搜档网
当前位置:搜档网 › 申菱空调机组操作使用说明书

申菱空调机组操作使用说明书

申菱空调机组操作使用说明书
申菱空调机组操作使用说明书

组合式空调机组操作手册V1

目录 Content 一、安全须知 (3) I. Safety Tips 二、安装 (5) II. Installation 1. 安装前的准备 (5) 1. Preparation before Installation 2. 散件出厂机组的现场组装和交付 (5) 2. Site Assembly & Delivery of Parts Delivered in Bulks 3. 整机出厂机组的现场吊装和就位 (6) 3. Site Hoisting & Locating of Parts Delivered in Whole Set 4. 机组与风系统的安装和连接 (11) 4. Installation & Connection of Units and Air System 5. 机组与水汽管路系统的安装和连接 (11) 5. Installation & Connection of Units and Water-and-Steam System 6. 机组与电气控制系统的安装和连接 (14) 6. Installation & Connection of Units and Electric Control System 三、调试 (15) III. Commission 1. 调试前的准备 (15) 1. Preparation before Commission 2. 启动关闭机组 (22) 2. Units On & Off 四、运行管理 (26) IV. Operation & Management 1. 性能参数巡检记录 (26) 1. Performance Parameters Inspecting Record 2. 设备运行参数监测 (26) 2. Running Parameters Inspection 3. 设备运行状态监测 (27) 3. Running Status Inspection 五、例行保养和维修 (29) V. Regular Maintenance & Repairing

LED显示屏控制软件操纵使用说明(灵信V3.3)

第一章概述 1.1 功能特点 《LED Player V3.3》是本公司新推出的一套专为LED显示屏设计的功能强大,使用方便,简单易学的节目制作、播放软件,支持多种文件格式:文本文件,WORD文件,图片文件(BMP/JPG/GIF/JPEG...),动画文件(SWF /Gif)。 2.2 运行环境 操作系统 中英文Windows/7/NT/XP 硬件配置 CPU: 奔腾600MHz以上 内存:128M 相关软件 OFFICE2000--如需WORD文件必须安装

第二章安装与卸载 2.1 安装 《LED Player》软件安装很简单,操作如下:将LED Player播放软件的安装光盘插入电脑光驱,即可显示LED Player播放软件的安装文件,双击LED Player,即可实现轻松安装。 《LED Player》软件安装成功后,在【开始】/【程序】里将出现“LED软件”程序组,然后进入该程序组下的“LED Player”,单击即可运行,如图所示, opyright ? 2005-2007 Listen tech. All Rights Reserved 灵感设计诚信 同时,桌面上也出现“LED Player”快捷方式:如右图所示,双击它同样可以启动程序。

2.2 卸载 《LED Player》软件提供了自动卸载功能,使您可以方便地删除《LED Player》的所有文件、程序组和快捷方式,用户可以在“LED软件”组中选择“卸载LED Player”,也可在【控制面板】中选择【添加/删除程序】快速卸载. 第三章使用详解 3.1 节目组成 每块显示屏由一个或多个节目页组成。节目页是用来显示用户所要播放的文本、图片、动画等内容。区域窗口有十一种:图文窗、文本窗、单行文本窗、静止文本窗、时间窗、正计时窗、倒计时窗、模拟时钟窗、表格窗、动画窗、温度窗。 文件窗:可以播放各种文字、图片、动画、表格等几十种文件。 文本窗:用于快速输入简短文字,例如通知等文字。 单行文本窗:用于播放单行文本,例如通知、广告等文字。 静止文本窗:用于播放静止文本,例如公司名称、标题等文字。 时间窗:用于显示数字时间。 计时窗:用于计时,支持正/倒计时显示。

空调操作使用说明书样本

空调机组 操作使用说明书 ( 程序版本号: FLCCU3212_V1.5) 广东申菱空调设备有限公司

空调机组用户说明 在手操器上我们能够看到总共有6个轻触式按钮, 在每一个轻触式按钮的下面, 都有一个指示灯, 当按下其中一个键或者同时按下两个按键时, 屏幕显示相对应的菜单。为了方便以后的叙述, 将上述各键自左至右, 从上到下定义如下: 1.故障( ALARM) 键; 2.程序( Prg) 键; 3.退出( Esc) 键; 4.UP( ) 键; 5.ENTER( ) 键; 6.DOWN( ) 键; 当同时按下和键, 您能够切换各个菜单, 然后按键能够进入您所选择的菜单里; 按或键, 您能够查看所选择菜单里的各项内容。 因为控制面板菜单有中文和英文两种, 您能够经过按键和键来切换中英文画面。 当需要设定或者修改机组的各项参数时, 您能够按键来选择需要修改的参数项, 然后按/键来修改数值, 修改完毕后按键确认。当按下Esc键时, 您就能够退出该栏菜单。 当机组出现故障时, 手操器左上角的ALARM键会亮红灯; 此时按下该键您就能够在显示屏幕上看到相应的故障信息。当机组存在多项故障时, 您能够经过按/键来翻看各项故障信息。当故障排除后, 您能够按ALARM键来复位故障报警。 机组开停控制: 在遥控按Prg键可在手操器显示任何画面时开/停机组。Prg 键和遥控开关的关系为: 控制空调机开机后, 空调机开关状态即受异地遥控开

