阀门样本

一、调节阀系列First、series regulating valve 1、型号编制说明The model description: P普通型M密闭型 P Normal type M Airtight type D电动Q气动S手动 D Motor-driven Q Pneumatic S Manual 风阀高度H Air valve height H 风阀宽度W Air valve widthW 1 工作温度为-40℃~95℃2工作温度为 -55℃~205℃ 1 the operating temperature -40℃~95℃ 2 the operating temperature55℃~205℃ D对开式P平行式 D Vis-a-vis type P Parallel type 创元风量调节阀 chuangyuan air volume regulating valve 1.1、型号示例model sample1: CYTD2-1000×500SP 表示创元普通型对开式多叶调节阀,工作温度为-55℃~205℃,宽1000mm,高500mm CYTD2-1000×500SP is Chuangyuan normal vis-a-vis multi-blade regulating valve, the working temperature is -55℃~ 205℃, width is 1000mm, the height is 500mm 2、风量调节阀技术参数Air volume regulating valve technical parameters: 2.1、风量调节阀框体和叶片采用镀锌钢板制成,无焊点,表面无需涂装; Air volume regulating valve frame and blade made by galvanized steel plates, no weld, the surface doesn’t need paint. 2.2、风阀轴承材料为烧结青铜含油轴承,可以耐300℃的高温; The regulating valve bearing material is sintered bronze oiled bearings, can resist high temperature 300℃; 2.3、叶片由10×10方形轴连接,轴的材料为45#镀锌钢; Blades are connected by 10×10 square shaft, the material of the bearing is 45# galvanized steel plates 2.4、根据需要可选配可调节风量的执行机构; We can provide implement facility which can regulating the air volume by need.

调节阀知识培训试题

控制阀知识培训试题 一、填空题 1、一个简单的控制系统是由检测元件和变送器、调节器 和控制阀(亦称调节阀)基本组成。 2、控制阀由执行机构和阀部分组成。 3、控制阀按驱动方式可分为气动控制阀,电动控制阀和液动控 制阀。 4、控制阀按动作方式分类有直行程控制阀和角行程控制阀。 5、控制阀按调节方式分类有调节型、切断型和调节切断型。 6、气动控制阀按作用方式分类有气关式和气开式 7、气动执行机构按结构分为气动薄膜式执行机构和气动活塞 式执行机构。 8、气动执行机构按输出方式分为直行程气动执行机构和角行 程气动执行机构。 9、阀部分与介质直接接触,在执行机构的推动下,改变阀芯与 阀座之间的流通面积,从而达到调节流量的目的。 10、控制阀的固有流量特性有直线特性、等百分比(或抛物线) 特性和快开特性。

11、控制阀常用的附件有:阀门定位器、电磁阀、空气过滤减压 阀、手轮机构、限位开关、电气转换器、气动保位阀等。 12、12、电-气阀门定位器常用的防爆等级有:本安型(如 ExiaIIBT6、ExibIICT5)、隔爆型(如ExdIIBT5)。 二、问答题: 1、执行机构按其使用的能源分哪几种不同的执行机构?气动薄膜 执行机构按动作方式可分哪两种? 答:有气动执行机构,电动执行机构,液(电) 执行机构. 气动薄膜执行机构按动作方式可分:正作用和反作两种. 2、控制阀基本类型有哪些?(写出10种即可) 答:(也可参看样本) 如:a、直行程调节阀:单座阀,双座阀,笼式阀,三通(合流/分流)阀, 角形阀, 波纹管密封阀,小流量调节阀,保温夹套阀,低噪 音笼阀, 低温单座/双座阀,衬氟(F4或F46) 单座阀, 闸板 阀,隔膜阀,自力式调节阀等; b、角行程调节阀:“O”型球阀,“V”型球阀, 蝶阀, 偏心旋 转阀等。 3、什么是控制阀的额定流量系数?请写出三个不同单位制的 额定流量系数符号,并写出相互换算关系? 答: 控制阀的额定流量系数是指阀全开时,单位时间内通过阀(门)

