DS_200B:admin> help

aaaconfig Configure RADIUS for AAA services

ad Specifies all administration domain (AD)-level

operations

ag Configure the Access Gateway feature

agshow Displays the Access Gateway information registered

with the fabric

agtcfgdefault Reset SNMP agent to factory default

aliadd Add a member to a zone alias

alicreate Create a zone alias

alidelete Delete a zone alias

aliremove Remove a member from a zone alias

alishow Print zone alias information

aptpolicy Get and set Advanced Performance Tuning policy auditcfg Modifies and displays audit log filter

configuration.

authutil Get and set authentication configuration backplanetest Backplane connection test for multi-blade systems. backport Test for back-end ASIC pair to ASIC pair links. bannerset Set security banner

bannershow Display security banner

bcastshow Display broadcast routing information bladebeacon Enables or disables blade beaconing or displays the

current mode.

bladedisable Disables all user ports on a blade.

bladeenable Enables all User Ports on a blade.

burninerrclear Clear errors that are stored in the non-volatile

storage

burninerrshow Display errors that are stored in the non-volatile

storage

burninstatus Display the diagnostics burnin status.

camtest Verify QuickLoop's Content Addressable Memory

(CAM).SID translation

centralmemorytest Test ASIC central memory operation.

cfgactvshow Display Effective zone configuration information cfgadd Add a member to a configuration

cfgclear Clear all zone configurations

cfgcreate Create a zone configuration

cfgdelete Delete a zone configuration

cfgdisable Disable a zone configuration

cfgenable Enable a zone configuration

cfgremove Remove a member from a configuration

cfgsave Save zone configurations in flash

cfgshow Print zone configuration information

cfgsize Print size details of zone database

cfgtransabort Abort zone configuration transaction cfgtransshow Print zone configurations in transaction buffer chassisconfig Display or set the chassis configuration chassisname Display or set the chassis's Name

chassisshow Display all Field Replaceable Units (FRU) chipregshow Displays the port registers for a given chip

number.

cmemretentiontest Data retention test of the central memory SRAMs. cmitest Verify CMI bus between ASICs.

configdefault Reset config to factory default

configdownload Load switch config from a server

configshow Print switch config parameters

configupload Save switch config to a server

configure Set switch config parameters

datatypeshow Display available diagnostic data types.

date Print/set the system date and time

dbgshow Display debug levels of various modules defzone Activates or deactivates a default zone

configuration.

diagclearerror Clears diagnostics failure status. diagcommandshow Display diagnostic command descriptions. diagdisablepost Disable diagnostic POST.

diagenablepost Enable diagnostic POST.

diagenv Diagnostic debug parameters management package. diaghelp Display diagnostic command descriptions. diagloopid Select the diagnostics loop ID.

diagmodeshow Displays diagnostic mode configuration. diagpost Displays the contents of port registers and

memories.

diagretry Sets diagnostic retry mode

diagsetburnin Initializes the blade for a burnin run.

diagsetcycle Set diagnostic script parameters. diagsetesdmode Set or display ESD mode.

diagsetshowtime Set or display diagnostic show-time mode. diagshow Display diagnostic status.

diagshowtime Set or display diagnostic show-time mode. diagstatus Display currently running diagnostic tests. diagstopburnin Terminate burnin run on a blade.

distribute Distributes data to switches in a fabric.

dlsreset Turn off the dynamic load sharing (DLS) option dlsset Turn on the dynamic load sharing (DLS) option dlsshow Display the state of the dynamic load sharing

option

dnsconfig Configure DNS service

enclosureshow Display the switch enclosure attributes errclear Clear error log

errdelimiterset Sets the error log start and end delimiter for

messages sent to the console and syslog errdump Print error log (no page breaks)

errfilterset Sets a filter for an error log destination errmoduleshow Displays all the defined modules in the system errshow Print error log

fabportshow Display contents of a particular port's data fabretryshow Display retry count of various fabric commands fabriclog Displays or manipulates the fabric log fabricprincipal Displays/Enables/Disables Principal Switch

Selection mode

fabricshow Print fabric membership info

fabstateclear Clears the fabric state information fabstateresize Changes the number of state entries fabstateshow Displays the fabric state information fabstatsshow Displays the fabric statistics information fabswitchshow Display fabric switch state information fandisable Disables a fan unit.

fanenable Enables a fan unit.

fanshow Print fan status

fastboot Reboot this switch and bypass POST fastwritecfg Configure FC fastwrite feature

fazoneadd Add a member to a fabric assist zone fazonecreate Create a fabric assist zone

fazonedelete Delete a fabric assist zone

fazoneremove Remove a member from a fabric assist zone fazoneshow Print Fabric Assist Zone information fcipchiptest Functional Test of Components in FCIP Complex. fciphelp Print FCIP help info

fcippathtest Data Path Test of the FCIP complex.

fcping Sends a FC ELS ECHO request to a port fcplogclear Clear the FCP log

fcplogdisable Disable logging of FCP events

fcplogenable Enable logging of FCP events

fcplogshow Display FCP probing log information fcpprobeshow Display FCP probing information fcprlsshow Display FCP RLS (read link state) information fcrchiptest Functional Test of FCR FPGA.

fcrconfigure Sets FC Router configuration parameters. fcrfabricshow Displays FC Routers on a backbone fabric. fcrlsancount Display maximum LSAN zone limit.

fcrlsanmatrix Manage LSAN fabric matrix configuration. fcrpathtest Data Path Test on Connection between FCR FPGA and

Central ASIC.

fcrphydevshow Displays FC Router physical device information. fcrproxyconfig Displays or configures proxy devices presented by

an FC Router.

fcrproxydevshow Displays FC Router proxy device information. fcrresourceshow Displays FC Router physical resource usage. fcrrouterportcost Displays FC Router route information.

fcrrouteshow Displays FC Router route information. fcrxlateconfig Displays or persistently configures a translate

(xlate) domain's domain ID for both

EX_Port-attached fabric and backbone fabric.

fddcfg fddcfg manages the fabric data distribution

configuration parameters.

