸式变压器装配图 专业电气工程及其自动化 班级 学号 姓名 指导教师 2013 年10 月21 日

湖南工程学院 课程设计任务书 课题名称电气工程制图 题目油浸变压器装配图绘制 专业班级电气工程及其自动化 学生姓名 指导老师 审批 任务书下达日期2013年 10月 14日设计完成日期 2013年 10月 21日

设计内容与设计要求 一.课程性质与目的: 1、性质 《电气工程制图课程设计》是整个教学计划中一个重要的实践性教学环节,是AutoCAD知识的强化训练,它对进一步优化学生的知识能力结构、加强专业技术应用能力培养有重要意义。 2 、目的 通过该课程设计应使学生具备以下基本操作技能: ①能正确无误地读懂所给图纸,进一步熟悉机械标准; ②熟悉AutoCAD命令,灵活并综合运用CAD命令绘图,进一步加深对CAD软件的熟练程度; ③对图纸所表现的产品结构有一个初步的认识。 二.课程设计教学基本内容 用CAD软件绘制油浸变压器的装配图。 三.课程设计的基本要求 独立完成所布置的任务,不得拷贝。

主要设计条件 1、提供电机/接触器/变压器装配图一张。 2、提供上机条件。 说明书格式 1、课程设计封面 2、课程设计任务书 3、说明书目录 4、概述 5、绘图过程 6、总结与体会 7、参考文献 8、附录(图纸); 进度安排 设计时间:1周 星期一上午:下达任务,上课 星期一下午至星期四:绘图 星期五上午:准备说明书 星期五下午:答辩

参考文献 《AutoCAD2007 中文版应用教程》,机械工程出版社,周健编著。 百度百科 百度知道

双玻组件生产安装应用案例

双玻组件生产安装应用案例 双玻组件在光伏电站安装上由于受到玻璃易碎的限制,必须在组件四周析出均匀的、美观的、带有缓冲及防水作用的保护层目前业内的研究方向集中在EVA或POE在层压过程中直接析出,并且需要保持规律的形状。在析出过程中,胶带能起到密封和透气的作用。 因此,交谷太阳能专为光伏电站双玻组件边缘密封研发了JDSOLAR? 502胶带解决方案。产品特点: * 应用方便 * 耐高温,达220℃/428 ℉(30分钟) * 整块揭除后无残胶 针对光伏组件的应用特性,JDSOLAR? 502系列完全满足双玻组件在层压过程中的耐温性以及移除无残胶的要求。此外,交谷太阳能还提供手持式胶带应用工具配合胶带的使用,便于在施贴操作过程中精确定位,极大地提升操作速度和质量。 定制化安装方案增加发电收益 针对地面电站设计的方案,对组件上端的挂钩进行了T型设计,使组件安装时的定位速度比普通组件的还要快。交谷太阳能技术工程师也对安装孔进行了特殊设计,降低了对安装精度甚至是支架设计精度的要求。同时,通过采用背部黏贴的方式,降低组件受力弯曲的程度。 测算显示,采用交谷太阳能定制化方案,4个人用53秒的时间就能安装一块组件,这一速度超过了单玻组件的安装速度,比同类安装方案节省了近50%的人工和时间。分布式电站最耗时的是做基础、组装支架、安装支架等。为此,交谷太阳能的技术工人把一部分支架和螺丝、前后支架在厂内安装好,这样,整个分布式电站的安装时间节省了近30%,还节省了一部分材料成本。此外,在不增加成本的前提下,将支架作了可调节设计,不同地区可以根据不用季节的最佳太阳倾角,调整组件和支架之间的角度,从而提高发电量。

门禁系统施工方案

门禁系统的安装方法及措施 1、门禁系统施工方法及措施 1.1、设备安装 (1)前端设备 A、进门处安装读卡器。在读卡器感应范围内,切勿靠近或接触高频或强磁场(如重 载马达、监视器等),并需配合控制箱的接地方式。 B、出门处安装出门按钮。 C、电磁锁安装在门和门框的上沿。 D、为保证安全性和美观性,控制器和电源箱可采用现场安装或安装于弱电井内。现 场安装控制器的优点在于节约线材的使用,控制器安装于弱电井内便于系统日后 的维护和系统的安全,也可将控制器箱安装在读卡器上方,靠近电磁锁处。具体 情况可根据客户选择安装方式。 (2)中控室设备 A、控制主机和键盘安装在立面墙上或置于工作台上。 B、报警装置放置在报警效果较好的位置。 C、由于门禁系统的特殊性,要求对该系统供电良好,建议采用UPS电源,对门禁系 统集中供电。 1.2、设备调试 (1)系统安装完成后,先把一路门禁读卡器信号接入主机,然后单独检测该路门禁读卡器情况,有无漏报、误报情况发生。这一路检测没问题后在接入另一路,如此这样,把每一路都单独检测一遍,确认无误后再把所有线路接齐。 (2)管理人员可以根据使用人员的权限分别授权,如部分人员可以在任意时间进出任意的地点,普通人员只能凭授权卡在授权时间内进出授权范围。当所有门禁点的正常 开启和非法开启时,查看控制中心电脑是否有纪录。 (3)尝试中心电脑因故障或其它原因不能和控制器连接,控制器是否可以独立纪录所控制门点的相关信息,当中心电脑连接后,所有信息是否可以自动上传,是否可以保 证信息纪录的完整性。 (4)做好调试记录。 (5)最后填写竣工报告。

