搜档网
当前位置:搜档网 › abcam抗体中文使用说明大全

abcam抗体中文使用说明大全

abcam抗体中文使用说明大全
abcam抗体中文使用说明大全

实验方案大全abeam

discover more

2013-2014

Discover more at https://www.sodocs.net/doc/4c2617822.html,

常用的单克隆抗体检测方法

常用的单克隆抗体检测方法 通过杂交瘤技术制备单克隆抗体,在杂交瘤制备完成后,需要对抗体进行一个检测,本文介绍了几种常用的抗体检测的方法(1)免疫酶技术免疫酶技术是将抗原抗体反应的特异性和酶对底物显色反应的高效催化作用有机结合而 成的免疫学技术。由于它特异性强,灵敏度高,现已广泛用于筛选和鉴定单抗。①器材和试剂a、包被缓冲液:碳酸盐缓冲液:取0.2mol/L Na2CO3 8ml,0.2mol/L NaHCO3 17ml 混合,再加75ml蒸馏水,调PH至9.6。Tris-HCl缓冲液(PH8.0,0.02mol/L):取0.1mol/L Tris 100ml,0.1mol/L HCl 58.4ml混合,加蒸馏水至1000ml。b、洗涤缓冲液(PH7.2的PBS):KH2PO4 0.2g,KCl 0.2g,Na2HPO4·12H2O 2.9g,NaCl 8.0g,Tween-20 0.5ml,加蒸馏水至1000ml。c、稀释液和封闭液:牛血清白蛋白(BSA)0.1g,加洗涤液至100ml;或用洗涤液将小牛血清配成5-10%使用。d、酶反应终止液(2mol/L H2SO4):取蒸馏水178.3ml,滴加浓硫酸(98%)21.7ml。e、底物缓冲液(PH5.0,磷酸盐-柠檬酸缓冲液):取0.2mol/L Na2HPO4 25.7ml,0.1ml/L柠檬酸24.3ml,再加50ml蒸馏水。柠檬酸溶液及配成的底物缓冲液不稳定,易形成沉淀,因此一次不宜配制过多。f、底物使用液:OPD底物使用液(测490nm的OD值):OPD 5mg,底物缓冲液10ml,3% H2O2

0.15ml。TMBS或TMB底物使用液(测450nm的OD值):TMBS或TMB(1mg/ml)1.0ml,底物缓冲液10ml,1% H2O2 25ul。ABTS底物使用液(测410nm的OD值):ABTS 0.5mg,底物缓冲液1ml,3% H2O2 2ul。g、抗体对照:以骨髓瘤细胞培养上清作为阴性对照,以免疫鼠血清作为阳性血清。h、抗原:可溶性抗原:尽量纯化,以获得高特异性。病毒感染的传代细胞或全菌抗原。淋巴细胞等悬液。i、酶标抗鼠抗体或酶标SPA或其他类似试剂。j、细胞固定液:-20℃丙酮;或丙酮-甲醛固定液:Na2HPO4 100mg,KH2PO4 500mg,蒸馏水150ml,丙酮225ml,甲醛125ml;或丙酮-甲醛溶液(1;1);或-20℃甲醇。k、聚苯乙烯微孔板:40孔、96孔、或条孔;硬板或软板均可使用。l、酶联免疫阅读仪;或光镜。m、吸管、加样器及水浴箱、离心机等。②可溶性抗原的酶联免疫吸附试验(ELISA)a、纯化抗原用包被液稀释至1-20ug/ml。 b、以50-100ul/孔量加入酶标板孔中,置4℃过夜或37℃吸附2小时。 c、弃去孔内的液体,同时用洗涤液洗3次,每次3-5分钟,拍干。 d、每孔加200ul封闭液4℃过夜或37℃封闭2小时;该步骤对于一些抗原,可省略。 e、洗涤液洗3次;此时包被板可-20℃或4℃保存备用。 f、每孔加50-100ul 待检杂交瘤细胞培养上清,同时设立阳性、阴性对照和空白对照;37℃孵育1-2小时;洗涤,拍干。 g、加酶标第二抗体,每孔50-100ul,37℃孵育1-2小时,洗涤,拍干。 h、加底物

RCS中文说明书

F0/23B(C)、H3/36B、C7030电气系列 F0/23B(C)、H3/36B、C7030Electrical series 使 用 说 明 书 成都久和传动机械有限责任公司 地址:成都市双流县彭镇燃灯社区5组 电话(Phone):(028)67028807 传真(FAX):(028)85847360 邮编(ZIP code):610203