关的控制。此时如果遥控开关断开, 空调机停机; 遥控开关闭合, 空调机正常运行。 如果机组使用PLAN网络以实现机组之间的轮值备用功能, 网络中机组数目当然大于一台, 此时可经过同时按键和键来切换不同机组的画面, 屏幕右上角的数字表示机组编号, 如显示”01”表示第一号机组。 1.输入及输出 1.1模拟量输入 REFERENCE Small Version Medium Version B1 回风压差回风压差 B2 回风湿度回风湿度(0~10V或4~20mA) B3 外部设定温度( 0~10VDC) 外部设定温度( 0~10VDC) B4 回风温度( NTC) 回风温度( NTC) B5 新风温度( NTC) 新风温度( NTC) B6 N/A 回风温度(0~10V或4~20mA) B7 N/A 外部设定湿度( 0~10VDC) B8 N/A 备用 1.2数字量输入 REFERENCE Small Version Medium Version 1 风机电机过载风机电机过载 2 欠风保护开关欠风保护开关 3 客户自设报警客户自设报警 4 压缩机一电流过载或高压保护压缩机一电流过载或高压保护 5 压缩机一低压保护压缩机一低压保护 6 电加热过热保护电加热过热保护 7 遥控开关遥控开关 8 遥控值班功能( 该点闭合, 机组值班运行) 遥控值班功能( 该点闭合, 机组值班运行) 9 N/A 压缩机二电流过载或高压保护 10 N/A 压缩机二低压保护 11 N/A 压缩机三电流过载或高压保护 12 N/A 压缩机三低压保护 13 N/A 初效滤网堵塞/直冷或冷冻水选择 14 N/A 中效滤网堵塞/电加热或热水选择 1.3 数字量输出 REFERENCE Small Version Medium Version R1 送风机电机送风机电机 R2 压缩机一压缩机一 R3 电加热一电加热一

风冷模块机组使用说明书

风冷模块机组功能说明书 1.0概述 DFSS-5MK控制器适用于水源冷(热)水机组,可以控制单台或6压缩机,控制器由室外主板和室内线控器组成,并有风盘联动接口。 2.0主要技术参数 2.1使用条件 运行电压:AC220V±10%;运行环境温度:-20~+55℃;储存温度:-35~+85℃;湿度要求:0~95%RH 2.2温度控制精度:1℃ 2.3控制器符合 □GB4706.1-1988《家用和类似用途电器的安全第一部分:通用要求》 □GB4706.32-1996《家用和类似用途电器的安全热泵﹑空调器和除湿机的特殊要求》 □GB18430.1-2001《蒸汽压缩机循环冷水(热泵)机组工商业用和类似用途的冷水(热泵)机组》 □GB18430.2-2001《蒸汽压缩机循环冷水(热泵)机组户用和类似用途的冷水(热泵)机组》 □抗干扰度符合GB4343.2-1999 □印刷电路板符合GB4588.1和GB4588.2的规定 3.0控制器功能 制冷运行 制热运行 可显示回水温度及设置温度,具有查询功能 掉电自动记忆各种参数 压缩机均衡运行及分时启动 三相缺相,逆相保护 具有完善的保护功能及显示 具有风盘联动接口 选用摩托罗拉高性能芯片,抗干扰性能达到最好 具有定时开关机功能 4.0面板操作 室内线控器面板如图一

按“运转/停止”键,机组开机,指示灯亮; 再按“运转/停止”键,机组关闭,指示灯灭。 开机,关机均存储数据。 4.2.模式转换 按“模式”键,选择所需的模式,“制冷”“制热”模式 “制冷”模式显示雪花符号 “制热”模式显示太阳符号 (默认在关机状态下才可转换模式) 4.3.定时开关机 设置〖b7〗设置为0时是组合定时(设置请参阅下面设置章节) 开机状态下,按“定时”键,定时关机; 关机状态下,按“定时”键,定时开机; 按“定时”键后,小时时间闪显; 按“时间▽△”键,调整小时定时时间 再按“定时”键后,分钟时间闪显; 按“时间▽△”键,调整分钟定时时间 再按“定时”键,定时设定完成 再按“定时”键,则取消定时 设置〖b7〗设置为1时是循环定时 按“定时”键后,小时时间闪显,开始设定定时开时间; 按“时间▽△”键,调整小时定时开时间 再按“定时”键后,分钟时间闪显; 按“时间▽△”键,调整分钟定时开时间 再按“定时”键,小时时间闪显,定时开时间设定完毕,开始设定定时关时间; 按“时间▽△”键,调整小时定时关时间 再按“定时”键后,分钟时间闪显; 按“时间▽△”键,调整分钟定时关时间 按“定时”键,定时关时间设定完成 4.4.时钟设定 按住“定时”键5秒键后,小时时间闪显,进入时钟设定状态; 按“时间▽△”键,调整小时时钟 再按“定时”键后,分钟时间闪显; 按“时间▽△”键,调整分钟时钟 再按“定时”键,时钟设定完成 4.5.查询 循环定时(〖b7〗设置为1)时,按“查询”键可显示实时时间。 按“查询”键,进入参数查询状态,再按“时间▽△”键可查询d1 d2 d3 d4 d5 E1 E2 E3 E4 E5 E6 E7 E8的参数,再按“查询”键退出查询状态。 注:按“时间▽△”键可查询 d1内出水温度d2内回水温度,d3室外空气温度,d4外出水温度4,d5外回水温度 E1(主模块)历史故障,E2(2#模块)历史故障,----- E8(8#模块)历史故障 4.6.参数设置 用户级参数设置( 设置温度设置) 按“设置”键进入用户级温度设置,显示“P1”及参数,接着按“温度▽△”键可设定P1(制冷 设置温度)的参数 再按“时间▽△”键,则显示“P2”及参数,接着按“温度▽△”键可设定P2(制热设置温度)