流量调节阀的工作原理以及选型

流量调节阀的工作原理以及选型 计量收费主要通过三个途径宏观节能:首先是装设了流量调节阀,实现了流量平衡,进而克服了冷热不均现象;其次是通过温控阀的作用,利用了太阳能、家电、照明等设备的自由热;第三是提高了用热居民的节能意识,减少了开窗户等的无谓散热。而这三条节能途径,其中有二条都是通过流量调节阀来实现的。可见,流量调节阀,在计量收费的供热系统中,占有何等重要的地位。因此,如何正确的进行流量调节阀的选型设计,就显得非常重要。 一、温控阀阀 1、散热器温控阀的构造及工作原理 用户室内的温度控制是通过散热器恒温控制阀来实现的。散热器恒温控制阀是由恒温控制器、流量调节阀以及一对连接件组成,其中恒温控制器的核心部件是传感器单元,即温包。温包可以感应周围环境温度的变化而产生体积变化,带动调节阀阀芯产生位移,进而调节散热器的水量来改变散热器的散热量。恒温阀设定温度可以人为调节,恒温阀会按设定要求自动控制和调节散热器的水量,从而来达到控制室内温度的目的。温控阀一般是装在散热器前,通过自动调节流量,实现居民需要的室温。温控阀有二通温控阀和三通温控阀之分。三通温控阀主要用于带有跨越管的单管系统,其分流系数可以在0~100%的范围内变动,流量调节余地大,但价格比较贵,结构较复杂。二通温控阀有的用于双管系统,有的用于单管系统。用于双管系统的二通温控阀阻力较大;用于单管系统的阻力较小。温控阀的感温包与阀体一般组装成一个整体,感温包本身即是现场室内温度传感器。如果需要,可以采用远程温度传感器;远程温度传感器置于要求控温的房间,阀阀体置于供暖系统上的某一部位。 2、温控阀的选型设计 温控阀是供暖系统流量调节的最主要的调节设备,其他调节阀都是辅助设备,因此温控阀是必备的。一个供暖系统如果不设置温控阀就不能称之谓热计量收费系统。在温控阀的设计中,正确选型十分重要。温控阀的选型目的,是根据设计流量(已知热负荷下),允许阻力降确定KV值(流量系数);然后由KV值确定温控阀的直径(型号)。因此,设计图册或厂家样本一定要给出KV值与直径的关系,否则不便于设计人员使用。 在温控阀的选型设计中,绝不是简单挑选与管道同口径的温控阀即完事大吉。而是要在选型的过程中,给选定的温控阀造成一个理想的压差工作条件。一个温控阀通常的工作压差在2~3mH2O之间,最大不超过6~10mH2O。为此,一定要给出温控阀的预设定值的范围,以防止产生噪音,影响温控阀正常工作。当在同一K V值下,有二种以上口径的选择时,应优先选择口径小的温控阀,其目的是为了提

电子式电动调节阀

一、产品[电子式电动套筒调节阀]的详细资料: 产品型号:ZDSM型 产品名称:电子式电动套筒调节阀 产品特点:ZDSM系列直行程电动套筒调节阀,由套筒阀配用德国进口PS系列电动执行机构组成。电动执行机构内有伺服系统,无需另配伺服放大器,有输入控制信号(4-20mADC或1-5VDC)和单相电源即可控制运转,实现对压力、流量、温度、液位等参数的调节。采用平衡式阀塞结构,具有阀塞稳定性好、不易产生震动、噪声低敏感性小、允许使用压差大、连线简单等特点,广泛用于流量系数大,泄漏量要求比较严的电力、冶金、石油、化工、轻工等行业的工业自动控制系统中。 二、阀体: 形式:直通套筒铸造阀 公称通径:25-300mm 公称压力:PM1.6 4.0 6.4MPa 连接形式:法兰式按JB78-59 JB79-59 材料:HT200 ZG230—450 ZG1Cr18Ni9Ti ZG0Cr18Ni12Mo2Ti 三、上阀盖: 常温型:-20℃-+200℃ 散热型:-40℃-+450℃ 压盖形式:螺栓压紧式