1.3、管线安装 (1)安装工程布线应符合国家规定“电气装置工程施工及验收规范”及国家颁发的有关规范及规定。在管内或线槽内的穿线,应在建筑抹灰及地面工程结束后进行。在穿线前,应将管内或线槽内的积水及杂物清除干净。不同系统、不同电压等级、不同电流类别的线路,不应穿在同一管内或线槽同一槽孔内。导线在管内或线槽内,不应有接头或扭结。导线的接头,应在接线盒内焊接或用端子连接。(小截面系统连接可以绞接,绞接匝数应在五匝以上,然后搪锡,用绝缘带包扎。管线经过建筑物的变形缝,(包括沉降缝、伸缩缝、抗震缝等)处,应采取补偿措施,导线跨越变形缝的两侧应固定,并留有适当余量。接线端子箱内的端子宜选择压接或带锡焊接点的端子板,其接线端子上应有个应的标号。 (2)门禁控制器应安装牢固,不得倾斜,并应有明显标志。安装在轻质隔墙上,应采取加固措施。引入门禁控制器的电缆或电线,配线应整齐、避免交叉,并应固定牢固电缆芯线和所配导线的部均应标明编号,并与图纸不易褪色;端子板与每个接线端,接线不得超过二根;电缆芯和导线应留有不小于20cm余量;导线应绑扎成束;导线引入线穿线后,在进线管处应封堵 (3)门禁控制器的主电源引入线应直接与电源连接,严禁用电源插头,主电源应有明显标志;门禁控制器的接地牢固,并有明显标志。 (4)监控室内接地母线的路由、规格应符合设计要求。施工时应符合下列规:接地母线的表面应完整,无明显损伤和残余焊剂渣,铜带母线光,滑无毛刺,绝缘层不得有老化龟裂现象;接地母线应铺放在地槽或电缆走道中央,并固定在架槽的外侧,母线应平整,不得有歪斜、弯曲。母线与机架或机顶的连接应牢固端;电缆走道上的铜带母线可采用螺丝固定,电缆走道上的铜绞线母线,应绑扎在横档上;系统的工程防雷接地安装,应严格按设计要求施工。接地安装,应配合土建施工同时进行。

油浸式变压器结构图解

结构图解 1-铭牌;2-信号式温度计;3-吸湿器;4-油标;5-储油柜;6-安全气道 7-气体继电器;8-高压套管;9-低压套管;10-分接开关;11-油箱; 12-放油阀门;13-器身;14-接地板;15-小车 电力变压器概述电力变压器是一种静止的电气设备,是用来将某一数值的交流电压(电流)变成频率相同的另一种或几种数值不同的电压(电流)的设备。当一次绕组通以交流电时,就产生交变的磁通,交变的磁通通过铁芯导磁作用,就在二次绕组中感应出交流电动势。二次感应电动势的高低与一二次绕组匝数的多少有关,即电压大小与匝数成正比。主要作用是传输电能,因此,额定容量是它的主要参数。额定容量是一个表现功率的惯用值,它是表征传输电能的大小,以kVA或MVA表示,当对变压器施加额定电压时,根据它来确定在规定条件下不超过温升限值的额定电流。现在较为节能的电力变压器是非晶合金铁心配电变压器,其最大优点是,空载损耗值特低。最终能否确保空载损耗值,是整个设计过程中所要考虑的核心问题。当在产品结构布置时,除要考虑非晶合金铁心本身不受外[3]力的作用外,同时在计算时还须精确合理选取非晶合金的特性参数。国内生产电力变压器较大的厂家有特变电工等。 供配电方式: 10KV高压电网采用三相三线中性点不接地系统运行方式。

用户变压器供电大都选用Y/Yno结线方式的中性点直接接地系统运行方式,可实现三相四线制或五线制供电,如TN-S系统。 电力变压器主要部件及作用①、普通变压器的原、副边线圈是同心地套在一个铁芯柱上,内为低压绕组,外为高压绕组。(电焊机变压器原、副边线圈分别装在两个铁芯柱上) 变压器在带负载运行时,当副边电流增大时,变压器要维持铁芯中的主磁通不变,原边电流也必须相应增大来达到平衡副边电流。 变压器二次有功功率一般=变压器额定容量(KVA)×0.8(变压器功率因数)=KW。 ②、电力变压器主要有: A、吸潮器(硅胶筒):内装有硅胶,储油柜(油枕)内的绝缘油通过吸潮器与大气连通,干燥剂吸收空气中的水分和杂质,以保持变压器内部绕组的良好绝缘性能;硅胶变色、变质易造成堵塞。 B、油位计:反映变压器的油位状态,一般在+20O左右,过高需放油,过低则加油;冬天温度低、负载轻时油位变化不大,或油位略有下降;夏天,负载重时油温上升,油位也略有上升;二者均属正常。

