SCREEN5055 报错速查表

SET FILM MAG 供片盒没装,装供片盒

SET COLLECT BOX 收片盒没装,装收片盒

CHANGE COL BOX 收片盒胶片没取完,将胶片取出

MA TERIAL EXIST 胶片位置错误,调整胶片位置

PLEASE CUT FILM 被排出的胶片留在机器内,执行CUT命令

PLEASE SET FILM 没装胶片,执行SET命令

PLEASE LOAD FILM 没装胶片,执行LOAD命令

FILM EMPTY 1 胶片用完,取出剩余胶片,装入新的胶片

FILM EMPTY 2 胶片用完,取出剩余胶片,装入新的胶片

SHUT THE DOOR 胶片用完,取出剩余胶片,装入新的胶片

RESTART DL-MIDE 重新启动DOWNLOAD模式

FILM EMPTY 3 胶片用完,取出剩余胶片,装入新的胶片

WIDTH NOT ENORGH 计算机设定的曝光宽度大于胶片宽度大于胶片宽度,请输入正确的数值

FAN 1 TROUBLE 进风扇1坏

FAN 2 TROUBLE 进风扇2坏

FAN 3 TROUBLE 进风扇3坏

FAN 4 TROUBLE 进风扇4坏

AFP POWER OFF 1 AFP 电源关上,请打开

AFP NOT READY AFP 正在启动,请稍等

AFP POWER OFF 2 AFP 停止,打开电源(备用)

AFP BUSY AFP正忙,请稍等

DOWNLOAD ERROR 下载任务失败

MODE MIXMA TCH 启动模式错误,检查MCON板上的DIP开关

CHANGE FILM MAG 更换胶片盒

PUNCH DUST FULL 打孔碎片满了,清理掉

IMPUT DA TA ERROR 输入数据不符合曝光条件,检查输入数据

LOADING ERROR 胶片在起始感应器位置错误,调整其位置

FILM FAM 1 胶片在中间感应器位置错误,调整其位置

FILM FAM 2 胶片在组合感应器位置错误,调整其位置

FILM FAM 3 胶片在排放感应器位置错误,调整其位置

FILM FAM 4 胶片停在排放感应器位置错误,调整其位置

FILM FAM 5 胶片在末端感应器位置错误,调整其位置

FILM FAM 6 胶片停在末端感应器位置错误,调整其位置

FILM FAM 7 胶片传送时收片盒没工作,调整其位置

FILM FAM 11 胶片停在排放感应器位置错误,调整其位置

FILM FAM 12 胶片在末尾感应器位置错误,调整其位置

FILM FAM 13 胶片停在末尾感应器位置错误,调整其位置

FILM FAM 14 胶片掉进A T单元,调整其位置

MACHINE ERROR 1 裁切部分错误(感应器都开或关)

MACHINE ERROR 2 裁切部分错误(前切感应器没打开)

MACHINE ERROR 3 裁切部分错误(后切感应器没打开)

MACHINE ERROR 4后缓冲导引错误(后缓冲导引感应器没关上,后缓冲导引没开)MACHINE ERROR 5后缓冲导引错误(后缓冲导引感应器没打开,后缓冲导引没关)MACHINE ERROR 6前缓冲导引错误(两个或多个前缓冲导引感应器都是打开的)MACHINE ERROR 7 前缓冲导引错误(当前缓冲导引打开时,感应器没开)

MACHINE ERROR 8前缓冲导引错误(当前缓冲导引关上时,感应器没开)MACHINE ERROR 9前缓冲导引错误(当前缓冲导引在REWIND位置时,感应器没开)MACHINE ERROR 10A T导引感应器没关上,A T导引感应器没关上,A T导引没开)MACHINE ERROR 11 A T导引感应器没关上,A T导引感应器没打开,A T导引没关)MACHINE ERROR 12 曝光过程错误(EXP-END信号没探测到)

MACHINE ERROR 13 ND转换单元错误(ND转换感应器没有打开或关上)MACHINE ERROR 14 起始曝光错误(页面信号没打开)

MACHINE ERROR 15 起始曝光错误(连线启动脉冲信号没探测到)

MACHINE ERROR 16 棱镜错误(没有探测到棱镜加速信号)

MACHINE ERROR 17 前缓冲棍探测传感器错误(感应器全开)

MACHINE ERROR 18 前缓冲棍探测传感器错误(当前缓冲棍抬起时,感应器没开)MACHINE ERROR 19 前缓冲棍探测传感器错误(当前缓冲棍下降时,感应器没关)MACHINE ERROR 20 前打孔单元错误(前打孔感应器没开,打孔单元不下降)MACHINE ERROR 21 前打孔单元错误(前打孔感应器没关,打孔单元不上升)MACHINE ERROR 22 尾打孔单元错误(前打孔感应器没开,打孔单元不下降)MACHINE ERROR 23 尾打孔单元错误(前打孔感应器没关,打孔单元不上升)

MACHINE ERROR 24 收片盒位置错误

MACHINE ERROR 30 电源接通时,机器初始化错误

STOP 按了停止键,操作停止

AFP ERROR 1 胶片在传接到冲机的过程中卡住

AFP ERROR 2 胶片在冲机里卡住

AFP ERROR 3 冲机马达停止

AFP ERROR 4 冲机门打开了,请关上

AFP ERROR 9 冲机显影温度错误

AFP ERROR 10 冲机定影温度错误

AFP ERROR 11 冲机烘干温度错误

AFP ERROR 12 冲机显影槽液面下降

AFP ERROR 13 冲机定影槽液面下降

AFP ERROR 14 冲机清洗液槽液面下降

AFP ERROR 17 冲机显影液补充槽液面下降

AFP ERROR 18 冲机定影液补充槽液面下降

AFP ERROR 19 冲机清洗液补充槽液面下降

AFP ERROR 20 冲机水补充槽液面下降

AFP ERROR 22 冲机废显影槽液面达到上限

AFP ERROR 23 冲机废定影槽液面达到上限

AFP ERROR 24 冲机废清洗槽液面达到上限

AFP WARNING 9 更换显影过滤器

AFP WARNING 10 更换定影过滤器

AFP WARNING 11 更换清洗过滤器1

AFP WARNING 12 更换清洗过滤器2

AFP WARNING 13 更换空气排空过滤器

SERIAL ERROR 11 AFP传输错误(AFP SIDE)

SERIAL ERROR 10 AFP传输错误(FT-R SIDE)

I/F ERROR 1 AFP信息传输错误(SCSI BUS),重启系统

SERIAL ERROR 01 界面单元RS信息传输错误,重启系统

SERIAL ERROR 00 MCON板的RS信息传输错误,重启系统

IMAGE ERROR SCSI信息传输错误(曝光图文先于硬盘读出数据),重启系统

I/F COM ERROR 1 SCSI信息传输错误(CDB参数错误),重启系统

I/F COM ERROR 2 SCSI信息传输错误(没出息接收到操作命令),重启系统

I/F COM ERROR 3 CDB错误(SCSI)重启系统

I/F ERROR 2 SCSI错误(逻辑单元除0都选择)任务

I/F ERROR 3 SCSI传输命令错误,重启系统

I/F ERROR 4 SCSI传输命令错误,重启系统

DISK**ERROR HDD错误

网屏5055常见故障与排除

故障一:突然初始化或初始化不过

处理办法:

