搜档网
当前位置:搜档网 › 家庭火灾报警系统的设计

家庭火灾报警系统的设计

家庭火灾报警系统的设计
家庭火灾报警系统的设计

成都理工大学工程技术学院毕业论文

家庭火灾报警系统的设计作者姓名:2B

专业名称:测控技术与仪器

指导教师:2B

摘要

目前,随着电子产品在人类生活中的使用越来越广泛,由此引起的火灾也越来越多,在我们生活得四周到处潜伏着火灾隐患。为了避免火灾以及减少火灾造成的损失,我们必须按照“隐患险于明火,防患胜于救灾,责任重于泰山”的概念设计和完善火灾自动报警系统,将火灾消灭在萌芽状态,最大限度地减少社会财富的损失。

本文采用气体传感器、温度传感器、AT89S52单片机以及LED显示灯模块设计了一种智能火灾报警器,可以实现声光报警、故障自诊断、浓度显示、报警限设置、延时报警及等功能。文中详细介绍了主控核心芯片、外围芯片的工作原理,各模块电路的硬件设计;叙述了软件工作流程和各子程序的工作流程。

关键词:单片机火灾报警传感器硬件设计软件设计

- I -

Abstract

Now, along with the electronic products in the use of human life is more and more extensive, the cause of the fire more and more, in our life everywhere around potential fire hazard. In order to avoid fire and reduce the loss caused by fire, we must, in accordance with the "hidden trouble risks in bright fire, the committee is better than relief, responsibility than mount tai" concept design and perfect automatic fire alarm system, will fire nipped in the bud, minimize the loss of wealth of society.

In this article, the gas sensor, the temperature sensor, and AT89S52 SCM LED display light module design a kind of intelligent fire alarm, can achieve sound and light alarm, fault diagnosis, concentration, the alarm limit that setting, delay alarm and etc. Function. This paper introduces the main control core chip, peripheral chip principle of work, each module circuit hardware design; Describes the software work flow and the procedure flow of work.

Key words: A single-chip microcomputer fire alarm sensor hardware design software design

- II -

目录

摘要...................................................................................................................................... I ABSTRACT ........................................................................................................................... I I 目录................................................................................................................................... III 第1章前言 . (1)

1.1选题背景及意义 (1)

1.2火灾报警系统的类型 (1)

1.3火灾探测的原理 (2)

1.4论文的主要内容 (3)

第2章火灾报警系统的工作原理 (5)

2.1系统的总体结构框图 (5)

2.2系统控制核心AT89S52 (5)

2.2.1 主要特性 (6)

2.2.2 引脚及功能 (7)

2.3外围芯片选择 (9)

2.3.1 集成温度传感器AD590 (9)

2.3.2 气体传感器TGS-202 (10)

2.3.3 数码管驱动芯片ICM7218 (10)

第3章系统硬件电路设计 (12)

3.1单片机晶振和复位电路 (12)

3.3信号处理电路 (13)

3.4A/D转换模块 (13)

3.5声音报警电路 (15)

3.6数码管显示电路 (15)

3.7状态指示灯及控制键电路 (16)

- III -

3.8报警器故障自诊断 (18)

第4章系统软件设计 (19)

4.1主程序流程图 (19)

4.2主程序初始化流程图 (21)

4.3滤波子程序 (21)

4.4线性化子程序 (22)

4.5报警子程序 (24)

4.6键盘处理子程序 (26)

结论 (27)

致谢 (28)

参考文献 (29)

附件1 主程序清单 (30)

附件2 整体硬件原理图 (31)

- IV -

第1章前言

1.1 选题背景及意义

火灾是可燃物在时间或空间上失去控制的燃烧所造成的灾害,是威胁公众安全和社会发展的主要灾害之一。火,在给人类带来文明进步、光明和温暖的同时也在其失去控制之时给人类造成了巨大的灾难。据统计,我国70年代火灾平均损失不到2.5亿元,80年代火灾平均损失接近3.2亿元。进入90年代,特别是1993年以来,火灾造成的直接损失上升到年均十几亿元,年均死亡2000多人。

严峻的事实证明,随着社会和经济的发展,社会财富日益增加,火灾给人类和社会和自然造成的危害范围不断扩大,它不仅毁坏物质财产,造成社会秩序的混乱,还直接威胁生命安全,给人们的心灵造成极大的伤害。残酷的现实让人们逐渐认识到监控预警和消防工作的重要性,良好的监控系统和及时的报警机制可以大大降低人员的上网,为社会减少不必要的损失。

随着电子产品在人类生活中的使用越来越广泛,由此引起的火灾也越来越多,在我们生活的四周到处潜伏着火灾隐患。智能化火灾报警系统已并非传统意义上的简单的报警设备,而是融入了计算机技术、电子技术、自动控制技术、传感器的应用等各领域知识。伴随着科学技术的不断进步,火灾报警系统必将得到更快的发展

1.2 火灾报警系统的类型

根据火灾报警系统中所使用的探测器种类的不同,火灾报警系统可以分为以下四种:

(1)感温型火灾报警系统

由于火灾发生时燃烧物会产生大量的热量,使得周围温度迅速变化。感温型火灾报警系统就是通过判断周围温度变化而产生响应的火灾报警系统,再把温度的变化转换为电信号以达到判断报警的目的。

- 1 -

根据探测温度参数的不同,一般可以将感温型火灾报警系统分为定温式、温差式等几种。

(2)感烟型火灾报警系统

烟雾是早期火灾的重要特征之一。在火灾发生的初期,由于温度比较低,许多物质都处于阴燃阶段,产生大量的烟雾。感烟型火灾报警系统就是对空气中可见或不可见的烟雾粒子进行探测,然后将烟雾浓度的变化转换为电信号来触发报警。感烟型火灾报警系统主要有激光感烟式、光电感烟式和离子感烟式等。

(3)感光型火灾报警系统

物质燃烧不但会产生烟雾和热量,同时也会产生可见或不可见的光辐射。感光型火灾报警系统就是通过响应火灾中产生的光特性,即扩散火焰的光强度和闪烁频率,来触发报警系统的。根据感应的敏感波长,可以将感光型火灾报警系统分为对波长较短的光辐射敏感的紫外报警系统和对波长较长的光辐射敏感的红外报警系统。

(4)复合型火灾报警系统

如果报警系统同时对温度、烟雾和光辐射中的两种或两种以上参数做出响应,那么它就是复合型火灾报警系统。目前复合型火灾报警系统有感温感烟型、感烟感光型、感温感光型等多种形式。

1.3 火灾探测的原理

火灾发生时,必然会伴随着产生烟雾、高温和火光,探测器对这些都很敏感。当有烟雾、高温、火光产生的时候,它就改变平时的正常状态,引起电流、电压或机械部分发生变化或位移,再通过放大、传输等过程发出警报声,有的还能同时发出灯光信号并显示发生火灾的部位、地点。

火灾探测器主要分感烟、感温、光辐射三大类:

(1)感烟探测器。一种是离子感烟探测器,它在内外电离室里面有放射源镅241,电离产生的正负离子,在电场的作用下各向正负电极移动。在正常的情况下,内外电离室的电流、电压都是稳定的。一旦有烟雾窜逃外电离室,干扰了带电粒子的正常运动,电流、电压就有所改变,破坏了内外电离室之间的平衡,于是就发出了信号。还有