一.使用环境 1.周围空气温度 周围空气温度不超过+40℃,周围空气温度的下限为-25℃。且在24h周期内平均温度不超过+30℃。 2.海拔高度 安装地点的海拔不超过2000m。 3.大气条件 空气清洁,而其相对湿度在最高温度为+40℃,不超过50%,在较低温度时,亦允许有较大的相对湿度,如最湿月平均温度为+20℃,月平均最大相对湿度不超过90%,并注意因温度变化产生在产品表面的凝露。 4.供电电网质量 供电电网容量应保证满足塔机功耗,进线电压波动范围须保证不超过额定电压值的±10%。起升电控柜(L柜)适用于交流50Hz/380V、60Hz/440V三相电源。 5.安装条件 垂直安装倾斜度不超过5°;安装牢固,在主机工作过程中不会发生相对于主机的平移和垂直跳动;安装部位最高震动条件为:5~13Hz时,位移为1.5mm;13~15Hz时,震动加速度为1.0g。 二.阅读电气原理图的方法 1. 符号表示 各个部分字母表示见下列表格: a)操作,检测,指示

b) Ⅰ部分 c)Ⅱ或Ⅲ部分

d)方向或速度 2 . 工作顺序、工作原理及符号 不同的工作阶段用下面两种不同的形式表示: 在开关转换顺序中 A)在工作顺序示意图中,采用下面符号: 接触器或继电器进入“工作状态”:PV 接触器或继电器进入“停止状态”:PV PV表示两种工作状态。 B)在开关转换顺序中,采用下面符号: 接触器或继电器进入“工作状态”并通过同一机械或电气连锁保持:● 接触器或继电器进入“停止状态”:○ 3. 动作特性和各机构功能 F0/23B(C)、H3/36B、C7030等塔式起重机电气控制柜可工作在交流50Hz/380V、60Hz/440V的额定电压条件下。电气控制柜分A、L、HF柜,分别有供电,吊钩升降,小车变幅、回转几大系统。供电系统(A柜)供电源给塔机各机构的用电、并起电路的短路、过载保护作用。吊钩升降(L柜)控制塔机的吊钩起升、下降;小车变幅系统(HF柜)控制塔机的小车变幅(前后);回转系统(HF柜)控制塔机的回转。

IE安全漏洞及防范措施

IE安全漏洞及防范措施 摘要 谈到联网的计算机,就能想到它百纳海川的资讯,可以在网络的世界里找到自己想了解到的,自己想探索到的新知识,但是要想了解到这些资讯我们需要借助到一个工具,这就是我们每一个人都熟悉的----IE浏览器。技术的进步,离不开知识的传播。时代的需求就是我们的责任,我们要抓住信息时代的脉搏,在Internet飞速发展的今天,互联网成为人们快速获取、发布和传递信息的重要渠道,从而倍受人们的重视。互联网上信息的查找又要通过浏览器的浏览来实现,所以希望通过对IE浏览器的安全漏洞和防范措施的探讨让大家对网络及网络资源搜索的认识以及浏览器的各个功能。 关键词:IE浏览器/漏洞/措施

IE Security vulnerabilities and preventive measures ABSTRACT The PC is popular and the brilliant Computer-Culture is developing rapidly by drived of the Financial globalization,Assimilation of information and the Industrial knowledge-ization.Studying computer knowledge is becoming a consciousness action for many back-hoping people in the Boundary of the century.There are many progresses in the information industry,the time of the network and so on.We can see that more person's work and life are never left by a computer.It isn't left the spread of knowledge by technological progress.The demanding of the time is our responsibility.In the days of the internet developing fastly,we should catch the pulse of it,make the internet become a basilic channel that make people getting,issuancing and passing the news at a rapid rate.And then made the internet receives people's emphasis increasingly.One looking for the information by the browser's browsing,so I hope everyone should increasing Browser vulnerabilities and preventive measures and all kinds of functions of the browser by my paper. Keyword: Internet Explorer /vulnerabilities/measure