①有可能PSI电源抵压、测量MCON板TP-AC和TB6的直流电压是否在4.8-5.3V范围内,如果没有就调节PSI板的VRI。

②有可能主板故障(MCON板),检查各电机、保险。

故障二:报“Machine eror15”错误

处理办法:

①检查激光头:在暗房观察光路是否有光(通常)高DPI(3000、2400)输出时只有短暂的光之后报错,用低DPI(1000、2000)能够输出大约A4幅面图像之后光消失并报错。通常这种情况都是激光头故障。

②检查激光感应器(Star sensor)如果光路有光并报错。检查“Star sensor”感应器是否位置不对或者是否有脏的东西挡住。

③MACON板坏。

故障三:图像扭曲

处理办法:

①五面镜的光不稳定,有跳跃。

②走片不稳:零件安装时不到位,时间长零件有磨损。

③TIF图形超过100m。

故障四:报“Machine error17、18、19或Load error”错误

处理办法:

①检查电机(Front slack guide motor)。

②检查“Front slack roller position”感应器状态以观察是否位置不对。

故障五:出黑线(方向是横的)

处理办法:

①由于滚轴脏引起,擦干净滚轴即可。

②地线不好,滚轴产生静电引起。

③工作电压不稳有很大的电压差跳跃。

④数据传递不稳(RIP机的内存、发排卡、硬盘都会有影响)。

故障六:5055S机报(Film jam 5)错

处理办法:

①供片盒转过头了,菲林进不去,在放入供片盒时,机器开始转动,如果最后听到“咔“的一声,机器一定是卡片,调节供片盒右边铝片的位置。

②供片盒架子变形。

③机器没有水平

故障七:5055报“Film jam 4”错

处理办法:

①机器没有水平。

②菲林没有上好。

故障八:Film走片方向有白条(较软)

处理办法:

①补偿镜有脏点。

②Shuter处有脏东西。

故障九:机器出白片,重出又消失,字有重影,图像移位

处理办法:更换主板上的B9110的芯片。

故障十:显示报警:SERIAL ERROR 11

原因:应为照排机与冲机之间的通讯错误。

处理:

①检查连线、电源(地线、电压)是否有问题。

②将照排机与冲机断开(将主控板上DIPSW开关6设为ON),单独试用,若仍报错,则应主板损坏的可能性较大。

故障十一:显示报警:MACHINE ERROR 30

原因:应为主板电源低于4.8 V造成。

现象:正在出片时,RECORDING 1%-100%突然消失,重新初始化INSTALLING…。

处理:在主控板上用电压表(直流)测量TP06--TPA02间电压值,看是否小于4.8V (正常为4.8V—5.3V)。若是,则在电源板上调节PS1(蓝点黄头的一个小螺丝,顺时针转,电压值调大),使主板电压为5V 。若无效,则考虑更换电源板。

故障十二:显示报警:MACHINE ERROR 24

原因:应为照排机和收片盒之间的齿轮吻合不好或感应器出问题。

处理:

①重新调整收片盒的位置。(指导)

②更换感应器。

故障十三:显示报警:AFP POWER OFF 1

原因:

①只启动了照排机而冲机未打开。(指导)

②主板上的插口OF111和OF112的插线插反。

③主板上的连线松动。

故障十四:显示报警:LOADING ERROR

原因:上片过程中产生错误。

处理:

①上片时胶片是否放置到胶辊的适当位置。(指导)

②检查主电机与主辊之间的连接运转是否正常。

故障十五:显示报警:WIDTH NOT ENOUGH

原因:胶片宽度与照排机的设置宽度不相符。

处理:照排机中设置最大549.9mm。在FILM菜单中更改设置。(指导)

故障十六:显示器报警:MACHINE ERROR 2

原因:前裁刀发生故障

处理:

①插头的位置是否插在ON 110。(对于初装的机器或旧机器更换主板之后)。

②检查裁刀的保险是ON 还是OFF,应为ON 。

③裁刀感应器的位置移动或感应器坏。

故障十七:显示器报警:MACHINE ERROR 15(12)

原因:开始曝光时,曝光信号太弱或感应器未感应到光信号。

处理:

①将光值调节提高、清洁光路、清洁感应器。(指导)

②行首感应器位置移动。

③主板坏或激光器坏。

故障十八:显示器报警:IMAGE ERROR

原因:数据信号传输通讯错误。

处理:

①检查SCSI接口以及接口板是否正确完好。

②对硬盘格式化(针对使用硬盘的客户)。

③更换新的硬盘(针对使用硬盘的客户)。

故障十九:照排机所出胶片上有黑线(极细的黑色线,沿走片方向),一条或多条。

原因:

①静电

②走片过程中胶片在进入定影液之前划伤。

处理:

①检查地线是否符合要求,有无松动接触不良现象。测量零地电压(要求小于3V)。

②对照排机的出片口进行清洁,对冲机的进片口位置进行清洁。处理为用蘸酒精的高级镜头纸或麂皮擦拭。

③对冲机的显影、定影、水洗辊子清洁。注意不要蹭伤底层的胶辊。

冲片机部分

故障一:冲片机一开机,显影灯就开始亮

处理办法:

①感应器处有脏点挡住了光,小心用干净布或棉花干净。

②感应器坏了。

故障二:实地内有很多白点

处理办法:定影混入显影,更换药液。

故障三:开机报“卡片”

处理办法:

①是否有菲林卡住造成电机不转。

②检查电机是否有电压,有电压,电机不转为电机坏。

③如果电机没电压到,为主板故障。

故障四:烘干部分有水或定影很容易混到显影里

处理办法:排水位比进水位高。

故障五:所出胶片上有黑线(多条位置基本固定的明显蹭伤)

原因:走片过程中胶片在进入定影液之前蹭伤。

处理:

①检查冲机中组辊边是否有齿轮位置移动或丢失现象

②对冲机的显影、定影、水洗辊子清洁。注意不要蹭伤底层的胶辊

备注:判断线条是否因冲片机或照排机引起。

1、手动冲片。

2、不同位置冲片。

3、把片反过来冲。

故障六:所出胶片上有白线

原因:胶片被划伤。

处理:对冲机的显影、定影、水洗辊子清洁。注意不要蹭伤底层的胶辊。

RIP、输出部分

故障一:不能拼版输出或不能解释大文件

处理办法:

①机器内存小。

②RIP的打印缓冲设置太小,应设16384MB。

③RIP软件分配内存小(最好是256以上)。

故障二:Illustrator发排的渐变效果很差

处理办法:

①选择Illustrator的[File]菜单里的[setup],然后选择[Compalible Gradient and Gradient Mesh Printing](使渐变机容)。

故障三:HQ-510能发排,方正PSP不能发排

处理办法:NT操作系统问题,格式化硬盘后重新安装NT

计算机网络故障处理与维护方法(毕业论文)