填料:V型聚四氟乙烯填料、柔性石墨、不锈钢波纹管 四、阀内组织: 阀芯形式:上导向单座套筒或双座套筒柱塞型阀芯 流量特性:等百分比特性,线性特性和快开特性 1Cr18Ni9Ti 0Cr18Ni12Mo2Ti 材料: 五、执行机构: 类型:可选PS、3810、ZAZ型(DN100以内)、DKZ型(DN100以上)系列电子式直行程执行机构。防爆型选用3810系列技术参数和性能:请参阅对应的执行机构与阀门定位器说明书。

六、ZDSM型电动套筒调节阀规格参数表: 七、安装尺寸:

调节阀调校记录表

SH/T3543-G603调节阀调校记录工程名称:单元名称: 仪表名称仪表型号仪表位号制造厂精确度出厂编号行程允许误差输入信号 规格 PN= DN= d i= 作用形式 标准表名称/编号/精度 阀门定位器 型号作用方向 气源 MPa 输入输出 阀体强度试验试验介质试验压力 MPa 5min压力降 kPa 膜头气密性试验试验介质试验压力 MPa 5min压力降 kPa 阀芯、阀座泄漏量试验试验介质 阀门出入 口压差 MPa 实测值 ml/min 允许值 ml/min 全行程时间,s开阀关阀 被校刻度 带阀门定位器不带阀门定位器050%100%0%50%100% 输入信号()标准行程() 实测行程()正反 误差()正反 回差()备注: 结论: 调校人: 日期: 年月日专业工程师: 日期:年月日 质量检查员: 日期:年月日

气动薄膜调节阀校验记录 准考证号: 仪表名称* 仪表型号* 制造厂* 行程* 调节阀基 本误差±5% 带定位器 基本误差 ±1% 阀门输入信号0.08-0.24MPa 流量特性* 作用方式* 额定CV值* 阀体材质* 出厂编号* 规格PN= * DN= * 标准表名称 阀门定位器型号* 作用方式正作用 气源* 输入输出 电磁阀型号* 额定电压* 膜头气密性 试验 试验介质试验压力MPa 分钟下降 气密性 试验结论 将5分钟压降值与标准值(2.5kPa)比较,判断是否合格。 被校刻度(%)不带阀门定位器带阀门定位器 输入信号 (MPa /mA ) 标准行程 (mm) 实测行程(mm)正反 实测误差(mm)正反 死区测试点(%)正(mA)反(mA)区(%) 校验结论1、测量误差判断: ①不带定位器:计算最大实际误差值,判断实际误差值是否超出允许误差范围(±5%)。判断是否合格。 ②带定位器:计算最大实际误差值,判断实际误差值是否超出允许范围(±1%)。判断是否合格。 2、死区判断:将三点死区值中的最大值与死区标准(0.6%)比对,判断死区值是否超出允许值范围。(只要操作步骤正确,判断正确就可以。因为定位器有时会出现死区超差的现象。) 注:1、校验记录中的“ * ”代表铭牌中的信息。按铭牌填写即可。空白区域为选手填写。红色字体为相关的提示信息也要选手填写。 2、实测误差计算,用(实测行程-标准行程)。然后将mm值写出。在校验结论中取实测误差最大值进行计算。