fdmicacheshow Display abbreviated remote FDMI device information

according to remote domain ID

fdmishow Display detailed FDMI device information ficonclear Clears contents of the specified FICON management

database

ficoncupset Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp Displays FICON commands

ficonshow Displays contents of the specified FICON management

database

filtertest Run frame filter test for bloom ASICs. firmwarecommit Commit firmware to stable storage firmwaredownload Download firmware into switch firmwaredownloadstatus Display the progress and status of firmwareDownload firmwarerestore Restore the old firmware in the switch

firmwareshow Display firmware versions in the switch

fosconfig Enable/disable FabOS services

fporttest Functional test of F->N N->F point to point path. framerpathtest Tests data path between ASICs

frureplace Replace a Field Replacable Unit

fspfshow Print FSPF global information

fwalarmsfilterset Configure alarms filtering for Fabric Watch fwalarmsfiltershow Show alarms filtering for Fabric Watch

fwclassinit Initialize all Fabric Watch classes

fwconfigreload Reload Fabric Watch configuration

fwconfigure Configure Fabric Watch

fwfrucfg Configure FRU state and notification

fwhelp Print Fabric Watch help info

fwmailcfg Configure Fabric Watch Email Alert

fwportdetailshow Create a report with detailed port information fwsamshow Show availability monitor information

fwset Set port persistence time

fwsettocustom Set boundary & alarm level to custom fwsettodefault Set boundary & alarm level to default

fwshow Show thresholds monitored and port persistence time grep Linux grep command

h Print shell history

hadisable Disables the High Availability feature in the

switch.

hadump Displays information about the status of the High

Availability feature in the switch.

haenable Enables the High Availability feature in the switch hafailover Forces the failover mechanism so that the Standby

Control Processor (CP)becomes the Active CP. hashow Displays control processor (CP) status hasyncstart Enables HA state synchronization.

hasyncstop Disables the HA state synchronization.

help Print this list

historylastshow Displays last history record

historymode Display or set the mode of the history log historyshow Displays entire history log

httpcfgshow Used to show the version of the Java plug-in used

by the Webtools

i Display process summary

ifmodeset Set the link operating mode for a network interface ifmodeshow Display the link operating mode for a network

interface

interfaceshow Display the FSPF (TM) interface information interopmode Displays/enables/disables Brocade switch

interoperability with switches from other

manufacturers

iodreset Turn off the in-order delivery (IOD) option

iodset Turn on the in-order delivery (IOD) option

iodshow Display the state of the in-order delivery option ipaddrset Set ethernet and FC IP addresses

ipaddrshow Print ethernet and FC IP addresses

ipfilter Manage/display IP filters

iscsihelp Print iSCSI help info

islshow Display the current connections and status

killtelnet Terminate telnet/serial login sessions

interactively

licenseadd Adds license keys to switch

licensehelp Print license help info

licenseidshow Displays the system license ID

licenseport Configure per-port POD license assignments licenseremove Removes a license key from this system licenseshow Displays current license keys

linkcost Set or print the FSPF cost of a link

login Login as a new user

logout Logout from remote session

loopporttest Functional test of L-port M->M path on a loop. lsdbshow Displays the FSPF link state database

memshow Display memory usage in the system.

minicycle Functional test of internal and external transmit

and receive paths at full speed.

minispropshow Displays ASIC pair properties.

more Linux more command

mscapabilityshow Display Management Server Capability. msconfigure Configure Management Server

msplatshow Display the Management Server Platform Database msplatshowdbcb Display the Management Server Database Control

Block

msplcleardb Clear the Management Server Platform Database

fabric-wide

msplmgmtactivate Activate the Management Server Platform Database

fabric-wide

msplmgmtdeactivate Deactivate the Management Server Platform Database

fabric-wide

mstddisable Disables the Management Server Topology Discovery

Management Service

mstdenable Enables the Management Server Topology Discovery

Management Service

mstdreadconfig Display status of Management Server Topology

Discovery Service

myid Display the current login session details nbrstateshow Display FSPF (TM) neighbors' states nbrstatsclear Reset the FSPF (TM) interface counters

netstat Display network connections and statistics

nodefind Display all the devices' PID matching the given

world wide name

nsaliasshow Display local Name Server information with Aliases nsallshow Print global Name Server information nscamshow Print local Name Server Cache information nsshow Print local Name Server information information nszonemember Display the information of all the online devices

which are zoned with the given device. opensource Display information on open source software

utilized in FabOS

passwd Set usernames and passwords

passwdcfg passwdcfg manages the password policies. pathinfo Display routing information between two ports pdshow Show information from Panic Dump file perfaddeemonitor Add end-to-end monitor

perfaddipmonitor Add monitor for IP trafic frame count perfaddreadmonitor Add filter-based monitor - SCSI Read perfaddrwmonitor Add monitor - SCSI Read and Write perfaddscsimonitor Add monitor for SCSI frame count perfaddusermonitor Add filter-based monitor

perfaddwritemonitor Add filter-based monitor - SCSI Write perfcfgclear Clear Performance settings from FLASH perfcfgrestore Restore Performance configuration from FLASH perfcfgsave Save Performance configuration to FLASH perfclearalpacrc Clears the CRC error count associated with a port

and Arbitrated Loop Physical Address (AL_PA). perfcleareemonitor Clears statistics counters of one or more

end-to-end performance monitors. perfclearfiltermonitor Clears counters of one or more filter-based

performance monitors.

perfdeleemonitor Delete end-to-end monitor

perfdelfiltermonitor Delete filter-based monitor

perfhelp Print Performance Monitoring help info perfmonitorclear Clear end-to-end/filter-based/ISL monitors perfmonitorshow Show end-to-end/filter-based/ISL monitors perfsetporteemask Set overall mask for end-to-end monitors perfshowalpacrc Get ALPA CRC count by port and ALPA perfshoweemonitor Show user-defined end-to-end monitors perfshowfiltermonitor Show filter-based monitors perfshowporteemask Show the current end-to-end mask

pkicreate Creates public key infrastructure (PKI) objects pkiremove Removes existing public key infrastructure (PKI)

objects

pkishow Displays existing public key infrastructure (PKI)

objects

policy Configure IPSec encryption and authentication

algorithms

portalpashow Show the ALPAs of a port

portbuffershow Print the buffer allocations for the ports of a

quad

portcamshow Display filter utilization

portcfg Create/Delete a new ip interface/route/arp entry on

the GigE port

portcfgdefault Restore the port configuration to defaults portcfgeport Enable/Disable a port from becoming E_Port portcfgexport Sets a port to be an EX_Port and sets and displays