组合式空调控制器面板操作说明

DX-9100 数字控制器面板操作说明 1. 请仔细阅读“操作说明”后,参照“操作说明”结合“自控调试表” 操作,非专业人员禁止操作。 2. 所有通讯地址、接线非专业人员禁止操作。 3. 控制程序与之相对应的送风机连锁。 4、控制程序与消防连锁。 一、面板布置 二、启动模式 三、下载模式 四、时间调度模式 五、时间调度事件编程 六、实时时钟日历 七、模拟输入显示模式 八、模式滚动模式 九、数字输入显示模式 十、输出模块显示模式 十一、数字计数器显示模式 十二、可编程功能模块显示模式 十三、模拟/ 数字常量显示模式

一、面板布置 本空调机组中采用美国江森DX-9100-8154 控制器(2 型),控制器内的 工作参数和值可以通过前面板显示出来并修改。前面板的布置由七个功能块组成,这些功能块包括用来完成许多种任务的发光二极管、数码管和操作键。 A C B E2 D2 G F Service Module Socket 1 2 3 4 5 6 7 8 R D TD AL XT X D K X Y Z D A/M Y XT 0 1 1 0 Z A 0 K A/M E ESC emdxtb60 图:DX-9100-8454(2 型) 的前面板布置图 1. 功能块的功能 1)功能块A:两个七段绿色数码管显示所选项目的索引号。 2)功能块B:四个七段红色数码管监视、显示并更新所选项目的值: ·模拟输入、输出和常数以数字表示。 ·数字输入、输出和常数以“ON”或“OFF”表示。 ·数字输入的计数器及其他合计值以数字表示,交替显示“个”位和“千”位数。 3) 功能块C:八个红色发光二极管指示DX(或为在功能块A中选中的XT)的数 字输入的状态,在时间调度模式下为定时模块中的星期日期以及在实时时钟模式下的当前星期日期。 4)功能块D2:上方的两个红色发光二极管分别指示,在N2总线(91 总线)上接收数据时RD灯点亮,DX-9100控制器经N2总线(91 总线)发送数据时TD

LXM调试软件Somove使用说明

L X M26调试软件S o m o v e使用说明安装LXM26调试软件调试软件 如果没有安装Somove,需要先安装Somove 下载地址: 安装好Somove 后需要安装Lexium26 的DTM 下载地址: 软件注册 如果尚未注册软件系统会自动提示注册,注册是免费的。 连接电脑 Lexium26通过CN3口(modbus485)和电脑进行通讯,施耐德标准通讯线缆型号是TCSMCNAM3M002P,此电缆连接电脑一端为USB口 在第一次进行调试时,需要查明电脑分配给此调试电缆的COM口,打开硬件管理器就可以看到,此处为COM4 确认COM口后,需要在Somove里面设定对应的COM口,单击编辑链接 选择modbus串行,并单击最右边编辑图标 选择对应的COM端口,单击应用并确定

然后电脑和伺服驱动器的通讯就可以开始了,单击连接 选择Lexium26 ,并单击连接 参数上载后后可以进行Somove在线调试 我的设备 用途:我的设备页面用于显示伺服驱动器和电机的基本信息,包括 驱动器型号 驱动器序列号 驱动器固件版本 电机型号 驱动器额定/峰值电流 电机额定/峰值转速 电机额定/峰值扭矩 … 参数列表 用于:参数列表页面用于设置驱动器P参数,可以按照P参数组开设置,也可以按照操作模式来设置。 相关参数说明可以在Lexium26手册第九章查询