单克隆抗体Gazyva(obinutuzumab)注射液使用说明书

单克隆抗体Gazyva(obinutuzumab)注射液使用说明书 2013年第一版 Gazyva(obinutuzumab)注射液使用说明书2013年第一版 新生物制品 批准日期:2013年11月1日;公司:Genentech 药物是第一个具有突破性的治疗指定获得FDA批准 Gazyva是具有突破性的治疗指定获得FDA批准第一个药物。这个指定被承办单位请求和在递交给FDA支持上市批准的生物制品许可申请后很快被授权。在承办单位请求时如果初步临床证据表明药物可能对有严重或危及生命疾病患者可能提供超过可得到治疗重大改善时,FDA可以指定某个药物是突破性治疗。 优先审评,孤儿产品指定 FDA的药物评价和研究中心血液学和肿瘤学产品室主任Richard Pazdur,M.D.说:“今天的批准代表对有CLL患者一个重要的新添加治疗”“这个批准反映对突破性治疗指定程序的承诺,允许我们与公司合作加快发展,审查和提供重要的新药物。”。 https://www.sodocs.net/doc/4c2617822.html,/drugsatfda_docs/label/2013/125486s000lbl.pdf 处方资料重点 这些重点不包括安全和有效使用GAZYVA所需所有资料。请参阅GAZYVA完整处方资料。 GAZYVA(obinutuzumab)注射剂,为静脉输注 美国初次批准:2013

适应证和用途 GAZYVA(obinutuzumab)是一种针对CD20溶细胞抗体和适用于与苯丁酸氮芥[chlorambucil]联用,为有既往未治疗过慢性淋巴性白血病患者的治疗。(1,14) 剂量和给药方法 (1)用糖皮质激素,对乙酰氨基酚[acetaminophen]和抗组织胺预先给药。(2.2) (2)为静脉输注稀释和给药。不要静脉推注或丸注。(2.1) (3)对6个疗程推荐剂量(28天疗程): 1)在疗程1第1天100 mg 2)在疗程1第2天900 mg 3)在疗程1第8和15天1000 mg 4)在疗程2-6第1天1000 mg (2.1) 剂型和规格 1000 mg/40mL (25 mg/mL)单次使用小瓶. (3) 禁忌证 无。 警告和注意事项 (1)输注反应:患者用糖皮质激素,对乙酰氨基酚和抗组织胺预先给药。输注期间严密监视. 对反应中断或终止输注。(2.2,5.3) (2)肿瘤溶解综合征:预料肿瘤溶解综合征;用抗高尿酸血症药物预先给药和充分水化尤其是对有高肿瘤负荷和/或高循环淋巴细胞计数患者。纠正电解质异常,提供支持性医护和监视肾功能和液体平衡。(5.4) (3)中性粒细胞减少:对感染监视。(5.6) (4)血小板减少:监视血细胞计数和出血。出血的处理可能需要血液制品支持。(5.7) (5)免疫接种:不要给活病毒疫苗GAZYVA给予前或期间。(5.8) 不良事件 最常见不良事件(发生率≥10%)是:输注反应,中性粒细胞减少,血小板减少,贫血,发热,咳嗽,和肌肉骨骼疾病。(6) 完整处方资料

贴片机使用说明书中文版

11.6 疑难解答 危险: 严格遵守11.1章中“危险”一节的要求。 警告: 在(废料)切割器或者料盘分隔板附近工作时不论何时都必须戴厚度适度的保护手套。不论(废料)切割器及料盘分隔板刀片处于固定还是可动状态,甚至贴片机已经断电,都存在高风险的受伤可能性。 严禁从下方进入气压切割装置或者从上方进入空的皮带供料器,甚至是为了解决问题(如供料器卡住时)。 11.6.1 更换气压切割刀片 警告: 佩戴厚度适度的保护手套。 取出刀片时,只能捏住它的外面,左边和右边。 严禁将刀片放置身体上,例如,放到膝盖或者腿上。 不要将脚放到刀片上。你可能会重伤自己或者至少将衣服划破。 拆除刀片后确保没人会因踩到刀片伤到他们自己。 11.6.1.1 移除刀片 运行贴片机,开启压缩空气系统。 中断贴片机菜单中可动器件,然后将它取出。 停止运行贴片机,切断总电源,然后关闭压缩空气。开启位于压缩空气单元的针状阀以使压缩空气流动(查看11.1章中“危险”一节)。 松弛螺丝更换喷嘴,略微将它举起并保持它在这一位置。 拔下电缆和喷嘴气动软管 慢慢的拔出喷嘴。 拧下空供料器各个配件的螺丝(参考图11.4.1 -> 11, 9),然后将这些管道移出机器。 警告: 刀片的刀刃处始终可能伤到你自己。 基于这一原因,挡板、顶盖及保护罩(参见图11.4.3 -> 6,7, 2)必须安装到位。 打开连接电缆顶盖(见图11.6.6 -> 5) 拧下位于连接线缆(见图11.6.6 -> 5)处的气压连接阀(Y型插座:见图11.6.3 -> 9) 拔下电源和控制面板插头插座。(见图:see Fig. 11.6.5 -> 11, 10) 仔细解开外部控制面板箱内(见图11.6.5 -> 15)对应的接线头(向左或者向右)。在此期间不要损坏连线。 将顶盖放回控制面板及连接线缆处。 取出供料器斜槽(它只是扣住而已)。这使得取下刀片变得容易。 警告: 刀片下方必须保持干净。(例如,不要把脚放到下面) 在贴装元器件情况下松弛位于贴片机左右两个侧面的缓冲部件(2头M8六角头两边螺钉,见图 11.4.1 -> 15)。