五年制高职商贸信息专业毕业论文 计算机网络故障处理与维护方法 班级 姓名 学号 指导老师

目录 【摘要】 (1) 一、计算机网络故障的分类 (1) (一)计算机网络物理故障 (4) (二)计算机网络逻辑故障 (3) 二、计算机网络常见故障的处理 (1) (一)本地连接断开 (1) (二)本地连接收限制或无连接 (1) (三)本地连接正常,但浏览器无法连接网页 (1) 三、如何加强网络的维护 (1) (一)概括的说,应做到: (4) (二)具体来说,应该做到: (3) 四、结论 (8) 【参考文献】 (3)

计算机网络故障处理与维护方法 【摘要】 本文就网络中常见故障进行分类,针对各种常见网络故障提出相应的解决方法,并就如何加强网络的维护进行了概括论述。 网络出现故障是极普遍的事,其种类也多种多样,在网络出现故障时对出现的问题及时进行维护,以最快的速度恢复网络的正常运行,掌握一套行之有效的网络维护理论方法和技术是至关重要的。 【关键词】 网络故障分类处理维护 一、计算机网络故障的分类 计算机网络故障主要是指,用户在使用计算机网络过程中或网络在运行过程中出现的问题,导致计算机网络不能正常使用。通常计算机网络故障可以按照其故障的性质,分为物理故障和逻辑故障。 (一)物理故障: 物理故障也就是硬件故障,一般是指网络设备或线路损坏、接口松动、线路受到严重干扰,以及因为人为因素导致的网络连接错误等情况。出现该类故障时,通常表现为网络断开或时断时续。物理故障主要包括: (1)线路故障

线路故障的发生率在日常的网络维护中非常高,约占发生网络故障的60%~70%。线路故障包括线路的损坏和线路受到严重干扰。 (2)接口故障 接口故障通常包括插头松动和端口本身的物理损坏。如:双绞线RJ45接头的损坏。 (3)交换机或路由器故障 交换机或路由器故障在这里是指设备出现物理损坏,无常工作,导致网络不能正常运行的情况。 (4)网卡故障 网卡也称网络适配器,大多安装在计算机的主机部。通过主机完成配置和。网卡故障主要包括网卡松动、主机网卡插槽故障、网卡本身物理故障等。 (二)逻辑故障: 逻辑故障也称为软件故障,主要是指软件安装或网络设备配置错误所引起的网络异常。与硬件故障相比,逻辑故障往往要复杂得多。常见的网络逻辑故障有:主机逻辑故障、进程或端口故障、路由器故障等。 (1)主机逻辑故障 主机逻辑故障通常包括网卡驱动程序、网络通信协议或服务安装不正确、网络地址参数配置有误等。对计算机网络用户来讲,该类故障是十分常见的网络故障之一。 (2)进程或端口故障 进程或端口故障是指一些有关网络连接的进程或端口由于受到病毒或系统

横河压力变送器常见故障处理方法

2、典型故障的处理方法 2.1 对测量超限的处理方法通过研究分析,发现此类故障通常与以下因素有关:① 仪表操作使用不当以抚顺石油一厂酮苯装置 C-101液位控制系统(LICA-1201)为例,如图1所示,由于仪表始终在高液位(100%以上)运行,或仪表始终在低液位(5%以下)运行,都有可能使仪表指示为超限。因此,要求工艺操作人员应能根据工艺流程及工艺控制要求正确判断出是仪表故障还是工艺操作不当。所以,需要工艺人员和仪表维护人员密切配合,保证工艺介质在仪表所能测量范围内,避免使操作人员误认为仪表故障。 图1 C-101 液位控制系统工艺图②仪表量程选择不当在对该厂酮苯装置中EJA 智能双法兰变送器测量量程检查时,均发现变送器量程存在设计计算错误,如对LICA-1201等变送器在DCS工程师站上检查它们的量程时,发现双法兰量程无迁移,这是造成仪表测量不准及超限的重要原因,如图2所示。 图2 塔101 量程计算参数图原设计采用量程为0~19.71kPa,无量程迁移,因此测量结果在仪表量程之外,出现测量超限情况。实际上对此台仪表应按下面的方法进行量程计算:已知:仪表可测范围,介质比重,毛细管硅油比重。求仪表量程。求解方法:仪表的量程是指当液位由最低升到最高时,液面计上所受的压力,故量程为:当液面最低时,液面计正、负压室的受力为:液面计迁移量为: =-2.65=-2.65×1.07×9.81 =-27.82kPa P+>P-,故为负迁移。按上述计算修改量程后,仪表运行即正常。因此,只有按正确的计算方法及引用迁移量来进行计算才能保证仪表量程的准确。 2.2 安全柵不配套造成仪表无输出及测量不准由于智能变送器要求使用与之配套的安全柵,当用了未取得与智能变送器配套许可证的安全柵后,大部分都会出现这样那样的问题,其主要故障有:①安全柵电

网络维护及常见故障排除

网络维护及常见故障排除 第一章排除故障过程 1.1识别故障现象 在你排故障之前,也必须确切地知道网络上到底出了什么毛病,是不能共享资源,还是找不到另一台计算机,如此等等。知道出了什么问题并能够及时识别,是成功排除故障最重要的步骤。为了与故障现象进行对比,你必须知道系统在正常情况下是怎样工作的,反之,你是不好对问题和故障进行定位的。 识别故障现象时,应该向操作者询问以下几个问题: (1)当被记录的故障现象发生时,正在运行什么进程(即操作者正在对计算机进行什么操作)。 (2) (2)这个进程以前运行过吗? (3)(3)以前这个进程的运行是否成功? (4) (4)这个进程最后一次成功运行是什么时候? (5)(5)从那时起,哪些发生了改变? (6)带着这些疑问来了解问题,才能对症下药排除故障。 1.2对故障现象描述 当处理由操作员报告的问题时,对故障现象的详细描述显得尤为重要。如果仅凭他们的一面之词,有时还很难下结论,这时就需要你亲自操作一下刚才出错的程序,并注意出错信息。对此在排除故障前,可以按以下步骤执行: (1)收集有关故障现象的信息; (2)对问题和故障现象进行详细描述; (3)注意细节; (4)把所有的问题都记下来; (5)不要匆忙下结论。

第二章网络故障原因 2.1 网络连通性故障 1、故障表现 连通性故障通常表现为以下几种情况: ①计算机无法登录到服务器; ②计算机无法通过局域网接入Internet; ③计算机在"网上邻居"中只能看到自己,而看不到其他计算机,从而无 使用其他计算机上的共享资源和共享打印机 ④计算机无法在网络内实现访问其他计算机上的资源; 2、故障原因 以下原因可能导致连通性故障: ①网卡未安装,或未安装正确,或与其他设备有冲突; ②网卡硬件故障; ③网络协议未安装 ④IP地址设置错误; ⑤网线、信息模块故障; 3、排除方法 ①确认连通性故障 当出现一种网络应用故障时,如无法接入Internet,首先尝试使用其他网络应用,如查找网络中的其他计算机,或使用局域网中的Web浏览等。如果其他网络应用可正常使用,如虽然无法接入Internet,却能够在"网上邻居"中找到其他计算机,或可ping到其他计算机,即可排除连通性故障原因。如果其他网络应用均无法实现,继续下面操作。 ②用ping命令排除网卡故障 使用ping命令,ping本地的IP地址或计算机名,检查网卡和IP网络协议是否安装完好。如果能ping通,说明该计算机的网卡和网络协议设置都没有问题。 因此,应当检查网线和交换机的接口状态,如果无法ping通,只能说明TCP/IP协议有问题。这时可以在计算机的"控制面板"的"系统"中,查看网卡是否已经安装或是否出错。如果在系统中的硬件列表中没有发现网络适配器,或网络