- 2 -

一种叫光电感应探测器,它有一个发光元件和一个光敏元件,平常光源发出的光,通过透镜射到光敏元件上,电路维持正常,如果有烟雾从中阻隔,到达光敏元件上的光就显著减弱,于是光敏元件就把光强的变化变成电的变化,通过放大电路向人们报警。还有一种叫管道抽吸式感烟探测器,他的工作原理与光电感应探测器中另一种散射型相似,通过烟雾的反射或散射产生光敏电流,主要用在船舶上。近年来还出现了激光感烟探测器,它也是利用光电感应原理,不同的是光源改用激光束。这种探测器采用半导体器件,体积小、价格低、耐震动、寿命长,很有发展前途。

(2)感温探测器。一种是运用金属热胀冷缩的特性。正常的情况下,探测器的电路断开,当温度升到一定值时,由于金属膨胀、延伸,导体接通,于是发出了信号。一种是利用某些金属易熔的特性,在探测器里固定一块低熔点合金,当温度升到它的熔点(70~90℃)时,金属熔化,借助弹簧的作用力,使触头相碰,电路接通,发出信号。这两种探测器都属定温型,即当外界温度超过某一限值时就会报警;还有一类是差温型,升温的速度超过特定值时,便会感应报警。

(3)光辐射探测器。一种是红外光辐射探测器。物质在燃烧时,由化学反应产生闪烁的红外光辐射使硫化铅红外光敏元件感应,转变成电信号,经放大后,就能向人们报警。另一种是紫外光辐射探测器,则利用有机化合物燃烧时,火光中的紫外光,使紫外光敏管的电极激发出离子,通过继电器等,就能打开开关电路报警。

火灾报警器是重要的安全设备,一切重要的场所,如大型物资仓库、隧道、大型船舶、高层建筑都应该安装。它还可以与自动灭火设备一起组成自动报警、自动灭火的“自动消防队”。

1.4 论文的主要内容

本系统采用ATMEL公司的AT89S52单片机作为处理器,主要完成以下工作:

1. 基于AT89S52的火灾报警检测设计方案。

2. 温度传感器AD590、烟雾传感器TGS202、A/D转换芯片ADC0809的选择以及与单片机的接口电路设计。

- 3 -

3. LED数码管驱动芯片ICM7218与单片机的接口电路及其与数码管的硬件连接。

4. 设计主要软件程序模块,完成软件设计。

- 4 -

- 5 -

第2章 火灾报警系统的工作原理

2.1 系统的总体结构框图

本文采用气体传感器、温度传感器、AT89S52单片机以及LED 显示灯模块设计了一种智能火灾报警器,可以实现声光报警、故障自诊断、浓度显示、报警限设置、延时报警及与上位机串口通信等功能。是一种结构简单、性能稳定、使用方便、价格低廉、智能化的火灾报警器,具有一定的实用价值。整体设计的框图如图2.1所示:

图2.1 系统原理及组成框图

2.2 系统控制核心AT89S52

在火灾报警器的设计中,单片机是其核心部件。它一方面要接收来自传感器送来的温度、烟雾对应的模拟信号和故障检测信号,另一方面要对这两种信号分别进行处理,以控制后续电路进行相应动作;与此同时查询是否有键按下的请求。在单片机完成这些工作的过程传感放

路 A/D 转换

单片机

状态指示灯 声音报警 浓度显示 按键

串口通信

中,尤其是信号处理中,比较浓度值后送入显示的软件实现比较复杂,要求单片机具备较快的运算速度,使检测人员能够较准确地观测到烟雾浓度,并根据情况进行相应的处理。并且也要考虑选择低价实用的机型,并为研制同一系列的低功耗产品做准备。根据多方面的比较,本设计选用ATMEL公司的AT89S52单片机作为控制器。

图2.2 DIP-40封装AT89S52引脚图

2.2.1 主要特性

AT89S52是一个低功耗、高性能的CMOS 8位单片机,片内含4k Bytes(In-system programmable)的可反复擦写1000次的Flash 只读程序存储器,器件采用ATMEL公司的高密度、非易失性存储技术制造兼容标准MCS-51指令系统及80C51引脚结构。芯片内集成了通用8位中央处理器和ISP Flash存储单元,AT89S52片内集成256字节程序运行空间、8K字节Flash存储空间,支持最大64K外部存储扩展。根据不同的运行速度和功耗的要求,时钟频率可以设置在0-33M 之间。片内资源有4组I/O控制端口、3个定时器、8个中断、软件设

- 6 -

置低能耗模式、看门狗和断电保护。可以在4V到5.5V宽电压范围内正常工作。根据本次设计的具体情况,采用双列直插DIP-40封装。AT89S52的引脚图如图3.1所示:

2.2.2 引脚及功能

VCC:电源电压输入端

GND:电源地

P0口:P0口为一个8位漏级开路双向I/O口,每脚可吸收8TTL门电流。当P1口的管脚第一次写1时,被定义为高阻输入。P0能够用于外部程序数据存储器,它可以被定义为数据/地址的低八位。在FIASH编程时,P0 口作为原码输入口,当FIASH进行校验时,P0输出原码,此时P0外部必须被拉高。

P1口:P1口是一个内部提供上拉电阻的8位双向I/O口,P1口缓冲器能接收输出4TTL门电流。P1口管脚写入1后,被内部上拉为高,可用作输入,P1口被外部下拉为低电平时,将输出电流,这是由于内部上拉的缘故。在FLASH编程和校验时,P1口作为第八位地址接收

P2口:P2口为一个内部上拉电阻的8位双向I/O口,P2口缓冲器可接收,输出4个TTL门电流,当P2口被写“1”时,其管脚被内部上拉电阻拉高,且作为输入。并因此作为输入时,P2口的管脚被外部拉低,将输出电流。这是由于内部上拉的缘故。P2口当用于外部程序存储器或16位地址外部数据存储器进行存取时,P2口输出地址的高八位。在给出地址“1”时,它利用内部上拉优势,当对外部八位地址数据存储器进行读写时,P2口输出其特殊功能寄存器的内容。P2口在FLASH编程和校验时接收高八位地址信号和控制信号。

P3口:P3口管脚是8个带内部上拉电阻的双向I/O口,可接收输出4个TTL门电流。当P3口写入“1”后,它们被内部上拉为高电平,并用作输入。作为输入,由于外部下拉为低电平,P3口将输出电流(ILL)这是由于上拉的缘故。P3口除了作为普通I/O口,还有第二功能:

- 7 -

P3.0 RXD 串行输入口

P3.1 TXD 串行输出口)

P3.2 /INT0 外部中断0

P3.3 /INT1 外部中断1

P3.4 T0 T0定时器的外部计数输入

P3.5 T1 T1定时器的外部计数输入

P3.6 /WR 外部数据存储器的写选通

P3.7 /RD 外部数据存储器的读选通

I/O口作为输入口时有两种工作方式,即所谓的读端口与读引脚。读端口时实际上并不从外部读入数据,而是把端口锁存器的内容读入到内部总线,经过某种运算或变换后再写回到端口锁存器。只有读端口时才真正地把外部的数据读入到内部总线。89C51的P0、P1、P2、P3口作为输入时都是准双向口。除了P1口外P0、P2、P3口都还有其他的功能。

RST:复位输入端,高电平有效。当振荡器复位器件时,要保持RST脚两个机器周期的高电平时间。

ALE/PROG:地址锁存允许/编程脉冲信号端。当访问外部存储器时,地址锁存允许的输出电平用于锁存地址的低位字节。在FLASH编程期间,此引脚用于输入编程脉冲。在平时,ALE端以不变的频率周期输出正脉冲信号,此频率为振荡器频率的1/6。因此它可用作对外部输出的脉冲或用于定时目的。然而要注意的是:每当用作外部数据存储器时,将跳过一个ALE脉冲。如想禁止ALE 的输出可在SFR8EH地址上置0。此时, ALE只有在执行MOVX,MOVC指令是ALE才起作用。另外,该引脚被略微拉高。如果微处理器在外部执行状态ALE禁止,置位无效。