Mrbayes中文使用说明

< >内为需要输入的内容,但不包括括号。所有命令都需要在MrBayes >的提示下才能输入。 文件格式: 文件输入,输入格式为Nexus file(ASCII,a simple text file,如图): 或者还有其他信息: interleave=yes 代表数据矩阵为交叉序列interleaved sequences nexus文件可由MacClade或者Mesquite生成。但Mrbayes并不支持the full Nexus standard。 同时,Mrbayes象其它许多系统软件一样允许模糊特点,如:如果一个特点有两个状态2、3,可以表示为:(23),(2,3),{23}或者{2,3}。但除了DNA{A, C, G, T, R, Y, M, K,S, W, H, B, V, D, N}、RNA{A, C, G, U, R, Y, M, K, S, W, H, B, V, D, N}、Protein {A, R, N, D, C, Q, E, G, H, I, L, K, M, F, P, S, T, W, Y, V, X}、二进制数据{0, 1}、标准数据(形态学数据){0, 1, 2, 3, 4, 5, 6, 5, 7, 8, 9}外,并不支持其他数据或者符号形式。 执行文件: execute 或缩写exe ,注意:文件必须在程序所在的文件夹(或者指明文件具体路径),文件名中不能含有空格,如果执行成功,执行窗口会自动输出文件的简单信息。 选定模型: 通常至少需要两个命令,lset和prset,lset用于定义模型的结构,prset用于定义模型参数的先验概率分布。在进行分析之前可以执行showmodel命令检查当前矩阵模型的设置。或者执行help lset检查默认设置(如图): 略 Nucmodel用于指定DNA模型的一般类型。我们通常选取标准的核苷酸替代模型nucleotide substitution model,即默认选项4by4。另外,Doublet选项用于paired stem regions of ribosomal DNA的分析,Codon选项用于DNA sequence in terms of its codons的分析。 替代模型的一般结构一般由Nst设置决定。默认状态下,所有的置换比率相同,对应于F81模型(JC model)。一般我们选用GTR模型,即nst=6。 Code设置只有在DNA模型设置为codon的情况下才使用。Ploidy设置也与我们无关。 Rates通常设置为invgamma (gamma-shaped rate variation with a proportion of invariable sites),Ngammacat(the number of discrete categories used to approximate the gamma distribution)一般采用默认选项4。通常这个设置已经足够,增加该选项设置的数量可能会增加似然计算的精确性,但所花时间也成比例增加,大多数情况下,由增加该数值对结果的影响可以忽略不计。 余下的选项中,只有Covarion和Parsmodel与单核苷酸模型相关,而我们既不会采用parsimony model,也不会采用the covariotide model,故保留默认状态。 在对矩阵作了以上修改后,重新输入help lset命令,可以查看变化后的设置。 设置先验参数prior: 现在可以为模型设置先验参数了。模型有6种类型的参数:the topology, the branch lengths, the four stationary frequencies of the nucleotides, the six different nucleotide substitution rates, the proportion of invariable sites, and

DNAStar详细中文使用说明书

Sequence Analysis Software for Macintosh and Windows GETTING STARTED Introductory Tour of the LASERGENE System MAY 2001

DNASTAR, Inc. 1228 South Park Street Madison, Wisconsin 53715 (608) 258-7420 Copyright . 2001 by DNASTAR, Inc. All rights reserved. Reproduction, adaptation, or translation without prior written permission is prohibited,except as allowed under the copyright laws or with the permission of DNASTAR, Inc. Sixth Edition, May 2001 Printed in Madison, Wisconsin, USA Trademark Information DNASTAR, Lasergene, Lasergene99, SeqEasy, SeqMan, SeqMan II, EditSeq, MegAlign, GeneMan, Protean,MapDraw, PrimerSelect, GeneQuest, GeneFont , and the Method Curtain are trademarks or registered trademarks of DNASTAR, Inc. Macintosh is a trademark of Apple Computers, Inc. Windows is a trademark of Microsoft Corp. ABI Prism are registered trademarks of Pharmacopeia, Inc. Disclaimer & Liability DNASTAR, Inc. makes no warranties, expressed or implied, including without limitation the implied warranties of merchantability and fitness for a particular purpose, regarding the software. DNASTAR does not warrant, guaranty, or make any representation regarding the use or the results of the use of the software in terms of correctness, accuracy, reliability, currentness, or otherwise. The entire risk as to the results and performance of the software is assumed by you. The exclusion of implied warranties is not permitted by some states. The above exclusion may not apply to you. In no event will DNASTAR, Inc. and their directors, officers, employees, or agents (collectively DNASTAR) be liable to you for any consequential, incidental or indirect damages (including damages for loss of business profits, business interruption, loss of business information and the like) arising out of the use of, or the inability to use the software even if DNASTAR Inc. has been advised of the possibility of such damages. Because some states do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitations may not apply to you. DNASTAR, Inc. reserves the right to revise this publication and to make changes to it from time to time without obligation of DNASTAR, Inc. to notify any person or organization of such revision or changes. The screen and other illustrations in this publication are meant to be representative of those that appear on your monitor or printer.