系统报错信息表

Asia Pacific Choose A Country/Region 窗体顶端 Asia Pacific 窗体底端 Products S upport C ommunity Support Home Page User Guide 返回目录页面 关于系统 Dell? PowerEdge? R710 系统 硬件用户手册 在启动过程中访问系统功能 前面板部件和指示灯 LCD 面板部件 RAID 硬盘驱动器指示灯的显示方式 背面板部件和指示灯 电源指示灯代码 NIC 指示灯代码 LCD 状态信息 系统信息 警告信息 诊断程序信息 警报信息 可能需要的其它信息 在启动过程中访问系统功能

前面板部件和指示灯 图1-1. 前面板部件和指示灯(2.5 英寸机箱) 图1-2. 前面板部件和指示灯(3.5 英寸机箱)

LCD 面板部件 系统的LCD 面板可以提供系统信息和状态信息,以表示系统何时运行正常或何时需要注意。有关特定状态代码请参阅"LCD 状态信息"。 系统正常运行期间LCD 背景光将呈蓝色亮起,呈琥珀色亮起时表示发生故障状态。当系统处于待机模式时,L 光不亮,通过按LCD 面板上的Select(选择)按钮,可以打开背景光。如果通过iDRAC 公用程序、LCD 面板工具关闭了LCD 信息显示,LCD 背景光就会保持不亮状态。 图1-3. LCD 面板部件

主屏幕 主屏幕显示用户可配置的系统相关信息。在系统正常运行过程中,如果没有状态信息或错误出现,就会显示此屏系统处于待机状态时,如果没有任何错误信息,LCD 背景光将在不活动五分钟之后关闭。按下三个导航按钮(选左、向右)中的任何一个,即可查看主屏幕。 若要从其它菜单导航至主屏幕,则连续选择向上箭头,直到显示主屏幕图标,然后选择该图标。 从主屏幕开始,按Select(选择)按钮,进入主菜单。请参阅下面的表格,了解关于Setup(设置)和View(查菜单的信息。 设置菜单 注:当选择Setup(设置)菜单中的选项时,系统将会要求您确认该选项,然后才能继续操作。

智能电磁流量计常见故障分析及解决

智能电磁流量计常见故障分析及解决智能电磁流量计是一种速度式仪表。除可测量一般导电液体的体积流量外,还可用于测量强酸强碱等强腐蚀液体和泥浆、矿浆、纸浆等均匀的液固两相悬浮液体的体积流量。广泛应用于石油、化工、冶金、轻纺、造纸、环保、食品等工业部门及市政管理,水利建设、河流疏浚等领域的流量计量。常见故障,有的是由于仪表本身元器件损坏引起的故障,有的是由于选用不当、安装不妥、环境条件、流体特性等因素造成的故障,如显示波动、精度下降甚至仪表损坏等。它一般可以分为两种类型:安装调试时出现的故障(调试期故障)和正常运行时出现故障(运行期故障)。 (1)调试期故障调试期待故障一般出现在仪表安装调试阶段,一经排除,在以后相同条件下一般不会再出现。常见的调试期故障一般由安装不妥、环境干扰以及流体特性影响等原因引起。 1)安装方面通常是智能电磁流量计传感器安装位置不正确引起的故障,常见的如将传感器安装在易积聚气体的管系最高点;或安装在自上而下的垂直管上,可能出现排空;或传感器后无背压,流体直接排入大气而形成测量管内非满管。 2)环境方面通常主要是管道杂散电流干扰,空间强电磁波干扰,大型电机磁场干扰等。管道杂散电流干扰通常采取良好的单独接地保护就可获得满意结果,但如遇到强大的杂散电流如电解车间管道,有时在两电极上感应的交流电势峰值可高达尚需采取另外措施和流量传感器与管道绝缘等。空间电磁波干扰一般经信号电缆引入,通常采

用单层或多层屏蔽予以保护。 3)流体方面被测液体中含有均匀分布的微小气泡通常不影响电磁流量计的正常工作,但随着气泡的增大,仪表输出信号会出现波动,若气泡大到足以遮盖整个电极表面时,随着气泡流过电极会使电极回路瞬间断路而使输出信号出现更大的波动。 低频方波励磁的电磁流量计测量固体含量过多浆液时,也将产生浆液噪声,使输出信号产生波动。 测量混合介质时,如果在混合未均匀前就进入流量传感进行测量,也将使输出信号产生波动。 电极材料与被测介质选配不当,也将由于化学作用或极化现象而影响正常测量。应根据仪表选用https://www.sodocs.net/doc/8316704201.html,或有关手册正确选配电极材料。 (2)运行期故障运行期故障是智能电磁流量计经调试并正常运行一段时期后出现的故障,常见的运行期故障一般由流量传感器内壁附着层、雷电打击以及环境条件变化等因素引起。 1)传感器内壁附着层由于电磁流量计常用来测量脏污流体,运行一段时间后,常会在传感器内壁积聚附着层而产生故障。这些故障往往是由于附着层的电导率太大或太小造成的。若附着物为绝缘层,则电极回路将出现断路,仪表不能正常工作;若附着层电导率显著高于流体电导率,则电极回路将出现短路,仪表也不能正常工作。所以,应及时清除电磁流量计测量管内的附着结垢层。 2)雷电打击雷击容易在仪表线路中感应出高电压和浪涌电流,使

