搜档网
当前位置:搜档网 › 212 SEPIGEL 305 EN

212 SEPIGEL 305 EN

212 SEPIGEL 305 EN
212 SEPIGEL 305 EN

1.1 Product identifier 1.3 Details of the supplier of the safety data sheet 1.2 Relevant identified uses of the substance or mixture and uses advised against 1.4 Emergency telephone number National advisory body/Poison Centre Supplier

Not applicable.

Complying with 1907/2006/EC, 1272/2008/EC and 453/2010/EC regulations - United Kingdom (UK)

SAFETY DATA SHEET

SEPIGEL 305

Product trade name SEPIGEL 305:Material uses

:Cosmetics.

37667S Product code :Supplier

e-mail address of person responsible for this SDS

:SEPPIC S.A.

22 Terrasse Bellini - Paris La Défense 92806 Puteaux CEDEX - France Phone: +33(0)1 42 91 40 00 Fax: +33 (0)01 42 91 41 41

:MSDSinfo.SEPPIC@https://www.sodocs.net/doc/0f4800652.html,

Emergency telephone number (with hours of operation)

:SEPIPROD.

Tél.: +33 (0)5 63 72 69 69

Emergency telephone number (with hours of operation):UNITED KINGDOM :

999

Classification Xi; R36/38::Human health hazards

Irritating to eyes and skin.

See Section 11 for more detailed information on health effects and symptoms.Classification according to Regulation (EC) No. 1272/2008 [CLP/GHS]2.1 Classification of the substance or mixture

See Section 16 for the full text of the R phrases or H statements declared above.Classification according to Directive 1999/45/EC [DPD]

The product is classified as dangerous according to Directive 1999/45/EC and its amendments.2.2 Label elements Hazard pictograms

:

Signal word :Hazard statements :Prevention

:Precautionary statements Warning

Causes serious eye irritation. Causes skin irritation.

Skin Irrit. 2, H315Eye Irrit. 2, H319

Wear suitable gloves. Wear eye or face protection. Wash hands thoroughly after handling.

:Other hazards which do not result in classification None known.

medical attention. IF IN EYES: Rinse cautiously with water for several minutes.Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical attention.

2.3 Other hazards

Contains :3,6,9,12,15,18,21-heptaoxatritriacontanol

ADDITIONAL INFORMATION Handling :STIR BEFORE USE.

Storage

:

STORE AWAY FROM LIGHT AND HEAT (0-30°C)

Substance/mixture Mixture

Occupational exposure limits, if available, are listed in Section 8.

:

There are no additional ingredients present which, within the current knowledge of the supplier and in the

concentrations applicable, are classified as hazardous to health or the environment, are PBTs or vPvBs or have been assigned a workplace exposure limit and hence require reporting in this section.

[1] Substance classified with a health or environmental hazard [2] Substance with a workplace exposure limit

[3] Substance meets the criteria for PBT according to Regulation (EC) No. 1907/2006, Annex XIII [4] Substance meets the criteria for vPvB according to Regulation (EC) No. 1907/2006, Annex XIII [5] Substance of equivalent concern

Type

INCI Name:

:POLYACRYLAMIDE & C13-14 ISOPARAFFIN & LAURETH-7

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

4.1 Description of first aid measures Remove victim to fresh air and keep at rest in a position comfortable for breathing.If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In case of inhalation of

decomposition products in a fire, symptoms may be delayed. The exposed person Inhalation

Eye contact

::

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been

swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs,the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Notes to physician In case of inhalation of decomposition products in a fire, symptoms may be delayed.The exposed person may need to be kept under medical surveillance for 48 hours.Ingestion

:::Specific treatments

Protection of first-aiders

:No action shall be taken involving any personal risk or without suitable training. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation.

4.2 Most important symptoms and effects, both acute and delayed Potential acute health effects Inhalation :Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure.Irritating to mouth, throat and stomach.:Ingestion Skin contact :Causes skin irritation.

:Eye contact Over-exposure signs/symptoms

Skin contact

Ingestion

Inhalation No specific data.

No specific data.

Adverse symptoms may include the following:irritation redness

:::Eye contact

:Adverse symptoms may include the following:pain or irritation watering redness

4.3 Indication of any immediate medical attention and special treatment needed

No specific treatment.

:Hazardous thermal

decomposition products

Hazards from the substance or mixture Decomposition products may include the following materials:carbon dioxide carbon monoxide nitrogen oxides sulfur oxides

metal oxide/oxides

In a fire or if heated, a pressure increase will occur and the container may https://www.sodocs.net/doc/0f4800652.html,e an extinguishing agent suitable for the surrounding fire.5.1 Extinguishing media ::None known.

Suitable extinguishing media

:Unsuitable extinguishing media

:5.2 Special hazards arising from the substance or mixture

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves)conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

Special protective

equipment for fire-fighters

:Special protective actions

for fire-fighters

:6.2 Environmental precautions

Stop leak if without risk. Move containers from spill area. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows.Contain and collect spillage with non-combustible, absorbent material e.g. sand,earth, vermiculite or diatomaceous earth and place in container for disposal

according to local regulations. Dispose of via a licensed waste disposal contractor.Contaminated absorbent material may pose the same hazard as the spilt product.Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Large spill

:Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Small spill

:6.3 Methods and materials for containment and cleaning up 6.1 Personal precautions, protective equipment and emergency procedures For non-emergency personnel

:For emergency responders :6.4 Reference to other sections

See Section 1 for emergency contact information.

See Section 8 for information on appropriate personal protective equipment.See Section 13 for additional waste treatment information.

No action shall be taken involving any personal risk or without suitable training.Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Avoid breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

If specialised clothing is required to deal with the spillage, take note of any

information in Section 8 on suitable and unsuitable materials. See also the information in "For non-emergency personnel".

::7.1 Precautions for safe handling Protective measures

:Advice on general occupational hygiene

:Put on appropriate personal protective equipment (see Section 8). Do not ingest.Avoid contact with eyes, skin and clothing. Avoid breathing vapour or mist. Keep in the original container or an approved alternative made from a compatible material,kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.STIR BEFORE USE.

from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled https://www.sodocs.net/doc/0f4800652.html,e appropriate containment to avoid environmental contamination.storage, including any incompatibilities

7.3 Specific end use(s)Recommendations ::Industrial sector specific solutions

Not available.

Not available.STORE AWAY FROM LIGHT AND HEAT (0-30°C)

Recommended monitoring procedures

Occupational exposure limits If this product contains ingredients with exposure limits, personal, workplace

atmosphere or biological monitoring may be required to determine the effectiveness of the ventilation or other control measures and/or the necessity to use respiratory protective equipment. Reference should be made to monitoring standards, such as the following: European Standard EN 689 (Workplace atmospheres - Guidance for the assessment of exposure by inhalation to chemical agents for comparison with limit values and measurement strategy) European Standard EN 14042 (Workplace atmospheres - Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents) European Standard EN 482

(Workplace atmospheres - General requirements for the performance of procedures for the measurement of chemical agents) Reference to national guidance

documents for methods for the determination of hazardous substances will also be required.

Hand protection

Chemical-resistant, impervious gloves complying with an approved standard

should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists,gases or dusts. If contact is possible, the following protection should be worn,unless the assessment indicates a higher degree of protection: chemical splash goggles.

Eye/face protection

:::No exposure limit value known.