EX_Port configuration parameters. portcfggport Lock a port as a G_Port

portcfgislmode Configure a port to be ISL R_RDY Mode

enabled/disabled

portcfglongdistance Configure a Long Distance Port

portcfglport Lock a port as a L_Port

portcfgnpivport Enables and disables NPIV functionality on a port. portcfgnport Enable/disable N_Port capability for a port portcfgpersistentdisable Persistently disable a port portcfgpersistentenable Enable a persistently disabled port

portcfgshow Displays port configuration settings. portcfgspeed Configure a port to a particular speed level portcfgtrunkport Configure a port for trunking

portcfgvexport Sets a port to be an VEX_Port connected to FC-IP

and sets and displays VEX_Port configuration

parameters.

portcmd Execute commands (ping etc) on the GigE port portdebug Set debug level and verbosity level of port modules portdisable Disable a specified port

portenable Enable a specified port

porterrshow Print port error summary

portflagsshow Display the port status bitmaps of all ports in a

switch

portledtest Cycle user port LEDs.

portlogclear Clear port activity log

portlogconfigshow Display portlog configuration

portlogdisable Disable portlog facility

portlogdump Print port log (no page breaks) portlogdumpport Print port log (no page breaks)

portlogenable Enables port log facility

portlogeventshow Display information about port log events portloginshow Display port login information

portlogpdisc Set or clear the debug_pdisc_flag

portlogreset Enable portlog facility

portlogresize Resize the port log

portlogshow Print port activity log

portlogshowport Print port activity log

portlogtypedisable Disable port logging

portlogtypeenable Enable port logging

portloopbacktest Functional test of port N->N path.

portmirror Set a port's configuration to be disabled or

enabled

portname Assign or display the name associated with a port portperfshow Print port throughput numbers

portregtest Write/read test of the ASIC SRAMs portregtest. portrouteshow Display various routing tables for a port

portshow Show configured ip interfaces/routes/arp entries on

the GigE Port

portstats64show Display the 64-bit hardware statistics for a port portstatsclear Clear the status of a specified switch port portstatsshow Print hardware statistics

portswap Swaps area numbers

portswapdisable Disable portswap feature

portswapenable Enable portswap feature

portswapshow Display port and area information

porttest Functional test on a live fabric. Starts porttest. porttestshow Retreive information from porttest.

portzoneshow Displays the enforced zone type of the F/FL-ports

of a switch.

powerofflistset sets slot power off list order

powerofflistshow Displays slot power-off order.

psshow Print power supply status

quietmode Displays/enables/disables quietmode on telnet

session

reboot Reboot this processor

routehelp Print routing help info

saschiptest Functional Test of Components in SAS Complex. saspathtest Data Path Test of the SAS complex.

secactivesize Displays size of the active (security) database secauthsecret Creates/Manages DHCHAP secret key details seccertutil Creates/Manages/Displays third party PKI

certificates

secdefinesize Displays size of the defined (security) database secfabricshow Displays security related fabric information secfcsfailover Forces primary role to this FCS switch secglobalshow Displays current internal security state

information

sechelp Displays information about security commands secmodedisable Disables secure mode

secmodeenable Enables secure mode

secmodeshow Displays whether secure mode is enabled or disabled secnonfcspasswd Sets the admin passwd for non-FCS switches secpolicyabort Aborts changes to defined policy

secpolicyactivate Activates all policy sets

secpolicyadd Adds members to an existing policy

secpolicycreate Creates a new policy

secpolicydelete Deletes an existing policy

secpolicydump Displays all members of existing policies secpolicyfcsmove Moves a member in the FCS policy secpolicyremove Removes members from an existing policy secpolicysave Saves defined policy set and sends to all switches secpolicyshow Shows members of one or more policies secstatsreset Resets security statistics

secstatsshow Displays security statistics sectemppasswdreset Resets temporary password sectemppasswdset Sets temporary password

sectransabort Aborts current transaction

secversionreset Resets version stamp

sensorshow Display sensor readings

setdbg Set debug level of the specified module setesdmode Set or display ESD mode.

setmfgmode Set or display diagnostic MFG mode. setmodem Enables or disables modem login to a control

processor (CP)

setsplbmode Set or display SPLB mode.

setverbose Set verbosity level of the specified module sfpshow Print Serial ID SFP information shellflowcontroldisable Disable xon-xoff flow control on console serial

port

shellflowcontrolenable Enable xon-xoff flow control on console serial port slotpoweroff Removes power from a slot.

slotpoweron Restores power to a slot.

slotshow Displays the status of all slots in the system. sltest Serial link test of port N->N path.

snmpconfig Configure SNMP

snmpmibcapset Set options for configuring SNMP Mib/Trap

Capability

snmpmibcapshow Show SNMP Mib/Trap Configuration

spinfab Functional test of switch to switch ISL cabling and

trunk group operation.

spinjitter line-speed jitter measurement

spinsilk Functional test of internal and external transmit

and receive paths at full speed sramretentiontest Data retention test of the miscellaneous SRAMs in

ASIC.

statsclear Clear port and diagnostic statistics.

statstest Statistics counter test for the ASICs.

stopporttest Terminate the running porttest.

supportffdc Modifies or displays first-failure data capture

(FFDC) configuration.

supportftp set support Ftp parameters

supportsave retrieve support data from switch to host supportshow Prints switch information for debugging purposes. supportshowcfgdisable Disables a group of commands under supportshow

command.

supportshowcfgenable Enables a group of commands under supportshow

command.

supportshowcfgshow Displays the groups of commands enabled for

display. by the supportshow command. switchbeacon Set switch beacon on or off switchcfgpersistentdisable Persistently disable a switch switchcfgpersistentenable Enable a persistently disabled switch switchcfgspeed Configures all ports of the switch to a particular

speed level

switchcfgtrunk Configure all ports on the switch for trunking switchdisable Disable this switch

switchenable Enable this switch

switchname Print/set this switch's name

switchreboot Halts and restarts the operational switch. switchshow Print switch and port status switchstatuspolicyset Set policy parameters for overall switch status switchstatuspolicyshow Print policy parameters for overall switch status switchstatusshow Print overall switch status

switchuptime Display the amount of time for which the switch is

up

syslogdfacility Change the syslog facility

syslogdipadd Add syslog daemon IP address syslogdipremove Remove syslog daemon IP address syslogdipshow Print the syslog daemon targets

sysshutdown Provides a graceful shutdown to protect the switch

file systems.

systemverification Run a suit of diagnostic tests on all switches in a

system.