各种流量调节阀的工作原理及正确选型

各种流量调节阀的工作原理及正确选型

各种流量调节阀的工作原理及正确选型 计量收费主要通过三个途径宏观节能:首先是装设了流量调节阀,实现了流量平衡,进而克服了冷热不均现象;其次是通过温控阀的作用,利用了太阳能、家电、照明等设备的自由热;第三是提高了用热居民的节能意识,减少了开窗户等的无谓散热。而这三条节能途径,其中有二条都是通过流量调节阀来实现的。可见,流量调节阀,在计量收费的供热系统中,占有何等重要的地位。因此,如何正确的进行流量调节阀的选型设计,就显得非常重要。 一、温控阀 1、散热器温控阀的构造及工作原理 用户室内的温度控制是通过散热器恒温控制阀来实现的。散热器恒温控制阀是由恒温控制器、流量调节阀以及一对连接件组成,其中恒温控制器的核心部件是传感器单元,即温包。温包可以感应周围环境温度的变化而产生体积变化,带动调节阀阀芯产生位移,进而调节散热器的水量来改变散热器的散热量。恒温阀设定温度可以人为调节,恒温阀会按设定要求自动控制和调节散热器的水量,从而来达到控制室内温度的目的。温控阀一般是装在散热器前,通过自动调节流量,实现居民需要的室温。温控阀有二通温控阀和三通温控阀之分。三通温控阀主要用于带有跨越管的单管系统,其分流系数可以在0~

100%的范围内变动,流量调节余地大,但价格比较贵,结构较复杂。二通温控阀有的用于双管系统,有的用于单管系统。用于双管系统的二通温控阀阻力较大;用于单管系统的阻力较小。温控阀的感温包与阀体一般组装成一个整体,感温包本身即是现场室内温度传感器。如果需要,可以采用远程温度传感器;远程温度传感器置于要求控温的房间,阀体置于供暖系统上的某一部位。 2、温控阀的选型设计 温控阀是供暖系统流量调节的最主要的调节设备,其他调节阀都是辅助设备,因此温控阀是必备的。一个供暖系统如果不设置温控阀就不能称之谓热计量收费系统。在温控阀的设计中,正确选型十分重要。温控阀的选型目的,是根据设计流量(已知热负荷下),允许阻力降确定KV值(流量系数);然后由KV值确定温控阀的直径(型号)。因此,设计图册或厂家样本一定要给出KV值与直径的关系,否则不便于设计人员使用。 在温控阀的选型设计中,绝不是简单挑选与管道同口径的温控阀即完事大吉。而是要在选型的过程中,给选定的温控阀造成一个理想的压差工作条件。一个温控阀通常的工作压差在2~3mH2O之间,最大不超过6~10 mH2O。为此,一定要给出温控阀的预设定值的范围,以防止产生噪音,影响温控阀正常工作。当在同一KV值下,

调节阀技术规范书.(DOC)

福建华电泉惠石化工业区2×30t/h 应急供热项目工程 调节阀技术规范书

批准:审核:校核:编写:

目录 第一部分技术规范 (2) 第二部分技术资料和交付进度 (17) 第三部分设备监造(检验)和性能验收试验 (16)

第一部分技术规范 1 总则 1.1 本技术规范书适用于福建华电泉惠石化工业区2×30t/h应急供热项目工程的国产调节阀门,包括阀门本体、电动装置及其附件的功能设计、性能、结构、制造、试验、安装和质量保证等各方面的技术要求。 1.2 本规范书提出的是最低限度的技术要求,并未对一切技术要求作出详细规定,也未充分引述有关标准和规范的条文,投标方应保证提供符合本规范书和相关的国际国内工业标准的优质产品。 1.3 如投标方有除本规范以外的其他要求,应以书面形式提出,经投标方、招标方双方讨论后载于本规范书。 1.4 投标方对调节阀整套设备(包括辅助系统和设备)负有全责,即包括分包(或采购)的产品。分包(或采购)的产品制造商应事先征得招标方的认可。 1.5 本规范书所使用的标准若与投标方执行的标准发生矛盾时,按较严格的标准执行。 1.6 如投标方没有对本规范书提出书面异议,招标方则可认为投标方提供的产品完全满足本规范书的要求。投标方如对本招标文件有偏差(无论多少或微小)都必须清楚地表示在本规范书的附件“差异表”中。 1.7 本规范书经投标方、招标方双方共同确认和签字后作为订货合同的附件,与订货合同正文具有同等效力。未尽事宜由双方协商解决。 1.8 在合同签订后,招标方有权因规范、标准、规程发生变化而提出一些补充要求,具体内容双方共同商定。 2 工程概况 2.1 设备使用条件 2.1.1设备安装位置:室内布置。