错误内存 用途:错误内存界面用来查看伺服的故障历史,可以显示当前故障,已经5次历史故障,并且指明故障原因和处理方式。 可视化 用途:可视化界面用于显示以下信号的状态或者数值 数字输出/输出 模拟量输入/输出 指定参数的数值 指定参数显示需要 1.选定要显示的参数 2.在右侧区域用鼠标选择显示区域 示波器 用途:可同时捕捉驱动器内部的最多4个变量,例如电流、电压、位置误差、实际速度等,并绘制成以时间为横坐标的曲线图,以此观察驱动器及电机的运行性能是否符合要求,并相应的做出控制环参数调整。 左侧三个输入区域分别用于: Channels:选择希望监视的参数 Trigger:选择开始捕捉参数的触发条件 Settings:选择需要做出调整的控制环参数 这三个输入区域可以分别用右侧示波器栏顶部的三个按钮打开 这是右侧示波器栏顶部的一排按钮,它们的功能是这样的: :用于打开和关闭左侧三个输入区域 :用于加载和保存捕捉到的波形文件 :用于导出和导入示波器的配置文件 :分别用于给波形曲线加注释,将波形拷贝为图形文件(*.png),设置FFT功能的采样参数 :用于对波形进行放大、缩小、移动 :分别用于在波形上加两个光标以准确读出光标点的数值,在示波器上显示波形名称样例,对波形进行FFT转换观察频域分布 示波器的一般使用顺序为: 1.在左边第一个输入区域中选择希望捕捉的参数: 1)按打开可以捕捉的参数列表,示波器同时最多捕捉4个参数

设备使用说明书

镇江恒源汽车零部件有限公司立式收口机使用说明书 立式收口机 使 用 说 明 书 镇江市恒源汽车零部件有限公司

非常感谢您选择使用镇江市恒源汽车零部件有限公司生产的立式收口机,请详细阅读本品的使用说明书,以便于您的安全使用。 目录 1.安全说明 (3) 2.设备用途和适用范围 (7) 3.设备参数 (7) 4.设备动力系统 (8) 5.设备操纵系统 (12) 6.设备电气系统 (16) 7.设备冷却系统 (26) 8.设备运输、安装及试车 (27) 9.设备维护与保养 (29) 10.设备的结构及调整 (37) 11.设备易损零件及加工图 (38) 12.设备功能简介 (39)

1.安全说明 1.1安全规则概要 操作者使用设备前必须认真阅读安全说明,安全人员要确告操作者设备的要求。 1)设备的操作、维护和修理人员必须经过专业培训,有能力预见风险、有安全意识并能预测风险的人才能操作设备。 2)操作和维护人员必须认真阅读和掌握操作说明。 3)设备停止操作后,主油缸由于液压惯性还有短暂动作时间,应注意在工件停止前身体部位不得进入加工区域和触摸工件。 4)各种安全防护罩不得随意拆卸或改装,维护和修理时,应切断主电源。 5)设备上的各种安全警示标志不得随意拆卸,并要经常保持其干净、清晰。 警告:设备通电后,千万不要用手触摸模具和运动部件 6)设备的操作、维修和调整必须由专业人员进行,其他人员不得随意起动设备。 7)应按工艺规程操作设备,应由专业维修人员修理设备。 8)调整和维修设备时所用的扳手和钳子等工具必须是标准工具。 9)设备出现异常现象时应立即停机,并由专业维修人员及时检查和维修。 10)在拆卸和装配设备时,应使用有足够承载能力的起吊装置。 11)严格遵守设备上的安全说明和安全警告,并且确保其完整、清晰。 12)操作设备前要进行安全检查,确定各行程及限位开关、撞块、急停按钮、光栅安全可靠。 13)维修或调整设备前一定要在开关关闭、电源切断、工件完全停止的状态下进行。 14)操作人员不要穿宽松的衣服、袖口必须扎紧,不要戴领带、珠宝(戒指、手表等),必须戴护目镜和穿劳保鞋。 15)操作设备时,不论男女,长发必须戴工作帽并将其包裹在内。 16)整机噪音不大于75dB。建议穿戴适当的劳保用品,例如,戴听力保护器以减少听力的损失。 17)设备周围工作区要保持干净、明亮整洁、光线适宜,附近不能放置杂物,以免给操作者带来不便。 18)设备运行、加工时,不许移动各处防护罩。 19)离开设备时,必须关闭设备主电源开关。 20)设备重新起动时,必须对设备进行重新复位。 21)设备上,特别是设备的运动部件周围不能放置工件、工具等物件。 22)主油缸动作前一定要将工件(工装)固定牢靠,人员离开工作区域后才可起动设备。

D06调试软件说明

D06调试软件说明 首先要将D06按照使用说明书安装好。用汽油启动汽车,通过专用串口连接线把D06与PC 机连接。启动D06调试软件。 启动后的主界面: VEHICLE CONFIGURATION 参数配置 DISPLAY 数据显示 AUTOCALIBRATION 自动配置 SA VE CONFIGURATION 保存配置 LOAD CONFIGURATION 读入配置 ECU REPROGRAMMING 重新编程 EXIT 退出

选择语言,操作如下图: 进入VEHICLE CONFIGUNATION 菜单,内部有F1、F2、F3、F4四张表格。F1表格的内容如下图:

Fuel type 燃料类型 默认状态: LPG (液化气) 选择项: Methane (天然气) Inj、喷射的方式 默认状态:Sequential (顺序喷射) 选择项:Full Group (分组喷射) Injectors 喷嘴类型 默认状态:Omvl FAST 选择项:Omvl STD Reducer:减压器类型燃料类型选择为Methane时,就没有此选项 默认状态: STD 选择项:MP 选择项:HP Type of revolution signal 转速信号的类型 默认状态:Standard 选择项:Weak No、of cylinders 汽缸数 默认状态:4 Cylinders 选择项:3 Cylinders Ignition type 线圈类型 默认状态:Two coils 选择项:One coil 选择项:RPM sensor 选择项:RPM sensor2 Type of change over 转换类型 默认状态:In acceleration 选择项:IN DECELERTION REV、THRESHOLD FOR CHANG-OVER 转换的转速 默认状态:1600 选择项:800—3000 REDUCER TEMPERATURE FOR CHANGE-OVER 转换时的减压器温度 默认状态:30

设备操作说明书

废水处理设备 系统操作说明书 苏州万科环境工程有限公司 2014年2月(第一版) 操作和维护该系统时,必须遵守该手册中的操作程序。本手册仅针对本系统,如对其它水处理系统按照本手册操作引起损失,本公司恕不负责。 目录 1 人身安全注意事项.............................................................................................. 1.1电气................................................................................................................ 1.2机械................................................................................................................ 1.3开停机............................................................................................................ 1.4通道............................................................................................................... 1.5安全用具....................................................................................................... 1.6安全检查表................................................................................................... 2 废水处理工艺...................................................................................................... 3处理设备构筑物的运行与控制参数................................................................... 3.1地坑................................................................................................................ 3.2调节池............................................................................................................ 3.3气动隔膜泵.................................................................................................... 3.4管道混合器.................................................................................................... 3.5沉淀池............................................................................................................ 3.6回用水池........................................................................................................ 3.7除油过滤器.................................................................................................... 4加药系统............................................................................................................... 4.1加碱系统....................................................................................................... 4.2混凝剂加药系统........................................................................................... 4.3絮凝剂加药系统........................................................................................... 5. 压滤机系统........................................................................................................ 6. 触摸屏操作说明................................................................................................

风冷冷风型空调机安装使用说明书

目录 CATALOGUE 一、机组外观和机组结 构 (1) Unit outlook and structure 二、系统流程 图 (3) system flow chart 三、机组安 装 (4) Installation 四、调 试……………………………………………………………………………………………...…. .18 Test 五、使用 (20) Operation 六、维护和保

养 (25) Maintenance 七、运行范 围 (26) Run scope 八、简易故障处 理 (27) Trouble disposal 一、机组外观和机组结构Unit outlook and structure 1、机组外观

9 7 6 5 31 4 2 876543218 回风口 air inlet 出风口 air outlet 接水管排水孔 drain pan weep hole 室内外机连接口 indoor & outdoor unit connection 底盘排水孔 classic weep hole 电源线孔 power wire hole 压力表 pressure gauge 控制面板 control panel 室外机 outdoor unit 2、机组结构 Unit structure

6.电控箱 Electric controller 8.室外机 outdoor unit 5.风机 Fan 1.压缩机 Compressor 3.蒸发器 Evaporator 4.过滤网 Filter 9.球阀Ball valve 2.电加热 Electric heater 7.电机 Motor 3.气液分离器安装于室内机; Gas and liquide separation is installed in indoor unit. 以上三点示意图上均未表示. The three points above have not been shown in the sketch map. 2.热泵机使用膨胀阀节流,室内机室外机各安装一个; For heat-pump unit, expansion valve is used to throttle, installing each one both in indoor and outdoor units. 注: 1.单冷机使用毛细管节流(50HP以下); 二、系统流程图 system flow chart

串口调试软件使用说明2.0

串口调试软件使用说明 首先,运行该软件显示的是一个对话窗。在该界面的左上角有五个小的下拉窗口,分别为串口,波特率,校验位,数据位,停止位。 串口窗口应为仪表与计算机相连时所使用的串口。 波特率窗口选择仪表设置的波特率。校验位选择无。 数据位选择8位 停止位选择2位 在停止位的下面是显示区的选项,选择十六进制显示。 在整个界面的下方是发送区,主要选择十六进制发送,发送方式可选手动发送或自动发送。其中自动发送可设置发送周期(以毫秒为单位)。除直接发送代码外本软件也可直接发送文件。 仪表通讯协议如下: 通讯格式为8位数据,2个停止位,无校验位。 仪表读写方式如下: 读指令:Addr+80H Addr+80H 52H 要读参数的代号 写指令:Addr+80H Addr+80H 43H 要写参数的代号写入数低字节写入数高字节 读指令的CRC校验码为:52H+Addr 要读参数的代号,Addr为仪表地址参数值范围是0-100。 写指令的CRC校验码为:43H+要写的参数值+Addr 要写的参数代号。 无论是读还是写,仪表都返回以下数据: 测量值PV+给定值SV +输出值MV及报警状态+所读/写参数值 其中PV、SV及所读参数值均为整数格式,各占2个字节,MV占1个字节,报警状态占1个字节,共8个字节。 每2个8位数据代表一个16位整形数,低位字节在前,高位字节在后,各温度值采用补码表示,热电偶或热 电阻输入时其单位都是0.1℃,1V或0V等线性输入时,单位都是线性最小单位。因为传递的是16位二进制 数,所以无法表示小数点,要求用户在上位机处理。 上位机每向仪表发一个指令,仪表在0-0.2秒内作出应答,并返回一个数据,上位机也必须等仪表返回数 据后,才能发新的指令,否则将引起错误。如果仪表超过最大响应时间仍没有应答,则原因可能无效指 令、通讯线路故障,仪表没有开机,通讯地址不合等,此时上位机应重发指令。