tempshow Print temperature readings

timeout Set/show the IDLE timeout value for a login session topologyshow Display the unicast fabric topology

tracedump generate/remove trace dump or display trace dump

status

trackchangeshelp Print Track Changes help info

trackchangesset Configure alert for login/logout/config update trackchangesshow Displays status of track changes

trunkdebug Debug a trunk link failure

trunkshow Display trunking information

tsclockserver Displays or sets the NTP server address

tstimezone Displays or sets the time zone

turboramtest Turbo SRAM test for bloom ASICs.

txdpath Functional test of ASIC pair TXA TXD connections. uptime Print how long switch has been up

urouteconfig Configure a static route

urouteremove Remove a static route

urouteshow Display unicast routing information

userconfig Display or configure user accounts

userrename Rename user login name

version Print firmware version

wwn Display or set the world wide name

zone Copies/Removes/Validates zone objects

zoneadd Add a member to a zone

zonecreate Create a zone

zonedelete Delete a zone

zonehelp Print zoning help info

zoneobjectcopy Copies a zone object

zoneobjectexpunge Expunges a zone object

zoneobjectrename Rename a zoning Object

zoneremove Remove a member from a zone

zoneshow Print zone information

博科BROCADE交换机常用命令与zone配置

telnet 10.77.77.77 admin password ctrl+c Help 不带任何参数会列出所有交换机的命令 带参数时输出如下 Switchshow 查看交换机状态 Chassisshow 显示外壳信息.重要的是可以显示序列号

Configure, 以菜单的形式对交换机进行配置.这个命令需要先使用switchdisable命令将交换暂停使用.第一个选项Fabric parameters 如选yes.那么我们可以进入他的子选项去更改domain ID. Configdefault 恢复出厂默认设置,也需要先做switchdisable Licenseshow, licenseadd, licenseremove, license的添加,查看,删除命令 configupload 和configdownload,可以将配置文件上传或下载.支持ftp scp和local ipAddrShow和ipAddrSet,查看设置管理端口的IP地址

Version: 查看firmware 版本 Sfpshow查看sfp状态 Userconfig 查看和配置登陆账号

Domainsshow 查看交换机的domain信息 Zone 的配置 Zoning是Brocade交换机上的标准功能,通过在SAN网络中交换机上进行Zoning的配置,可以将连接在SAN网络中的设备,逻辑上划分为不同的区域,使各区域的设备相互间不能访问,是网络中的主机和设备间相互隔离 Zone的配置示例

创建Members,就是给端口或wwn创建别名,这里创建了3个别名,每个别名包括3个端口. 红线标出的1,1表示domain1 中的1号端口. 创建Zones 通过zonecreate 命令可以将别名,或端口名添加到zone中. 创建Configurations.将创建的zone添加到配置中.

博科存储交换机安装配置

Brocade 300 交换机配置文档 Brocade 300 是一款吞吐量为 8 Gbit/秒的光纤通道交换机,是专为小型 SAN 或大型 SAN 边缘而设计的经济型入门级解决方案。中小型企业借助此解决方案可以简化 IT 基础设施、增强系统性能、最大程度地发挥虚拟服务器部署的价值、降低总体存储成本。 Zoning是Brocade交换机上的标准功能,通过在SAN网络中交换机上进行Zoning的配置,可以将连接在SAN网络中的设备,对于设备来说是透明的。这里的区域划分都是在Brocade交换机上完成的,划分区域的工作对于主机和存储设备来说都是透明的,在他们上面不需要进行任何配置。他们会以为SAN网络中只有Zone 中的几台设备,根本没有其他的设备存在。 交换机zone规划说明: 交换机端口说明 Brocade交换机采用B/S架构,远程客户端通过交换机以太网管理端口实现对交换机的监控及配置。在配置之前首先要在客户端安装JAVA运行环境JRE 1、首先从ORACE官方网站上下载最新版本JRE:,双机安装

点击安装 软件安装过程 点击关闭完成安装 2、修改本机IP地址与交换机为同一子网,打开浏览器输入: 按下回车后会弹出登陆对话框,输入用户名:admin 密码:password 登陆后界面 点击Zone Admin进入zone的配置界面 在zone的配置界面可以看到交换机的各个端口信息和wwn网络信息 3、配置zone

点击New Zone 输入一个新建zone的名称“cjapp1” 点击Add Members将2(连接存储控制器A)端口、3(连接存储控制器B)端口、4(连接应用服务器1号机HBA卡)端口添加到右方的zone members中。 同样的方法新建zone“cjdb1”,并添加0(连接数据库服务器1号机HBA卡)端口、2(连接存储控制器A)端口、3(连接存储控制器B)端口到zone members中。 同样的方法新建zone“cjdb2”,并添加1(连接数据库服务器2号机HBA卡)端口、2(连接存储控制器A)端口、3(连接存储控制器B)端口到zone members中。4、创建zone config 点击“zone config”选项卡,点击“new zone config”输入新建的zone config 的名称“cjdb1cfg” 将上一步骤中建立的3个zone添加到zone config members中,然后先点击“save config”在点击“enable config” 至此博客交换机配置完成。

Brocade FWS 日常维护介绍 博科交换机配置命令

日常维护命令介绍
? 2011 Brocade Communications Systems, Inc.
10

Console Port
DB-9 male interface. VT-100 terminal - straight-through cable (female to female not a null-modem).
The VT-100 configuration is: 9600 Baud 8 Data Bits Parity = None Stop Bits = 1 Flow Control = None For MODEM Cross-Over cable (typically a DB-9F to DB-25F cable)
? 2011 Brocade Communications Systems, Inc.
11

Stackables Layout
1 2
3 4
5 6
7 8
Link / Act
? 2011 Brocade Communications Systems, Inc.
FDX 100
12

Command Line Interface (CLI) Basics
Configure via character-based terminal/session Direct Connect to the Serial Port or Telnet to the System “?” at any prompt shows available commands SW-FI4802-PREM>? enable fastboot ping show stop-traceroute traceroute Enter Privileged mode Select fast-reload option Ping IP node Display system information Stop current TraceRoute TraceRoute to IP Node
“?” At end of character string SW-FI4802-PREM> s? will list commands show Display system information that begin with stop-traceroute Stop current TraceRoute that string SW-FI4802-PREM> stop-traceroute ^? “^?” At the end of a character string will list the next string SW-FI4802-PREM> stop-traceroute parameter “^” means space can be used for “?”
Commands can be abbreviated
? 2011 Brocade Communications Systems, Inc.
13