PSEN:外部程序存储器的选通信号,低电平有效。在由外部程序存储器取指期间,每个机器周期两次/PSEN有效。但在访问外部数据存储器时,这两次有效的/PSEN信号将不出现。

EA/VPP:外部程序存储器访问允许。当/EA保持低电平时,则在此期间外部程序存储器(0000H-FFFFH),不管是否有内部程序存储器。注意加密方式1时,/EA将内部锁定为RESET;当/EA端保持高电平时,此间内部程序存储器。在FLASH编程期间,此引

- 8 -

- 9 -

脚也用于施加12V 编程电源(VPP )。

XTAL1:片内振荡器反相放大器和时钟发生器的输入端。

XTAL2:片内振荡器反相放大器的输出端。

2.3 外围芯片选择

2.3.1

集成温度传感器

AD590

图3.2 AD590应用电路

AD590是美国Analog Devices 公司生产的一种电流型二端传感器,电路如图所示。由于AD590是电流型温度传感器,它的输出同绝对温度成正比,及1 A ∕K ,,而数模转换芯片ADC0809的输入要求是电压量,所以在AD590的负极接出一个10千欧的电阻R1和一个100欧的可调电阻W ,将电流量变为电压量送入ADC080。通过调节可调电阻便可在输出端V T 获得与绝对温度成正比的电压量,即10mV ∕K,温度0℃时输出为0,温度25℃时输出为2.982V 。这样便于A/D 转换器采集数据。AD590的应用电路如图3.2所示

- 10 -

2.3.2

气体传感器TGS-202

图3.3 TGS202检测电路

火灾中气体烟雾主要是CO ?和CO ,TGS202气体传感器能探测CO ?,CO ,甲烷,煤气等多种气体,它灵敏度高,稳定性好,适合于火灾中气体的探测。如上图所示,当TGS202探测到CO ?或CO 时,传感器的内阻变小,V A 迅速上升。选择适当的电阻阻值,使得当气体浓度达到一定程度(如CO 浓度达到0.06﹪)时,V A 端获得适当的电压(设为3V )。电路图如图3.3所示。

2.3.3 数码管驱动芯片ICM7218

ICM7218 是INTERSIL 公司生产的一种性能价格比较高的通用8 位L ED 数码管驱动电路, 28 脚双列封装,是一种多功能L ED 数码管驱动芯片,可与多种单片机接口使用。ICM7218 的输出可直接驱动L ED 显示器,不需外接驱动电路,工作电压为+5V,其构成的显示电路结构简单,使用方便。同样由单片机向ICM7218写控制字及数据,编程部分像给外部RAM 写数据一样简单。

当单片机写入模式控制字后,ICM7218以约定的方式接收显示数据并将数据写入静态显示RAM 中。数据接收结束,ICM7218在扫描控制电路的控制下,按设定的译码模式,以动态扫描显示方式向段显示驱动器和位控驱动器发出控制信号,直到下一个控制字写入前,不停地进行动态显示工作。其引脚图和内部框图如图3.4所示。

图3.4 ICM7218引脚图及内部框图

- 11 -

第3章系统硬件电路设计

3.1 单片机晶振和复位电路

AT89S52单片机外围接口电路如图3.1所示,主要包括:

1.晶振电路:内部时钟电路的晶振频率一般选择在4MHZ~12MHZ之间(该设计选用6MHZ),外接两个谐振电容。该电容的典型值为30pF,该设计选用33pF。

2.复位电路:单片机复位采用按键高电平复位,而单片机在平时则复位端为低电平0。

3.直流电源

图3.1 单片机外围接口电

- 12 -

3.3 信号处理电路

图3.6 信号处理电路

对于传感器输出的模拟信号,一般要用运算放大器对其进行调理或放大,以满足A/D转换器对输入模拟量幅值及极性的要求。在本报警器电路中,同样要对两类传感器的输出信号进行放大调理。电路图如上图 3.6所示,运算放大器接成电压放大电路。从传感器采集过来的微弱电压信号,经过电压放大器的放大,得到较强的模拟电压信号。采样时,把相应的模拟电压信号从Vi端送进LM324A进行放大处理后,从Vo端输出送入A/D转换电路。

3.4 A/D转换模块

经传感器所检测的电压信号为模拟信号,无法直接被单片机所识别,所以在经过放大电路后对信号进行A/D装换,将模拟信号转化为数字信号输入单片机。

- 13 -

A/D转换电路采用了常用的8位8通道数模转换常用芯片ADC0809,烟雾、温度传感器的输出端分别接到ADC0809的IN0和IN1。 ADC0809的通道选择地址由AT89S52的P0.0~P0.2经地址锁存器74LS373输出提供。当P2.7=0时,与写信号WR共同选通ADC0809。其中ALE信号与ST信号连在一起,在WR信号的前沿写入地址信号,在其后沿启动转换。图中ADC0809转换结束状态信号EOC接到AT89S52的INT1引脚,当A/D转换完成后,EOC变为高电平,表示转换结束,产生中断。在中断服务程序中,将转换好的数据送到指定的存储单元。由于ADC0809片内无时钟,故利用8051提供的地址锁存使能信号ALE经D触发器二分频后获得时钟。因为ALE信号的频率是单片机时钟频率的1/6,如果时钟频率为6MHZ,则ALE信号的频率为1MHZ,经二分频后为500KHZ,与ADC0809的典型值吻合。电路图如3.7所示。

图3.7 A/D转换电路

- 14 -

3.5 声音报警电路

由AT89S52的21脚实现声音报警控制。当可燃性气体浓度或温度超过限定值时,将P2.0置为低电平,三极管导通,扬声器发出鸣叫

所示。

报警。其电路原理图如图3.8

图3.8 声音报警电路图

3.6 数码管显示电路

数据采集进来并被成功地由模拟量转化为数字量后,就被传送到系统的显示模块,让人们更直接地观察到相关数据。在本系统中,对LED进行的是动态扫描,除了给显示器提供段的输入之外,还要对显示器进行位控制。显示器的第一位显示所选择的通道号,而后三位则显示该通道传送进来的相应的数字量。

本系统显示用的4位七段数码管由数码管专用驱动芯片ICM7218A驱动,27、3、1、25、2、24、26脚分别接数码管的a、b、c、d、e、f、g,15、16、23、20脚为位选,分别控制4位数码管的亮灭,ID0~7为数据线,接单片机P0口,WRITE、MODE是写