气动调节阀检修规程样本

1 目的 为了加强调节阀的维护保养和检修质量, 使调节阀能长寿命、稳定实现调节作用, 特制定本规程。 2 适用范围 适用于公司中用于生产过程自动控制的由气动薄膜执行机构和阀体组成的气动调节阀, 包括一般的单座阀、双座阀、套筒阀等的维护、保养、检修。 3 调节阀的概念 调节阀是自控系统中的终端现场调节仪表。它安装在工艺管道上, 调节被调介质的流量、压力, 按设定要求控制工艺参数。调节阀直接接触高温、高压、深冷、强腐蚀、高粘度、易结晶结焦、有毒等工艺流体介质, 因而是最容易被腐蚀、冲蚀、气蚀、老化、损坏的仪表, 往往给生产过程的控制造成困难。因此, 必须充分重视调节阀的运行维护和检修工作。 4 运行维护 4.1 调节阀运行 4.1.1 调节阀在投入运行前需做系统联校。

4.1.2 调节阀在工作时, 前后的切断阀应全开, 旁路阀( 副线阀) 应全关。整个管路系统中的其它阀门应尽量开大, 一般调节阀应在正常使用范围( 20%—80%) 内工作。 4.1.3 使用带手轮的调节阀应注意手轮位置指示标记。 4.1.4 调节阀在运行过程中严禁调整阀杆和压缩弹簧的位置。 4.2 日常巡检 4.2.1 巡检时应检查各调节阀的气源压力是否正常、气路( 仪表空气管经过滤减压阀、阀门定位器至气缸各部件、各管线) 的紧固件是否松动、仪表空气是否有泄漏。 4.2.2 巡检时应检查填料函及法兰连接处是否有工艺介质泄漏, 压兰及阀杆连接件是否紧固, 阀杆是否有严重的摩擦划痕或变形。 4.2.3 巡检时需检查仪表线路的防护情况, 仪表进线口密封是 否良好。 4.2.4 巡检时应检查阀杆运动是否平稳, 行程与输出信号是否 基本对应, 阀门各部件有无锈蚀, 重点是阀杆、紧固件、气缸等。 4.3 专项检查

Copes Vulcan 控制阀样本

GS General Service Control Valves

GS-General Service Valves The GS-General Service Valves continue Copes-Vulcan’s tradition of designing and manufacturing control valves that provide both exceptional service and great value. Representing significant refinement in design and performance for general service globe style control valves, the GS-General Service Valves combine the most advanced levels of body configuration, trims and actuation to produce a valve assembly capable of premium performance at a competitive price. Suitable for controlling water, steam, gas and most other fluids, GS-General Service Valves deliver a new standard of versatility, rugged dependability and cost effectiveness that will serve the power and process industries well into the 21 st century. Copes-Vulcan GS-General Service Valves are ideally suited for non-severe flow control of most liquids, steam and gases. They provide reliable, economical performance in heater drains, gas and fuel oil control, feedwater control, steam/gas pressure reduction and many other power and process flow control operations.For applications involving extreme environments, especially hostile fluids, or pressure classes greater than ANSI 600, specify Copes-Vulcan SD-Severe Duty Control Valves. 2

FLOWTOP调节阀样本

TECHNICAL BULLETIN Valtek FlowTop Control Valve FCD VLENTB0060 – 11/09 (Replaces FCD-VLATB060) Experience In Motion