spyglass中文使用说明

望远镜用户指南

概览............................................... (5) 关于本指南 望远镜 概观 按钮 手势 最多显示头---(HUD)的 工具和手段 入门................................................ (17) 版本和功能 硬件和软件兼容性说明............................................. (17) 启用定位服务 设置最多望远镜 开始标记和跟踪对象............................................. . (22) ViewVinder ................................................. . (23) 设置颜色 设置最多的HUD 快速切换 HUD的操作模式 缩放 指南针................................................. (28) 校准

增强现实和三维罗盘............................................. .. (29) 寻找目标对象 设置最多罗盘 罗盘定位模式............................................... .. (32) 罗经................................................. .. (34) 开始使用罗经............................................... .. (34) 确定启动轴承............................................... .. (35) 漂移和调整 全球定位系统................................................. . (37) 设置最多的GPS 获取GPS数据 设置单位 查找................................................. .. (39) 概观 按钮 快速目标标记 添加目标 管理目标 寻找和跟踪 在地图上观测地点的目标............................................. .. (47) 跟踪................................................. .. (48) 设置跟踪

PD抗体使用指南民间版

PD1抗体使用指南民间版2 最近,生物315陆续接到一些想使用PD1的患者的咨询,主要是关于在使用PD1之前要不要做PDL1基因检测;另外,目前可以购买到的PD1抗体有keytruda和opdivo,二者差别大吗?我们总结了一些数据,希望能帮到大家。最后,附录总结了两个CTLA4抗体(依匹单抗)的临床试验,有兴趣的可以联系。 肿瘤组织PDL1检测结果和PD1抗体效果的关系 1 PDL1检测阳性的患者会更大概率会受益,检测阴性的患者也有受益可能 PDL1显然是目前跟ORR最有关联的指标,看临床数据的总结 这个表总结了目前常用的三个PD1通路抗体在不同肿瘤中对PDL1阳性和阴性的临床实验结果:从ORR上来看,PDL1阳性的效果比PDL1阴性的好很多;从PFS和OS看,PDL1阳性的还是有点优势;但是,即使是PDL1阴性的肿瘤患者也是部分有效的。需要指出的是:不同的临床试验对PDL1阳性和阴性的界定标准是不一样的,有1%的,有5%的,也有50%的(这个可能是另一套评价标准),而且用来检测PDL1表达的抗体也是不一样的。 2 肿瘤组织中PDL1的检测方法和标准 看一组数据:

这是目前临床试验中检测PDL1表达的抗体、检测方法和阳性界定标准,不同公司用不同的方法在做检测,标准也不太一样,一锅粥一样的感觉。这里有一个问题,因为肿瘤浸润的免疫细胞(IC)也会表达PDL1,界定PDL1阳性率的时候要不要包括这些免疫细胞?肿瘤细胞表面的PDL1和IC细胞的PDL1哪一个更适合作为预测PD1效果的标准? 3 肿瘤细胞的PDL1表达 VS 肿瘤中免疫细胞(IC)中的PDL1表达 这是2014年4月的临床实验结果,分析了不同肿瘤患者肿瘤细胞和肿瘤浸润的免疫细胞中PD1/PDL1的表达跟ORR的关系,可以看出来肿瘤细胞的PDL1跟ORR的关系是最强的,p=;用TIL PDL1作为指标也是能预测效果,关联性稍差;但是PDL1阴性的患者依然是有受益的可能。