医院网络维护常见网络故障及排除技巧

龙源期刊网 https://www.sodocs.net/doc/8316704201.html, 医院网络维护常见网络故障及排除技巧 作者:王唯 来源:《科学与信息化》2018年第04期 摘要随着近两年来社会经济以及网络信息技术的不断发展,医院信息化建设的进程也越来越快。网络维护作为医院信息化建设过程中非常重要的内容,通过对医院网络系统运行过程中所存在的故障进行排除,不仅可以有效提高医院网络的运行效率,与此同时也能大大提高医院经济效益。医院作为信息资料十分丰富的场所,网络信息技术在医院管理过程中的应用有效提高了信息数据的传送以及保存效率,同时也为医院工作人员大大节省了工作时间和精力。但随着医院信息化建设的不断发展,网络故障问题也频繁出现,这些故障不仅造成了信息数据的丢失,并且给一些不法分子的病毒入侵提供了便利,基于这些情况,相关医院管理人员应该要加强对各部门工作程序的管控,通过科学、合理的方式对网络故障进行有效排除,从而促进医院信息化发建设的良好发展。 关键词医院网络维护;常见故障;排除技巧 Abstract with the continuous development of social economy and network information technology in the past two years, the process of hospital information construction has been getting faster and faster. Network maintenance as a very important content in the process of hospital information construction, through the hospital network system of faults in the operation process,not only can effectively improve the efficiency of the operation of the hospital network, at the same time also can greatly improve the hospital economic benefit. Hospital as a place of information is very rich, the network information technology application in the process of hospital management improve the efficiency of data transmission and preservation, as well as hospital staff work greatly saves time and energy. But with the continuous development of hospital informationization construction,network fault problem also appeared frequently, these failures not only caused the loss of information data, and gives some criminals network intrusion is convenient, based on these conditions, related to hospital managers should strengthen the control of various departments work procedures, through the scientific and reasonable way to effectively eliminate of network failure,so as to promote the development of the construction of hospital informatization. Keywords Hospital network maintenance; Common failures; Rule out skills 随着网络信息技术的不断进步,医院信息化建设也有了良好的发展趋势。但根据相关调查结果显示,我国部分医院管理人员还没有正确地意识到网络维护的重要性,在医院网络运行过程往往会出现各种故障问题,这些问题在一定程度也严重影响医院信息化建设的发展。因此,相关医院管理人员应该要加强对内部网络的维护和管理,通过对网络运行过程出现故障进行有效排除,从而确保医院网络系统能够安全、稳定运行。另外,医院网络管理过程中相关维护人员应该要充分掌握好各种常见网络故障的排除方法,这样便可以及时、高效地解决各种突发故

数据库项目组日常运维与应急故障处理手册范本

常见问题及处理方案 CPU使用率高的问题 通过操作系统命令top topas glance等查看top进程号,确认是系统进程还是oracle应用进程,查询当前top进程执行的操作和sql语句进行分析。 根据进程号获取正在执行的sql SELECT a.osuser, https://www.sodocs.net/doc/8316704201.html,ername,b.address,b.hash_value, b.sql_text from v$session a, v$sqltext b, v$process p where p.spid = &spid and p.addr = a.paddr and a.STATUS = 'ACTIVE' and a.sql_address =b.address order by address, piece; 数据库无法连接 数据库无法连接,一般可能是如下原因造成: (1)数据库宕了 (2)监听异常 (3)数据库挂起 (4)归档目录满 (5)数据库或应用主机的网卡出现问题不能正常工作 (6)应用主机到数据库主机的网络出现问题。 1、数据库宕了 立即启动数据库。 2、监听异常 此时一般体现为: 监听进程占用CPU资源大; 监听日志异常。 此时,立即重启监听,监听重启一般能在1分钟之完成。 3、数据库挂起 立即重启数据库。 4、归档目录满 (1)在没有部署OGG数据同步的情况下,立即清理归档日志文件。

(2)如果部署了OGG数据同步,查看OGG正在读取的归档日志文件,立即 清理OGG不再需要的日志文件。 5、数据库或应用主机的网卡出现问题不能正常工作。 立即联系主机工程师处理。 6、应用主机到数据库主机的网络出现问题。 立即联系网络维护人员查看。 CRS/GI无法启动 对于10g及11gR1版本的CRS问题 1、进入/tmp目录下,看是否产生了crsctl.xxxxx文件 如果有的话,看文件容,一般会提示OCR无法访问,或者心跳IP无法 正常绑定等信息。 2、如果/tmp目录下没有crsctl.xxxxx文件 此时查看ocssd.log文件,看是否能从中得到有价值的信息。 可能的问题:网络心跳不通。 3、/tmp目录无crsctl.xxxxx且日志中没有报错信息,只有停CRS时的日志信 息。 此时可能是RAC两个节点对并发裸设备的访问有问题,此时考虑: (1)停掉两个节点的CRS。 (2)两个节点先同时去激活并发VG,然后再激活VG。 (3)重新启动CRS。 对于11gR2的GI问题 分析$GRID_HOME/log/nodename目录下的日志文件,看是否能从中找出无法启动的原因。常见问题: 1、心跳IP不同。 2、ASM实例无法启动。 对CRS的故障诊断和分析,参加本文档中RAC部分的MOS文档. 数据库响应慢

常见仪表常见故障及处理办法

仪表常见故障检查及分析处理 一、磁翻板液位计: 1、故障现象:a、中控远传液位和现场液位对不上或者进液排液时液位无变化;b、现场液位计和中控远传均没有问题的情况下,中控和现场液位对不上; 2、故障分析:a、在确定远传液位准确的情况下,一般怀疑为液位计液相堵塞造成磁浮子卡住,b、现场液位变送器不是线性; 3、处理办法:a、关闭气相和液相一次阀,打开排液阀把内部液体和气体全部排干净,然后再慢慢打开液相一次阀和气相一次阀,如果液位还是对不上,就进行多次重复的冲洗,直到液位恢复正常为止;b、对液位计变送器进行线性校验。 二、3051压力变送器:压力变送器的常见故障及排除 1)3051压力变送器输出信号不稳 出现这种情况应考虑A.压力源本身是一个不稳定的压力B.仪表或压力传感器抗干扰能力不强C.传感器接线不牢D.传感器本身振动很厉害E.传感器故障 2)加压变送器输出不变化,再加压变送器输出突然变化,泄压变送器零位回不去,检查传感器器密封圈,一般是因为密封圈规格原因(太软或太厚),传感器拧紧时,密封圈被压缩到传感器引压口里面堵塞传感器,加压时压力介质进不去,但是压力很大时突然冲开密封圈,压力传感器受到压力而变化,而压力再次降低时,密封圈又回位堵住引压口,残存的压力释放不出,因此传感器零位又下不来。排除此原

因方法是将传感器卸下看零位是否正常,如果正常更换密封圈再试。 3)3051压力变送器接电无输出 a)接错线(仪表和传感器都要检查) b)导线本身的断路或短路 c)电源无输出或电源不匹配 d)仪表损坏或仪表不匹配 e)传感器损坏 总体来说对3051压力变送器在使用过程中出现的一些故障分析和处理主要由以下几种方法。 a)替换法:准备一块正常使用的3051压力变送器直接替换怀疑有故障的这样可以简单快捷的判定是3051压力变送器本身的故障还是管路或其他设备的故障。 b)断路法:将怀疑有故障的部分与其它部分分开来,查看故障是否消失,如果消失,则确定故障所在,否则可进行下一步查找,如:智能差压变送器不能正常Hart远程通讯,可将电源从仪表本体上断开,用现场另加电源的方法为变送器通电进行通讯,以查看是否电缆是否叠加约2kHz的电磁信号而干扰通讯。 c)短路检测:在保证安全的情况下,将相关部分回路直接短接,如:差变送器输出值偏小,可将导压管断开,从一次取压阀外直接将差压信号直接引到差压变送器双侧,观察变送器输出,以判断导压管路的堵、漏的连通性 三、雷达液位计:

网络常见故障维修

网络常见故障处理方法 1.网络突然中断 网卡IP地址的设置错误 右键点击网上邻居,在弹开菜单中选择属性,然后继续右键点击本地网络,在弹开菜单中选择属性,进入本地连接属性栏,之后双击INTERNET协议( TCP/IP),可才看到自己的IP地址,子网掩码,DNS等相关设置。 在公司内部每个人的地址多不相同,如果你的地址与别人的相同,就会造成 IP地址冲突,导致上不去网络;而且配置与网关给的配置不一样,也有上不去网络 的可能。 网卡误操作被禁用 网卡被禁用后,在右下角将没有连接提示,需要用右键点击网络邻居,在弹开菜单中选择属性,然后继续右键点击本地网络,在弹开菜单中选择启用。 网线接触不良,网卡插错或插的不严实 这类故障通常因为设备的老化或者网络头的磨损导致的,这类故障要彻底解决的话需要更换交换机或者更换网络头。 交换机停止工作 通常是有人不小心碰到了电源,导致设备断电。通常这种情况发生,会导致掉电设备上所有的用户多会中断与网络的连接。 电脑中了恶性病毒 电脑在中病毒后,通常情况是系统运行速度变慢,上网速度也变的缓慢;当电脑中一些恶性病毒后,病毒会对一些常用端口发病毒包,从而导致电脑上不去网或 者一些软件无法正常使用。 2.网络正常,邮件收发有问题

邮件服务器设置错误 邮件服务一般需要用户设置SMTP服务器,POP3服务器以及用户名和密码;其中SMTP服务器是发件服务器,邮件的收发多是通过该服务器来发送,POP3服务器是收 件服务器,你收到的邮件多是从POP3服务器上传送到本地的。如果用户更改设置后,发现邮件能收不能发,或者邮件能发不能收,只需要查看响应的服务器设置就可以。 电脑操作系统故障导致邮件收发出现问题 ???此类故障主要因为电脑配置,系统稳定性所导致。当电脑配置教低,系统稳定性又很差时,电脑经常出现各种故障,有时出现突然邮件收发出现问题;一般此类问题解决方法就是重启操作系统。 邮件提供商的配置问题 当您在一个地方使用邮件服务很正常,换到另外一个地点后,邮件服务突然出 现问题,而上网正常,很又可能是邮件提供商或者当地的网络提供商对网络进行了一些安全设置,所以这时你需要联系邮件提供商或者当地的网络提供商来处理此类问题。 3.网络时断时续,很不稳定 ???当网络配置完后,发现网络时断时续,首先我们需要查看我们的路由等设备配置,查看网络设备配置上是否有任何问题。 ???如果网络时断时续是网络正常运行一段时候后才发生的,那我们需要查看路由设备的CPU利用率等相关数据,以此来确定是否问题来源于内部网络病毒。 ???如果确认上面那些多没有问题,那我们需要联系我们的网络提供商,一起配合检查线路。 4.网络故障查询经常使用的命令 Ping命令的使用技巧 ???Ping是个使用频率极高的实用程序,用于确定本地主机是否能与另一台主机交换(发送与接收)数据报。根据返回的信息,我们就可以推断TCP/IP参数是否设置得正确以及运行是否正常. Ping命令的常用参数选项: ???ping IP –t 连续对IP地址执行Ping命令,直到被用户以Ctrl+C中断。

网屏5055维修手册(一)

网屏5055维修手册(一) 剑神FT-R5055激光照排机报错对应表 1 SET FILM MAG 供片盒没装,装供片盒 2 SET COLLECT BOX 收片盒没装,装收片盒 3 CHANGE COL BOX 收片盒胶片没取完,将胶片取出 4 MATERIAL EXIST 胶片位置错误,调整胶片位置 5 PLEASE CUT FILM 被排出的胶片留在机器内,执行CUT命令 6 PLEASE SET FILM 没装胶片,执行SET命令 7 PLEASE LOAD FILM 没装胶片,执行LOAD命令 8 FILM EMPTY1 胶片用完,取出剩余胶片,装入新的胶片 9 FILM EMPTY2 胶片用完,取出剩余胶片,装入新的胶片 10 SHUT THE DOOR 胶片用完,取出剩余胶片,装入新的胶片 11 RESTART DL-MIDE 重新启动DOWNLOAD模式 12 FILM EMPTY3 胶片用完,取出剩余胶片,装入新的胶片 13 WIDTH NOT ENORGH 计算机设定的曝光宽度大于胶片宽度大于胶片宽度,请输入正确的数值 14 FAN1 TROUBLE 进风扇1坏 15 FAN2 TROUBLE 进风扇2坏 16 FAN3 TROUBLE 进风扇3坏 17 FAN4 TROUBLE 进风扇4坏 18 AFP POWER OFF1 AFP 电源关上,请打开 19 AFP NOT READY AFP 正在启动,请稍等 20 AFP POWER OFF2 AFP 停止,打开电源(备用) 21 AFP BUSY AFP正忙,请稍等 22 DOWNLOAD ERROR 下载任务失败 23 MODE MIXMATCH 启动模式错误,检查MCON板上的DIP开关 24 CHANGE FILM MAG 更换胶片盒 25 PUNCH DUST FULL 打孔碎片满了,清理掉 26 IMPUT DATA ERROR 输入数据不符合曝光条件,检查输入数据 27 LOADING ERROR 胶片在起始感应器位置错误,调整其位置 28 FILM FAM1 胶片在中间感应器位置错误,调整其位置 29 FILM FAM2 胶片在组合感应器位置错误,调整其位置 30 FILM FAM3 胶片在排放感应器位置错误,调整其位置 31 FILM FAM4 胶片停在排放感应器位置错误,调整其位置 32 FILM FAM5 胶片在末端感应器位置错误,调整其位置 33 FILM FAM6 胶片停在末端感应器位置错误,调整其位置 34 FILM FAM7 胶片传送时收片盒没工作,调整其位置 35 FILM FAM11 胶片停在排放感应器位置错误,调整其位置 36 FILM FAM12 胶片在末尾感应器位置错误,调整其位置 37 FILM FAM13 胶片停在末尾感应器位置错误,调整其位置 38 FILM FAM14 胶片掉进AT单元,调整其位置 39 MACHINE ERROR1 裁切部分错误(感应器都开或关) 40 MACHINE ERROR2 裁切部分错误(前切感应器没打开) 41 MACHINE ERROR3 裁切部分错误(后切感应器没打开) 42 MACHINE ERROR4 后缓冲导引错误(后缓冲导引感应器没关上,后缓冲导引没开) 43 MACHINE ERROR5 后缓冲导引错误(后缓冲导引感应器没打开,后缓冲导引没关) 44 MACHINE ERROR6 前缓冲导引错误(两个或多个前缓冲导引感应器都是打开的)