博科光纤交换机各种参数配置

Brocade FC Switch 参数配置 一、brocade交换机的管理方式 PC用网线或者串口线连接光交来管理交换机 串口管理 对于windows的系统,串口参数如下 传输速率: 9600bit/sec 数据位: 8 校验位: None 停止位: 1 流控制: None 对于UNIX环境串口线连接好输入命令 # tip /dev/ttyb –9600 图形界面管理 提供基于HTTP的交换机管理界面 在每台交换机上通过许可证激活 为Fabric Manager所必需 支持的操作系统 –WindowsXP,7,2008, –Solaris 2.7, 2.8 浏览器 –Netscape 4.77及后续版本 –Windows Internet Explorer 5.5 with Service Pack 2以上版本 需要java运行环境1.6 以太网管理方式在IE(浏览器)输入http://10.77.77.77可进入web管理页面进行管理配置 用户类型 admin: 可以执行所有的命令并查看交换机状态和修改交换机的配置 user: 执行Show命令来查看交换机的状态 root: Linux底层超级用户 factory: 出厂配置用户 密码修改 以admin身份执行passwd命令 会显示每个用户,可以依次修改他们的密码 初次登录, 系统将提示修改缺省口令, 用户可以修改root, admin, user和factory的缺省口令. 使用passwd命令修改口令 passwd ["user"] “user”可以修改自己的口令, 系统将提示输入旧的口令, 然后可以输入新口令. admin可以修改user和factory的口令, 系统提示输入旧的口令. root可以修改admin, user和factory 的口令, 系统不提示输入旧口令.

Brocade光纤交换机常用命令

标签:? 2013-12-24 10:19?2062人阅读?(0)?? ?分类: San IBM的双机双柜,两光纤交换机分别引一根光纤到另一楼光纤交换机,插上无反应,后得知需要更改交换机的domain id 默认出厂为1。需改为不同号。下面是博科的交换机命令转。 Brocade SAN交换机常用命令 默认用户名:admin,默认密码password 1. switchStatusShow 查看交换机的总体健康状态 switch:admin> switchstatusshow Switch Health Report Switch Name: SWFCR SwitchState: MARGINAL Duration: 863:23 Power supplies monitor MARGINAL Temperatures monitor HEALTHY Fans monitor HEALTHY WWN servers monitor HEALTHY Standby CP monitor HEALTHY Blades monitor HEALTHY Flash monitor HEALTHY Marginal ports monitor HEALTHY Faulty ports monitor HEALTHY Missing SFPs monitor HEALTHY All ports are healthy switch:admin> 2. switchShow 查看交换机基本配置信息 Enter the switchShow command, which displays the following information for a switch: - switchname - The switch name. - switchtype - The switch model and firmware version numbers. - switchstate - The switch state: Online, Offline, Testing, or Faulty. - switchrole - Displays the switch role: Principal, Subordinate, or Disabled. - switchdomain - Displays the switch Domain ID. - switchid - The embedded port D_ID of the switch. - switchwwn - The switch World Wide Name.

(完整版)博科光纤交换机基本配置

博科 300光交换配置手册 1.设备示意图 2.配置准备 Brocade交换机采用B/S架构,远程客户端通过交换机以太网管理端口实现对交换机的监控及配置。在配置之前首先要在客户端安装JAVA运行环境JRE。 3.设备配置 修改客户端IP地址与交换机为同一子网10.77.77.100; 打开浏览器输入http://10.77.77.77按下回车后会弹出登陆对话框;户名:admin 密码:password 备注:admin: 可以执行所有的命令并查看交换机状态和修改交换机的配置 user: 执行Show命令来查看交换机的状态?改变密码 以admin身份执行passwd命令 会显示每个用户,可以依次修改他们的密码 4.常用配置命令 1)Tip: 可使用下面的命令来检查Fabric OS的版本 sw:admin> version Kernel: 5.3.1 Fabric OS: v3.0.2c Made on: Thu Apr 19 12:02:15 PDT 2002 Flash: Thu Apr 19 12:04:03 PDT 2002 BootProm: T ue Apr 26 18:33:23 PST 2002 2)ipAddrShow –显示交换机的IP设置 sw:admin> ipAddrShow Ethernet IP Address: 10.77.77.77 Ethernet Subnetmask: 255.255.255.0 Fibre Channel I P Address: none Fibre Channel Subnetmask: none Gateway Address: 0.0.0.0 ? ipAddrSe t 3)为交换机设置IP地址 sw:admin> ipAddrSet Ethernet IP Address [10.77.77.77]: 192.168.66.107 Ethernet Subnetmask [0.0.0.0]: 255 .255.255.0 Fibre Channel IP Address [none]: Fibre Channel Subnetmask [none]: Gatew ay Address [172.17.1.1]: Set IP address now? [y = set now, n = next reboot]: y ? sw2: 4)显示交换机配置 admin> switchShow

博科Brocade交换机配置

设置博科Brocade交换机IP地址 博科交换机的默认IP地址是10.77.77.77,在命令行模式下可以通过ipaddrset命令对交换机的IP地址进行设置和修改 swd77:admin> ipaddrset Ethernet IP Address [10.77.77.77]: #输入交换机需要设置的IP地址 Ethernet Subnetmask [255.255.255.0]: #输入掩码 Fibre Channel IP Address [none]: Fibre Channel Subnetmask [none]: Gateway IP Address [none]: # 输入网关 DHCP [Off]: #是否开启DHCP swd77:admin> 一般情况下只需要设置Ethernet 的IP和掩码就可以了,这个IP地址主要是用来对交换机进行管理设置。 Brocade SAN交换机的几种管理方法 为了对SAN网络进行管理,Brocade公司了丰富的管理工具,来适应不同场景下对SAN 网络的管理。 Telnet 交换机管理的最基本方法,通过命令行的方式直接登录到交换机上,通过交换机上操作系统(Fabric OS)提供的命令对交换机作管理工作。能完成对单台交换机管理的所有功能,对操作者对管理命令非常熟悉。不适合非专业人士使用。 WEB TOOLS 图形界面的管理工具,通过浏览器对交换机完成管理工作。视觉效果比Telnet好很多,并且在性能监视时能提供多种视图。能完成对单台交换机管理的大多数功能,适合大多数用户使用。 Fabric Manager 对SAN网络中的交换机进行批量管理的工具。能对SAN网络中的多台交换机,在一个管理站一次性的完成管理工作。方便SAN网络的统一管理。 SNMP 网络管理的标准协议

