Agilent HDNS-2100
Solid-State Optical Mouse Lens
Data Sheet
Description
The HDNS-2100 Solid-State Optical Mouse Lens is designed for use with Agilent Optical Mouse Sensors and the illumination subsystem provided by the HDNS-2200 or HDNS-2200#001 LED Assembly Clip and the HLMP-ED80 LED. Together with the LED, the HDNS-2100 provides
Ordering Information
Specify Part Number as follows:Minimum order quantity of 1000.
Flange
Part Number Round
HDNS-2100Rectangular
HDNS-2100 #001
Outline Drawings HDNS-2100
HDNS-2100 #001
6.00 (0.236)
7.87 (0.310)
8.00 (0.315)
OPTICAL AXIS
2.00 (0.079)
14.53 (0.572)
10.45 (0.411)
1.15 (0.045)
9.85 (0.388)
5.05 (0.199)
1.30 (0.051)
42.00 ± 0.1 mm (1.654 ± 0.0039)
?39.50 ± 0.1 mm (1.555 ± 0.0039)
1.00 (0.039)
6.00 (0.236)
7.87 (0.310)8.00
(0.315)
0.50 (0.020)16.00 (0.630)
8.00 (0.315)
13.00 (0.512)
30.50 (1.201)
R 4 PLACES
14.53 (0.572)
OPTICAL AXIS
10.45 (0.411)
1.15 (0.045)
5.05 (0.199)
1.30 (0.051)
2.30 (0.091)
1.00 (0.037)
the directed illumination and optical imaging necessary for proper operation of the Optical Mouse Sensor. The HDNS-2100 is a precision molded optical component and should be handled with care to avoid
scratching of the optical surfaces.
NOTES:
1. DIMENSIONS IN MILLIMETERS (INCHES).
2. TOLERANCE IS ± 0.2 mm (± 0.0079 IN.) EXCEPT WHERE NOTED.
3. THERE IS ALSO A FLASH TOLERANCE OF –0, +0.2 mm ON THE FLANGE.
https://www.sodocs.net/doc/0716034694.html, Data subject to change.
Copyright ? 2001 Agilent Technologies, Inc.April 25, 2001
Obsoletes 5988-2271EN 5988-2835EN
Mounting Instructions for the
HDNS-2100 Lens to the Base Plate An IGES format drawing file with design specifications for mouse base plate features is available.These features are useful in maintaining proper positioning and alignment of the HDNS-2100when used with the Agilent Optical Mouse Sensor. This file can be obtained by contacting your local sales representative.
Mechanical Assembly Requirements
All specifications reference Figure 2, Optical System Assembly Diagram.
* Lens material is polycarbonate. Cyanoacrylate based adhesives should not be used as they will cause lens material deformation.
Symbol Min.Typical Max.Units Conditions
Distance from Object Surface to
A 2.3
2.4 2.5
mm Lens Reference Plane
Distance from Mouse Sensor Lid B 7.45mm Sensor lid must be in contact Surface to Object Surface
with lens housing surface Lateral Distance from Center of
C
0.20mm
Aperture stop should self-Aperture Stop to Center of Lens Surface
center on lens
Figure 2. Optical system assembly diagram.Lens Design Optical Performance Specifications
All specifications are based on the Mechanical Assembly Requirements.
Symbol
Min.Typical Max.Units
Conditions
Numerical Aperture NA
0.10.130.16Magnification 0.85
1.00 1.15
Image at nominal location
Design Wavelength λ
639nm Object to Image Distance 8.7358.8238.911mm Lens Material* Index of Refraction N 1.5800
1.5818 1.5840
λ = 639 nm
Depth of Field DOF ± 0.5mm Field Coverage Radius
1.00
mm
Figure 4. Illustration of base plate mounting features.
Figure 3. Logo locations.
LENS RECESS DIMENSIONS: HDNS-2100 43.0 mm DIA. HDNS-2100 #001 31.5 x 17.0 mm
1. TOPSIDE LOGO EXTENDS 0.2 mm ABOVE THE FLANGE SURFACE.
2. BOTTOMSIDE LOGO EXTENDS 0.1 mm BELOW THE SURFACE.
3. BOTTOMSIDE LOGO IS EITHER LEFT SIDE, AS SHOWN AS ABOVE, OR PRISM SIDE OF THE LENS.