Appropriate engineering controls

:No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. If this product contains

ingredients with exposure limits, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure below any recommended or statutory limits.

Wash hands, forearms and face thoroughly after handling chemical products,

before eating, smoking and using the lavatory and at the end of the working period.Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.

8.2 Exposure controls Hygiene measures :No DNELs/DMELs available.PNECs

No PNECs available 8.1 Control parameters DNELs/DMELs

Individual protection measures Recommended :fluor rubber. nitrile rubber

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection

must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Respiratory protection

:being performed and the risks involved and should be approved by a specialist before handling this product.

:Environmental exposure controls

:Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation.In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Other skin protection

Appropriate footwear and any additional skin protection measures should be

selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Physical state Liquid. [Emulsion. Fluid.]

pH

Translucent to Opaque , White to yellowish.Colour Flash point

Closed cup: >102,5°C [ABEL / IP170 / 190.]5,5 to 7,5 [Conc. (% w/w): 2%]

Viscosity

Dynamic: 1500 to 4500 mPa·s :::::9.1 Information on basic physical and chemical properties Appearance 9.2 Other information

Flammability of the product :None available.

Dispersible in the following materials: cold water.:

Solubility Temperature of viscosity measurement::25 °C

The information presented in this section does not serve as specifications.

10.6 Hazardous

decomposition products

10.4 Conditions to avoid No specific data.Under normal conditions of storage and use, hazardous decomposition products should not be produced.

The product is stable.

10.2 Chemical stability No specific data.

:::10.5 Incompatible materials :10.3 Possibility of hazardous reactions

:Under normal conditions of storage and use, hazardous reactions will not occur.

10.1 Reactivity :No specific test data related to reactivity available for this product or its ingredients.Acute toxicity

Irritation/Corrosion 11.1 Information on toxicological effects Conclusion/Summary :Not classified as dangerous Conclusion/Summary :

Skin

:Irritating to skin.

Potential chronic health effects No known significant effects or critical hazards.General :No known significant effects or critical hazards.Carcinogenicity :No known significant effects or critical hazards.Mutagenicity :No known significant effects or critical hazards.Teratogenicity :Carcinogenicity

Teratogenicity

Reproductive toxicity Developmental effects :No known significant effects or critical hazards.Fertility effects :No known significant effects or critical hazards.Sensitisation

Delayed and immediate effects and also chronic effects from short and long term exposure Short term exposure Long term exposure

Other information

:Not available.

Eyes :Irritating to eyes.

Conclusion/Summary :

Skin :Non-sensitiser to skin.Conclusion/Summary :

Not mutagenic in Ames test.

Conclusion/Summary :Not available.Conclusion/Summary :Not available.Conclusion/Summary :Not available.

Chronic toxicity Conclusion/Summary :Not available.

Specific target organ toxicity (single exposure)

Not available.

Specific target organ toxicity (repeated exposure)Not available.12.1 Toxicity 12.2 Persistence and degradability Conclusion/Summary :No known significant effects or critical hazards. ( Literature )

Conclusion/Summary

:Not readily biodegradable. Bioaccumulative potential low . ( Literature )

12.3 Bioaccumulative potential 12.6 Other adverse effects

No known significant effects or critical hazards.

Not available.PBT :Not applicable.vPvB

:Not applicable.

12.4 Mobility in soil Soil/water partition coefficient (K OC )

Not available.

:

12.5 Results of PBT and vPvB assessment :The generation of waste should be avoided or minimised wherever possible.

Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

:Methods of disposal

13.1 Waste treatment methods Product

Packaging

Methods of disposal

:Special precautions

:The generation of waste should be avoided or minimised wherever possible.Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible.

This material and its container must be disposed of in a safe way. Care should be taken when handling emptied containers that have not been cleaned or rinsed out.Empty containers or liners may retain some product residues. Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Hazardous waste :Within the present knowledge of the supplier, this product is not regarded as hazardous waste, as defined by EU Directive 91/689/EEC.

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

:Not available.

Other EU regulations Not applicable.Annex XVII - Restrictions on the manufacture,placing on the market and use of certain

dangerous substances,mixtures and articles :Europe inventory

:Not determined.Chemical Weapons

Convention List Schedule I Chemicals

:Not listed

Chemical Weapons

Convention List Schedule II Chemicals

:Not listed

Chemical Weapons Convention List Schedule III Chemicals

:Not listed 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture EU Regulation (EC) No. 1907/2006 (REACH)

Annex XIV - List of substances subject to authorisation 15.2 Chemical Safety Assessment This product contains substances for which Chemical Safety Assessments are still required.

:Annex XIV

Substances of very high concern

None of the components are listed.

None of the components are listed.

21/05/2013.

Date of printing Date of issue/ Date of revision

Version

The information contained in this document is provided as a guideline; it is based on the extent of SEPPIC’s knowledge regarding the product on the date indicated above. It applies to the product as is, in conformity with the specifications provided by SEPPIC*.

Should the product undergo chemical transformation or be combined or mixed with other substances, it is the sole responsibility of the user to ensure that no new danger appear. Given that the use of this information is beyond the control of SEPPIC*, SEPPIC* provides no warranty, whether express or implied, and assumes no responsibility, regarding the use of this information and of the user’s product.

SEPPIC* being SEPPIC SA and its subsidiaries (addresses available on https://www.sodocs.net/doc/0f4800652.html, )

Notice to reader

Date of previous issue ::::R22- Harmful if swallowed.

R65- Harmful: may cause lung damage if swallowed.R41- Risk of serious damage to eyes.R36/38- Irritating to eyes and skin.

R66- Repeated exposure may cause skin dryness or cracking.:Full text of abbreviated R phrases

Xn - Harmful Xi - Irritant :Full text of classifications [DSD/DPD]21/05/2013.21/05/2013.4

Full text of abbreviated H statements

:acronyms

CLP = Classification, Labelling and Packaging Regulation [Regulation (EC) No.1272/2008]

DNEL = Derived No Effect Level

EUH statement = CLP-specific Hazard statement PNEC = Predicted No Effect Concentration RRN = REACH Registration Number

Full text of classifications [CLP/GHS]

:H302Harmful if swallowed.H304May be fatal if swallowed and enters airways.H315Causes skin irritation.H318Causes serious eye damage.H319Causes serious eye irritation.Acute Tox. 4, H302ACUTE TOXICITY: ORAL - Category 4Asp. Tox. 1, H304ASPIRATION HAZARD - Category 1Eye Dam. 1, H318SERIOUS EYE DAMAGE/ EYE IRRITATION - Category 1Eye Irrit. 2, H319SERIOUS EYE DAMAGE/ EYE IRRITATION - Category 2Skin Irrit. 2, H315SKIN CORROSION/IRRITATION - Category 2History

四大隐患不可不知 劣质排插存在的危害(新编版)

Safety issues are often overlooked and replaced by fluke, so you need to learn safety knowledge frequently to remind yourself of safety. (安全管理) 单位:___________________ 姓名:___________________ 日期:___________________ 四大隐患不可不知劣质排插存 在的危害(新编版)