反渗透设备操作说明书

反渗透设备操作说明书 目录 一、工艺简介 (2) 1、工艺流程简图 (2) 2、工艺说明 (2) 二、反渗透主机说明 (4) 三、设备启动 (5) 四、停机 (6) 五、注意事项 (6) 六、常见故障 (6) 七、产水量温度校正 (7) 7.1产水量的温度校正参数 (7) 7.1温度对产水量的影响 (7) 八、污染与清洗 (7) 8.1 清洗特别提示 (7) 8.2 膜污染 (7) 8.3 污垢成份 (10) 8.4 物理清洗 (11) 8.5 化学清洗 (14) 8.5.1 化学清洗药品的选择与使用 (14) 8.5.2 推荐的清洗药品 (15) 8.5.3 化学清洗系统 (19) 8.5.4 化学清洗过程 (21) 8.5.5 系统杀菌 (22) 8.5.6 清洗中物理手段与化学手段结合 (23) 一、工艺简介 1、工艺流程简图 原水à进水电动阀à原水箱à原水变频恒压供水系统à石英砂过滤器à活性炭过滤器à还原性杀菌剂添加à阻垢剂添加à保安过滤器à高压泵à反渗透膜组件à纯水箱à纯水变频供水系统à用水 2、工艺说明 进水电动阀 原水箱中设有液位控制系统,通过液位控制系统控制进水电动阀的开启与关闭,实现对原水箱的自动补水。 注意:当原水箱在补水过程中断电,需要操作人员手动关闭电动阀,否则在断电的情况下电动阀不能关闭会发生原水箱冒水事故。 原水箱 用于存储原水,对原水进行缓冲,平衡供水量与后续设备用水量。水箱设有补水液位控制、低水位液位控制,自动控制进水电动阀向原水箱补水,同时当进水电动阀或自来水供水出现故障而原水箱中水位低于液位控制浮球低位时,后续设备自动停止工作,当故障解决后水位高于低位浮球后设备自动转入工作状态。

国祥空调说明书

国祥空调说明书 国祥?空调说明书 ?篇一:? 国祥?风冷模块安装使用说明?书 ?篇二: ? 空调控制?板维修中央空调控制?维修关键词电子膨?胀阀故障检测及修理方?法富田螺杆机组配置?广州大麦空调控制器?格力中央空调外置电?子膨胀阀结构降膜螺?杆机组如何控制西?臣仕中央空调系统电?脑控制汇中地源热泵?空调说明书克莱门特?中央冷暖空调控制电路?sink空调空气?处理机组线路板海润?空调风冷模块机组安?装图纸水源热泵监控?系统枫叶能源空调水?机组故障代码热泵电?子膨胀阀故障聊城麦?克维尔地源热泵奇威?特中央空调空调电子?膨胀阀维修指引奇威?特控制器模块机通用?电路板电子膨胀阀接?线图电子膨胀阀原理?空调板式换热器冻坏?中央空调空调FER?D LIS 约克YCA?E-BC使用说明中?央空调通用控制器空?调风冷模块通用电脑板?蒋立天加天加?蒋立螺杆水冷空调液?晶线路板空调电路板?接线中央空调市场占?有率空调监控 GP?R S模块空调遥控器?维修中央空调压缩机?保养图片格力201?X上半年销售额富田?中央空调主板汇中中?央空调喷液压缩机?麦克维尔热泵控制板?伯瑞斯B-8空调天?津开利螺杆冷水机组?主板谷轮压缩机内?部结构天加空调蒋立?中央空调接线图空?调开关电源的原理欧?科中央空调简介麦克?维尔风冷模块机组报压?缩机过载电子膨胀阀?原理图中央空调PL?C系统中央空调因电?造成故障空调使用年?限规定电子膨胀阀门?的原理模块机万能控?制板伯瑞斯空调格?力201X年上半年销?售额约克空调机型?C00 2.MC?B.P:00 ? 3. 中央空调?电脑远程控制器空气?处理机组电路板地源?热泵空调品牌空调变?频通用板 carel?easytls编程?软件下载 eurkl?i mat 空