数字音频处理器中文使用说明

MAXIDRIVER3.4数字音频处理器 ALTO MAXIDRIVER3.4数字处理器是集增益、噪声门、参数均衡、分频、压缩限 幅、延时为一体的全功能数字音频处理器,具有2个输入通道和6个输出通道,本机内设10种工厂预设的分频模式,64个用户程序数据库位置以及利用多媒体卡(MMC)进行128个用户程序外置储存的功能。MAXIDRIVER3.4是新一代全数字音 频处理器,采用分级菜单形式,操作非常方便。 功能键介绍 前面板 1、MODE---分级菜单选择,按动时循环选择PRESET(预设)、DELAY(延时)、EDIT(编辑)、UTILITY(系统设置)菜单功能。同时相对应的LED指示灯会被点亮。这时可以进入所选择的菜单进行参数编辑。 2、LED指示灯---当你用MODE键选择需要编辑的菜单时,相对应的LED指示 灯会被点亮。 3、2X16位LCD显示屏---显示正在编辑或查看的系统参数或系统状态。 4、数据轮---转动这个数据轮可以调节需要编辑的参数的数值,顺时针旋转提高数值,逆时针旋转减低数值。 5、PREV/NEXT---前翻/后翻键,每个主菜单下面都有若干个子菜单,通过按动这两个按键可以向前或向后选择所需要进行编辑的子菜单。 6、NAVIGATION CURSOR KEYS---光标移动键,每个子菜单中都有若干个可以 编辑的参数选择,按动这两个键,可以选择需要编辑的参数,选中的参数会闪烁。 7、CARD---储存卡插入口,在这个插口插入MMC储存卡,利用PRESET(预设) 菜单下,可以对该储存卡进行写入、读出等操作。 8、ENTER---确认键,按此键可以对所选择的菜单或编辑的参数数值进行确认。 9、ESC---取消键,按此键可以对所选择的菜单或编辑的参数数值进行取消操作,返回上一级菜单。 10、输入电平指示表,实时指示A/B两个输入通道输入电平的强弱数值。 11、MUTE---静音按键,按下后将关闭相应输出通道的输出信号,相对应的 红色LED指示灯将点亮。 12、输出电平指示表,显示每个输出通道输出电平大小数值,这里显示的数 值不是绝对的输出电平数值,而是与该列LED指示灯中的LIMIT(限幅)指示为基础相比较的数值。

免疫共沉淀中文使用说明书(Pierce26149)

Pierce? Co-Immunoprecipitation (Co-IP) Kit(26149) 中文说明书 介绍: Thermo 公司的Pierce?免疫共沉淀试剂盒,可通过将铆钉抗体固定在琼脂 糖支撑物上,从裂解液中或其他复杂混合物中,分离出天然蛋白复合物。Co-IP 是一种研究蛋白与蛋白相互作用通用的方法,该方法使用一种诱饵蛋白与抗原 进行免疫沉淀反应,然后可通过免疫共沉淀任何与诱饵蛋白具有相互作用的猎 物蛋白。传统的Co-IP方法使用蛋白A或G共同洗脱抗体的重链和轻链,这很 可能导致将相关的蛋白一起洗脱下来,掩盖一些重要的结果。Pierce?免疫共沉 淀试剂盒通过将共价结合抗体固定在一个胺类活性反应树脂上解决了这一问题。该试剂盒包含足够的用于蛋白结合和恢复的缓冲液,完成对照试验的高校离心 柱和收集管,这些产品进一步缩短了操作实验的时间。 重要产品信息: 略 Co-IP实验步骤: A.抗体固定 注意:以下试验步骤是针对用无胺和其他载体蛋白稀释的10-75μg亲和纯 化抗体(参考重要产品信息一节)。根据实际使用比例参考这一协议步骤。参 考重要产品信息节表1中的建议抗体用量和树脂体积用量。 1.室温平衡胺连接耦合树脂(AminoLink?Plus Coupling Resin)和试剂; 2.为每个Co-IP反应准备2ml 1×Coupling Buffer(超纯水稀释20×Coupling Buffer);