博科光纤交换机操作手册

与交换机交互,可以使用三种方式: 串口 以太网口 光纤口 缺省的串口参数是:9600,N,8,1 缺省IP访问方式是: IP地址: 10.77.77.77 用户名: admin 密码:password 时区: Pacific time 交换机名称:switch 可使用ipAddrSet命令来重新设置交换机的IP地址。 在2000和3000系列交换机之中,只能同时支持一个Telnet进程。 Brocade的交换机可以使用命令行和图形界面方式进行管理。 代表性的CLI方法代表性的如:Telnet,HyperTerm和tip。对于Fabric OS v4.1,SSH v2可以被使用。 如果Brocade Secure Fabric OS被设置有效,CLI 接口必须是Brocade Secure Telnet. Brocade API v2.1提供给用户扩展访问到交换机的方法;可以轻松的整合Brocade SAN Fabric的智能到已经存在的管理应用中,或者快速的开发用户SAN 的特殊功能。该工具包可以通过Brocade Connect 站点获得。 Brocade Fabric Manager v4.0 是一个实时管理多台Brocade 光纤交换机的很好的一个工具,它提供了有效的配置、监控、动态资源分配管理。 Brocade Web Tool是一个直观简单的管理小型SAN网络的管理工具。运行支持JRE的Web Browser上。 Brocade 提供基于SNMP的MIBs用来在交换机上读和配置公共设置。

串口管理: n 一条串口连接电缆 DB9 (female-to-female) n 使用超级终端或UNIX终端 n Windows: Hyper Terminal n UNIX: tip u Microsoft Windows? 环境之中 –传输速率: 9600bit/sec –数据位: 8 –校验位: None –停止位: 1 –流控制: None u UNIX? 环境下, 输入以下命令 # tip /dev/ttyb –9600 u 安装步骤 1. 通过串口线将两者进行连接 2. 确保交换机已经加电 3. 通过ipAddrSet命令设置IP地址 (注意: 命令是大小写敏感,但是全大写或全小写也可。) 登录方式: ?用户 ?admin: 可以执行所有的命令并查看交换机状态和修改交换机的配置 ?user: 执行Show命令来查看交换机的状态 ?改变密码

博科交换机安装配置手册

GL_SW6520_505,Domain:7,SN:CHQ2518L01W,机柜:A601-S13#25-26,IP:192.168.0.75/24,Netmask:192.168.0.200 GL_SW6520_506,Domain:8,SN:CHQ2518L01Z,机柜:A601-S15#25-26,IP:192.168.1.75/24,Netmask:192.168.1.200 配置示例: **switch default user and password :admin/password **switch default management ip: 10.77.77.77 1.Change switch name switch:admin>switchname GL_SW6510_503 2.Change switch domain ID switch:admin>switchdisable switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] y Domain: (1..239) [1] 49 save the setting with "Control+D" keys switch:admin>switchenable 3.Change switch management IP switch:admin>ipaddrset Ethernet IP Address [10.77.77.77]:192.168.0.105 Ethernet Subnetmask [255.255.255.0]:255.255.255.0 Gateway IP Address [192.168.0.200]:192.168.0.200 DHCP [Off]: 4.Change timezone switch:admin>tstimezone +8

brocade光纤交换机基本配置

1,改修端口速率: brocade4Gb:admin> portcfgspeed 2 2 ####端口号速率 2,改修Domain ID: brocade4Gb:admin> switchdisable brocade4Gb:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] yes Domain: (1..239) [2] 3 R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000..5000) [2000] WAN_TOV: (0..30000) [0] MAX_HOPS: (7..19) [7] Data field size: (256..2112) [2112] Sequence Level Switching: (0..1) [0] Disable Device Probing: (0..1) [0] Suppress Class F Traffic: (0..1) [0] Per-frame Route Priority: (0..1) [0] Long Distance Fabric: (0..1) [0] BB credit: (1..27) [16] Insistent Domain ID Mode (yes, y, no, n): [no] Virtual Channel parameters (yes, y, no, n): [no] F-Port login parameters (yes, y, no, n): [no] Zoning Operation parameters (yes, y, no, n): [no] RSCN Transmission Mode (yes, y, no, n): [no] Arbitrated Loop parameters (yes, y, no, n): [no] System services (yes, y, no, n): [no] Portlog events enable (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no]

BROCADE博科光纤交换机的配置手册

BROCADE博科光纤交换机的配置手册博科Brocade 200E配置

所有Brocade 交换机均基于Brocade Fabric OS智能操作系统。在配置交换机时,可以使用Brocade Web Tools 提供的字符命令界面,也可以使用Brocade Fabric Manager 图形界面管理程序。 在乌鲁木齐W AP局点中,一台计费(JF1)和一台统计(RP1)通过光纤交换机(Brocade SW200E)挂接磁阵(见图1)。每台Dell服务器都有2块HBA卡连接光纤交换机,既可以冗余备份,又起到负载均衡的作用。 安装光纤交换机,主要分为以下几个步骤: 1、安装光纤卡,连接光纤到交换机和磁阵。把每台服务器的2块HBA卡分别连到2台光纤交换机。 2、在光纤交换机上给每个端口命名,好处就是容易分清楚各个端口连接的具体设备。当然,也可以不命名。 3、划分zone,划分的思路是以发起的服务器为主,把到目的端的多条路径一起划分到一个zone中。以RP1为例,连接Switch OW1的2端口,到EMC磁阵有2条路径,分别通过端口0和端口1,所以就把端口0,1,2划分到一个zone中。当然,也可以把每条路径都划为一个zone。 4、保存配置文件。 图1 光纤交换机连接图 下面是通过图形界面配置光纤交换机的详细步骤:

1.通过以太网端口登陆,起始默认管理地址是:10.77.77.77,用户名/密码:admin/password。在连接光纤交换机的电脑上配置同网段的地址,在IE中输入管理地址,就可以登陆。注意:连接的电脑需要安装jre1.4以上,网页才能正常显示。 2.图形界面中,选择Admin,会弹出新的配置网页,见下图。点击Switch窗口,输入机器光纤交换机的名字:WLMQ-PS-WAP-OW2,Domain ID 输入2,别的数字也可以,没有影响。点击Network,可以修改管理ip地址等内容。可以通过View Report查看所有的配置信息。