TD调试软件使用方法

TD调试软件使用方法 TDebug(文件名TD.EXE)是调试8086汇编语言的工具软件。TD主要用来调试可执行文件(.EXE文件)。它具有功能强、使用灵活方便、人-机界面友善、稳定可靠等特点,能提高工作效率,缩短调试周期。 1.启动方法 使用TDebug软件时,必须有以下文件: TD.EXE——可执行文件。 在DOS状态下键入TD即可启动TD软件。 例如: C:\SY86>TD 文件名 或 C:\SY86>TD F1-Help F2-Bkpt F3-Mod F4-Here F5-Zoom F6-Next F7-Trace F8-Step F9-Run 10-Menu 如果在键入TD之后又键入了文件名,则TD就将指定的文件装入以供调试;如果不指定文如果在键入TD之后又键入了文件名,则TD就将指定的文件装入以供调试;如果不指定文件名,则可以在TD的菜单操作方式下取出文件,然后进入调试状态。 2.窗口功能和操作 进入TD调试软件后,屏幕上出现五个窗口,系统现场信息分别显示在各窗口内。如上图所示。图中,第一行为菜单信息,最后一行为热键信息,中间即为

窗口信息。 窗口由五部分组成,利用Tab键可在各窗口之间进行切换。 ⑴CPU窗口: CPU窗口分别显示段地址寄存器cs、偏移地址、十六进制机器码和源程序代码。“?” 对应的偏移地址表示当前PC指针位置;用“↑”“↓”键移动光标可以使窗口上下卷动以便观察前、后的程序代码信息及地址信息; ⑵寄存器(Registers)窗口: 寄存器窗口显示所有寄存器信息。用“↑”“↓”键移动光标可以选中任一个寄存器。 选中寄存器后按数字键即会弹出一个窗口: 窗口提示输入数据。此时在光标位置处输入数字就改变了该寄存器的数值; ⑶标志窗口: 标志窗口显示各标志位的当前状态。用“↑”“↓”键移动光标选中某一标志后,按回车键即可改变该标志状态; ⑷堆栈窗口: 堆栈窗口显示堆栈寄存器ss的信息,包括堆栈偏移地址和堆栈数据。“?”对应的偏移地址表示当前堆栈指针位置;用“↑”“↓”键移动光标可以选择堆栈指针位置,然后按数字键即会弹出一个窗口: 窗口提示输入字数据。此时在光标处输入数字就改变了该偏移地址的数值; ⑸内存数据(Dump)窗口: Dump窗口分别显示数据寄存器ds、偏移地址、字节数据和ASCII代码。用“↑”“↓”“→”“←”键移动光标可以选择某一内存地址,然后按数字键会弹出一个窗口: 窗口提示输入一个字节数据。此时在光标处输入数字就改变了该内存地址的数值。 3.菜单操作与热键操作

麦克维尔中央空调室内控制器使用说明书

麦克维尔MAC风冷模块式冷水机组 控制面板操作说明 1 开关机 按ON/OFF键,机组在开机(RUN灯亮)、关机(RUN灯灭)之间切换。 2 模式选择 按“模式”键可在制冷/制热模式之间切换,须注意的是,模式切换必须在关机状态下进行,这样对压缩机能起到一定的保护作用。 3 参数查询 使用本控制器能查询它所联网的任意一台机组的工作状态及参数(有哪几台压缩机在工作、设定的进水温度、实际进水温度、设定的出水温度、实际出水温度、机组的定时设置、制冷防冻温度、冬季防冻温度、除霜温度等)。 按“机组”键后机组号码闪烁,此时按“▲”或“▼”键改变机组号,查看到的是不同机组的当前参数,若要查询某个机组的工作参数,找到欲查询的机组号时按“确定”键即可查询该机组的工作参数了,按“▲”或“▼”键查看该机组的不同的参数。 4 参数设置 按“机组”键后机组号码闪烁,此时按“▲”或“▼”键改变机组号,找到欲设置参数的机组号时按“确定”键即可设置该机组的工作参数了(可设置的参数有:制冷进水温度、制冷出水温度、制热进水温度、

制热出水温度、防冻温度、除露点A温度、除露点B温度、除霜温度)。 按“▲”或“▼”键选择要设置的参数,按“确定”键后就可以按“▲”或“▼”键设置参数值,设置完成后按“确定”键保存设置结果。 重复步骤②可设置其它参数。 5 实时时钟设置 用针形工具按“模式”键上方的小孔,液晶显示器上显示“星期设置”的字样,按“▲”或“▼”键设置当前时间是星期几,设置好了之后再按小孔,星期设置成功,同时显示器上显示“时钟设置”字样,时间会闪烁,此时按“▲”键修改小时,按“▼”键修改分钟,再按小孔即可保存设置的时钟。 6 定时设置 按“定时”键后显示器上同时显示“星期设置”和“定时设置”的字样,此时按“▲”或“▼”键选择要设置定时的时间在星期几,选好后按“确定”键,显示器上显示“定时设置”的字样,此时按“▲”键选择要设置当天的哪个定时(能设置4个,在“机组号”上方有指示),按“▼”键选择“定时开”或“定时关”,按“确定”键后再按“▲”键修改小时,按“▼”键修改分钟,设置好时间后按“确定”键保存这个定时设置。重复步骤①可设置其它的定时设置。如果想取消某一个定时设置,只需将它的定时时间设为上午0:00即可。 注意:定时开机和定时关机是以线控器上的时钟时间为准,如果时钟时间不准确,定时开机和定时关机的时间也将不准。在定时设置过程