玻璃肋点式幕墙安装方法

玻璃肋点式幕墙安装 (一)玻璃肋点式幕墙构造特点 玻璃肋点式幕墙构造特点:玻璃肋点玻属于全玻璃结构支承体系,以玻璃肋作支承结构,用钢爪将面玻固定在肋玻上。自上而下安装,幕墙玻璃用u型钢槽固定,玻璃就位后,调整其位置直至符合要求。 (二)玻璃肋点式幕墙工艺流程 安装钢槽→安装玻璃肋(打结构胶)→驳接爪安装→面玻安装→打结构胶 (三)玻璃肋点式幕墙施工工艺 1、安装钢槽 严格按照放线定位和设计标高施工,钢槽表面和焊缝刷放锈漆。将下部灰土清理干净。在每块玻璃的下部都要放置不少于2块氯丁橡胶垫块,垫块宽度同槽口宽度,长度不小于100mm。 2、安装玻璃肋(打结构胶) 利用吊挂电动吸盘的手动倒链将玻璃徐徐吊高,使玻璃下端超出下部边框少许。下部工人要及时将玻璃轻轻拉入槽口。在与两块玻璃接缝处打结构密封胶。 3、驳接爪安装 驳接式玻璃幕墙的性能气密性、水密性、抗震性能、荷载传递等重要的幕墙性能指标都是由驳接系统的安装精度来保证的,驳接系统是由驳接座、驳接爪、驳接头等组件有机的连接所构成的,它具有玻璃安装定位、幕墙变形补偿等功能,是点式驳接玻璃幕墙的核心部件。

①驳接座的安装 在结构调整结束后按照控制单元所控制的驳接座安装点进行驳接座的安装,对结构偏移所造成的安装点误差可用偏心座和偏心头来校正,确保驳接座在偏心安装尺寸小于3mm,对角线偏差小于5mm,用激光指向仪校准。 ②驳接爪的安装 在驳接座焊接安装结束后开始定位驳接爪,将驳接爪的受力孔向下,并用水平尺校准两横向孔的水平度(两水平孔偏差小于0.5mm),安装定位销。 ③驳接头的安装 驳接头在安装之前要对其螺纹的松紧度、驳接头与胶垫的配合情况进行100%的检查。先将驳接头的前部安装在玻璃的固定孔上并销紧,确保每件驳接头内的衬垫齐全,使金属与玻璃隔离,保证玻璃的受力部分为面接触,并保证销紧环锁紧密封,锁紧扭矩10N·m,在玻璃吊装到位后将驳接头的尾部与驳接爪相互联接并锁紧,同时要注意玻璃的内侧与驳接爪的定位距离在规定范围以内。 4、面玻安装 ①玻璃到达施工现场后,由现场质检员与安装组长对玻璃的表面质量,公称尺寸进行检测,同时使用玻璃边缘应力仪对玻璃的钢化情况进行全检,玻璃安装顺序采用先上后下,逐层安装调整。 ②玻璃垂直运输:采用电动葫芦进行垂直提升,使用12P重型真空吸盘垂直提升到安装平台上进行定位,安装。在整个过程中减少尺

双玻组件工艺技术规范

双玻组件工艺技术规范-标准化文件发布号:(9456-EUATWK-MWUB-WUNN-INNUL-DDQTY-KII

双玻组件工艺技术规范

双玻双面组件的结构草图如下: 图1:外观示意图 图:2:组件层次结构示意图 图3:双玻组件电池片互联示意图

双玻组件的典型性能参数 注:温度系数仅供参考,具体数据以所使用电池片的温度系数为准。

二、双玻组件的原材料说明 1.电池片 晶体硅太阳组件所用的电池片尺寸为156.75mm×156 .75mm的方片,典型电性能参数如下: 156.75mm×156.75mm晶体硅太阳方片外型图如下: 双面双玻组件由60片156.75mm*156.75mm单晶晶硅电池片串联组成,应 确保每个组件所用电池单片的电性能一致性良好,一般组件的电性能是通过单 片的串、并联来实现的,每个组件所用到的单片都必须确保它们有高度的电性 能一致性,否则将对成品组件的电性能造成较大的影响。在组件制造时,要对 电池片性能进行分选,不允许将电性能差异较大的电池片串联在同一块组件 中。 电池片的选购原则一般如下: a)一般选用国际国内知名厂商生产的电池片(每批的电性能一致性较有保 障);采用当前先进工艺制作的电池片; b)按实际生产需求挑选合适的具有较高的性价比的厂家单片; c)色泽一致性要求要好 d)一批单片要求破损,裂缝,缺角率控制在检验文件规定的范围内。