博科交换机操作手册

B24 交换机操作手册 一、基本配置操作 1. 连接到B24 1.1、SSH 说明: 交换机管理的最基本方法,通过命令行的方式直接登录到交换机上,通过交换机上操作系统(Fabric OS)提供的命令对交换机作管理工作。能完成对单台交换机管理的所有功能。 连接方法: 用SSH工具通过B24 IP地址登陆。默认用户:admin,默认密码:password。 1.2、Web Tools 说明: 图形界面的管理工具,通过浏览器对交换机完成管理工作。视觉效果比Telnet好很多,并且在性能监视时能提供多种视图。能完成对单台交换机管理的大多数功能。 连接方法: 在浏览器上输入B24的IP地址。默认用户:admin,默认密码:password。 1.3、串口管理 说明: 通过串口线连接到B24交换机的串口上进行管理 连接方法: 使用串口线连接B24和笔记本/工作站的串口,打开“超级终端”,配置如下: Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: None 当超级终端停止报告信息,按“Enter”显示login信息,

默认用户:admin,默认密码:password。 2. 设置IP地址 B24默认IP地址为:10.77.77.77/24. 设置交换机IP地址: > ipaddrset Ethernet IP Address [10.77.77.77]: 192.56.211.5 Ethernet Subnetmask [255.255.255.0]: Fibre Channel IP Address [none]: Fibre Channel Subnetmask [none]: Gateway IP Address [none]: DHCP [Off]: 显示交换机的IP > ipaddrshow 3. 设置默认账号密码 B24交换机有两个默认的账号,admin和user账号。 Admin:为管理员账号 User:为非管理员账号(比如可以用来监视系统) 3.1、登录时更改密码: 在第一次登录B24时,系统会提示更改系统账号密码或者跳过更改login: admin Password: Please change your passwords now. Use Control-C to exit or press 'Enter' key to proceed. for user - root Changing password for root Enter new password: *****

BROCADE博科光纤交换机的配置手册(精编文档).doc

【最新整理,下载后即可编辑】 博科Brocade 200E配置

所有Brocade 交换机均基于Brocade Fabric OS智能操作系统。在配置交换机时,可以使用Brocade Web Tools 提供的字符命令界面,也可以使用Brocade Fabric Manager 图形界面管理程序。 在乌鲁木齐WAP局点中,一台计费(JF1)和一台统计(RP1)通过光纤交换机(Brocade SW200E)挂接磁阵(见图1)。每台Dell 服务器都有2块HBA卡连接光纤交换机,既可以冗余备份,又起到负载均衡的作用。 安装光纤交换机,主要分为以下几个步骤: 1、安装光纤卡,连接光纤到交换机和磁阵。把每台服务器的2块HBA卡分别连到2台光纤交换机。 2、在光纤交换机上给每个端口命名,好处就是容易分清楚各个端口连接的具体设备。当然,也可以不命名。 3、划分zone,划分的思路是以发起的服务器为主,把到目的端的多条路径一起划分到一个zone中。以RP1为例,连接Switch OW1的2端口,到EMC磁阵有2条路径,分别通过端口0和端口1,所以就把端口0,1,2划分到一个zone中。当然,也可以把每条路径都划为一个zone。 4、保存配置文件。

图1 光纤交换机连接图 下面是通过图形界面配置光纤交换机的详细步骤: 1.通过以太网端口登陆,起始默认管理地址是:10.77.77.77,用户名/密码:admin/password。在连接光纤交换机的电脑上配置同网段的地址,在IE中输入管理地址,就可以登陆。注意:连接的电脑需要安装jre1.4以上,网页才能正常显示。

博科BrocadeSAN交换机常用命令

博科BrocadeSAN交换机常用命令 博科Brocade SAN交换机通用命令 1。查看IP地址命令............................................................................................................2 2.查看固件版本.......................................................................................................2 3.查看开关状态 (2) 4.查看交换机许可证-id........................................................................................3 5.配置ZONE........................................................................................................... .......3 6.查看区域配置文件.................................................................................................………4 7.查看区域.................................................................................................................. 5 8.检查系统日志信息................................................................................................... 6 9.停工.................................................................................................................. ................6 10.设置博科锦交换机的IP地址.............................................................................6 11.博科brocade交换机查看操作系统版本信息.................................................................6 12.

博科交换机配置手册

步骤非常详细供大家参考,不会的请问我QQ******* Brocade交换机的系列产品出厂一般都有缺省配置,只要开机就可以正常使用,但是通常都要在交换机上划分ZONE,下面将设置做详细描述。 Brocade交换机的系列产品出厂一般都有缺省配置,只要开机就可以正常使用,但是通常都要在交换机上划分ZONE,下面将设置做详细描述。 Brocade交换机的系列产品出厂一般都有缺省配置,只要开机就可以正常使用,但是通常都要在交换机上划分ZONE,下面将设置做详细描述。 Brocade交换机的系列产品出厂一般都有缺省配置,只要开机就可以正常使用,但是通常都要在交换机上划分ZONE,下面将设置做详细描述。 Brocade交换机的系列产品出厂一般都有缺省配置,只要开机就可以正常使用,但是通常都要在交换机上划分ZONE,下面将设置做详细描述。 1、通过IE浏览器连接到交换机(前提:装有JAVA插件) 打开IE浏览器,在地址栏输入交换机的IP地址,回车进入之后,输入管理员用户名和密码登陆,缺省用户名:Admin,密码:password ,界面如下(图一)

图一 2、点击ZONE ADMIN,进入图二界面:

图二 3、选择第一个项Switch/Port Level Zon…,点击OK,进入界面如下(图三)

图三 4、点击PORT ZONE进入端口ZONE设置,首先CREATE ZONE,输入ZONE名称,双击端口号追加到Members成员,追加完毕之后点击APPLY,一个zone创建完成。以相同的方式创建其他ZONE。 5、点击port confige,进入图四:

BROCADE博科光纤交换机的配置

博科BROCADE交换机配置方法 与博科交换机交互,可以使用三种方式: 串口 以太网口 光纤口 缺省的串口参数是:9600,N,8,1 缺省IP访问方式是: IP地址:10.77.77.77 用户名:admin 密码:password 时区:Pacific time 交换机名称:switch 可使用ipAddrSet命令来重新设置交换机的IP地址。 在2000和3000系列交换机之中,只能同时支持一个Telnet进程。 Brocade的交换机可以使用命令行和图形界面方式进行管理。 代表性的CLI方法代表性的如:Telnet,HyperTerm和tip。对于Fabric OS v4.1,SSH v2可以被使用。 如果Brocade Secure Fabric OS被设置有效,CLI 接口必须是Brocade Secure Telnet. Brocade API v2.1提供给用户扩展访问到交换机的方法;可以轻松的整合Brocade SAN Fabric的智能到已经存在的管理应用中,或者快速的开发用户SAN的特殊功能。该工具包可以通过Brocade Connect 站点获得。 Brocade Fabric Manager v4.0 是一个实时管理多台Brocade 光纤交换机的很好的一个工具,它提供了有效的配置、监控、动态资源分配管理。 Brocade Web Tool是一个直观简单的管理小型SAN网络的管理工具。运行支持JRE的Web Browser上。 Brocade 提供基于SNMP的MIBs用来在交换机上读和配置公共设置。