网屏照排机5055报错信息

NO MESSAGE CONTENTS 1SET FILM MAG 供片盒没装,装供片盒2SET COLLECT BOX 收片盒没装,装收片盒3CHANGE COL. BOX 收片盒胶片没取完,将胶片取出4MATERIAL EXIST 胶片位置错误,调整胶片位置 5PLEASE CUT FILM 被排出的胶片留在机器内,执行CUT命令6PLEASE SET FILM 没装胶片,执行SET命令7PLEASE LOAD FILM 没装胶片,执行LOAD命令 8FILM EMPTY1 胶片用完,取出剩余胶片,装入新的胶片9FILM EMPTY2 胶片用完,取出剩余胶片,装入新的胶片 10SHUT THE DOOR 胶片用完,取出剩余胶片,装入新的胶片11RESTART DL-MODE 重新启动DOWNLOAD模式 12FILM EMPTY3 胶片用完,取出剩余胶片,装入新的胶片13WIDTH NOT ENOUGH 计算机设定的曝光宽度大于胶片宽度,请输入正确的数值14FAN1 TROUBLE 进风扇1坏15FAN2 TROUBLE 进风扇2坏16FAN3 TROUBLE 进风扇3坏17FAN4 TROUBLE 进风扇4坏18AFP POWER OFF1 AFP电源关上,请打开19AFP NOT READY AFP 正在启动,请稍等20AFP POWER OFF2AFP 停止,打开电源(备用)21AFP BUSY AFP 正忙,请稍等 22DOWNLOAD ERROR 下载任务失败 23MODE MISMATCH 启动模式错误,检查MCON板上的DIP开关24CHANGE FILM MAG 更换胶片盒25PUNCH DUST FULL 打孔碎片满了,清理掉26IMPUT DATA ERROR 输入数据不符和曝光条件,检查输入数据27LOADING ERROR 胶片在起始感应器位置错误,调整其位置28FILM JAM1 胶片在中间感应器位置错误,调整其位置29FILM JAM2胶片在组合感应器位置错误,调整其位置30FILM JAM3胶片在排放感应器位置错误,调整其位置31FILM JAM4胶片停在排放感应器位置错误,调整其位置32FILM JAM5胶片在末端感应器位置错误,调整其位置 33FILM JAM6胶片停在末端感应器位置错误,调整其位置34FILM JAM7胶片传送时收片盒没工作,调整其位置35FILM JAM11胶片停在排放感应器位置错误,调整其位置36FILM JAM12胶片在末尾感应器位置错误,调整其位置37FILM JAM13胶片停在末尾感应器位置错误,调整其位置38FILM JAM14胶片掉进AT单元,调整其位置39MACHINE ERROR1 裁切部分错误(感应器都开或关)40MACHINE ERROR2裁切部分错误(前切感应器没打开)41MACHINE ERROR3裁切部分错误(后切感应器没打开)42MACHINE ERROR4后缓冲导引错误(后缓冲导引感应器没关上,后缓冲导引没开)43MACHINE ERROR5后缓冲导引错误(后缓冲导引感应器没打开,后缓冲导引没关)44MACHINE ERROR6前缓冲导引错误(两个或多个前缓冲导引感应器都是打开的)45MACHINE ERROR7前缓冲导引错误(当前缓冲导引打开时,感应器没开)46MACHINE ERROR8前缓冲导引错误(当前缓冲导引关上时,感应器没开)47MACHINE ERROR9前缓冲导引错误(当前缓冲导引在REWIND位置时,感应器没开)48MACHINE ERROR10AT导引错误(AT导引感应器没关上,AT导引没开)49MACHINE ERROR11AT导引错误(AT导引感应器没打开,AT导引没关)50 MACHINE ERROR12曝光过程错误(EXP-END 信号没探测到) 剑神5055报错指示 h t t p : //s c r e e n h k . t a o b a o . c o m

Oracle数据库常见异常的诊断方法

目录 第1章 Oracle数据库常见问题诊断方法 (1) 1.1 常见错误篇 (1) 1.1.1 ORA-12571、ORA-03113、ORA-03114、ORA-01041 (1) 1.1.2 ORA-01000 (1) 1.1.3 ORA-01545 (2) 1.1.4 ORA-0165x (2) 1.1.5 ORA-01555 (3) 1.1.6 ORA-04031 (3) 1.1.7 ORA-04091 (3) 1.1.8 ORA-01242、ORA-01113 (4) 1.2 内部错误篇 (4) 1.2.1 ORA-00600【12330】错误 (4) 1.2.2 ORA-00604【xxx】错误 (5) 1.2.3 ORA-00600【3339】错误 (5) 1.2.4 ORA-00600【13004】错误 (5) 1.3 分布式事务篇 (6) 1.3.1 诊断分布式事务 (6) 1.3.2 检查其它节点的事务(DBA_2PC_NEIGHBORS) (6) 1.3.3 通过DBA_2PC_PENDING字典表检查事务的状态 (6) 1.3.4 检查处理结果 (7) 1.3.5 COMMIT FORCE或ROLLBACK FORCE命令 (7) 1.4 OPS或RAC篇 (8) 1.4.1 准备工作 (8) 1.4.2 紧急情况下的状态备份 (8) 1.4.3 OPS设计、配置准则 (9) 1.4.4 OPS常见问题 (9) 1.4.5 诊断分析步骤 (9) 1.5 非OPS篇 (18) 1.5.1 ORACLE数据库系统常见问题:空间方面问题 (18) 1.5.2 ORACLE数据库系统常见问题:性能方面问题 (18) 1.5.3 ORACLE数据库系统常见问题:锁争用方面问题 (19) 1.5.4 ORACLE数据库系统常见问题:内存方面问题 (20) 1.5.5 ORACLE问题分析脚本 (20) 1.5.6 SQL*NET篇 (24) 1.5.7 TNS-12154 Error 或ORA-12154 (24) 1.5.8 NL-00462 Error 或ORA-00462 (25) 1.5.9 NL-00405 Error 或ORA-00405 (26)

电气仪表基本类型及常见故障的维修技术

电气仪表基本类型及常见故障的维修技术 摘要:随着科学技术的不断发展,自动化特征已经愈加明显,电气仪表作为实 现自动化的基础,提升其工作效率,加强故障维修工作十分重要。要发挥电气仪 表的作用,要从了解电气仪表的基本类型开始,只有对电气仪表进行充分的了解,才能够明确仪表出现故障的原因,能够在最短的时间内对故障进行排查并且解决。本文对电气仪表的基本类型进行了阐述,并且对常见故障的维修技术进行了讨论。 关键词:电气仪表;仪表类型;故障;维修技术 引言:在工业自动化生产过程中,电气仪表既是基础组成部分,也是自动化 过程中的重要组成部分。由于在其工作过程中经常会受到许多外力的影响,在发 生故障后,很难排查出引起故障的因素,所以,也就会延长技术人员排查故障的 时间,可能会影响到工业生产的进度。因此,只有利用合理的方式明确电气仪表 的基础类型和运行原理,才能够精准的排查出产生故障的因素,能够将排查故障 和维修故障的时间尽可能的缩小,进而实现工业生产的经济效益。 一、电气仪表的基本类型 电气仪表的类型有很多,但是现今应用范围最广的集中仪表主要有:流量仪表、压力仪表、液位仪表、温度仪表等,本文就其中的几种仪表进行了分析,压 力仪表的主要作用是对具体的环境指标做出测量,并且根据不同的压力仪表数据 来确定出不同种类压力仪表的工作原理,其测量对象主要包括粉状材料和高温材 料等等,压力仪表又可以被细分为液柱压力测量仪、活塞压力测量仪以及弹性压 力测量仪。 根据测量原理的不同,流量仪表可以分为体积、质量流量仪两种类型,前者 是对材料通过速度进行监测,对于流量的推导采用容积法进行;后者采用直接测 量方法,通过对材料通过质量的计量进行推导。温度仪表的元件一般采用热电阻、热电偶等对热敏感度相对稳定的材料,以便使对生产环境温度的测量结果更加准确。 液位仪表的作用是对材料液位进行监测,工作原理包括磁致伸缩、矩阵涡流、雷达、浮力等,采用不同工作原理的液位仪表,其具体的工作方式也往往存在一 定程度的差异。在线过程分析仪的作用是对生产过程进行分析和控制,是一种完 全实现了自动化和智能化的电气仪表,一般需要其它类型精密仪器的辅助,如液 相色谱仪、质谱仪等。 二、电气仪表常见故障的诊断与维修 1.故障诊断的基本方法 受电气仪表种类繁多的影响,故障诊断的方式方法也不尽相同,但也有一些 基本性的检查步骤。下面,我们就从仪表工作状态、非工作状态两个方面。对一 般性的检查步骤进行介绍和讨论。工作状态下的故障诊断:首先,对各部件电源 指示灯进行检查,并查看是否存在异响、异味或非正常高温问题。其次,对仪表 机械传动部位的运行情况进行检查,了解是否存在传动失灵、变形、磨损、卡死 等问题。最后,检查仪表电路,了解是否存在元器件功能损坏或短路问题。非工 作状态下的故障诊断:首先检查仪表外观,如表盘、外壳是否破损,同时查看开关、重要部件、指针等是否能够正常工作。其次,对各功能部件的连线是否牢靠 进行检查,若无问题,则检查元件焊点、保险丝、接触器、继电器是否正常。最后,对线路是否存在故障、各部件排列是否合理进行检查。 2.常见故障的排除