- 15 -

家庭防盗报警系统设计

家庭防盗报警系统设计 1 绪论 1.1家庭报警器发展现状及其系统构成与分类 1.1家庭防盗报警器的发展 从上世纪初,报警系统就已经在北美稍具雏形。在北美,报警呼救箱放置在街头巷尾,在呼救时发出声响提示,以寻求附近警察的帮助;同时,这种呼救箱直接连接到附近的警局,使得稍远一些的警察也能够收到呼救信息。随后,由于通信技术的发展,提供远程通信服务的电报公司加入到这个行业中,从而使得报警信息可以通达到更远的地方;不过,这种电报方式毕竟难以普及,所以稍后出现的电话理所当然地成为报警通讯的主要手段。而此后自动拨号系统的出现以及电话普及到千家万户,更使得通过电话线报警的方式得到了前所未有的发展。 从以上过程来看,报警行业的发展是以工业技术发展为基础的,只有具备良好的通信手段,才能够把各地的报警信息汇聚到相应的权威部门,然后由权威部门负责分配有限的警力来帮助到所有的社会个体。 国外智能监控防盗技术发展已处于一个较高水平阶段,从具有代表性的北美发展过程,可以清楚的看出世界智能监控防盗技术的发展概况。其具有以下特点,值得我们借鉴。 目前,对北美的安防产业来说,最成功的经营模式就是联网报警服务模式,联网报警将整个北美的安防产业从横向到纵向进行整合串并,形成了一个集中许多高科技手段和产业化管理水准的一体化综合性产业。比如世界排名第一,北美最大的安防跨国公司一美国棋诺亚公司,它在世纪年代开始搞简单的防盗报警,其当时的业务范围和技术水平跟中国现在很多安防企业是相当的。到70年代,它对其产业的整体发展方向做了很大的调整,变为联网报警服务商,建立了首家网管中心,尤其是在年代引用了大量的网管技术、系统集成技术和电子技术,现己成为十分先进的联网报警服务平台,它在美国、加拿大、英国、香港、台湾等多个国家和地区都有分公司,北美的客户数己超过600万,2003年防盗报警收入总产值达105亿美元。 第 1 页(共 32 页)

火灾自动报警及消防联动控制系统设计说明

火灾自动报警及消防联动控制系统设计说明 1、系统构成: (1)火灾自动报警系统 (2)消防联动控制 (3)火灾应急广播系统 (4)消防直通对讲电话系统 (5)漏电火灾报警系统 (6)大空间智能型灭火装置集中控制系统(消防水炮控制系统) (7)智能消防应急疏散照明指示灯系统 2.系统概况: (1)本工程为一类防火建筑.火灾自动报警的保护等级按特级设置.设控制中心报警系统和消防联动控制系统。 (2).系统组成:火灾自动报警系统;消防联动控制系统;火灾应急广播系统;消防直通电话对讲系统;漏电火灾报警系统;大空间智能型灭火装置集中控制系统(消防水炮控制系统);智能消防应急疏散照明指示灯系统。 3.消防控制室: (1)本工程的消防控制室设置在一层西侧,负责本工程全部火灾报警及联动控制系统,设有直接通室外的出口. (2)消防控制室可联动所有与消防有关的设备。 (3)消防控制室的报警联动设备由火灾报警控制主机、联动控制台、CRT显示器、打印机、广播设备、消防直通对讲电话设备、电源设备等组成。 (4)消防控制室可接收感烟、感温、可燃气体等探测器的火灾报警信号及水流指示器、检修阀、压力报警阀、手动报警按钮、消火栓按钮以及消防水炮的动作信号。 (5)消防控制室可显示消防水池、消防水箱水位,显示消防水泵等的电源及运行情况。 4.火灾自动报警系统: (1)本工程采用消防控制室报警控制系统,火灾自动报警系统按四总线设计。 (2)探测器:柴油发电机房、厨房、车库等处设置感温探测器,直燃机房设防爆型可燃气体探测器,其他场所设置感烟探测器。 (3)探测器安装:探测器与灯具的水平净距应大于0.2m;至墙边、梁边或其他遮挡物

火灾报警系统的设计毕业设计

本 科毕业设计 (自然科学) 题 目:火灾报警系统的设计(偏硬) Hebei Normal University of Science & Technology 专业:电气工程及其自动化 学号:93110070121

毕业设计(论文)原创性声明和使用授权说明 原创性声明 本人郑重承诺:所呈交的毕业设计(论文),是我个人在指导教师的指导下进行的研究工作及取得的成果。尽我所知,除文中特别加以标注和致谢的地方外,不包含其他人或组织已经发表或公布过的研究成果,也不包含我为获得及其它教育机构的学位或学历而使用过的材料。对本研究提供过帮助和做出过贡献的个人或集体,均已在文中作了明确的说明并表示了谢意。 作者签名:日期: 指导教师签名:日期: 使用授权说明 本人完全了解大学关于收集、保存、使用毕业设计(论文)的规定,即:按照学校要求提交毕业设计(论文)的印刷本和电子版本;学校有权保存毕业设计(论文)的印刷本和电子版,并提供目录检索与阅览服务;学校可以采用影印、缩印、数字化或其它复制手段保存论文;在不以赢利为目的前提下,学校可以公布论文的部分或全部内容。 作者签名:日期:

独创声明 本人郑重声明:所呈交的毕业设计(论文),是本人在指导老师的指导下,独立进行研究工作所取得的成果,成果不存在知识产权争议。尽我所知,除文中已经注明引用的内容外,本设计(论文)不含任何其他个人或集体已经发表或撰写过的作品成果。对本文的研究做出重要贡献的个人和集体均已在文中以明确方式标明。 本声明的法律后果由本人承担。 作者签名: 二〇一〇年九月二十日 毕业设计(论文)使用授权声明 本人完全了解滨州学院关于收集、保存、使用毕业设计(论文)的规定。 本人愿意按照学校要求提交学位论文的印刷本和电子版,同意学校保存学位论文的印刷本和电子版,或采用影印、数字化或其它复制手段保存设计(论文);同意学校在不以营利为目的的前提下,建立目录检索与阅览服务系统,公布设计(论文)的部分或全部内容,允许他人依法合理使用。 (保密论文在解密后遵守此规定) 作者签名: 二〇一〇年九月二十日

火灾自动报警系统方案设计

火灾自动报警系统方案 ●本系统采用控制中心型智能消防报警系统,具有火灾报警、联动控制等功能。系统包括以下内 容:手动报警按钮、感烟探测器、感温探测器、警铃和水流指示器等报警装置,系统同时监视 消火栓按钮、报警阀、压力开关、水流指示器及信号阀等的动作信号。 ●为了便于控制和管理,所有消防信号将显示于总控制屏上,以便一旦发生火灾时,可迅速报告 消防局。 ●消防总控制室内有以下设备:消防系统主机(工作站)、火灾视屏显示屏(LED)、火灾自动报警 系统总控制屏、消防联动控制盘、消防专用电话主机、应急电源配电盘和UPS电源、消防系统 运行记录打印机等。消防控制室可监听所有消防电源设备的状态。另外,消防总控制室内设置 一部直拨消防单位的外线电话,并同时提供与消防电话插孔匹配的手提电话。 (1)火灾报警系统保护目标 ●快速火灾探测 ●准确定位火灾地点 ●及时发出火灾报警信号 ●警示相关人员以实现: ●快速疏散建筑物内人群 ●通知相关部门采取救援措施 ●指示相关消防设备动作以实现: ●自动启动消防泵、喷淋泵等水系统灭火设备 ●联动火灾隔断手段如关闭防火卷帘门和防火阀等 ●开启排烟风机、正压风机等防排烟设备 ●开启应急广播、应急照明和疏散指示系统 (2)系统设计原则 ●系统应符合中国有关法律法规,符合消防管理条例和标准。 ●遵照安全第一、预防为主的原则,火灾自动报警系统应严格保证设备可靠性和系统可靠性,避 免误报。 ●系统应具有先进性和适用性:系统的技术性能和质量指标均达到国际先进水平,且在安装调试、 软件编程和操作使用各方面均简便易行,并适合建筑特点,达到最佳的性能价格比。 ●在系统设计时应明确与建筑设备监控系统、安防系统之间的接口界面,且系统的各项技术规范 均符合相应要求。 ●在设计火灾自动报警系统时应预留该系统与综合信息共享管理系统之间信息数据交换接口,系 统的各项技术规范均符合相应要求。 ●在系统设计时应尽量优化设备配置,考虑了整个建筑全系统的统筹配置,避免设备的重复购置 和管线的混乱局面。 在系统设计时应保留足够的冗余度:探测点与控制点的容量上及回路卡的设置上均应保留不少于20%的扩展余地。报警系统施工主要程序:

(完整word版)智能家居防盗报警系统的设计.