2 Body Assembly Figure 1: FlowTop Control Valve Body Assembly The FlowTop control valve is a high-performance, general service valve coupled with the high thrust FlowAct pneumatic diaphragm actuator. The Logix 500 positioner is mounted standard on FlowTop control valves. The Logix 500 simplifies and reduces calibration time to 20 seconds or less by pushing two buttons. The easily installed HART compatible positioner make the FlowTop/Logix 500 combination the best choice for general service valve applications. There is no need for additional software or software support and upgrades. Handheld devices are not needed to calibrate this valve, making it the highest performing, low cost solution for general service valves. The Pop-belly shaped gallery give the FlowTop more C than all the other globe valves on the market. Designed for use in ANSI Class 150 or 300 service applications, the FlowTop control valve is capable of operating within temperatures ranging from -500 to 8000 F (-460 to 4270 C). The FlowTop control valve is available in sizes 0.5 to 4 inches with a carbon steel or stainless steel body. It features flow under, single seated trim with a post-guided valve stem to eliminate cage guiding problems. Heavy duty parts constructed of corrosion resistant materials provide extended valve life. Zero external leakage at the body to Graphite gasket eliminates leakage and minimizes torque requirements. Multiple equally spaced body bolts ensure optimal Stable plug travel over entire stroke of Solid, sturdy post style guide minimizes vibration and wear. Very low seat leakage: A solid graphite seat gasket provides excellent shut-off. No lapping or grinding required to achieve class 4 shut-off. No more messy lapping values available per valve No need to lap the plug and seat systems available: UltraGuard packing, which requirements. up to 5 years; required (see Figure 18) Highest globe valve C v ’s on the market: The pop belly shaped gallery enables flowTop to have higher C trim size, and valve size than all other globe valves on the market.

如何正确的进行流量调节阀的选型设计

如何正确的进行流量调节阀的选型设计 计量收费主要通过三个途径宏观节能:首先是装设了流量调节阀,实现了流量平衡,进而克服了冷热不均现象;其次是通过温控阀的作用,利用了太阳能、家电、照明等设备的自由热;第三是提高了用热居民的节能意识,减少了开窗户等的无谓散热。而这三条节能途径,其中有二条都是通过流量调节阀来实现的。可见,流量调节阀,在计量收费的供热系统中,占有何等重要的地位。因此,如何正确的进行流量调节阀的选型设计,就显得非常重要。 一、温控阀阀 1、散热器温控阀的构造及工作原理 用户室内的温度控制是通过散热器恒温控制阀来实现的。散热器恒温控制阀是由恒温控制器、流量调节阀以及一对连接件组成,其中恒温控制器的核心部件是传感器单元,即温包。温包可以感应周围环境温度的变化而产生体积变化,带动调节阀阀芯产生位移,进而调节散热器的水量来改变散热器的散热量。恒温阀设定温度可以人为调节,恒温阀会按设定要求自动控制和调节散热器的水量,从而来达到控制室内温度的目的。温控阀一般是装在散热器前,通过自动调节流量,实现居民需要的室温。温控阀有二通温控阀和三通温控阀之分。三通温控阀主要用于带有跨越管的单管系统,其分流系数可以在0~100%的范围内变动,流量调节余地大,但价格比较贵,结构较复杂。二通温控阀有的用于双管系统,有的用于单管系统。用于双管系统的二通温控阀阻力较大;用于单管系统的阻力较小。温控阀的感温包与阀体一般组装成一个整体,感温包本身即是现场室内温度传感器。如果需要,可以采用远程温度传感器;远程温度传感器置于要求控温的房间,阀阀体置于供暖系统上的某一部位。 2、温控阀的选型设计 温控阀是供暖系统流量调节的最主要的调节设备,其他调节阀都是辅助设备,因此温控阀是必备的。一个供暖系统如果不设置温控阀就不能称之谓热计量收费系统。在温控阀的设计中,正确选型十分重要。温控阀的选型目的,是根据设计流量(已知热负荷下),允许阻力降确定KV值(流量系数);然后由KV值确定温控阀的直径(型号)。因此,设计图册或厂家样本一定要给出KV值与直径的关系,否则不便于设计人员使用。