四大隐患不可不知劣质排插存在的危害(新 编版) 导语:不安全事件带来的危害,人人都懂,但在日常生活或者工作中却往往被忽视,被麻痹,侥幸心理代替,往往要等到确实发生了事故,造成了损失,才会回过头来警醒,所以需要经常学习安全知识来提醒自己注意安全。 电,已经成为人们生活中必不可少的一种能源,而作为电力传送末端与各种电器之间不可或缺的桥梁,排插已经成为家家户户的必备品,然而在许多人心目中,从墙体插座到电器插头之间的这几米距离的安全性并没有被重视起来。许多人都觉得买个十几块钱的排插就算大功告成,其实目前市面上多数排插都存在着或多或少的安全隐患。 对于排插来说,其做工用料、安全设计以及其他的一些参数必须要符合国家的认证标准,从导线内部金属芯的粗细,到外壳的绝缘能力,几乎都有着严格的规定,就是为了能够让消费者在日常使用中获得更加安全的用电环境。但是对于消费者而言,在购买时往往价格都是最为主观的因素,只要价格便宜,看上去差不多就行了。毕竟几十元的和上百元的排插都是用来连接电器插头用的。 虽然从价格上来说,有着同样孔位的排插差价可能会有几十元甚至上百元,但是从做工用料到安全保障上却有着天差地壤的区别。今

国标行标地标企标的解释

行业标准,企业标准,国标.运用的字母国标 1 GB 中华人民共和国强制性国家标准国家标准化管理委员会 2 GB/T 中华人民共和国推荐性国家标准国家标准化管理委员会 3 GB/Z 中华人民共和国国家标准化指导性技术文件国家标准化管理委员会行 标 1 BB 包装中国包装工业总公司包改办 2 CB 船舶国防科工委中国船舶工业集团公司、中国船舶重工集团公司(船舶) 3 CH 测绘国家测绘局国土测绘司 4 CJ 城镇建设建设部标准定额司(城镇建设) 5 CY 新闻出版国家新闻出版总署印刷业管理司 6 DA 档案国家档案局政法司 7 DB 地震国家地震局震害防预司 8 DL 电力中国电力企业联合会标准化中心 9 DZ 地质矿产国土资源部国际合作与科技司(地质) 10 EJ 核工业国防科工委中国核工业总公司(核工业) 11 FZ 纺织中国纺织工业协会科技发展中心 12 GA 公共安全公安部科技司 13 GY 广播电影电视国家广播电影电视总局科技司 14 HB 航空国防科工委中国航空工业总公司(航空) 15 HG 化工中国石油和化学工业协会质量部(化工、石油化工、石油天然气)16 HJ 环境保护国家环境保护总局科技标准司 17 HS 海关海关总署政法司18 HY 海洋国家海洋局海洋环境保护司 19 JB 机械中国机械工业联合会 20 JC 建材中国建筑材料工业协会质量部 21 JG 建筑工业建设部(建筑工业) 22 JR 金融中国人民银行科技与支付司 23 JT 交通交通部科教司

24 JY 教育教育部基础教育司(教育) 25 LB 旅游国家旅游局质量规范与管理司 26 LD 劳动和劳动安全劳动和社会保障部劳动工资司(工资定额) 27 LY 林业国家林业局科技司 28 MH 民用航空中国民航管理局规划科技司 29 MT 煤炭中国煤炭工业协会 30 MZ 民政民政部人事教育司 31 NY 农业农业部市场与经济信息司(农业) 32 QB 轻工中国轻工业联合会 33 QC 汽车中国汽车工业协会 34 QJ 航天国防科工委中国航天工业总公司(航天) 35 QX 气象中国气象局检测网络司 36 SB 商业中国商业联合会 37 SC 水产农业部(水产) 38 SH 石油化工中国石油和化学工业协会质量部(化工、石油化工、石油天然气) 39 SJ 电子信息产业部科技司(电子) 40 SL 水利水利部科教司 41 SN 商检国家质量监督检验检疫总局 42 SY 石油天然气中国石油和化学工业协会质量部(化工、石油化工、石油天然气) 43 SY(>10000) 海洋石油天然气中国海洋石油总公司 44 TB 铁路运输铁道部科教司 45 TD 土地管理国土资源部(土地) 46 TY 体育国家体育总局体育经济司 47 WB 物资管理中国物资流通协会行业部 48 WH 文化文化部科教司 49 WJ 兵工民品国防科工委中国兵器工业总公司(兵器) 50 WM 外经贸对外经济贸易合作部科技司 51 WS 卫生卫生部卫生法制与监督司 52 XB 稀土国家计委稀土办公室 53 YB 黑色冶金中国钢铁工业协会科技环保部 54 YC 烟草国家烟草专卖局科教司

新国标的特别之处及选择方法

和旧国标相比,新国标有一个重要变化就是将市场中原有的定频空调与变频空调的两个标准合并成一个,不再区分定频和变频,只按照季节能效定级,也就是前面所说的EER和APF统一合并为APF。 “新国标”一共有5级标准,其中1级能效标准为全新制定,达到国际领先水平;2级和3级标准分别对应旧版变频1级和2级,4级则对应目前市场上部分变频3级和定频1级;5级对应目前市场上部分定频2级产品,也是新标准的准入级,曾经的定频3级被淘汰。 相关人士表示,新国标空调将更加节能省电,旧版标准中的变频1级能效空调,用掉1000瓦电可做出4500瓦功率的制冷(热)效果;而新国标的1级能效空调,用掉1000瓦电可做出5000瓦功率的制冷(热)效果。 将新标准空调和旧标准空调同时打开,在每天都打开的情况下,新国标空调比旧标准空调每年可省272度电,按照6毛一度电的价格,每年可省163.2元。表面上节约下来的能耗不太多,但放眼全国,节约下来的就是巨大的能耗了。 另外,新版国标淘汰了部分高能耗空调产品,那7月1日之后我们还能买到这些旧版标准的空调吗?答案是可以。虽然新版国标马上就要实施,但目前只规定厂家后续不准生产不符合新版国标的空调,而库存仍然可以继续销售到明年6月份。

省电仅仅是能效标准的一小部分 虽然能效标准几乎是围绕着省电来讲,但从我们前面的计算来看,对于个人家庭来说,不同等级的空调电费差距并不大。所以单纯追求省钱的话,买低等级的空调显然更合适,不仅不会多消耗太多电费,在购买空调上还能省个几百甚至几千。 不过,考虑到保护环境、节能减排的因素,1级能效空调的意义十分重大,全球数十亿家庭如果都能用上节能空调,必然会极大减轻地球负担。当然,这就看个人的觉悟了。 讲点实际的,即使你不在乎保护环境,1级变频空调仍然会比5级定频空调更值得购买。空调的节能性简单粗暴地说,是靠堆料来实现的,越节能的空调虽然越贵,但它的技术、用料、做工也更好,换句话也许能用得更久更省心。 另一方面,变频空调的舒适度远远好于定频空调,因为它的温度控制更加平稳精准,不会像定频空调那样频繁启停,导致温度反复波动。 因此,如果大家不差钱的话,肯定建议购买1级能效的变频空调。但毕竟每个人的使用习惯和消费能力不同,所以如果每天使用空调时间不多,在乎性价比,那么实惠的4级甚至5级定频空调也值得选择,并不会比1级变频费电太多,只是少了一些舒适性和环境保护方面的意义。