摘要 随着科技的飞速发展,人们的工作、生活中涌现出各种各样的科技产品,其中的电子产品更是花样繁多、遍及工作、生活的方方面面。智能家居防盗报警系统是近年来发展极为迅速、应用面极广的防盗报警控制系统,它具有控制能力强、操作方便灵活、可靠性高、适应能力强的特点。 本文介绍了一款易于扩展的基于单片机的家居智能防盗报警系统, 用较低的成本实现家居的高安全性。主要由AT89C52单片机、热释电传感器、信号处理电 路、蜂鸣器语音报警电路、LED显示电路等部分组成。系统主要功能是防盗报警,它由热释电传感器作为探测器,将信号输入单片机中,判断是否有危情,若有则利用蜂鸣器报警。中断申请后再查询的方式使系统的误报率有效降低,并使系统的可靠性大为增强,因而在智能家居防盗报警系统中极具发展前景。本文给出了该家居防盗报警系统的硬件组成,阐述了系统工作方式,并给出主程序和子程序的流程图。 关键词:单片机;防盗报警;传感器 I Abstract With the rapid development of science and technology, all kinds of products emerge in people's work and life including various electronic products. The system of intellectual home anti-theft alarm is an anti-theft alarm control system which has developed very quickly in recent years and is applied widely.This characters of the system is the enough ability to control, convenient and flexible to operate, high reliability and adaptability. This paper introduces a set of intellectual home anti-theft alarm system based on microcontroller with lower cost to achieve the high-security home environment. It mainly consists of four parts which are the AT89C52, the pyroelectric sensor, signal processing circuit, alarming circuit by buzzer,displaying circuit by LED and so on. The main function of this system is to alarm when the home is in danger. It uses the pyroelectric sensor as a detector,transports the signal into the microcontroller to tell whether the home is dangerous.If the home is in danger ,the system would alarm by buzzer. Due to the design of the inquiries of interruption before the usage of query, the false alarm rate is reduced effectively and the reliability of the system is greatly increased,which is applied widely in the anti-theft alarm system of intellectual home. The paper gives the hardware components of the system, illustrates the work way of the system, and gives the flow chart of main program and subroutine. Key words: Microcontroller; Anti-theft Alarm; Sensor II

火灾报警系统的设计毕业设计

毕业论文声明 本人郑重声明: 1.此毕业论文是本人在指导教师指导下独立进行研究取得的成果。除了特别加以标注地方外,本文不包含他人或其它机构已经发表或撰写过的研究成果。对本文研究做出重要贡献的个人与集体均已在文中作了明确标明。本人完全意识到本声明的法律结果由本人承担。 2.本人完全了解学校、学院有关保留、使用学位论文的规定,同意学校与学院保留并向国家有关部门或机构送交此论文的复印件和电子版,允许此文被查阅和借阅。本人授权大学学院可以将此文的全部或部分内容编入有关数据库进行检索,可以采用影印、缩印或扫描等复制手段保存和汇编本文。 3.若在大学学院毕业论文审查小组复审中,发现本文有抄袭,一切后果均由本人承担,与毕业论文指导老师无关。 4.本人所呈交的毕业论文,是在指导老师的指导下独立进行研究所取得的成果。论文中凡引用他人已经发布或未发表的成果、数据、观点等,均已明确注明出处。论文中已经注明引用的内容外,不包含任何其他个人或集体已经发表或撰写过的研究成果。对本文的研究成果做出重要贡献的个人和集体,均已在论文中已明确的方式标明。 学位论文作者(签名): 年月

关于毕业论文使用授权的声明 本人在指导老师的指导下所完成的论文及相关的资料(包括图纸、实 验记录、原始数据、实物照片、图片、录音带、设计手稿等),知识产权归 属华北电力大学。本人完全了解大学有关保存,使用毕业论文的规定。同 意学校保存或向国家有关部门或机构送交论文的纸质版或电子版,允许论 文被查阅或借阅。本人授权大学可以将本毕业论文的全部或部分内容编入 有关数据库进行检索,可以采用任何复制手段保存或编汇本毕业论文。如 果发表相关成果,一定征得指导教师同意,且第一署名单位为大学。本人 毕业后使用毕业论文或与该论文直接相关的学术论文或成果时,第一署名 单位仍然为大学。本人完全了解大学关于收集、保存、使用学位论文的规 定,同意如下各项内容: 按照学校要求提交学位论文的印刷本和电子版本;学校有权保存学位 论文的印刷本和电子版,并采用影印、缩印、扫描、数字化或其它手段保 存或汇编本学位论文;学校有权提供目录检索以及提供本学位论文全文或 者部分的阅览服务;学校有权按有关规定向国家有关部门或者机构送交论 文的复印件和电子版,允许论文被查阅和借阅。本人授权大学可以将本学 位论文的全部或部分内容编入学校有关数据库和收录到《中国学位论文全 文数据库》进行信息服务。在不以赢利为目的的前提下,学校可以适当复 制论文的部分或全部内容用于学术活动。 论文作者签名:日期: 指导教师签名:日期: 专业:电气工程及其自动化 学号:93110070121

消防报警系统设计方案

博物馆消防火灾报警系统工程 施工组织设计方案 1.编制说明、 本设计依据建筑设计研究院有限公司电施设计图纸进行编制。 2.工期 工期目标: 消防火灾报警系统工程工期为40天。 七氟丙烷气体灭火系统工程施工工期为30天。 3.质量目标 本工程质量目标: 消防工程施工质量将严格按有关设计及施工验收规和工程评定标准进行施工,合格率达到时100%,确保火灾自动报警系统质量优良。 4.火灾报警系统设备安装工艺要求 4.1火灾自动报警系统设备安装 (1)消防布线的总体要求: 根据消防弱电施工的规,并结合本工程的实际情况,对消防电气的施工布置如下:布线:火灾自动报警系统的布线,应符合现行标准《电气装置工程施工及验收规》的规定和《火灾自动报警系统设计规》(GBJ116-88)的要求。管线包括各层公共部分及其它层平面报警回路线、工作电源线、控制线等线管的穿线,应采用铜芯绝缘导线或铜芯电缆,当额定工作电压不超过50V时,选用导线的电压等级不应低于250V,额定工作电压超过50V时,导线电压等级

不应低于500V。穿线过程中应按照以下工艺标准及要点进行。 (2)接线箱安装: 穿线完毕后,要对每回路导线用500V的兆欧表测量绝缘电阻,满足不了产品或规GB50166--92要求的(20MΩ),应仔细检查并替换。 要求:平稳,底部距地1.5M。安装前应在距盒底100MM处开一个口,并且开口处无倒刺,然后牢固固定在墙上。 (3)火灾报警探测器的安装 A.火灾探测器安装位置,应符合下列规定: 探测器至墙壁梁边的水平距离,不应小于0.5m: 探测周围0.5m,不应有遮挡物: 探测器至空调送口边的水平距离,不应小于0.5m;至多孔送风顶棚孔口的水平距离,不应小于0.5m; 宽度小于3m的风走道顶棚上设置探测器时,宜居中布置。感温探测器的安装间距,不应超过10;感烟探测器的安装间距,不应超过15。探测器距端墙的距离,不应大于探测器安装间距的一半。 B.探测器底座安装 探测器的底座应固定向牢靠,其导线连接必须可靠压接或焊接。当采用焊接时,不得使用带腐蚀性的助焊剂。 探测器底座的外接导线,应留有不小于15cm的量,入端应有明显标志。 探测器底座的穿结孔宜封堵,安装完毕后的探测器底座应采取保护措施。 探测器在即将调试时方可安装,在安装前应妥善保管,并应采取防尘、防潮、防腐蚀措施。