3.轻轻涡旋混匀装有AminoLink?Plus Coupling Resin的瓶子,使其处于悬浮状态。使用大口径(或剪掉一段枪头端),添加50μl树脂悬液到Pierce提供的离心柱中,将离心柱放入微量离心管中,1000g离心1min,弃滤液; 4.添加200μl 1×Coupling Buffer 清洗树脂2次,离心弃滤液; 5.将离心柱放于纸巾上,轻巧离心柱底部,去除剩余的液体,插上底塞; 6.准备10-75μg亲和纯化抗体用于结合蛋白,调整体积至200μl,使用足够的超纯水和20×Coupling Buffer来制备1×Coupling Buffer。例如:添加10μl 20×Coupling Buffer,180μl超纯水和10μl浓度为1μg/μl。可直接添加含有超纯水、20×Coupling Buffer、亲和纯化抗体的树脂在离心柱中。 7.在通风厨中,每200μl反应体系,添加3μl氰基硼氢化钠溶液; 注:氰基硼氢化钠属剧毒物质,操作时要小心并穿戴防护服。 8.拧紧离心柱上螺帽,室温涡旋孵育90-120min,确保浆体在孵育过程中处于悬浮状态; 9.握紧底塞,拧开并拿走螺帽,将离心柱置于收集管中离心,保存滤液以便验证抗体耦合; 10.打开螺帽,添加200μl 1×Coupling Buffer,离心弃滤液,重复此步骤1次; 11. 向离心柱中添加200μl Quenching Buffer,离心弃滤液; 12. 将离心柱放于纸巾上,轻巧离心柱底部,去除残留液体,插上底塞。在树脂上添加200μl Quenching Buffer; 13. 在通风厨中,添加3μl氰基硼氢化钠溶液,拧紧螺帽;轻轻摇动并孵育15min; 14.取出底塞,拧开螺帽,将离心柱置于一收集管中,离心弃滤液; 15.打开螺帽,采用200μl 1×Coupling Buffer洗脱树脂,离心。再次重复此步骤; 16.用150μl Wash Solution洗脱树脂6次,每次洗脱后离心; 17.不管是进行细胞裂解、Co-IP,还是储存树脂,都需要继续进行下列步骤; 18.用200μl 1×Coupling Buffer洗脱树脂2次,每次需离心;

bax抗体使用说明

https://www.sodocs.net/doc/4c2617822.html,/products/2772.html Bax Antibody #2772 PhosphoSitePlus? protein, site, and accession data: Bax No. Size Price 2772S 100 ul ( 10 western blots ) contact cst_intsales@https://www.sodocs.net/doc/4c2617822.html, 2772 carrier free & custom formulation / quantity email request Matching Secondary Antibody Applications Reactivity Sensitivity MW (kDa) Source W IP H M R Mk Endogenous 20 Rabbit Applications Key: W=Western Blotting IP=Immunoprecipitation Reactivity Key: H=Human M=Mouse R=Rat Mk=Monkey Species cross-reactivity is determined by western blot. Species enclosed in parentheses are predicted to react based on 100% sequence homology. Protocols 2772: Immunoprecipitation, Western Blotting Specificity / Sensitivity Bax Antibody detects endogenous levels of total Bax protein. The antibody does not cross-react with other Bcl-2 family members. Source / Purification Polyclonal antibodies are produced by immunizing animals with a synthetic peptide corresponding to the amino-terminal residues of human Bax. Antibodies are purified by protein A and peptide affinity chromatography.

上海耀华A27E中文使用说明书(最全版本)

XK3190-A27E型称重显示指示器 V1.02 上海耀华称重系统有限公司制造

目录 第一章技术参数........................................ - 2 - 第二章安装连接........................................ - 3 - 一、仪表示意图............................................ - 3 - 二、传感器的连接.......................................... - 3 - 三、串行通讯接口与大屏幕.................................. - 4 - 第三章操作说明........................................ - 5 - 一、开机.................................................. - 5 - 二、按键操作说明.......................................... - 5 - 三、称重操作.............................................. - 5 - 第四章标定说明........................................ - 7 - 第五章用户功能设置..................................... - 8 - 第六章信息提示出错说明 ............................... - 10 - 第七章蓄电池的使用 ................................... - 10 - 亲爱的用户: 在使用仪表前,敬请仔细阅读说明书!

外研社版高二英语选修六单词表(带音标、词性、中文)

英文音标词性中文 small talk 闲谈,聊天 informal /in'f?:ml/ adj. 非正式的 serious /'s??r??s/ adj. 严肃的 confidently /'k?nfid?ntli/ adv. 自信地 make friends 交朋友,建立友谊 lack /l?k/ v. 缺乏,缺少 be nervous about对……神经紧张/害怕/胆怯/焦虑不安advance /?d'vɑ:ns/adj. 预先的,在前的 think of 想起,回忆起 nod /n?d/ v. 点头 body language 身体语言,肢体语言 yawn /j?:n/ v. 打呵欠 sigh /sa?/ v. 叹气,叹息 look away from 把目光从……移开 social rules 社交规则 in addition 除此之外,另外 find out 了解(到);找出(信息)opportunity /,?p?'tju:n?t?/ n. 机会 obligation /??bl?'ge??n/ n. 责任;义务 prize /pra?z/ n. 奖品,奖金 application /??pl?'ke??n/ n. 申请 form /f?:rm/ n. 表格 immigration /??m?'gre??n/ n. 移民 visa /'v?:z?/ n. 签证 impolite /??mp?'la?t/ adj. 不礼貌的 tidy /'ta?d?/ v. 使……整洁,整理 refund /r?:'f?nd/ n. 退款 favour /'feiv?/ n. 恩惠,照顾 reception /r?'sep?n/ n. 欢迎会;招待会 embassy /'emb?s?/ n. 使馆 certain /'s?:tn/ pron. 某些 reply /r?'pla?/ n. 回答,答复,回信 saleswoman /se?lz?w?m?n/ n. 女推销员,女销售员 firm /f?:m/ n. 公司 fax /f?ks/ n. 传真(机) outspoken /,aut'sp?uk?n/ adj. 直言不讳的,坦率的,不客气的human being 人类 motto /'m?t??/ n. 座右铭,格言 put one’s foot in 犯使人难堪的错误,说错话 one’s mouth shortcoming /??:t,k?mi?/n. 缺点,短处 absence /'?bs?ns/ n. 缺乏,不存在 as a consequence 因此,结果