国家标准和行业标准有什么区别

国家标准和行业标准有什么区别对需要在全国范围内统一的技术要求,应当制定国家标准。国家标准由国务院标准化行政主管部门制定。对没有国家标准而又需要在全国某个行业范围内统一的技术要求,可以制定行业标准。行业标准由国务院有关行政主管部门制定,并报国务院标准化行政主管部门备案,在公布国家标准之后,该项行业标准即行废止。对没有国家标准和行业标准而又需要在省、自治区、直辖市范围内统一的工业产品的安全、卫生要求,可以制定地方标准。地方标准由省、自治区、直辖市标准化行政主管部门制定,并报国务院标准化行政主管部门和国务院有关行政主管部门备案,在公布国家标准或者行业标准之后,该项地方标准即行废止。 企业生产的产品没有国家标准和行业标准的,应当制定企业标准,作为组织生产的依据。企业的产品标准须报当地政府标准化行政主管部门和有关行政主管部门备案。已有国家标准或者行业标准的,国家鼓励企业制定严于国家标准或者行业标准的企业标准,在企业内部适用。 行标是行标,国标是国标,不一样的。 按照适用范围,我国的标准分为国家标准、行业标准、地方标准和企业标准四个级别。 (1)国家标准 由国务院标准化行政主管部门(现为国家质量技术监督检验检疫总局)指定(编制计划、组织起草、统一审批、编号、发布)。国家标准在全国范围内适用,其他各级别标准不得与国家标准相抵触。 (2)行业标准

由国务院有关行政主管部门制定。如化工行业标准(代号为HG)、石油化工行业标准(代号为SH)由国家石油和化学工业局制定,建材行业标准(代号为JC)由国家建筑材料工业局制定。行业标准在全国某个行业范围内适用。 (3)地方标准 由省、自治区、直辖市标准化行政主管部门制定。在地方辖区范围内适用。 (4)企业标准 没有国家标准、行业标准和地方标准的产品,企业应当制定相应的企业标准,企业标准应报当地政府标准化行政主管部门和有关行政主管部门备案。企业标准在该企业内部适用。

新国标GBT 34657交流充电桩互操作性测试方案解读

新国标GB/T 34657交流充电桩互操作性测试方案解读 《GB/T 34657.1-2017 电动汽车传导充电互操作性测试规范第1部分:供电设备》、《GB/T 34657.2-2017 电动汽车传导充电互操作性测试规范第2部分:车辆》已经于2018年5月份正式实施,电动汽车及充电桩行业具备一个详细的测试标准,在新测试标准的监督下电动汽车与充电桩的兼容匹配性将会大大提高。本文将为解读新国标GB/T 34657.1交流桩互操作性测试。 一、测试项目 《GB/T 34657.1-2017 电动汽车传导充电互操作性测试规范第1部分:供电设备》规定的交流充电桩互操作测试项目 二、测试系统组成 标准中提及交流充电桩互操作测试系统的组成,如图所示。主要包括车辆控制器模拟盒(测试交流充电桩的充电控制过程、异常充电状态以及连接控制时序等)、交流电源(模拟电网供电特性)、负载(模拟电池消耗充电桩的输出能量)、测试仪器(测量充电桩的电气特性及控制信号状态等)、主控机(控制车辆控制器模拟盒模拟充电过程的不同状态、采集记录测试仪器的测量数据生成测试报告)。这几部分对充电桩进行有序的联动测试可以大大提高测试效率。

图1、交流充电桩交流充电检测系统 群菱能源新国标的技术要求推出便携式交流充电桩互操作测试设备ACTE-2240H ,设备采用6U标准模块化设计,可安装于便携箱,现场测试方便快捷;满足GB/T 34657.1-2017 《电动汽车传导充电互操作性测试规范第1部分:供电设备》标准要求,包括连接确认测试、充电准备就绪测试、启动及充电阶段测试、正常充电结束测试、充电连接控制时序测试、CC断线测试等交流充电桩互操作测试内容;设备可以实现充电电压、电流、功率、CC阻值、充电状态实时监控。 图2、ACTE-2240H 交流充电桩交流充电测试系统结构 ACTE-2240H 交流充电桩互操作测试设备带有63A标准交流充电枪插座,插座定义满足GB/T 20234.3-2015标准规定的要求;设备带有具备S2和不具备S2两种车辆状态模拟功能;设备带有L1、N、PE、CP、CC各个触点回路通断开关以及CC接地短路开关可实现各路通断、短路故障状态仿真模拟功能;设备带有电动汽车车辆交流充电控制导引仿真电路,具有R2、R3等效电阻仿真功能。

国军标与国标的区别讲解

GJB9001B-2009《质量管理体系要求》的特殊要求 1范围 1.1总则 1.2应用 对质量管理体系要求的删减,需征得顾客同意 2引用标准 GJB 1405 装备质量管理术语 3术语和定义 4质量管理体系 4.1总要求 组织应接受顾客的质量监督。 组织应对外包过程进行评审,批准后予以实施,并监督外包过程的执行。顾客要求时,外包过程须经顾客同意。 适用时,组织应建立、实施和保持产品的可靠性、维修性、保障性、测试性、安全性和环境适应性等工作过程。 注4:外协是外包的一种形式。 注5:适用时组织可参照GJB5000的要求,建立、实施并改进其软件过程。 4.2.3文件控制 h)确保图样和技术文件按规定进行审签、工艺和质量会签、标准化检查。 i)确保图样、技术文件协调一致、现行有效。 j)确保识别产品质量形成过程中需要保存的文件,并及时归档。 4.2.4记录控制 程序应包含对供方产生和保持的纪录的控制要求。 记录应能提供产品实现过程的完整质量证据,并能清楚地证明产品满足规定要求的程度。 记录的保存时间应满足顾客和法律法规的要求,与产品寿命周期相适应。 5管理职责 5.1管理承诺 注:本标准中的最高管理者是指组织的最高行政领导。 5.2以顾客为关注焦点

最高管理者应确保建立并保持定期征求顾客对产品质量及其改进方面意见的机制 5.4.1质量目标 质量目标应体现对产品质量水平的追求,与顾客的期望相适应。组织应保持质量目标实施和评价的纪录。 5.4.2质量管理体系策划 c)对顾客提出的质量管理体系特殊要求作出安排。 5.5.1职责和权限 最高管理者应确保质量管理部门独立行使职权。 最高管理者应对最终产品质量和质量管理负责。 最高管理者应确保顾客能够及时获得产品质量问题的信息。 5.5.2管理者代表 管理者代表应是能参加质量管理体系决策的最高管理层的成员,并具备履行以上职责所需的技术和行政管理能力。 5.6.2评审输入 h)质量经济性分析(见8.4)。 6.2.2能力、意识和培训。 f)对各级管理者以及对产品质量有直接影响的人员应按规定的时间间隔进行有关质量管理知识和岗位技能的培训、考核,并按规定要求持证上岗。 6.4工作环境 对需要控制的工作环境,应保持监视、测量、控制和改进措施的纪录(见4.2.4)。 6.5质量信息 组织应编制形成文件的程序,确定质量信息的需求,按规定收集、贮存、传递、处理和利用。产品质量信息应满足顾客的需求。 7.1产品实现的策划 e)产品标准化要求; f)计算机软件工程化管理要求; g)产品可靠性、维修性、保障性、测试性、安全性和环境适应性要求; h)产品质量评价和改进的数据收集和分析要求; i)技术状态管理要求;

安全使用排插注意事项(2021版)

( 安全常识 ) 单位:_________________________ 姓名:_________________________ 日期:_________________________ 精品文档 / Word文档 / 文字可改 安全使用排插注意事项(2021 版) Safety accidents can cause us great harm. Learn safety knowledge and stay away from safety accidents.