(整理)微波调试软件使用说明

D O C N O.:M A001 VER:5.0.0.0 2007-11

目录 一、系统构成 (3) 二、安装与卸载 (3) 三、图示方法 (3) 1、红点 (3) 2、绿点 (3) 3、蓝点 (4) 4、坐标 (4) 四、操作说明 (4) 1、SYSTEM(系统) (4) 2、DATA(数据) (5) 3、PARAMETER SET(参数设置) (5) 4、OPERATION(操作) (6) 5、INFORMATION(工程信息) (8) 五、调试方法 (9) A、数据显示部分 (9) B、参数设置部分 (10) C、调试过程 (10)

一、系统构成 系统由一个EXE文件构成,打开系统时会自动建立Log和Project 目录。Log用于保存日志时的默认路径,Project用于保存工程文件 时的默认路径。 系统同时支持整体式和分体式的微波调试。 二、安装与卸载 本系统不需要安装,是绿色软件,直接复制MW Analyzer.exe即可。 卸载时直接删除MW Analyzer.exe和自动生成的Log和Project目录 即可。 三、图示方法 1、红点 红点是按F的当前值为横坐标,U的当前值为纵坐标画出的点,“” 表示最近一次红点的位置。 2、绿点 绿点是按F的平均值(30次)为横坐标,U的平均值(30次)为纵 坐标画出的点,“”表示最近一次绿点的位置。只有当F的当前值与 平均值之差小于5时才打印出绿点。

3、蓝点 在画板上单击左键即可,同时会把当前的坐标显示到OPERATION 中的X,Y中。也可以输入X,Y的值,点击画蓝点。 4、坐标 坐标是按F、U的真实值显示出来,默认的坐标范围是F:0430H-082FH,U:0640H-0A40H,如果显示的坐标不在此范围内时时,请单击按钮,系统自动按当前的F和U的值为中 心点输入到中,你也可以手动输入此值。设定好中心 点的值以后,单击按钮确认以后,系统即会重新设定起始坐标。 鼠标右键可以在当前位置上显示坐标虚线,便于查看坐标。 四、操作说明 1、SYSTEM(系统) OPEN(打开) CLOSE(关闭) EXIT(退出系统)

设备使用说明书

. 立式收口机 使 用 说 明 书 镇江市恒源汽车零部件有限公司

.

非常感谢您选择使用镇江市恒源汽车零部件有限公司生产的立式收口机,请详细阅读本品的使用说明书,以便于您的安全使用。 目录 1.安全说明 (3) 2.设备用途和适用范围 (7) 3.设备参数 (7) 4.设备动力系统 (8) 5.设备操纵系统 (12) 6.设备电气系统 (16) 7.设备冷却系统 (26) 8.设备运输、安装及试车 (27) 9.设备维护与保养 (29) 10.设备的结构及调整 (37) 11.设备易损零件及加工图 (38) 12.设备功能简介 (39)

1.安全说明 1.1安全规则概要 操作者使用设备前必须认真阅读安全说明,安全人员要确告操作者设备的要求。 1)设备的操作、维护和修理人员必须经过专业培训,有能力预见风险、有安全意识并能预测风险的人才能操作设备。 2)操作和维护人员必须认真阅读和掌握操作说明。 3)设备停止操作后,主油缸由于液压惯性还有短暂动作时间,应注意在工件停止前身体部位不得进入加工区域和触摸工件。 4)各种安全防护罩不得随意拆卸或改装,维护和修理时,应切断主电源。 5)设备上的各种安全警示标志不得随意拆卸,并要经常保持其干净、清晰。 警告:设备通电后,千万不要用手触摸模具和运动部件 6)设备的操作、维修和调整必须由专业人员进行,其他人员不得随意起动设备。 7)应按工艺规程操作设备,应由专业维修人员修理设备。 8)调整和维修设备时所用的扳手和钳子等工具必须是标准工具。 9)设备出现异常现象时应立即停机,并由专业维修人员及时检查和维修。 10)在拆卸和装配设备时,应使用有足够承载能力的起吊装置。 11)严格遵守设备上的安全说明和安全警告,并且确保其完整、清晰。 12)操作设备前要进行安全检查,确定各行程及限位开关、撞块、急停按钮、光栅安全可靠。 13)维修或调整设备前一定要在开关关闭、电源切断、工件完全停止的状态下进行。 14)操作人员不要穿宽松的衣服、袖口必须扎紧,不要戴领带、珠宝(戒指、手表等),必须戴护目镜和穿劳保鞋。 15)操作设备时,不论男女,长发必须戴工作帽并将其包裹在内。 16)整机噪音不大于75dB。建议穿戴适当的劳保用品,例如,戴听力保护器以减少听力的损失。 17)设备周围工作区要保持干净、明亮整洁、光线适宜,附近不能放置杂物,以免给操作者带来不便。 18)设备运行、加工时,不许移动各处防护罩。 19)离开设备时,必须关闭设备主电源开关。 20)设备重新起动时,必须对设备进行重新复位。 21)设备上,特别是设备的运动部件周围不能放置工件、工具等物件。 22)主油缸动作前一定要将工件(工装)固定牢靠,人员离开工作区域后才可起动设备。