参考《GB/T12632》单晶体太阳电池总规范,对多晶硅电池来料质量提出要求。 2 钢化玻璃 采用低铁钢化绒面玻璃(又称为白玻璃),厚度3.2mm,在太阳电池光谱响应的波长范围内(320-1100nm)透光率达91.5%以上(镀膜玻璃要求透光率在93.5%以上),对于大于1200 nm的红外光有较高的反射率。此玻璃同时能耐太阳紫外光线的辐射,透光率不下降。玻璃通过或符合国家标准GB/T 9963和GB 2828-87。 用作光伏组件封装材料的钢化玻璃,对以下几点性能有较高的要求 a)抗机械冲击强度 b)表面透光性 c)弯曲度 d)外观 3. EVA 晶体硅太阳电池封材料是EVA,它是乙烯与醋酸乙烯脂的共聚物,化学式结构如下 (CH2—CH2)—(CH—CH2) | O | O — O — CH2 EVA是一种热融胶粘剂,常温下无粘性而具抗粘性,以便操作,经过一定条件热压便发生熔融粘接与交联固化,并变的完全透明,长期的实践证明:它在太阳电池封装与户外使用均获得相当满意的效果。 固化后的EVA能承受大气变化且具有弹性,它将晶体硅片组“上盖下垫”,将硅晶片组包封,并和上层保护材料玻璃,下层保护材料玻璃利用真空层压技术粘合为一体。 另一方面,它和玻璃粘合后能提高玻璃的透光率,起着增透的作用,并对太阳电池组件的输出有增益作用。 EVA厚度在0.4mm~0.6mm之间,表面平整,厚度均匀,内含交联剂,能在130-150℃固化温度下交联,采用挤压成型工艺形成稳定胶层。 EVA主要有两种:①快速固化②常规固化,不同的EVA层压过程有所不同。 采用加有抗紫外剂、抗氧化剂和固化剂的厚度为0.4mm的EVA膜层作为太阳电池的密封剂,使它和玻璃、TPT之间密封粘接。 用于封装硅太阳能电池组件的EVA,主要根据透光性能和耐侯性能进行选择。 EVA具有优良的柔韧性,耐冲击性,弹性,光学透明性,低温绕曲性,黏着性,耐环境应力开裂性,耐侯性,耐化学药品性,热密封性。

门禁系统安装规范及调试要点

门禁设备安装规范及系统调试要点
RS485 联网通讯 门禁系统示意图


第一章 门禁设备的安装与系统调试步骤 ........................................................................................................... 2
门禁设备的安装 .........................................................................................................................................................................2
第二章 选用线材及工程布线 ............................................................................................................................... 3
第 2.1 节 布线接线注意事项 .................................................................................................................................................3 第 2.2 节 网线选用及布线技巧--RS485 联网门禁...............................................................................................................3 第 2.3 节 网线选用及布线技巧—TCP/IP 网络门禁.............................................................................................................5 第 2.4 节 门禁控制单元---线材选用及布线技巧................................................................................................................6
第三章 门禁设备的安装与接线 ........................................................................................................................... 8
第 3.1 节 门禁控制器的安装 .................................................................................................................................................9 第 3.2 节 读卡器的安装与连接 .............................................................................................................................................9 第 3.3 节 电锁及锁电源的安装与连接 ...............................................................................................................................10 第 3.4 节 出门按钮的安装与连接 .......................................................................................................................................12 第 3.5 节 消防联动、门磁、红外、声光报警器的安装与连接........................................................................................12
第四章 门禁系统调试中的常见问题 ................................................................................................................. 12
第 5.1 节 门禁系统 RS485 总线通讯方面的问题................................................................................................................12 第 5.2 节 门禁系统 TCP/IP 网络通讯方面的问题..............................................................................................................13 第 5.3 节 开不了门(电锁不动作)的问题 .......................................................................................................................13

门禁系统安装施工工艺及方法

门禁系统安装施工工艺及方法 一、门禁系统安装要求 所使用设备材料应根据合同文件及设计要求选型,对设备、材料与软件进行进场验收,并填写验收记录。 设备应有产品合格证、质检报告、“CCC”认证标识、安装及使用说明书等。 如果就是进口产品,则需提供原产地证明与商检证明,配套提供得质量合格证明,检测报告及安装、使用、维护说明书得中文文本。 设备安装前,应根据使用说明书,进行全部检查,方可安装。 施工机具: 手电钻、冲击钻、对讲机、梯子、电工组合工具、250V兆欧表、500V兆欧表、水平尺、钢尺、小线等。 作业条件: 机房装修已完毕,门、窗、门锁装配齐全。 线缆沟、槽、管、箱、盒施工完毕。 技术准备: 施工图纸齐全,施工方案编制完毕并经审批。 施工前应组织施工人员熟悉图纸、方案及专业设计安装使用说明书,并进行有氏对性得培训及安全、技术交底。 二、安装工艺及方法

(一)操作工艺 工艺流程: 管路敷设→设备箱安装→线缆敷设→终端设备安装→设备接线、调试 (二)施工方法 一、管路敷设 1、钢管敷设: 敷设前先检查管内侧有无毛刺,镀锌层或防锈漆就是否完整无损,管子不顺直应调直。 1、1暗敷设 a、砌墙立管:钢管宜置于墙中心,然后按标高将接线盒稳好。 b、混凝土墙、板配管:可将盒、箱焊在钢筋上,敷管时每隔1m用铅丝绑扎固定。 1、2明敷设 a、敷管时,先将管卡一端得螺钉拧进一半,然后将管敷设在管卡内,逐个将螺钉拧牢。使用铁支架时,可将钢管固定在支架上,不得将管焊接在其她管道上。 b、水平或垂直敷设时配管得允许偏差值:管路在2m以内时,偏差为3mm,全长不应超过管子内径得1/2。 1、3室处管路敷设 a、室外埋地敷设得电缆导管,壁厚应大于2mm,埋深不应小于0、8m。 b、室外导管得管口应设置在盒、箱内。所有管口穿入线缆后应做密封处理。 1、4管路连接