速达软件常见问题处理方法 解决方法

速达软件问题处理锦集----安装与启动 1、在安装MSDE数据库时,出现安装程序倒退的情况 产品名称:MSDE 版本信息:速达所有版本 模块名称:这是以前装过SQL Server数据库或MSDE数据库,没有卸载干净. 解决方案:解决办法重装操作系统 2、安装MSDE数据库时,系统出现“读取文件C:\program files\Microsoft sql sever\mssql\data\msdbata.mdf时出错”的提示信息。 产品名称:MSDE 版本信息:SQL SERVER2000 模块名称:安装 解决方法:退出安装程序,删除C盘里SQL Server文件夹,删除后再重新安装数据库。 3、安装MSDE数据库时,提示安装程序被挂起。 产品名称:MSDE 版本信息:SQL SERVER2000 模块名称:安装 解决方法:重新启动电脑。 4、打开软件时,系统出现以下的提示信息:“未设置登录账号和密码”,请问如何解决? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:系统维护 解决方案:1、以管理员身份登录;2、关闭防火墙; 3、再次登陆时会提示输入用户名与密码; 4、到微软网站下载MSDE最新版本。 5、在启用过程中提示:“数据库用户及密码错误”? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:数据库 解决方案:1、确定是否在数据库中设置了用户名和密码,准确录入;2、重装SQL-SERVER个人版。 3、在SQL-Server 2000中,打开企业管理器,重新注册一个数据库用户组。 6、登陆软件时,系统提示“无法连接数据库,请检查SQL服务器或网络连接是否正常”,请问如何解决? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:日常维护 解决方法:在控制面板添加硬件中添加虚拟网卡。(进入添加硬件向导,添加新硬件,检测过后选择添加新设备,再选择从列表中选取,选中网卡下一步,查找制造商Microsoft有一个设备Microsoft Loopback Adapter,选中它,安装完成后,查看硬件管理器,会多出一个新网卡,这就是虚拟网卡。) 7、启动服务器时提示:通常每个套节字地址(协议网络地址/端口)只允许使用一次,无法登陆,如何解决? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:服务器设置 解决方案:1、注意电脑上有没有在已打开服务器情况下再进行多次打开服务器。 2、客户多次点击软件造成的,重新启动电脑,双击软件即可; 3、注意我们所有速达3000系列都用3001端口,我们的7000与5000系列都用5001端口在所有默认设置下,不能打开多个速达3000服务器,也不能

常见仪表故障分析处理及方法

目录第一章自动化仪表故障综合分析 工业仪表故障分析判断方法 仪表故障的一般规律 应用万用表分析和解决仪表故障 电动、气动仪表的故障判断及维修 第二章流量监测仪表故障处理 电磁流量计 超声波流量计 涡轮流量计 强力巴流量计 第三章物位检测仪表故障处理 雷达物位计 超声波物位计 液位计 第四章压力检测仪表故障处理 智能压力变送器或智能差压变送器 压力开关 压力表 第五章温度检测仪表故障处理 热电阻温度变送器 热电偶温度变送器

第六章气动薄膜调节阀故障处理 气动薄膜调节阀 第七章电动执行机构故障处理 电动执行机构 第八章电子秤故障处理 电子料斗秤 电子皮带秤 电子转子秤 电子地磅/汽车衡 第九章分析仪故障处理 HLA-M105C(O2 CO)在线气体分析系统 SCS-900C烟气连续监测系统(烟气分析仪) GXH-904D型气体分析系统 CEMS-2000型烟气分析系统 常见仪表故障分析处理及方法 第一章自动化仪表故障综合分析 工业仪表故障分析判断方法 仪表故障分析是一线维护人员经常遇到的工作,根据多年仪表维修经验,整理了工业仪表故障分析判断的十种方法,比较原则地介绍如下: 1.1.1调查法 通过对故障现象和它产生发展过程的调查了解,分析判断故障原因的方法。一般有以下几个方面:

⑴故障发生前的使用情况和有无什么先兆; ⑵故障发生时有无打火、冒烟、异常气味等现象; ⑶供电电压变化情况; ⑷过热、雷电、潮湿、碰撞等外界情况; ⑸有无受到外界强电场、磁场的干扰; ⑹是否有使用不当或误操作情况; ⑺在正常使用中出现的故障,还是在修理更换元器件后出现的故障; ⑻以前发生过哪些故障及修理情况等。 采用调查法检修故障,调查了解要深入仔细,特别对现场使用人员的反映要核实,不要急于拆开检修。维修经验表明,使用人员的反映有许多是不正确或不完整的,通过核实可以发现许多不需要维修的问题。 1.1.2直观检查法 不用任何测试仪器,通过人的感官(眼、耳、鼻、手)去观察发现故障的方法。 直观检查法分外观检查和开机检查两种。外观检查内容主要包括: ⑴仪器仪表外壳及表盘玻璃是否完好,指针是否变形或与刻度盘相碰,装配紧固件是否牢固,各开关旋钮的位置是否正确,活动部分是否转动灵活,调整部位有无明显变动; ⑵连线有无断开,各接插件是否正常连接,电路板插座上的弹簧片是否弹力不足、接触不良,对于采用单元组合装配的仪表,特别要注意各单元板连接螺丝是否拧紧; ⑶各继电器、接触器的接点,是否有错位、卡住、氧化、烧焦粘死等现象; ⑷电源保险丝是否熔断,电子管是否裂碎、漏气(漏气后管子内壁附着一层白