PerfectPro压力锅中文使用说明书-精简版

实用文档 Perfect Pro 压力锅 使 用 说 明 书 (本人用PDF格式的压力锅使用说明书的截图制作的Word文档的封面)

WMF压力锅主要部件示意图 1 烹饪指示器2烹饪指示器垫圈 3 主阀门 4 安全阀 5 锅盖手柄 6 锅身手柄 7 锅手柄橙色键 8 金属旋转按钮 9 锅身把手10 密封胶圈11 专利锅底13 残余压力安全装置垫圈14 排气孔径垫圈15 残余压力安全装置小孔

WMF Perfect Pro 压力锅使用说明书 1. 安全提示 1. 使用压力锅之前请仔细阅读本说明,不适当的操作会导致锅具损坏。 2. 建议未阅读本操作说明之前不要使用压力锅。 3. 锅具使用时请不要让小孩靠近,以免发生意外。 4. 禁止将压力锅放进烤箱中,烤箱的高温会使压力锅的把手、主阀门和安全阀受损。 5. 压力锅尚未完全排压前必须小心移动,不要触碰烫热的金属表面,必要时戴上隔热手套。 6. 压力锅只能用于所属用途上,不可用作其它目的。 7. 压力锅利用压力烹饪,不适当的操作会烧毀压力锅。加热之前,请确保锅盖全盖好。相关信息可在本使用说明中找到。 8. 不要强行打开压力锅,不要在锅压力没有完全排空前打开锅盖。相关信息可在本使用说明中找到。 9. 不要无水空锅加热,会造成锅具严重损坏。最低水位:1/4升。 重要提示:切记不要让食物中的水分完全蒸发。过分干烧会导致食物烧焦粘连在锅具上,塑胶柄或锅底铝块烧融以致损坏炉具。如果发生以上情 况请马上关闭热源,等压力锅完全冷却后 再移开。 10. 不要在压力锅加入超过容量2/3的食物。烹饪容易膨胀的食品,例如米饭或菜干等,请不要超过总容量的一半,并按照使用说明书相关的容操作。 11. 使用压力锅时请不要长时间走开,注意调节火力,确保烹饪指示器上升至相应橙色圈。如果加热温度过高,蒸汽会从主阀门排出,烹饪时间过长、大量水分蒸发,会影响锅具使用效果。 12. 请配套使用说明书中列明的炉具。 13. 如果烹饪带皮的肉类(如牛舌),请注意此类食品会在压力作用下发生膨胀,不要在表皮膨胀时刺穿肉块,否则容易引起烫伤。 14. 打开压力锅之前请均匀摇动锅身,以避免蒸汽泡飞溅发生烫伤,特别是使用快速排气或自来水冷却降压方法时。 15. 如果使用快速排气或自来水冷却降压的方法时,注意手、头部及身体远离蒸汽正面排出位置,避免烫伤。 16. 使用前请检查安全阀、主阀门和密封圈能是否正常。只有在功能正常的情况下能确保压力锅的安全,相关信息可在本使用说明中找到。 17. 禁止使用压力锅在加压的情况下油炸食品。 18. 除了进行使用说明中所列举的必要维护之外,不要尝试拆装任何安全部件。 19. 必须定期更换磨损的部件。特别是当其表面褪色,出现裂纹及其他破损现象,或者部件松动、不能与其他部位匹配时,请及时使用WMF原装配件更换。 20. 请使用WMF原装配件。使用相同型号的锅身与锅盖。 21. 千万不要在压力锅的任何一个部件损坏、变形或状况异常与说明书描述不符的情况下使用压力锅。当您遇到此类情况,请与附近的WMF零售商或WMF

相关主题