家具安装方法

家具是我们生活中必不可少的东西,它为我们带来方便和实用的同时,也美化着我们的家。但对于新买回来的家具您了解家具安装技巧吗?下面就给大家简单介绍一下家具安装的方法。 一、家具安装前 1、工具的准备 好的家具,不仅仅让我们在使用中可以感受到,而且能让我们在家具安装的时候体会到其中独特的乐趣。就像玩模型一样,一步步,匠心独运。然而,家具安装可跟玩模型有很大的区别。首先,我们需要为安装准备必要的安装工具,常见的家具安装需要用到十字、一字螺丝刀各一个,开口扳手,卷尺,铁钳,胶锤等。兵马未动,粮草先行。先准备好安装的工具,是家具安装的必要环节。 2、场地的选择 为家具安装选择良好的环境,也对安装质量的影响起到了决定性的因素。地面不平,容易造成家具骨架倾斜、影响卷尺的尺度测量、家具各部件衔接发生间隙等,而环境的湿度也对家具安装有很大的影响,尤其是实木家具。环境湿度过大,比如阴雨天,容易在家具安装的时候,让水汽进入家具各部位的衔

接面、金属固定器件,让家具容易受到虫蛀,发生霉烂,金属器件也容易生锈。 二、家具安装中 1、安装时要注意家中的其它位置的保护,因为家具一般在家装过程中是最后进场(不装修的话更要保护家里的物品),重点保护的对象是:地板(尤其是实木地板)、门套、门、楼梯、墙纸、壁灯等。 2、如果是请师傅安装,要亲自跟进安装过程,看是否有安装过程中的损坏,其实这一点倒不会有太多的问题,因为安装工都是经验丰富的,如果他弄坏了您的家具,公司也会有一定的处罚。如果是自己安装,一定要注意做好自身安全防护,地面也要有柔软的材料防护,以免造成划伤,刮花。 3、拉手、把手等五金件的安装:这里主要是要确定安装位置,以最合适家人的高度或者位置就可以,而不要光图美观好看。比如吊柜或者增高柜的把手一定要安装在门的下面,地柜、写字台的小柜,一定要放在上面。 4、注意保持卫生:如果您是更换家里的旧家具,这一点尤为重要(新装修的朋友还可以做整体保洁),因为定制家具不同于成品家具,很多东西是在您的家中安装完成的,必然要有一些打孔、切割等工作,所以必然会有一些锯末和灰尘产生。 5、墙面中的装修管线:水电改造已经是现代装修中必不可少的一项,所以墙面中,顶棚中,顶与墙的交接处都会有管线埋于墙内的可能。为什么要提到这一点?因为定制家具的安装其实与整体橱柜非常像,也有吊柜,

油浸电力变压器的构造讲解

油浸式电力变压器 一、油浸式电力变压器的结构 器身:铁心、绕组、绝缘结构、引线、分接开关 油箱:油箱本体、箱盖、箱壁、箱底、绝缘油、附件、放油阀门、油样活门、接 地螺栓、铭牌 冷却装置:散热器和冷却器 保护装置:储油柜油枕、油位表、防爆管安全气道、吸湿器( 呼吸器) 、温度计、净油器、气体继电器瓦斯继电器 出线装置:高压套管、低压套管 1 、铁芯 铁芯在电力变压器中是重要的组成部件之一。它由高导磁的硅钢片叠积和钢夹夹紧而成铁心具有两个方面的功能。 在原理上:铁心是构成变压器的磁路。它把一次电路的电能转化为磁能又把该磁 能转化为二次电路的电能,因此,铁心是能量传递的媒介体。 在结构上:它是构成变压器的骨架。在它的铁心柱上套上带有绝缘的线圈,并且牢固地对它们支撑和压紧。铁心必须一点接地。 2、绕组 绕组是变压器最基本的组成部分,绕组采用铜导线绕制,它与铁心合称电力变压器本体,是建立磁场和传输电能的电路部分。电力变压器绕组由高压绕组、低压绕组,高压引线低压引线等构成。 3、调压装置 变压器调压是在变压器的某一绕组上设置分接头,当变换分接头时就减少或增加了一部分线匝,使带有分接头的变压器绕组的匝数减少或增加,其他绕组的匝数没有改变,从而改变了变压器绕组的匝数比。绕组的匝数比改变了,电压比也相应改变,输出电压就改变,这样就达到了调整电压的目的。 ⑴有载分接开关:有载分接开关的额定电流必须和变压器额定电流相配合。切换开关需要定期检查,检查时应易于拆卸而不损坏变压器油的密封。开关仅应在 运行 5~6年之后或动作了 5 万次之后才需要检查。 ⑵无励磁分接开关:无励磁分接开关应能在停电情况下方便地进行分接位 置切换。无励磁分接开关应能在不吊芯(盖)的情况下方便地进行维护和检修, 还应带有外部的操动机构用于手动操作。 4、油箱 电压等级高的变压器油箱应装设压力释放装置,根据保护油箱和避免外部 穿越性短路电流引起误动的原则,确定合理的动作压力。 油箱顶部应带有斜坡,以便泄水和将气体积聚通向气体继电器。通向气体继电器 的管道应有 1.5%的坡度。气体继电器应装有防雨措施,并将采气管引至地面。 5、绝缘油: 绝缘油采用环烷基油,绝缘油应为IEC 规范IA 号油,其闪点不低于140℃。制造厂除供应满足变压器标准油面线的油量( 含首次安装损耗 ) 以外,另加10%