基于单片机的智能家居防火防盗报警系统毕业设计

基于单片机的智能家居防火防盗 报警系统

随着社会的不断进步和科学技术、经济的发展,人们的生活水平得到很大的提高,人们愈加注重人身安全,因而也对防火防盗措施提出了新的要求。 本设计所做的智能家居控制系统包括室内信息智能监控功能、输入与实时显示功能、声光报警功能等。本文利用单片机结合传感器技术而开发设计了这一防火防盗报警系统。本设计采用DYP-ME003人体红外感应模块、18B20温度传感器和MQ_2烟雾传感器检测信号,然后将信号传送给单片机处理,实现声光报警。该系统通过按键对系统的温度和烟雾的浓度进行初始化设置,利用LED显示模块对系统的温度和烟雾的浓度进行实时显示。该系统结构简单、性能稳定、使用方便、价格低廉,具有一定的实用价值。 关键字:防火防盗报警 18B20 MQ_2 DYP-ME003 Abstract With society’s progress and development of science and technology, economy, people's living standard has been greatly improved. People pay more attention to personal safety, thus they put forward new requirements for the fire and security measures. In this design ,the intelligent family- house control system includes this function : indoor information intelligent monitoring , the input and real-time display ,sound and light alarm, and so on .The design is a fire and security system, which combines sensor technology with microcontroller. This design adopts the DYP-ME003 human body infrared sensor module,18b20 temperature sensor and MQ_2 smoke sensor to detection signal. These sensor send the signals to microcontroller process these signal and drive alarm circuit to achieve sound and light alarm .The fir temperature and smoke concentration are initialized in this system.,and are displayed in the LED display .The system has the advantages of simple structure ,stable performance ,conventional operation ,low price ,and has a certain practical value . Keywords : The fire and security system,18b20,MQ_2,DYP-ME003

火灾自动报警系统设计说明书

目录 1 引言.............................................. 错误!未定义书签。 2 工程概况.......................................... 错误!未定义书签。3火灾自动报警系统设计.............................. 错误!未定义书签。 火灾自动报警系统保护对象分级.................... 错误!未定义书签。 火灾自动报警系统形式的确定...................... 错误!未定义书签。 探测区域和报警区域划分.......................... 错误!未定义书签。 确定火灾探测器的种类、设置部位和数量............ 错误!未定义书签。 火灾探测器种类的选择......................... 错误!未定义书签。 火灾探测器的设置............................. 错误!未定义书签。 手动火灾报警按钮的设置.......................... 错误!未定义书签。 火灾报警控制器和监控系统的选择和系统布线以及工程应用错误!未定义书签。 消防联动控制设计................................ 错误!未定义书签。 火灾应急广播或火灾警报装置设置.................. 错误!未定义书签。4设计体会.......................................... 错误!未定义书签。参考资料............................................ 错误!未定义书签。

火灾报警系统设计方案

火灾报警系统设计方案 第一章绪论 1.1本课题研究背景 随着我们社会的不断发展,人们的生活、工作以及我们居住的环境愈来愈相对的集中,火灾发生的可能性也变得日益突出,火灾给人们所造成的损失和危害也越来越不可忽视,对广大人民群众的生命财产安全造成了很大的威胁。世界上很多国家都致力于各种各样的火灾报警系统的研究和实验,人们更加重视对火灾发生的及时发现与报警。2011年,我国公安部消防局公布了当年的全国火灾情况,全国共接到报火灾一共125402起,死亡人数一共1106人,受伤人数有572人,直接造成的财产经济损失有18.8亿元。其中,尤其是在节日期间,燃放烟花原因所造成的火灾有所增多,还有建设施工的工地、以及小作坊和小商店等场所火灾发生的数量较多,同时由于用电用火所引起的火灾,在火灾发生总量上仍然占据了比较大的比重。 统计数据显示,全国较大火灾共接报76起,死亡281人,受伤54人,直接财产损失8468.2万元,与2010年相比,死亡人数增加3.3%。全国公司厂房所发生的火灾6779起;居民住宅一共发生了火灾有48548起;而用作仓储场所引起的火灾一共5463起,人口比较集中的场所所发生火灾12471起,因为交通工具事故所造成的火灾13049起;易燃易爆地方事故所发生的火灾407起;城乡火灾总量下降。全国农村一共发生了火灾38469起,死亡349人,受伤154人,造成直接财产损失有39301.3万元。而城市已共引发火灾有43171起,死亡331人,受伤196人,造成的直接财产损失有55330万元;从以上统计数据可以看出,我国火灾情况不容乐观,因此,传统的火灾报警系统已经越来越不适应当今火灾发生的复杂情况了,而传统的火灾报警系统多采用RS-485总线作为通信方式,通信可靠性比较差。所以现在各国更加注重,更加智能、高效、可靠的型、火灾报警控制系统的开发。现代智能高效的火灾报警系统是一个将信号的检测、传输以及控制集于一体的控制系统, 指引了当今智能火灾报警系统的发展方向[1]。

火灾报警系统施工方案

施工组织设计 投标单位(盖章): 法定代表人(盖章): 编制时间:

目录 1、工程概况┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈2 2、系统介绍┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈2 3、编制依据┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈3 4、施工现场管理┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈3 5、施工人员要求┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈4 6、进度控制┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈4 7、施工工序┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈4 8、质量保证措施┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈18 9、危险源、危险点分析及预防┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈19 10、施工现场文明施工环保的要求┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈20 1、工程概况:

本工程名称: 地点: 2系统介绍: 本消防系统包含了火灾自动报警系统、漏电保护系统、消防广播系统、消防、组成; 2.1、火灾自动报警系统由电感烟探测器、手动报警按钮、各类模块、分机、插孔、扬声器、消火栓按钮、可燃气体探测器、模块箱等设备;本系统设消防控制室。室集中设置自动报警监控、消防及紧急广播设备,消防控制室设置一台火灾报警控制器,其消防及紧急广播系统接入消防控制室消防及紧急广播系统。消火栓启泵线引至一期消防水泵房启动水泵。火灾自动报警系统采用总线制控制中心报警系统,外部设备的全部报警信号送至报警控制器上,经分析判断及确认后,自动或手动发出经编码的联动信号,通过总线及模块启停相应的消防联动设备,同事接收状态反馈信号;系统供电采用220VAC消防电源,及在线式不间断电源供电,由业主提供; 2.2、消防广播系统在消防控制室设置消防广播机柜,在所有防火分区设置消防广播扬声器。在火灾时,可以手动或按程序自动启动消防广播系统; 2.3、消防在手动报警按钮上设有插孔,可直接与消防中心通话,配电室设有专用火警分机; 2.4、消火栓系统在各层消火栓箱设消火栓破碎玻璃按钮,当任一层发生火灾时有人破碎玻璃后,可直接启动消防按纽,并向消防控制中心发出信号;确认火灾后由主机启动消防水泵。 3、编制依据: 3.1、依据:《火灾自动报警系统设计规》GB50116-98 《自动喷水灭火系统施工及验收规》GB50261-2005 《气体灭火系统施工及验收规》GB50166-2007 3.2、依据有关的国家及部颁施工标准及验收技术规 4、施工现场管理组 临建:现场库房及现场加工车间的确定:根据现场的实际情况,经甲方指定我单位的临时