安全使用排插注意事项(2021版) 电源转换器也称排插,是一种量大面广的基础电器附件。其质量好坏,直接关系到各种电器设备的用电安全,与人们的生活和生命财产息息相关。有关资料显示,我国每年发生的电器火灾占全年火灾总数的30%以上,其中由于劣质插座引起的占相当大比例。在此郑重提醒大家,为了您和他人的安全,购买、使用排插时请注意以下几点: 1、购买排插最好到大型商场、超市选购知名品牌,并察看该产品有否通过国家3C强制认证,其标识是否齐全,有无厂名、厂址、产品型号规格、生产日期、检验合格证、使用说明书等;要切记保留好购买排插的单据或小票。 2、选购排插时请注意:排三级插头,接地级可旋转成内藏式的,变成两级的是不宜选择的;排插的插头是两级,可排插板上却有三

级插孔更不宜选购,因为无地线;注意插头与排插上标识的额定电流是否一致;排插插头插销不能太薄、太软;插头插入排插后应接触良好,没有松动的感觉,并且不太费力就能拔出。 3、插座不能放在床上及有易燃易爆物品的地方。 为了您和他人的安全,请使用符合安全标准的排插。近期,宿管员将对所有宿舍进行检查,不符合标准的将收到服务中心统一保管,直到离开本宿舍时再归还。请大家积极配合,安全、规范使用排插。请周知! 云博创意设计 MzYunBo Creative Design Co., Ltd.

国标行标地标企标的解释

行业标准,企业标准,国标.运用的字母 国标 1 GB 中华人民共和国强制性国家标准国家标准化管理委员会 2 GB/T 中华人民共和国推荐性国家标准国家标准化管理委员会 3 GB/Z 中华人民共和国国家标准化指导性技术文件国家标准化管理委员会行标1 BB 包装中国包装工业总公司包改办 2 CB 船舶国防科工委、中国船舶重工集团公司(船舶) 3 CH 测绘国家测绘局国土测绘 司 4 CJ 城镇建设建设部标准定额司(城镇建设) 5 CY 新闻出版国家新闻出版总署印刷业管理司 6 DA 档案国家档案局政法司 7 DB 地震国家地震局震害防预司 8 DL 电力中国电力企业联合会标准化中心 9 DZ 地质矿产国土资源部国际合作与科技司(地质) 10 EJ 核工业国防科工委中国核工业总公司(核工业) 11 FZ 纺织中国纺织工业协会科技发展中心 12 GA 公共安全公安部科技司 13 GY 广播电影电视国家广播电影电视总局科技司 14 HB 航空国防科工委中国航空工业总公司(航空) 15 HG 化工中国石油和化学工业协会质量部(化工、石油化工、石油天然气)16 HJ 环 境保护国家环境保护总局科技标准司 17 HS 海关海关总署政法司18 HY 海洋国家海洋局海洋环境保护司 19 JB 机械中国机械工业联合会 20 JC 建材中国建筑材料工业协会质量部 21 JG 建筑工业建设部(建筑工业) 22 JR 金融中国人民银行科技与支付司 23 JT 交通交通部科教司 24 JY 教育教育部基础教育司(教育) 25 LB 旅游国家旅游局质量规范与管理司

26 LD 劳动和劳动安全劳动和社会保障部劳动工资司(工资定额) 27 LY 林业国家林业局科技司 28 MH 民用航空中国民航管理局规划科技司 29 MT 煤炭中国煤炭工业协会 30 MZ 民政民政部人事教育司 31 NY 农业农业部市场与经济信息司(农业) 32 QB 轻工中国轻工业联合会 33 QC 汽车中国汽车工业协会 34 QJ 航天国防科工委中国航天工业总公司(航天) 35 QX 气象中国气象局检测网络司 36 SB 商业中国商业联合会 37 SC 水产农业部(水产) 38 SH 石油化工中国石油和化学工业协会质量部(化工、石油化工、石油天然气) 39 SJ 电子信息产业部科技司(电子) 40 SL 水利水利部科教司 41 SN 商检国家质量监督检验检疫总局 42 SY 石油天然气中国石油和化学工业协会质量部(化工、石油化工、石油天然气) 43 SY(>10000) 海洋石油天然气中国海洋石油总公司 44 TB 铁路运输铁道部科教司 45 TD 土地管理国土资源部(土地) 46 TY 体育国家体育总局体育经济司 47 WB 物资管理中国物资流通协会行业部 48 WH 文化文化部科教司 49 WJ 兵工民品国防科工委(兵器) 50 WM 外经贸对外经济贸易合作部科技司 51 WS 卫生卫生部卫生法制与监督司 52 XB 稀土国家计委稀土办公室 53 YB 黑色冶金中国钢铁工业协会科技环保部 54 YC 烟草国家烟草专卖局科教司 55 YD 通信信息产业部科技司(邮电) 56 YS 有色冶金中国有色金属工业协会规划发展司 57 YY 医药国家药品监督管理局医药司

移动式插座新国标

移动式插座新国标 2010年6月1日,国家推行发布了插座的新国标规定,这场大改革为整个插座市场带来一次革命性的历史。而作为新国标的主要起草单位及插座新孔型专利所有者,公牛插座积极响应了这次新国标插座的推行和研发,为广大消费者的用电安全再次升级。 自国家强制执了插座新国标起,整个插座行业掀起了一场大改革,我国的插座行业就此走上了新的历程。而插座新国标的主要起草单位及插座新孔型专利所有者公牛插座也为全新的新国标的推行助力,整个插座市场进行了一次大换血,大批劣质插座将因此退出历史舞台,消费者的用电安全也得到了大力提升。同时作为引领中国插座行业发展的领军者,公牛插座将率先响应并贯彻新国标,让更安全的插座产品更快地走进消费者的生活。 新国标助力插座安全,插座行业面临大改革 目前,插座市场上仍留存着一批万用孔插座,没有专业、严格的品质控制的万用孔插座极易为消费者用电安全埋下隐患。近年来,因劣质万用孔插座导致的安全事故频频发生,尤其是在夏季用电高峰,劣质万用孔插座很容易导致火灾,给消费者的用电安全带来了很大的威胁。对于广大消费者而言,新国标插座的生产销售,无疑为其提供了更加安全可靠的用电保障。 因此,新国标明确,淘汰万用孔插座,只允许生产符合新国标组合孔型的插座产品是顺势而行的。据介绍,按照新国标生产的插座产品,插头与插座的接触面积更大,接触更紧密,能有效防止发热,同时,防触电性能更好,这都将大大提升插座产品的安全性能。 并且,插座新国标也列入了3C强制认证,这意味着,国家将进一步加大插座行业安全的监管力度。如此,随着优胜劣汰的良性发展,那些未能达到标准的劣质插座将在新国标的强制执行下丧失竞争力并逐渐淡出市场,届时,中国插座行业的新格局将会逐渐形成,而正如公牛插座这样坚守品质承诺的行业龙头企业,则会以自身的实力引领整个行业的前进方向。 公牛研发国家专利孔型,助推插座新国标发展 作为国内插座行业的领军者,公牛此次助推插座新国标,无疑是其引领行业发展历程中浓墨重彩的一笔。自1995年创立品牌至今,公牛一直秉承以品质为先的企业宗旨,始终按照高于国家标准的质量体系进行品质管控;并始终坚持自主设计研发,在1996年就首创插