门禁主机说明书

使 用 手 册 安装使用前请仔细阅读本说明书

目录 一、引言 二、产品外观 三、系统功能 四、主要参数 五、安装接线 六、故障检修 七、原装附件 八、软件安装 九、门禁软件 十、考勤软件

一、 引言: 感谢您使用本网络(联网)型门禁系统,在使用本系统之前,请您详细阅读本使用手册,并严格按照手册中的要求来操作。此手册将介绍本系统主要功能及操作使用方法。 本门禁系统采用目前世界上先进的技术-非接触式感应卡技术(也称射频识别卡(RFID)技术,RFID卡具有全球卡号唯一、不易仿制的读写特性和安全性能。RFID卡片不会产生使用磁卡时因磁头磨损、磁粉脱落、灰尘等影响所带来的麻烦,而且避免了接触式IC卡因芯片与读卡器外露而引起的沾污、接触不良和外物损伤而导致的读卡不良现象,RFID卡适应各种环境,经久耐用。 每一次感应卡读的信息,无论是否向电锁发出开锁指令,系统都自动记录下来,管理者可以通过计算机下载调阅门禁控制系统存储的信息资料,轻松查阅、打印所有的通行事件。管理软件将根据此原始资料自动统计员工考勤情况、编制考勤报表;还可提供在线式巡更系统! 本系统提供了一种智能化的出入口控制、考勤管理及在线式巡更,适用于需要控制人员出入的通道、智能化生活小区、商务机构、政府机关以及考勤管理人员较多的企事业单位。

二、产品外观: 1、主机及门控器外形图

2、主机指示灯 三、系统功能: 1、名词解释: 事件记录:是指每一次控制器发生动作时所有的记录,包括事件发生时间、地点、人员、事件类型 事件类型:主要包括用户读卡进门、读卡出门、主用户卡读卡进门、主用户卡读卡出门、非法卡、按钮开门、报警、密码开门、禁行时段不开、节假日管制不开、管理时段不开、反潜回不开、反尾随不开、紧急时段不开。 卡类型:包括主用户卡、胁迫卡、管理卡、用户卡、访客卡。主用户卡是指不受通行时段、管理时段、节假日、反潜回控制的卡;胁迫卡是指拥有主用卡的功能,但在读卡时会启动输出报警信号;用户卡是指可根据需要设置禁行时段、节假日管制、管理卡首开时段等控制手段;管理卡是指权限和用户卡一样,但是管理卡首开时段必须先读此类卡后其他用户卡才有效;访客卡权限和用户一样,但是多了一个时效限制。 常开时段:是指所设时段内电锁一直处于开启状态。 禁行时段:是指所设时段内受管制的管理卡、用户卡、访客卡不能读卡开锁。

35kV 油浸变压器使用说明

OZB.469.504 安装使用说明书 -35kV级油浸式变压器 中电电气集团 江苏中电输配电设备有限公司

目录 35kV级油浸式变压器安装使用说明书 1.适用范围 (1) 2.变压器结构简介 (1) 3.运输 (2) 4.验收 (2) 5.存放 (2) 6.安装变压器 (2) 7.变压器投入运行 (5) 8.变压器投入运行后的注意事项 (5) 附录组件使用说明 A.压力释放阀 (6) B.分接开关 (8) C.套管 (14) D.吸湿器 (15) E.温度控制器 (16) F.气体继电器型 (18) G.SYJ-50型速动油压继电器 (20) H.指针式油位计 (22)

35kV级油浸式变压器安装使用说明书 1适用范围 1.1本说明书适用于35kV级油浸式变压器。 1.2产品型号说明 S F S Z9-□/□ 高压绕组电压等级(kV) 额定容量(kVA) 性能水平代号 调压方式:有表示有载调压,无表示是无励磁调压 绕组数:有表示三绕组,无表示双绕组 冷却方式:有表示风冷,无表示自冷 三相变压器 2变压器结构简介 2.1铁心 铁心材料选用优质高磁导冷轧取向硅钢片,全斜,步进式三级接缝,无孔绑扎,板式夹件结构。 2.2线圈 线圈材料采用优质无氧铜材料制造的圆铜线或扁铜线,低压线圈采用连续式或螺旋式结构;高压线圈采用连续式或多层圆筒式,不浸漆,但经过干燥处理形成一个有机整体。 2.3器身绝缘 铁心窗口内线圈上端增设30mm整体层压木压圈及30mm分体附压板,下端增设70mm整体层压木托板,不但加强了主绝缘强度,而且提高了线圈轴向的动稳定性。 2.4引线 高压引线,有载调压时采用优质的有载调压分接开关,无励磁调压小电流时采用无励磁调压分接开关,大电流时采用三只单相无励磁分接开关。 2.5油箱 ≤6300kVA变压器采用桶式油箱和固定式片式散热器,≥8000kVA变压器采用钟罩式油箱和可拆卸式片式散热器。 2.6总装配 压力释放阀开启式变压器容量≥315kVA安装压力释放阀(见附录A)。 温度控制器变压器容量≥1000kVA安装温度控制器(见附录E)。 气体继电器变压器容量≥800kVA安装气体继电器(见附录F)。 速动油压继电器变压器容量≥8000kVA安装速动油压继电器(见附录G)。