串口管理: n一条串口连接电缆 DB9 (female-to-female) n使用超级终端或UNIX终端 n Windows: Hyper Terminal n UNIX: tip u Microsoft Windows? 环境之中 –传输速率: 9600bit/sec –数据位: 8 –校验位: None –停止位: 1 –流控制: None u UNIX? 环境下, 输入以下命令 # tip /dev/ttyb –9600 u安装步骤 1. 通过串口线将两者进行连接 2. 确保交换机已经加电 3. 通过ipAddrSet命令设置IP地址 (注意: 命令是大小写敏感,但是全大写或全小写也可。) 登录方式: ?用户 ?admin: 可以执行所有的命令并查看交换机状态和修改交换机的配置?user: 执行Show命令来查看交换机的状态 ?改变密码 ?以admin身份执行passwd命令 ?会显示每个用户,可以依次修改他们的密码 (修改notes)

Brocade SAN 交换机常用命令

查看IP地址命令 swd77:admin>ipaddrshow SWITCH E the rnet IP Address: 10.77.77.77 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: none Fibre Channel Subnetmask: none Gateway IP Address: none DHCP: Off swd77:admin> 设置博科Brocade交换机IP地址 博科交换机的默认IP地址是10.77.77.77,在命令行模式下可以通过ipaddrset命令对交换机的IP地址进行设置和修改 swd77:admin>ipaddrset Ethernet IP Address [10.77.77.77]: #输入交换机需要设置的IP地址 Ethernet Subnetmask [255.255.255.0]: #输入掩码 Fibre Channel IP Address [none]: Fibre Channel Subnetmask [none]: Gateway IP Address [none]: # 输入网关 DHCP [Off]: #是否开启DHCP swd77:admin> 博科brocade交换机查看OS版本信息 swd77:admin> version Kernel: 2.6.14.2 //linux内核版本 Fabric OS: v6.1.0a // 交换机OS版本 Made on: Thu Apr 17 21:45:31 2008 // 生产日期 Flash: Tue Jan 13 23:33:44 2009 BootProm: 4.6.6 swd77:admin> 博科brocade交换机添加license授权信息 swd77:admin>licenseadd XXXXXXXX(博科的激活号) 查看博科brocade交换机license授权信息 在命令行模式下使用licenseshow命令可以查看博科交换机的授权情况,使用licenseadd 命令可以添加授权。 博科Brocade Slikworm 210E交换机授权情况 swd77:admin>licenseshow RzcQSXXXCS0RTc:

Brocade交换机常用命令

Brocade交换机常用命令(下面命令是基于6.x版本的,有些老版本的交换机可能找不到相关命令) 1、switchshow:可以查看交换机的名称、型号、状态、角色、domain ID、wwn、zone状态、zone配置名等。 2、cfgshow:可以查看zone的相关信息、端口的alias等。 3、新建一个zoning: alicreate "hostname","domainid,port" zonecreate "hostname_storage","aliname;aliname" cfgadd "CFGNAME","hostname_strage" cfgsave cfgenable "CFGNAME" 4、licenseshow:查看当前交换机的license 5、switchdisable:将当前交换机禁用,一般用于设置交换机配置时使用 6、switchenable:启用当前交换机 7、日常交换机检查命令: switchshow (交换机、端口状态) hashow (CP卡状态) slotshow (slot状态) psshow (电源状态) tempshow (温度状态) fanshow (风扇状态) firmwareshow (微码状态) licenseshow (license状态) cfgshow (zoning状态) uptime (交换机自上次重启到现在的时间) porterrshow (查看端口的错误信息) errshow (查看交换机的报错信息) 8、zone相关命令: zonecreate:创建一个zone zoneobjectcopy:复制一个zone到一个新的zong zoneobjectrename:重新命名一个zone zoneobjectexpunge:删除一个zone cfgclear:删除所有zone信息 cfgsize:查看zone数据库大小 cfgtransshow:查看是否有未被保存的zone相关信息 cfgtransabort:放弃未被保存的zone相关信息 cfgactvshow:显示激活中的zone配置 configupload:将交换机的配置信息保存到指定的FTP服务器上 9、fabricshow:查看当前fabric中有哪些交换机 10、nsshow:查看当前交换机中有哪些node(设备) 11、nsallshow:查看当前fabric中有哪些node(设备) (完善中.......) 最新回复 skilljiang at 2009-8-10 11:25:45

博科BrocadeSAN交换机常用命令

博科Brocade SAN交换机常用命令 1.查看IP地址命令 (2) 2.查看firmware版本 (3) 3.查看交换机状态 (3) 4.查看交换机license-id (5) 5.配置ZONE (5) 6.查看zone配置文件 (7) 7.查看ZONE (9) 8.查看系统日志信息 (11) 9.关机 (11) 10.设置博科Brocade交换机IP地址 (12) 11.博科brocade交换机查看OS版本信息 (12) 12.博科brocade交换机添加license授权信息 (13) 13.查看博科brocade交换机license授权信息 (13) 14.博科Brocade Slikworm 300交换机license (13) 15.博科Brocade交换机修改密码命令 (14) 16.博科brocade SAN交换机密码重置 (14) 17.登陆后是用passwddefault命令恢复出厂密码 (17)

18.交换机升级 (17) 19.帮助信息 (27) 1.查看IP地址命令 swd77:admin> ipaddrshow SWITCH Ethernet IP Address: 10.77.77.77 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: none

Fibre Channel Subnetmask: none Gateway IP Address: none DHCP: Off swd77:admin> 2.查看firmware版本 swd211:admin> swd211:admin> firmwareshow Appl Primary/Secondary Versions ------------------------------------------ FOS v6.2.1 v6.2.1 3.查看交换机状态 swd211:admin> switchoshow rbash: switchoshow: command not found swd211:admin> switchshow switchName: swd211 switchType: 34.0 switchState: Online switchMode: Native switchRole: Principal

相关主题