毕业设计(论文)-基于AT89C51单片机的家庭防盗报警系统设计

目录 1 绪论 (1) 1.1发展概况与设计背景 (1) 1.2本设计概述 (2) 2总体设计方案........................................................... . (3) 2.1方案选择论证....................................................... . (3) 2.2主控芯片单片机的选择....................................... . (3) 2.2.1 AT89C51的主要性能 (4) 2.2.2 AT89C51的引脚结构 (5) 2.3传感器的选择 (6) 2.3.1传感器的红外辐射与红外探测的原理结构 (7) 2.3.2红外测温原理 (7) 2.3.3热释红外传感器的结构 (8) 2.3.4 菲涅尔透镜 (10) 2.4热释电红外传感器控制电路芯片的选择 (11) 3 系统硬件设计 (13) 3.1低频带通放大电路 (13) 3.2电压比较整形电路 (14) 3.2.1双限电压比较器的工作原理 (14) 3.3报警电路 (15) 3.4灯光警示电路 (16) 3.5状态显示电路 (17) 3.6供电电源电路 (17) 3.7单片机最小系统 (18) 4 系统软件 (19) 4.1主程序流程图 (19) 4.2中断函数流程图 (20) 5结论 (21) 致谢 (22) 参考文献 (23) 附录一:系统电路图 (24) 附录二:系统程序 (25)

1 绪论 1.1发展概况与设计背景 随着社会的不断进步和科学技术、经济的不断发展,人们生活水平得到很大的提高,人们私有财产也不断地增多,因而也对防盗措施提出了新的要求。 从现代人们住宅发展的趋势来看,现代人们住宅主要是向群体花园式住宅区发展,向高空中发展,一般都是一个住宅区有几栋至几十栋以上,但目前市面上所拥有的家庭电子防盗报警器,只能用于单一的住宅单元,不利于统一管理,而且也不能满足现代住宅区的发展要求,所以很有必要对家庭电子防盗报警器进一步完善和提高。 本设计就是为了满足现代住宅防盗的需要而设计的家庭式电子防盗系统。它在以前的防盗器基础上进行了很大的改进,不但可以用于单一的住宅区,也可以规模用于比较大规模住宅区的防盗系统,它的工作性能好,不易出现不报和误报现象,安全可靠。不仅如此,它使用了单片机做信号处理器,这样有利于与计算机相连接,利用计算机统一管理,使整个小区的住户基本情况、资料等在计算机内存储起来,方便来访人的查询和保安人员的统一管理。 目前市面上装备主要有压力触发式防盗报警器、开关电子防盗报警器和压力遮光触发式防盗报警器等各种报警器,但这几种比较常见的报警器都存在一些缺点:(一)压力触发式防盗报警器由于压力板式安装在垫子内,当主机停止工作,主人在家走动时,都很容易失报和误报,其可靠性低。(二)开关式电子防盗报警器一般只有一个定点,有效范围小,而且各种开关也易坏,失报和误报率就高,不可靠。(三)遮光式触发防盗报警器在受到太阳光照射就会引起误报,同时如果由于风吹窗帘的摆动等遮住了光也会引起误报,所以这种报警器的可靠性也不高。再者,就闭路监控电路防盗系统而言:它的安装线路复杂,而且技术要求比较高,价格也比较昂贵,不利于广泛利用。 1.2本设计概述 综合以上报警器的不足,本系统采用了热释电红外传感器,它的制作简单、成本低,安装比较方便,而且防盗性能比较稳定,抗干扰能力强、灵敏度高、安全可靠。这种防盗器安装隐蔽,不易被盗贼发现。同时它的信号经过单片机系统处理后利于跟PC机通信,便于多用户统一管理。

火灾消防报警系统设计方案

城市职业学院 火灾消防报警系统设计方案 设计人员:黄建恒- 设计日期: 2015年 12 月29日

火灾消防报警系统说明 消防自控系统产业的形成是在八十年代中期,由于经济发展,新的建筑物日见增多,并且社会各方面对预防和消除火情十分重视,这样就产生了需求拉动。经过短时间的混乱后,由于国家主管部门的适时介入,有力地整合、规了市场,使本产业在有规可循、有法可依的基础上健康成长。 消防报警系统又称火灾报警系统,消防自动报警系统。由火灾报警主机、火灾特征或火灾早期特征传感器、人工火灾报警设备、输出控制设备组成。传感器完成对火灾特征或火灾早期特征的探测,并将相关信号传送到火灾报警主机。报警主机完成对信号的显示、记录,并完成相应的输出控制。火灾自动报警系统是人们为了早期发现通报火灾,并及时采取有效措施,控制和扑灭火灾,而设置在建筑物中或其它场所的一种自动消防设施,是人们同火灾作斗争的有力工具。

1.项目概况 本项目设计的是城市职业学院教学楼、食堂、学生宿舍(男、女寝)的消防报警系统。通过对学校消防报警系统的勘察,我们了解了学校消防系统的布局,例如,学校在教学楼各层都按放有消防报警设备(灭火器、消防提示(导向)、声光报警器、感烟、感温探测器、火灾指示灯等),但是根据学校的情况,我们的学校面积比较小,学生人数很多,有时候放学下楼时就特别的拥挤,有的楼层消防设备就不足。所以对于本系统的设计,例如我们在系统设计中增加了消防广播报警系统和导向指示牌。 2设计依据 区域报警系统的设计,应符合下列要求:一个报警区域宜设置一台区域火灾报警控制器或一台火灾报警控制器,系统中区域火灾报警控制器或火灾报警控制器不应超过两台;区域火灾报警控制器或火灾报警控制器应设置在有人值班的房间或场所;系统中可设置消防联动控制设备;当用一台区域火灾报警控制器或一台火灾报警控制器警戒多个楼层时,应在每个楼层的楼梯口或消防电梯前室等明显部位,设置识别着火楼层的灯光显示装置;区域火灾报警控制器或火灾报警控制器安装在墙上时,其底边距地面高度宜为1.3~1.5m,其靠近门轴的侧面距墙不应小于0.5m,正面操作距离不应小于1.2m。 系统设计的国家标准、行业规 ●《安全防视频监控联网系统信息传输、交换、控制技术要求》(GB/T 28181)●《安全防工程技术规》(GB 50348-2004) ●《安全防工程程序与要求》(GA/T75-94) ●《安全防系统验收规则》(GA308-2001) ●《安全防系统通用图形符号》(GA/T74-2000) ●《安全防系统》(DB33/T334-2001) ●《安全防工程技术规》(GB50348-2004) ●《安全防系统验收规则》(GA308-2001) ●《安全防工程程序与要求》(GA/T75-94) ●EIA/TIA568A,EIA/TIA569A 国际电子工业协会通信线缆、通讯路径和空间 标准

(完整word版)家庭报警防盗报警系统设计传感器课程设计..