论新旧国标排插的区别

排插新国标和旧国标的区别 亲们有没有发现,在新国标组合插排中,三孔与两孔是独立分开的,而且两者离得非常近,直接后果就是不能同时插两个孔了,这不是资源浪费吗? 其实呢,距离那么近,是故意设计的结果,目的就是为了不让你同时插两个插头。因为原来旧国标的插头三孔和二孔的零线火线是共用的,同时使用,可能会超出额定电流,另外容易出现松动、漏电等状况,是极大的安全隐患。 早在2008年底,国家质检总局和国家标准化管理委员会重新修订了插座国家标准。根据规定,从2010年6月1日开始,在生产领域正式实施新国标。但考虑到存货等问题,设定了1年过渡期,规定 2011年6月1日起禁止在流通流域销售旧国标插座。 插座新国标和旧国标的区别 1、新国标对插孔进行了统一规范,只支持扁头的二、三头插孔和圆头的双头插孔。 2、被淘汰的万能插座都标着"按GB2099.3-1997标准生产"或"按GB2099.3-1996标准生产"的字样。符合新国标的产品在包装上标有"按GB2099.3-2008标准生产"的字样。 3、采用旧国标的万能插座三相插孔与两相插孔是合在一起的,总共3个孔;而新国标的三相与两相是分开的,有5个孔。 4、旧国标的插座是一孔多用,新国标是一孔一用。 注意:以上只是2015年以前的标准,新和旧都是相对的。

2015年10月13日,国家标准委批准发布了35项国家标准,新国标涉及健康安全、旅游消费、生态环境等经济社会发展诸多方面。其中《家用和类似用途插头插座》2项强制性国家标准针对转换器和延长线插座两类产品提出了新的要求,其中包括插线板必须设置安全保护门。 此次标准的更新,最重要的当属插座必须设置保护门。 市场上,设置有保护门的排插还不足5%,即使有设置,其市场定位和销售价格也居高不下,普通老百姓难以接受。福田安全插座在国标委发布前就提出有保护门更安全,同时福田安全插座全系列标配安全保护门,插孔只有在对应的两级同时插入时才会完全打开,有效避免了意外触电的情况发生,当有细小的物品掉落时,配备保护门的插座就可以将小物品阻挡在外,避免和内部的电源接触,从而近一步减少意外的发生。而且最重要的是销售价格与普通不带保护门插座价格相当,普通消费者都能够接受。 如果你家还在用旧国标插排,果断换了吧,为了自身和家庭的安全。

新国标插座

新国标插座 新国标插座 简介:2010年6月1日,国家推行发布了插座的新国标规定,这场大改革为整个插座市场带来一次革命性的历史。而作为新国标的主要起草单位及插座新孔型专利所有者,公牛插座积极响应了这次新国标插座的推行和研发,为广大消费者的用电安全再次升级。 自国家强制执了插座新国标起,整个插座行业掀起了一场大改革,我国的插座行业就此走上了新的历程。而插座新国标的主要起草单位及插座新孔型专利所有者公牛插座也为全新的新国标的推行助力,整个插座市场进行了一次大换血,大批劣质插座将因此退出历史舞台,消费者的用电安全也得到了大力提升。同时作为引领中国插座行业发展的领军者,公牛插座将率先响应并贯彻新国标,让更安全的插座产品更快地走进消费者的生活。 新国标助力插座安全,插座行业面临大改革 目前,插座市场上仍留存着一批万用孔插座,没有专业、严格的品质控制的万用孔插座极易为消费者用电安全埋下隐患。近年来,因劣质万用孔插

座导致的安全事故频频发生,尤其是在夏季用电高峰,劣质万用孔插座很容易导致火灾,给消费者的用电安全带来了很大的威胁。对于广大消费者而言,新国标插座的生产销售,无疑为其提供了更加安全可靠的用电保障。 因此,新国标明确,淘汰万用孔插座,只允许生产符合新国标组合孔型的插座产品是顺势而行的。据介绍,按照新国标生产的插座产品,插头与插座的接触面积更大,接触更紧密,能有效防止发热,同时,防触电性能更好,这都将大大提升插座产品的安全性能。 并且,插座新国标也列入了3C强制认证,这意味着,国家将进一步加大插座行业安全的监管力度。如此,随着优胜劣汰的良性发展,那些未能达到标准的劣质插座将在新国标的强制执行下丧失竞争力并逐渐淡出市场,届时,中国插座行业的新格局将会逐渐形成,而正如公牛插座这样坚守品质承诺的行业龙头企业,则会以自身的实力引领整个行业的前进方向。 公牛研发国家专利孔型,助推插座新国标发展 作为国内插座行业的领军者,公牛此次助推插座新国标,无疑是其引领行业发展历程中浓墨重彩的一笔。自1995年创立品牌至今,公牛一直秉承以品质为先的企业宗旨,始终按照高于国家标准的质量体系进行品质管控;并始终坚持自主设计研发,在1996年就首创插座按钮开关,并率先推出具有漏电保护、儿童安全门、防雷、节能等一系列功能性与人性化设计的

直接采用国标行标作为产品标准的说明

直接采用国标/行标作为产品标准的说明企业名称联系电话 产品名称标准编号 执行国标/ 行标的标 准名称 型号规格 要求列出主要技术指标、基本参数在附件上(装订成册) 质量保证的自我声 明 我单位生产的的产品直接执行 标准作为本产品标准注册。该标准可保证产品的安全性、有效性,无需增加技术指标已可保证产品安全、有效。如发生因质量引起的纠纷,由我单位承担产品上市后的质量责任,特此声明。 法人代表(签字盖章): 年月日 备注此表应打印,盖公章。 注1:此表+采用标准文本+出厂自测报告复印件(装订成册)3份。注2:使用说明书、图片 1份。

医疗器械注册产品标准复核意见表 标准名称标准编号 企业名称联系电话 企业地址邮政编码 联系人手机 我声明,对提交复核的注册产品标准规定的内容负责。 法人批准签章-------------- 年月日复核意见: 复核人:负责人签字: 年月日年月日 注1:此表一式二份。 注2:标准文本封面加盖公章+编制说明(装订成册,一式五份)。 注3:产品自测报告中自测项目为注册标准中规定的出厂检测项目、有主检、审核人签字。

附件一 企业产品标准备案登记表 备案号:QB/440000 11 -20 企业代码:登记号:粤药标字(20 ) 标准名称标准号 产品名称型号 规格 企业名称电话 地址邮编 标准化负责人 签名 年月日企业法人(加盖企业公章)年月日 有关行政主管 部门 负责人签名(盖章)年月日 标准化行政主 管部门 负责人签名(盖章)年月日 备案地点:广州市南田西路省技术监督局标准化处 84437442 84237580 一式三份。

茂名市食品药品监督管理局 广东省企业产品标准修改通知单 : 关于你单位备案的企业产品标准《 》,现申请修改。 标准号:,登记号:粤药械标字(200 )号; 备案号:QB/440000 11 。 修改理由及内容简述如下: 经研究同意你们的修改意见。自本通知发出之日起,本通知所审批内容与原标准一并执行。特此通知。 附件: “申请修改标准的报告” 年月日抄送:广东省食品药品监督管理局医疗器械监管处。