Fisher调节阀中文规格书参照

Sliding Stem Valve Specification Customer: Star Controls Engineering Co Pte Ltd Contact: Contact: Hardy Zhu Customer Reference: Sales Office Reference: Lead Time: 序号: 1 Rev: Qty: 1 Quote: Rev: 位号: Date Last Modified: 01/04/2013 描述: NPS 1 EZ Origin Cert PL 667 Size 30 DVC6200 SS ATEX Compliance -N.A. Process Level 3 位置: 定位器型号: DVC6200,Performance-PD 尺寸及型号: NPS 1 EZ 输入信号: 4 to 20 mA dc 阀门形式: Globe 附件: 67CFR Filter/Regulator 设计温度: 104 deg C 压力表: 0-60 psig/0-0.4 mPa 设计压力: 4.3 MPa(g) 作用形式: Direct 端部连接: CL600 RF 防爆证书: Ex iaII CT4,IP65 材质: WCC Steel Controller Type: 阀门口径: 1 Action: 流向: Up Measure Element: 阀芯号: 101 Range: 阀笼材质: Output: 阀座保持环: CB7Cu-1 SST Mounting: 轴套材质: S17400 SST Airset: 阀座材质: S41600 SST Mounting: 阀塞 : Transducer: 材质: S41600 SST Input Signal: 导向套: Post Output Signal: 是否平衡: Unbalanced Action: 关断等级: ANSI CL IV Mounting: 通径: 1/2 Inch Airset: 流量特性: Micro-Form Certifications: 阀杆材质: S31600 SST 管道入口尺寸: 2 in, SCH STD 阀杆尺寸: 3/8 Inch 管道出口尺寸: 2 in, SCH STD 阀盖形式: Plain 保温: 执行机构支架连接面尺寸: 2 1/8 工况: 填料: Single PTFE 介质: Water 附件: No 饱和蒸汽压: 螺栓螺母: SA-193-B7 Studs/2H Nuts 关断压降: 填料压盖: SST Pkg Flg, SST Studs & Nuts 执行机构: Spring & Diaphragm 型号/尺寸: 667/30 行程: 3/4 Inch 弹簧压缩系数: 16-30 psi 作用形式: PDTC 供给: Air 膜头气源压力: 0 to 33 psig 失气形式: Close 手轮: Top Mounted Handwheel Max Rated Cv: 4.91 Variable Name 参数名称 Unit 单位Normal Maximum Mass flow rate Liquid (wl) 流量kg/h 2061.2600 3435.4300 Inlet Pressure (P1) 进口压力MPa(g) 4.300000 4.300000 Pressure Change (dP) 压降kPa 664.600 281.700 Temperature (T1) 温度deg C 104.0000 104.0000 SG 比重0.958 0.958 Kinematic Viscosity (Nu) 粘度cSt 0.283 0.283 Vapor Pressure (Pv) 饱和蒸汽压psia 16.937 16.937 Sizing Coefficient (Cv) Cv值0.946 2.428 % Open 开度46.12 73.54 NOTES: 备注