单双门禁系统安装方法

单门、双门、四门系列门禁安装及说明 门禁系统分为两种类型,总线和网络型。总线型分单门、双门、四门等门禁控制器通过485总线方式直接接入门禁服务器串口,前端按钮、电磁锁(电插锁)、读卡器、门磁接入门禁控制器。网络型分两种方式:1、单门、双门等网络门禁控制器通过网络接入门禁服务器,2、前端按钮、电磁锁(电插锁)、读卡器、门磁先接入门禁控制器然后接入网络门禁控制器,通过网络接入门禁服务器,门禁控制器可接入门的数量及网络门禁控制器可接入门禁控制器的个数根据现场情况而定。下面介绍门磁、各种锁、按钮、读卡器、防爆门禁、门禁控制器的介绍及安装方法,因门禁的厂家较多,赞只找了一些有代表性的产品,和其他门禁原理相同。 一、门磁 1).门磁的功能和原理,门磁在门禁系统中的应用。 门磁是用来检测门是否关闭的一个小型感应器,有很多电锁是带了门磁功能的,建议客户如果门禁系统中用到门磁,最好是采购带门磁功能(门状态反馈功能)的电锁。如果电锁没有带门磁功能,可以自行选购门磁,门磁大小比一元硬币略大,价格在十几块钱左右。 市面上常见的一款暗装式门磁,不带电线的一端内藏磁铁,带电线的低端内部藏有干簧管等元器件,当磁铁接近时,电线输出闭合信号,当磁铁远离时,两条电线输出开路信号。不带电线的一端装在门的顶部,带电线的一端装在门框上。门关好时,两端正好重叠接近。市面上还有一些门磁是方形的,适用于明装场合,用于门窗上。 2).门磁在门禁系统中的主要作用在于以下几点: 在软件实时监控时,可以看到每个门现在的状态是开着的还是关着的。 可以配合门禁控制器启用门被非法闯入(没有刷卡或者按按钮的合法操作,而门被打开了,例如踹开或者撬开)报警。 可以配合门禁控制器启用门长时间未关闭报警。 备注:如果不需要这几个功能的门禁系统,可以不接门磁。如果需要这几个功能,就将门磁接到控制器的门磁输入点(例如Sen1 GND)上,不用区分正负。如果一个大型多门门禁系统,只有几个门用到门磁的这几个功能,则其他的门磁输入点(例如Sen1 GND)用导线进行短接,避免产生误报警信号 二、电磁锁 目前,门禁控制器控制门开、闭的主要执行机构是各类电锁,包括锁扣、磁力锁、电插锁等,锁扣、磁力锁多用于木门,而电插锁多用于玻璃门,一般锁具是采用直流方式供电,供电电压从12V到18V甚至24V不等,因此功耗也各不相同,出于节能的考虑,门锁要根据具体需要进行合理选择:在重要场合,门锁要经得住一定的外界冲击破坏,因此可以选用大功率的电锁,而一般性的场合,如果要求不高,可以采用12V供电的电锁。就目前具体使用情况来看,绝大多数电锁是采用工作电压为12V,待机状态电流消耗小于1A的小功率电锁。 以下为门锁安装步骤及示意图: 1).双开门(电插锁ML150-6 )

板式家具安装及验收标准

板式家具安装及验收标准 目录 一、安装工作制度二、安装人员守则三、安装操作步骤 1、现场清理 2、货品分类 3、操作步骤四、现场操作指引 1、标准柜的安装 2、轻轨门的安装 3、有掩门的顶柜安装五、安装验收标准 1、门板验收标准 2、收口验收标准 3、柜体验收标准 4、配件验收标准 5、清洁验收标准 六、安装工具使用 1、工具名称 2、工具用途 3、工具维护保养注意事项 一、安装人员工作制度 1、安装人员的个人言行必须遵守《安装人员守则》准则。 2、后安装工作人员必须具备到位的市场服务意识,对待产品安装质量和货期,自身必须要做到严格的控制和把关。定制家具,家具定制 3、每日根据主管下达的安装任务,充分做好货品的清点以及安装工具的准备工作,避免出现到达现场后因遗漏而影响了工作的开展。 4、对于当天安装的订单图纸,应提前熟悉,做到根据图纸结构对照安装细节的分析工作,对可能出现的现场问题应有预备解决方案。整体家具网 5、送货安装的出车时间要保证,尽量做到宜早不宜迟,并且要遵照与客户预约的时间之前到达安装现场。