安全使用排插注意事项通用版

管理制度编号:YTO-FS-PD243 安全使用排插注意事项通用版 In Order T o Standardize The Management Of Daily Behavior, The Activities And T asks Are Controlled By The Determined Terms, So As T o Achieve The Effect Of Safe Production And Reduce Hidden Dangers. 标准/ 权威/ 规范/ 实用 Authoritative And Practical Standards

安全使用排插注意事项通用版 使用提示:本管理制度文件可用于工作中为规范日常行为与作业运行过程的管理,通过对确定的条款对活动和任务实施控制,使活动和任务在受控状态,从而达到安全生产和减少隐患的效果。文件下载后可定制修改,请根据实际需要进行调整和使用。 电源转换器也称排插,是一种量大面广的基础电器附件。其质量好坏,直接关系到各种电器设备的用电安全,与人们的生活和生命财产息息相关。有关资料显示,我国每年发生的电器火灾占全年火灾总数的30%以上,其中由于劣质插座引起的占相当大比例。在此郑重提醒大家,为了您和他人的安全,购买、使用排插时请注意以下几点: 1、购买排插最好到大型商场、超市选购知名品牌,并察看该产品有否通过国家3C强制认证,其标识是否齐全,有无厂名、厂址、产品型号规格、生产日期、检验合格证、使用说明书等;要切记保留好购买排插的单据或小票。 2、选购排插时请注意:排三级插头,接地级可旋转成内藏式的,变成两级的是不宜选择的;排插的插头是两级,可排插板上却有三级插孔更不宜选购,因为无地线;注意插头与排插上标识的额定电流是否一致;排插插头插销不能太薄、太软;插头插入排插后应接触良好,没有松动的感觉,并且不太费力就能拔出。

国家标准和行业标准有什么区别

国家标准和行业标准有什么区别 对需要在全国范围内统一的技术要求,应当制定国家标准。国家标准由国务院标准化行政主管部门制定。对没有国家标准而又需要在全国某个行业范围内统一的技术要求,可以制定行业标准。行业标准由国务院有关行政主管部门制定,并报国务院标准化行政主管部门备案,在公布国家标准之后,该项行业标准即行废止。对没有国家标准和行业标准而又需要在省、自治区、直辖市范围内统一的工业产品的安全、卫生要求,可以制定地方标准。地方标准由省、自治区、直辖市标准化行政主管部门制定,并报国务院标准化行政主管部门和国务院有关行政主管部门备案,在公布国家标准或者行业标准之后,该项地方标准即行废止。 企业生产的产品没有国家标准和行业标准的,应当制定企业标准,作为组织生产的依据。企业的产品标准须报当地政府标准化行政主管部门和有关行政主管部门备案。已有国家标准或者行业标准的,国家鼓励企业制定严于国家标准或者行业标准的企业标准,在企业内部适用。 行标是行标,国标是国标,不一样的。 按照适用范围,我国的标准分为国家标准、行业标准、地方标准和企业标准四个级别。 (1)国家标准 由国务院标准化行政主管部门(现为国家质量技术监督检验检疫总局)指定(编制计划、组织起草、统一审批、编号、发布)。国家标准在全国范围内适用,其他各级别标准不得与国家标准相抵触。 (2)行业标准 由国务院有关行政主管部门制定。如化工行业标准(代号为HG)、石油化工行业标准(代号为SH)由国家石油和化学工业局制定,建材行业标准(代号为JC)由国家建筑材料工业局制定。行业标准在全国某个行业范围内适用。 (3)地方标准 由省、自治区、直辖市标准化行政主管部门制定。在地方辖区范围内适用。 (4)企业标准 没有国家标准、行业标准和地方标准的产品,企业应当制定相应的企业标准,企业标准应报当地政府标准化行政主管部门和有关行政主管部门备案。企业标准在该企业内部适用。

国家标准和行业标准有什么区别

国家标准和行业标准有 什么区别 文稿归稿存档编号:[KKUY-KKIO69-OTM243-OLUI129-G00I-FDQS58-

国家标准和行业标准有什么区别 对需要在全国范围内统一的技术要求,应当制定。由国务院标准化部门制定。对没有而又需要在全国某个行业范围内统一的技术要求,可以制定。由国务院有关部门制定,并报国务院标准化部门备案,在公布国家标准之后,该项即行废止。对没有国家标准和行业标准而又需要在省、自治区、范围内统一的工业产品的安全、卫生要求,可以制定。由省、自治区、标准化行政主管部门制定,并报国务院标准化行政主管部门和国务院有关行政主管部门备案,在公布国家标准或者行业标准之后,该项即行废止。 企业生产的产品没有国家标准和行业标准的,应当制定,作为组织生产的依据。企业的须报当地政府标准化行政主管部门和有关行政主管部门备案。已有国家标准或者行业标准的,国家鼓励企业制定严于国家标准或者行业标准的,在企业内部适用。 行标是行标,国标是国标,不一样的。 按照适用范围,我国的标准分为国家标准、行业标准、地方标准和企业标准四个级别。 (1)国家标准 由国务院标准化行政主管部门(现为国家质量技术监督检验检疫总局)指定(编制计划、组织起草、统一审批、编号、发布)。国家标准在全国范围内适用,其他各级别标准不得与国家标准相抵触。 (2)行业标准

由国务院有关行政主管部门制定。如化工行业标准(代号为HG)、石油化工行业标准(代号为SH)由国家石油和化学工业局制定,建材行业标准(代号为JC)由国家建筑材料工业局制定。行业标准在全国某个行业范围内适用。 (3)地方标准 由省、自治区、直辖市标准化行政主管部门制定。在地方辖区范围内适用。 (4)企业标准 没有国家标准、行业标准和地方标准的产品,企业应当制定相应的企业标准,企业标准应报当地政府标准化行政主管部门和有关行政主管部门备案。企业标准在该企业内部适用。

新国标下的排插解析

新国标下的排插解析 炎炎夏日意味着又一个用电高峰期即将到来。随着大功率电器使用频率越来越高,各式各样的用电安全问题成为每个人都需要考虑的大事。而墙插与排插产品的质量水平,则直接影响着用电安全。国家质检总局和中国国家标准化管理委员会2010年6月1日发布的家用排插新国标从2011年6月1日强制执行。也就是说,在6月1日之后,所有的大 万用排插将被视为不合格产品。 新国标规范市场 新国标旨在规范早已良莠不齐的排插市场。在新国标没有推出之前,大万用排插由于良好的通用性而在市场上流行。它的生产门槛较低,又没有严格的行业标准约束生产方,所以产生的问题不少,其实插座并不是越“万能”越好。“新 国标”的主旨是为了保证居民安全用电,而万用插座没有统一的尺寸规范,插孔相对较大,“插拔力”不容易达标,即 插头容易松动,存在火灾隐患,特别是在夏季这种用电高峰期,特别危险。所以“新国标”对排插的外观、尺寸、性能等方面均给出了明确的规范。