传感器课程设计 家庭报警防盗报警系统设计 2016年6月 目录 一.设计要求 1.1传感器的简介 1.2报警系统发展的背景 1.3设计的目的、意义 1.4 报警系统的发展趋势 1.5 设计应解决的问题 二.设计内容 2.1设计原理 2.2设计的相关技术 2.3 实物的简介 三.硬件电路的设计 3.1主机电路设计 3.2 用户端传感器设计 3.3 蜂鸣器电路的设计

3.4电源电路设计四.软件设计 4.1 程序语言设计 4.2 报警装置的程序设计五.结论 六.参考文献 附录 附录1 附录2 附录3 附录4

一.设计要求 1.1传感器的简介 传感器(transducer/sensor)是一种检测装置,能感受到被测量的信息,并能将感受到的信息,按一定规律变换成为电信号或其他所需形式的信息输出,以满足信息的传输、处理、存储、显示、记录和控制等要求。 传感器的特点包括:微型化、数字化、智能化、多功能化、系统化、网络化,它不仅促进了传统产业的改造和更新换代,而且还可能建立新型工业,从而成为21世纪新的经济增长点。微型化是建立在微电子机械系统(MEMS)技术基础上的,已成功应用在硅器件上做成硅压力传感器。 在利用信息的过程中,首先要解决的就是要获取准确可靠的信息,而传感器是获取自然和生产领域中信息的主要途径与手段。 在现代工业生产尤其是自动化生产过程中,要用各种传感器来监视和控制生产过程中的各个参数,使设备工作在正常状态或最佳状态,并使产品达到最好的质量。因此可以说,没有众多的优良的传感器,现代化生产也就失去了基础。 目前,传感器早已渗透到诸如工业生产、宇宙开发、海洋探测、环境保护、资源调查、医学诊断、生物工程、甚至文物保护等等极其之泛的领域。可以毫不夸张地说,从茫茫的太空,到浩瀚的海洋,以至各种复杂的工程系统,几乎每一个现代化项目,都离不开各种各样的传感器。 1.2报警系统发展的背景 随着社会经济水平加速发展,人民生活状况也越来越好,于是大家就对住宅功能的要求有所提高,在有一个舒适,温暖的家的同时,还想有更多的功能,更安全的环境。但是,凡事有利必有弊,经济发展得快,也产生了一些负面影响,贫富差距开始扩大,流动人口也越来越多,盗窃,抢劫的案件也有所增加。这时,人们开始迫切需要一种能自动监控、自动报警的“电子保安”,对家庭安全进行保护。这样人们才既可以专心工作的,也可以避免损失。 早期的防盗报警器主要用于室内,随着报警技术的不断发展和完善,现在人们已研制出多种可用于室外做周界防范的报警器。如主动红外报警器、激光报警器、微波墙报警器、电场感应报警器、驻极体电缆报警器、泄漏电缆报器等等。它们各有特点,适合不同环境条件下采用,对防范场所的周界起报警探测作用。目前应用最多的是微波/被动红外双技术报警器。近年来报警领域里的一项最大成果是数字视频报警器的研制成功,数字视频报警器是随着数字电路技术、计算机技术和电视技术的发展而出现的一种新式报警器,它集电视监视与报警技术于一体,具有监视、报警、复核和图像记录取证多种功能,是当前一种最为先进的报警器。例如红外线是一种不可见光,有极强的隐蔽性和保密性,因此在安全警报等安全设备上得到广泛使用。大多数红外报警系统采用国外先进的技术,它的功能也非常先进。包括被动式热释电红外报警,也是本文研究的产品。 1.3本设计的目的、意义 报警器在现实生活中应用非常的广泛,家庭防盗,汽车安全防盗,企业内部安全保障,特别是金融行业等。一般传统式的报警器采用机械式的,如压电式报警器,当有入

家庭防盗报警系统设计

毕业设计(论文)报告 题目名称:家庭防盗报警系统设计 学生姓名:学号: 二级学院(系)/专业:能源与电气工程学院/楼宇智能化 班级:楼宇1313 指导教师: 2016年 5 月 17 日

摘要 21世纪的今天,科技日新月异,互联网信息技术迅速发展以及人们的物质生活水平大大提高,人们不仅仅对衣食行的要求提高,更是对住的要求更加提高,一个好的居住环境,能够让人们放松心情,释放压力更是对生活的一种高品质追求。与此同时,随着人们的保护意识不断提高,人们更加看重自身的财产安全。由此,家庭防盗报警系统而诞生。 本课题设计了家庭防盗报警系统,由家庭防盗报警主机,各种不同环境所使用的探测器,来满足人们对日常生活防盗的需求,使其生活更加愉悦,轻松。本设计选用现有的设备,为家庭设计合理的防盗措施,保证人们自身的财产安全。 关键词:防盗报警系统设计;红外报警系统

ABSTRACT 21 century, advances in technology, the Internet and the rapid development of information technology, people's living standards greatly improved, people not only for food and clothing line requirements increase, it is the requirement to live more improved, a good living environment that enables people to relax, release stress is a high quality of life pursuit. Meanwhile, with the continuous improvement of people's awareness of protection, people are more valued their property. Thus, the home security alarm system was born. This topic is designed home burglar alarm system, burglar alarm host a family, a variety of different environments detector used to meet the demand for security of daily life, making life more enjoyable and relaxed. The design uses existing equipment, designed for the home security measures, to ensure that people own property. Keywords: anti-theft alarm system, infrared alarm system

火灾自动报警设计说明标准格式

火灾自动报警设计总说明 一.工程概况:本项目位于核心地段,东临商业用地;南侧临路,对面为新建的中低档次的多层集资房和农民自建房; 西侧紧邻新区主干道 ,道路西侧为项目; 北侧路,对面是最大市民休闲广场广场。区域规划为未来市行政中心,市政府、市政广场、体育馆、图书馆、博物馆、银行等公共配套齐全。其中用地面积约为:万平方米,总建筑面积万平方米。 为大型城市综合体,含商业、餐饮、电影院、酒店、公寓等功能,建筑高度小于100米。地下一层为车库、变配电室、冷冻机房、发电机房、电话网络机房,等部分设备房,地下二层为地下车库、联通与移动通信机房、水泵房间等设备房;消防控制室设在一层;商业安保监控机房设置在商业的地下一层;酒店安保监控机房设置在酒店一层;同时在酒店四层分别设置电话、电脑机房专为酒店服务。 二.设计依据: 1.甲方提供的设计任务书、扩初有关批复文件及有关市政条件。 2.国家现行的有关规程、规范: 《工程建设标准强制性条文(房屋建筑部分)》(2002年版) GB50116-98 《火灾自动报警系统设计规范》 GB50045-95 《高层民用建筑设计防火规范》(2005版) GB50016-2006 《建筑设计防火规范》 GB50067-97 《汽车库、修车库、停车场设计防火规范》

GB50084-2001 《自动喷水灭火系统设计规范》第11章 GB50096-99 《住宅设计规范》(2003年版) GB50368-2005 《住宅建筑规范》(2005年版) JGJ 16-2008 《民用建筑设计规范》 3.建筑、结构、暖通、给排水等专业提供的设计资料。 三.设计范围及内容: 1.火灾自动报警系统。 2.联动控制系统。 3.消防广播系统。 4.消防电话系统。 5.火灾点亮及消防状态下非消防电源切除。 四.火灾自动报警系统设置: 1.本工程火灾自动报警为一级保护对象,采用控制中心报警系统。 2.设置范围:根据火灾自动报警系统设计规范,在地下停车库、商铺、公寓电梯前室、酒店电梯前室、客房、办公室。 3.楼梯间及设备机房等处设置火灾自动报警及联动控制系统。设置消防控制中心,协调管理小区火灾自动报警及联动控制系统。消防控制中心安装报警控制柜、消防联动控制柜、消防广播及消防专用电话系统控制柜。柜体采用柜式(落地安装)。地下室消防水池和屋顶水箱的液位反应到消防控制室。 4.报警系统采用无极性二总线技术,探测器选用智能型,以提高报警的可靠性。其中地下车库停车区设(差定温)感温探测器,分区域由

相关主题