自力式压力调节阀说明书

第一节 ZZY型自力式压力调节阀 1.前言 ZY型自力式压力调节阀(简称调压阀)无需外加能源,利用被调介质自身能量为动力源,引入执行机构控制阀芯位置,改变两端的压差和流量,使阀前(或阀后)压力稳定。具有动作灵敏,密封性好,压力设定点波动小等优点,广泛使用于石油、化工、电力、冶金、食品、轻纺、机械制造和居民建筑楼群等到各种工业设备中用气体、液体及蒸汽介质减压稳压或泄压稳压的自动控制。能在无电、无气的场合使用,附设冷凝器,可在350℃蒸汽下连续工作。 2.原理: 2.1用于控制阀后压力的调压阀,阀的作用方式为压闭型。介质由阀前流入阀体,经阀芯、阀座节流后输出。另一路经导压管、冷凝器(介质为蒸汽时使用)冷却后,被引入执行机构作用于膜片有效面积上,产生一个向下作用力,压缩弹簧,推动阀杆,带动阀芯位移,改变流通面积。达到减压、稳压之目的。如阀后压力增加,作用于膜片有效面积上的力增加,压缩弹簧,带动阀芯,使阀门开启度减小,直至阀后压力下降到设定值为止。同理,如阀后压力降低,作用在膜片有效面积上的力减小,在弹簧的弹力作用下,带动阀芯,使阀门开启度增大,直到阀后压力上升到设定值为止。(例图一)启到减压稳压作用 (图一)蒸汽用控制阀后型自力式压力调节阀 B型 (图二)控制阀前压力的调压阀K型2.1用于控制阀前压力的调压阀,阀的作用方式为压开型。介质由阀前流入阀体,同时经导压管、冷凝器(介质为蒸汽时使用)冷却后,被引入执行机构作用于膜片有效面积上,压缩弹簧,使阀芯随之发生相应的位移,达到泄压、稳压之目的。如阀前压力增加,

作用于膜片有效面积上的力增加,压缩弹簧,带动阀芯,使阀门开启度增大,直至阀前压力下降到设定值为止。同理,如阀前压力降低,作用在膜片有效面积上的力减小,在弹簧的弹力作用下,带动阀芯,使阀门开启度减小,直到阀前压力上升到设定值为止。(图二)启到泄压稳压的作用 一般来说压开型的自力式压力调节阀工作时为常闭,超过压力设定点时打开 启到安全作用,但又于安全阀有所区别,安全阀是超过压力设定点阀门全开,而自力式压开型是随着压力的升高开度相应增大。 3. 规格和技术参数: 3.1公称通径:DN15~350 3.2公称压力:PN16、40、64 3.3流量特性:快开 3.4性能指标:符合Q/SF.J02.01.04-1997 3.5结构型式:单座、双座、套筒(无压开型) 单座时平衡:1.常规型波纹管(受耐压限制);2.活塞式(受温度限制) 双座、套筒(两密封面来平衡) 平衡效果没有单座阀好。 3.6执行机构类型:簿膜式、活塞式、波纹管式 3.6.1.薄膜式;压力≤0.6Mpa(70、120、200、280、400、600) 3.6.2.气缸式;压力较高(50、55、60、65、70、75、80、85、90、95、100、105、110、 115、120、130、160) 3.6.3波纹管;高温或特殊介质(导热油,氧气,氢气等) 35、47.2、104、230、70.8, 注为优选系列 3.7压力调节范围(KPa):15~2000内分段(调节范围不宜过大,过大可能导致弹簧刚度 增大,直接影响调节精度。)参考选型样本。控制压力尽量选取在调节范围的中间值附近。 3.8调节精度:±5%~10%(执行机构和弹簧刚度有关)(特殊的调节精度需协商) 例:ZZYP-16B DN50 阀门行程为14mm, 设定压力为1Kg ,选400CM的执行机构,用组合弹簧刚度4kg/mm, 此时的调节精度为: [(4*15)/400]/1*100%=14% 全行程所需要的推力 3.9调压比:10:1~10:8(阀前压力:阀后压力)压差过高时压力不宜稳定,噪声大, 压差不宜过小,因为阀本身有一定的压力损失。 选型注意:(1).DN20~50(弹簧最大压紧力650Kg);DN65~100(弹簧最大压紧力850Kg)最大紧压力:最大设定压力(kg/ cm2×执行机构有效面积cm2) (2).在深冷的场合使用时执行机构和导压管弹簧均采用不锈钢,执行机构用波 纹管 (3)自力式压力调节阀适用于压力粗调的场合,如果压力波动范围较大,且流