6、每日正常的衣柜及其它家具订单安装,必须在当天内安装完工,除因设计问题或客户问题外,不得以任何借口或理由拖延安装完工的时间。 7、安装过程中,如果有出现因产品质量或生产问题造成的安装工作受阻,必须及时与售后主管人员联络,以寻求最快解决问题的办法。 8、因设计出错而导致现场安装受阻时,应在第一时间通知有关设计人员到达现场解决问题,并且及时反映给售后主管以便合理安排工期。 9、当客户有问题提出修改意见,要有礼貌和耐心,首先应通过专业的知识进行讲解,涉及到产品修改时,必须要有客户或设计人员确认。 10、回答客户问题时,要注意表达的方式和策略,不能因个人言语不慎而造成对公司利益的损失或对品牌的影响。 11、如果因设计或客户自身问题导致安装不能当天完工,临走前必须明确承诺给客户再次上门服务的时间,并且由原安装人员跟进。定制家具,家具定制 12、安装过程中因自身造成的质量问题或进度问题,必须如实报告给售后主管以寻求最佳解决办法,不得做任何隐瞒或违规私自处理。二、安装人员守册 1、上班时不准穿拖鞋,不准留胡须长发,要统一着工作装,做到衣着整洁干净;并且言语礼貌,行为文明。 2、安装人员须具独立看图和安装的工作能力,具备现场技术问题处理能力。当天安装或维修的工作必须当天完成,特殊情况上报主管部门裁定。整体家具网 3、妥善保管领用的安装工具,每次去现场安装之前,应提前一晚检查自己的工具是否遗失或损坏,充电工具电池是否充足电源。以确保第二天的工作能够顺利完成。属个人原因造成工作拖延,后果自负并按情节处理。 4、如果跟随送货车前往安装现场,装车时应留意包装物件的堆放,作好物件在运输过程中的保护工作,以保证产品完好无缺的到达安装现场。定制家具,家具定制

门禁集系统施工方案

第1章 各子系统施工方法及工艺 1.1 门禁集中控制系统 1.1.1 系统组成 由门禁控制器、读卡器、磁力锁、出门按钮组成。 1.1.2 系统实施方案 系统设置一台管理主机,放置在监控中心;在管理主机上安装门禁管理软件,负责对整个门禁系统的维护管理;控制器为系统的核心部件,负责整个系统输入、输出信息的处理和储存、控制等。为方便现场施工和日常维护,所有管线均设置于PVC 穿线管当中,系统做好防雷接地。 门控点设备安装示意图如下: 读卡器(电锁线 门磁线 出门按钮线 读卡器线 (穿PVC管) 至门禁控制器 单扇门设备安装示意

读卡器( 至门禁控制器(穿PVC管)出门按钮线 门磁线 电锁线 双扇门设备(磁力锁)安装示意 ●电磁门锁可以水平或垂直安装在门框上,电磁门锁及电线应安装在室内以确保 安全; ●电磁锁与吸附板应对正安装,以达到吸附力最大; ●吸附板必须加橡胶垫片进行微调; ●电控门锁的电源装置应安装在控制中心或门附近的吊顶内; ●出门按钮应安装在操作舒适无障碍物的位置; 1.1.3施工流程 根据招标文件的需求分析,结合我公司施工经验,门禁集中控制系统的施工工艺流程按照:穿管布线,连接设备,线路测试,系统整体测试的流程依次进行。 1.1.3.1 器材检查 对所用器材进行外观检验,检查其型号规格、数量、标志、标签、产品合格证、产品技术文件资料,有关器材的电气性能、机械性能、使用功能及有关特殊要求负荷施工相关要求。 1.1.3.2 管路敷设 根据招标需求,首先进行线管的敷设。线管敷设方面达到如下要求: ●预埋在墙体中间的暗管内径不宜超过50mm;

●楼板中的暗管内径宜为15~25mm; ●直线布管30m处应设置拉线盒或接线箱; ●暗配管制转弯角度应大于90°,在路径上每根暗管的转弯角度不得多于二个, 并不应有S弯出现; ●在弯曲布管时每间隔15m处,应设置暗拉线盒或接线箱; ●暗配管转弯的弯曲半径不应小于该管外径的6倍,如暗管外径大于50mm时, 不应小于10倍。 1.1.3.3 刷卡机安装 ●安装在台面或者墙面上,前面安装距离地面100cm,应严密防水、防尘; ●刷卡机的固定方法以施工现场条件而定; ●固定螺丝需拧紧,不应产生松动现象; ●安装位置应符合设计要求。 1.1.3.4 接地 安装机柜,配线设备及金属钢管、槽道、接地体,保护接地导线截面、颜色应符合设计要求,并保持良好的电气连接,压接处牢固可靠。 1.1.4施工工艺 ●设备安装:必须按照设备随机提供的设备安装工艺要求和说明书的要求进行操 作,设备必须安装稳固; ●安装应牢靠,不得倾斜,严格按照设备机架安装标准进行安装; ●设备安装应美观,注意防水防尘; ●设备必须严格接地。 1.2 停车场管理系统 1.2.1系统组成 本系统主要由集成道闸、入口发卡机、出口收费机、停车场专用网络摄像机、管理软件等组成。

相关主题