Main functions of Basic ATS:

Switch over: automatic switch over power A and power B,

interval time 10≤16ms.

Monitoring: total load current;

input/output voltage; power supply A/B; system operating state.

User-defined alarm: threshold of total load current.System default alarm: current overload;

either power supply goes wrong.

Alarm method: audible and visual alarm

(external connection).

Accessing method: SERIAL.

All rights reserved. Contents are subject to change without prior notice.

IEC320 C20

IEC320 C19

IN

T2X33232AB

OUT

IEC60309IEC320 C19

IN

T2X35232AB

OUT

IEC60309

IEC60309

IN T2X36232AB

IEC60309IEC60309

OUT

IEC60309

IN

T2X31232AB

IN

T2S24216AB

IEC60309OUT

IEC60309

IN

T2S12216AB

OUT

IN

T2S20216AB

IEC60309

IN

T2S10216AB

IEC320 C20

T2S00216AB

A T S

AUTOMATIC TRANSFER SWITCH

The pictures are for indication only, subject to the final product.

Main functions of intelligent ATS:

Switch over: automatic switch over power A and power B,

interval time 10≤16ms.

Monitoring: total load current;

input/output voltage; power supply A/B; system operating state.

Remote control: switch over power A and power B;

threshold of total load current.

User-defined alarm: threshold of total load current.System default alarm: current overload;

when automatic transfer happens; either power supply goes wrong.

Alarm method: audible and visual alarm (external connection);

telephone alarm; email alarm.

Log record: save the system operation and alarm record which can be

inquired and exported.

System support: single user operating system, support software https://www.sodocs.net/doc/cb10521912.html,er management: set user's right.

Accessing method: Web, accessing through IE;

SNMP (V1/V2/V3), through standard network working station;

Telnet, SSH, through command-line console; SERIAL.

System configuration: time setting;

button lock;

voltage range setting;

transfer time from secondary power supply to main power supply;

system hyperlink.