劣质大万用排插害人不浅 新国标规范作用难以体现 由于大万用排插可以采用手工焊接的方式制造,门槛很低,十几人的小作坊都可以生产出大量的大万用排插,而这种排插售价非常低廉,因此劣质的排插以低廉的价格迅速占领市场,给消费者用电埋下隐患。新国标提高了排插的制造门槛,并对包括接触面、防触电能力、模块结构、接地措施等方面做了严格的要求,这样的要求使得排插生产方的制造难度变高,小作坊已经没办法达到工艺要求,直接被淘汰掉。而一些小厂商为了生存,也不得不提高自己的生产工艺,生产符合新国标的排插,继续存在于排插市场。可以说,新国标的实施,就是为了规范排插市场,遏制劣质排插出现在市场上,保证了消费者的用电安全。 但是新国标强制执行已接近一个月,在排插市场上采用新国标制造的产品并不多见,而大万用排插仍然在各大超市与卖场销售。就目前来看,国家并没有强制规定在新国标实施后,所有大万用排插必须下架。而另一方面,消费者并没有强烈地意识到大万用排插可能带来的隐患,而大万用排插良好的通用性仍然是吸引目光的卖点。 走在国标路上的新排插

什么是国际标准国标行标地标

什么是国际标准、国家标准、行业标准、企业标准? 1、标准化的层次指标准化所涉及的地理、政治或经济的范围 标准化可以在全球或某个区域或某个国家层次上进行。在某个国家或国家的某个地区内,标准化也可以在一个行业或部门(例如政府各部)、地方层次上、行业协会或企业层次上,以至在车间和业务室进行。 2、我国的四级标准 国家标准(代号:GB) 行业标准(代号如:JY、JB、SJ、YD、QB、YY、JC、WS、GA) 地方标准(代号如:DB33) 企业标准(代号:Q/×××) “级”指的是层次,不是行政级别。 3、各层次的标准 (1) 国际标准:由国际标准化组织或国际标准组织通过并公开发布的标准。 例:ISO——国际标准化组织标准 IEC——国际电工委员会标准 其他还有: 代号含义 CAC 食品法典委员会标准 CIE 国际照明委员会标准 ICRP 国际辐射防护委员会标准 ICRU 国际辐射单位和测量委员会标准 ITU 国际电信联盟标准 UNESCO 联合国科教文组织标准 WHO 世界卫生组织标准 WIPO 世界知识产权组织标准 ………… (2)区域标准:由区域标准化组织或区域标准组织通过并公开发布的标准。 例:EN——欧洲标准 CEN——欧洲标准化委员会标准 CENELEC——欧洲电工标准化委员会标准 (3)国家标准:由国家标准机构通过并公开发布的标准。 例:GB——中国国家标准 ANSI——美国国家标准 DIN——德国国家标准 BS——英国国家标准 …… (4)行业标准:由行业标准机构制定和发布的标准。 例:JY——教育行业标准 JB——机械行业标准 SJ——电子行业标准 YD——通信行业标准 QB——轻工行业标准我国的行业标准 YY——医药行业标准 JC——建材行业标准

插座新国标和旧国标有什么区别

插座新国标和旧国标的区别 这里所说的插座新旧国标都是指插座生产的国家标准。根据时代的进步,国家也越来越重视人民的用电安全,因此不断的推出新的插座生产标准。 1、新国标对插孔进行了统一规范,只支持扁头的二、三头插孔和 圆头的双头插孔。 2、被淘汰的万能插座都标着"按GB2099.3-1997标准生产"或"按 GB2099.3-1996标准生产"的字样。符合新国标的产品在包装上标有"按GB2099.3-2008标准生产"的字样。 3、采用旧国标的万能插座三相插孔与两相插孔是合在一起的,总 共3个孔;而新国标的三相与两相是分开的,有5个孔。 4、旧国标的插座是一孔多用,新国标是一孔一用。 有没有发现,在新国标组合插排中,三孔与两孔是独立分开的,而且两者离得非常近,直接后果就是不能同时插两个孔了,这不是资源浪费吗? 其实呢,距离那么近,是故意设计的结果,目的就是为了不让你同时插两个插头。因为原来旧国标的插头三孔和二孔的零线火线是共用的,同时使用,可能会超出额定电流,另外容易出现松动、漏电等状况,是极大的安全隐患。 其实,早在2008年底,国家质检总局和国家标准化管理委员会重新修订了插座国家标准。根据规定,从2010年6月1日开始,在生产领域正式实施新国标。但考虑到存货等问题,设定了1年过渡期,规定 2011年6月1日起禁止在流通流域销售旧国标插座。 如果你家还在用旧国标插排,果断换了吧,为了自身和家庭的安全。 2015年10月13日,国家标准委批准发布了35项国家标准,新国标涉及健康安全、旅游消费、生态环境等经济社会发展诸多方面。其中《家用和类似用途插头插座》2项强制性国家标准针对转换器和延长线插座 两类产品提出了新的要求,其中包括插线板必须设置安全保护门。 此次标准的更新,最重要的当属插座必须设置保护门。 市场上,设置有保护门的排插还不足5%,即使有设置,其市场定位和销售价格也居高不下,普通老百姓难以接受。在这给大家推荐一款由广东福田电器有限公司历时三年精心打造的福田安全插座,自诞生之日起,在国标委发布前就提出有保护门更安全,同时福田安全插座全系列标配安全保护门,插孔只有在对应的两级同时插入时才会完全打开,有效避免了意外触电的情况发生,当有细小的物品掉落时,配备保护门的

国标线缆与行标及非标线缆的区别

国标线缆与行标及非标线缆的区别 一、定义: 1、国标线缆:根据国家出台的相关线缆标准的技术所生产的线缆简称国际线。 2、行标线缆:根据行业标准,主要是有较少的偷工减料,但不影响大的使用性能。 3、非标线缆:为适应市需求应孕而生的产品。 二、特点及检测方法: 1、国标线缆:严格按国家出台的相关线缆行业的标准所生产的线缆,如:数量,电阻,阻抗,原材料,衰减,绝缘材料。主要几大参数确定基本可以判定:原材料-----无氧铜丝,包装误差0.5%,护套--新的PVC 料而不是回收料等。 2、行标线缆:原材料相同于国标,主要体现在偷工减料上面,常出现的地方是: A:线径:如:电源线:主要是降低线径如2平方的做成 1.8或 1.9,0.5变成0.47等,节约成本大概5%-10%。主要会影响到产品的寿命。 B:工艺: 简化工艺如:如视频线主要减少的是它的屏蔽层的数量,如128编变成120,96变成90等,信号线RVVP系列的也是降低屏蔽密度一般在90%以

上,行标线一般在80%左右的密度。另外电源线主要体现在减少工艺如减去抗拉材料等。节约成本大概5%-10%,主要会影响到产品的性能,抗干扰能力降低。C:数量上:主要是加大米数的误差一般在2%-5%左右。可节约成本2%-5%,不会影响使用效果与寿命,但会影响成本,严重的会影响设计的结果。 这些都一般场合不会影响使用,就有很工程商认为也是国标线。一般只在特定场合才会出现不良后果,在工程使用之中,完工当时可能不出问题,但是如果碰到环境的变化,周边干扰加,电源电压不稳定,湿度变化等等就会体现出来,会严重影响使用寿命,安全,交率等问题,但前提是设计上要合理到位,所在关键在于设计上的先型。如果设计上未留太多的空间,此类产品在严格的工程上一般不推荐使用。 所以主要的检测上主要是对比以上ABC三大参数。具体使用到的工具就简单的目测,实没,千分尺,量尺,称等即可。 一般行标产品比国标产品低10%-15%左右的成本,再低就变成非标产品了,也就是加大偷工减料的幅度,但这样会影响使用效果以及寿命。 3、非标线缆:非标线缆也分较多的等级,依次:原材料:无氧铜丝--------回收铜(含铜量低)--------铜包

相关主题